Evaluation of alternate lines of Fe for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry


Autoria(s): Raposo Junior, Jorge Luiz; de Oliveira, Silvana Ruella; Caldas, Naise Mary; Gomes Neto, José Anchieta
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

10/10/2008

Resumo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

The usefulness of the secondary line at 252.744 nm and the approach of side pixel registration were evaluated for the development of a method for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The influence of side pixel registration on the sensitivity and linearity was investigated by measuring at wings (248.325, 248.323, 248.321, 248.329, and 248.332 nm) of the main line for Fe at 248.327 nm. For the secondary line at 252.744 nm or side pixel registration at 248.325 nm, main lines for Cu (324.754 nm), Mn (279.482 nm) and Zn (213.875 nm), sample flow-rate of 5.0 mL min(-1) and calibration by matrix matching, analytical curves in the 0.2-1.0 mg L-1 Cu, 1.0-20.0 mg L-1 Fe, 0.2-2.0 mg L-1 Mn, 0.1-1.0 mg L-1 Zn ranges were obtained with linear correlations better than 0.998. The proposed method was applied to seven soil samples and two soil reference materials (IAC 277; IAC 280). Results were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to soil extracts containing 0.15 and 0.30 mg L-1 Cu, 7.0 and 14 mg L-1 Fe, 0.60 and 1.20 mg L-1 Mn, 0.07 and 0.15 mg L-1 Zn, varied within the 94-99, 92-98, 93-101, and 93-103% intervals, respectively. The relative standard deviations (n = 12) were 2.7% (Cu), 1.4% (Fe - 252.744 nm), 5.7% (Fe - 248.325 nm), 3.2% (Mn) and 2.8% (Zn) for an extract containing 0.35 mg L-1 Cu, 14 mg L-1 Fe, 1.1 mg L-1 Mn and 0.12 mg L-1 Zn. Detection limits were 5.4 mu g L-1 Cu, 55 mu g L-1 Fe (252.744 nm), 147 mu g L-1 Fe (248.325 nm), 3.0 mu g L-1 Mn and 4.2 mu g L-1 Zn. (C) 2008 Published by Elsevier B.V.

Formato

198-202

Identificador

http://dx.doi.org/10.1016/j.aca.2008.08.016

Analytica Chimica Acta. Amsterdam: Elsevier B.V., v. 627, n. 2, p. 198-202, 2008.

0003-2670

http://hdl.handle.net/11449/25772

10.1016/j.aca.2008.08.016

WOS:000260202100003

Idioma(s)

eng

Publicador

Elsevier B.V.

Relação

Analytica Chimica Acta

Direitos

closedAccess

Palavras-Chave #Micronutrients #Soil #High-resolution continuum source flame atomic spectrometry #Side pixel registration
Tipo

info:eu-repo/semantics/article