957 resultados para molecularly imprinted polymers


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIPs) are crosslinked polymers containing bespoke functionalised cavities arising from the inclusion of template molecules in the polymerisation mixture and their later extraction. When the polymers are prepared functional polymerisable monomers are included which become part of the polymer matrix and serve to decorate the cavities with functionality appropriate to the template molecules. Overall, binding sites are created which have a memory for the template both in terms of shape and matching functionality. Fluorescent molecularly imprinted polymers have the benefit of a fluorophore in their cavities that may respond to the presence of bound test compound by a change in their fluorescence output. The work presented falls into three main areas. A series of fluorescent MIPs was prepared with a view to generating material capable of mimicking the binding characteristics of the metabolically important cytochrome isoform CYP2D6. The MIPs re-bound their templates and various cross-reactivities were encountered for test compound/drug recognition. One MIP in particular exhibited a rational discrimination amongst the related synthetic templates and was reasonably successful in recognising CYP2D6 substrates from the drug set tested. In order to give some insights into binding modes in MIPs, attempts were made to produce functional monomers containing two or more fluorophores that could be interrogated independently. A model compound was prepared which fitted the dual-fluorophore criteria and which will be the basis for future incorporation into MIPs. A further strand to this thesis is the deliberate incorporation of hydrophobic moieties into fluorescent functional monomers so that the resulting imprinted cavities might be biomimetic in their impersonation of enzyme active sites. Thus the imprinted cavities had specific hydrophobic regions as well as the usual polar functionality with which to interact with binding test compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A presente dissertação descreve o desenvolvimento e a caracterização de sensores potenciométricos com base em polímeros de impressão molecular e de sensores ópticos com base em membranas de poli(cloreto de vinilo), PVC, para a determinação de cobre em vinhos verdes. Os sensores potenciométricos foram preparados a partir de diferentes solventes (metanol e clorofórmio), tendo o seu crescimento decorrido na presença ou ausência da molécula molde (cobre). Os sistemas sensores selectivos ao cobre continham partículas de polímeros com ou sem impressão molecular como material electroactivo, dispersas em solvente plastificante, PVC e, em alguns casos, aditivo aniónico. A avaliação dos vários sistemas baseou-se na comparação das características operacionais dos diversos eléctrodos onde foram aplicados. Estas características foram obtidas a partir de curvas de calibração, cujos declives e limites de detecção variaram entre -39,9 – 37,0 mV decada-1 e 4,2 – 29,1 μg mL-1, respectivamente. Os sensores não são independentes do pH uma vez que o complexo formado entre o cobre e a difenilcarbazida é favorecido por valores de pH próximos de 5. Assim, obtiveram-se melhores resultados usando água desionizada ou solução tampão de HEPES revelando-se um método rápido e relativamente eficaz nestas condições. Os sensores ópticos basearam-se na reacção colorimétrica entre o cobre e um complexante. Os reagentes complexantes escolhidos foram a neocuproína, a difenilcarbazida e o dietilditiocarbamato de sódio. Avaliou-se o efeito de vários parâmetros experimentais na resposta destes sensores, tais como o pH (avaliado para os valores 3,00 e 5,00), a concentração de cobre (que variou entre 0,06 e 317,7 mg L- 1) e as próprias características da membrana. Os melhores resultados foram obtidos a pH 3, numa gama de concentrações de 0,06 e 31,8 mg L-1 usando a difenilcarbazida como reagente complexante. A aplicação destes sensores a vinhos requer ainda estudos adicionais, especialmente no que diz respeito à necessidade de implementar algum procedimento de pré-tratamento de amostra.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho descreve o desenvolvimento de um material sensor para creatinina por impressão molecular em estrutura polimérica (MIP) e a sua aplicação no desenvolvimento de um dispositivo de natureza potenciométrica para a determinação da molécula alvo em fluidos biológicos. A creatinina é um dos biomarcadores mais utilizados no acompanhamento da doença renal, já que é um bom indicador da taxa de filtração glomerular (TFG). Os materiais biomiméticos desenhados para interação com a creatinina foram obtidos por polimerização radicalar, recorrendo a monómeros de ácido metacríclico ou de vinilpiridina e a um agente de reticulação apropriado. De modo a aferir o efeito da impressão da creatinina na resposta dos materiais MIP à sua presença, foram também preparados e avaliados materiais de controlo, obtidos sem impressão molecular (NIP). O controlo da constituição química destes materiais, incluindo a extração da molécula impressa, foi realizado por Espectroscopia de Raman e de Infravermelho com Transformada de Fourrier. A afinidade de ligação entre estes materiais e a creatinina foi também avaliada com base em estudos cinéticos. Todos os materiais descritos foram integrados em membranas selectivas de elétrodos seletivos de ião, preparadas sem ou com aditivo iónico lipófilo, de carga negativa ou positiva. A avaliação das características gerais de funcionamento destes elétrodos, em meios de composição e pH diferentes, indicaram que as membranas com materiais impressos e aditivo aniónico eram as únicas com utilidade analítica. Os melhores resultados foram obtidos em solução tampão Piperazine-N,N′-bis(2- ethanesulfonic acid), PIPES, de pH 2,8, condição que permitiu obter uma resposta quasi-Nernstiana, a partir de 1,6×10-5 mol L-1. Estes elétrodos demonstraram ainda uma boa selectividade ao apresentaram uma resposta preferencial para a creatinina quando na presença de ureia, carnitina, glucose, ácido ascórbico, albumina, cloreto de cálcio, cloreto de potássio, cloreto de sódio e sulfato de magnésio. Os elétrodos foram ainda aplicados com sucesso na análise de amostras sintéticas de urina, quando os materiais sensores eram baseados em ácido metacrilico, e soro, quando os materiais sensores utilizados eram baseados em vinilpiridina.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O trabalho consistiu no desenvolvimento e caracterização de sensores potenciométricos com base em polímeros de impressão molecular para a determinação de um antibiótico, a norfloxacina, em aquacultura. A simplicidade, o baixo custo e a interação rápida e reversível dos sensores potenciométricos com os analitos fizeram com que este fosse o tipo de sensor escolhido. O material sensor foi obtido por tecnologia de impressão molecular, baseada em polimerização em bulk, em que a NOR foi a molécula molde e foram utilizados como monómeros para autoconstrução dos sensores o pirrol, isoladamente, ou em conjunto com partículas de sílica gel funcionalizadas com 3-aminopropil. Também foi obtido material sensor, para controlo, em que a molécula molde NOR não estava presente (NIP). As características dos materiais sensores foram sujeitas a análise de microscopia eletrónica SEM e análise por espectrómetro de infravermelhos com transformada de Fourier. Os materiais sensores foram incluídos em membranas poliméricas, que seriam incorporadas em elétrodos. A avaliação do desempenho dos elétrodos foi feita através de curvas de calibração em diferentes meios (PBS, MES e HEPES). Também foi efetuada com sucesso a análise da sensibilidade dos elétrodos em água dopada. As diversas avaliações e análises efetuadas levaram a concluir que o MIP de pirrol com aditivo aniónico, foi o material sensor testado que permitiu obter melhores propriedades de resposta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate cancer (PCa) is the most common form of cancer in men, in Europe (World Health Organization data). The most recent statistics, in Portuguese territory, confirm this scenario, which states that about 50% of Portuguese men may suffer from prostate cancer and 15% of these will die from this condition. Its early detection is therefore fundamental. This is currently being done by Prostate Specific Antigen (PSA) screening in urine but false positive and negative results are quite often obtained and many patients are sent to unnecessary biopsy procedures. This early detection protocol may be improved, by the development of point-of-care cancer detection devices, not only to PSA but also to other biomarkers recently identified. Thus, the present work aims to screen several biomarkers in cultured human prostate cell lines, serum and urine samples, developing low cost sensors based on new synthetic biomaterials. Biomarkers considered in this study are the following: prostate specific antigen (PSA), annexin A3 (ANXA3), microseminoprotein-beta (MSMB) and sarcosine (SAR). The biomarker recognition may occurs by means of molecularly imprinted polymers (MIP), which are a kind of plastic antibodies, and enzymatic approaches. The growth of a rigid polymer, chemically stable, using the biomarker as a template allows the synthesis of the plastic antibody. MIPs show high sensitivity/selectivity and present much longer stability and much lower price than natural antibodies. This nanostructured material was prepared on a carbon solid. The interaction between the biomarker and the sensing-material produces electrical signals generating quantitative or semi-quantitative data. These devices allow inexpensive and portable detection in point-of-care testing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IDENTIFICACIÓN DEL PROBLEMA DE ESTUDIO. Las sustancias orgánicas solubles en agua no biodegradables tales como ciertos herbicidas, colorantes industriales y metabolitos de fármacos de uso masivo son una de las principales fuentes de contaminación en aguas subterráneas de zonas agrícolas y en efluentes industriales y domésticos. Las reacciones fotocatalizadas por irradiación UV-visible y sensitizadores orgánicos e inorgánicos son uno de los métodos más económicos y convenientes para la descomposición de contaminantes en subproductos inocuos y/o biodegradables. En muchas aplicaciones es deseable un alto grado de especificidad, efectividad y velocidad de degradación de un dado agente contaminante que se encuentra presente en una mezcla compleja de sustancias orgánicas en solución. En particular son altamente deseables sistemas nano/micro -particulados que formen suspensiones acuosas estables debido a que estas permiten una fácil aplicación y una eficaz acción descontaminante en grandes volúmenes de fluidos. HIPÓTESIS Y PLANTEO DE LOS OBJETIVOS. El objetivo general de este proyecto es desarrollar sistemas nano/micro particulados formados por polímeros de impresión molecular (PIMs) y foto-sensibilizadores (FS). Un PIMs es un polímero especialmente sintetizado para que sea capaz de reconocer específicamente un analito (molécula plantilla) determinado. La actividad de unión específica de los PIMs en conjunto con la capacidad fotocatalizadora de los sensibilizadores pueden ser usadas para lograr la fotodescomposición específica de moléculas “plantilla” (en este caso un dado contaminante) en soluciones conteniendo mezclas complejas de sustancias orgánicas. MATERIALES Y MÉTODOS A UTILIZAR. Se utilizaran técnicas de polimerización en mini-emulsión para sintetizar los sistemas nano/micro PIM-FS para buscar la degradación de ciertos compuestos de interés. Para caracterizar eficiencias, mecanismos y especificidad de foto-degradación en dichos sistemas se utilizan diversas técnicas espectroscópicas (estacionarias y resueltas en el tiempo) y de cromatografía (HPLC y GC). Así mismo, para medir directamente distribuciones de afinidades de unión y eficiencia de foto-degradación se utilizaran técnicas de fluorescencia de molécula/partícula individual. Estas determinaciones permitirán obtener resultados importantes al momento de analizar los factores que afectan la eficiencia de foto-degradación (nano/micro escala), tales como cantidad y ubicación de foto- sensibilizadores en las matrices poliméricas y eficiencia de unión de la plantilla y los productos de degradación al PIM. RESULTADOS ESPERADOS. Los estudios propuestos apuntan a un mejor entendimiento de procesos foto-iniciados en entornos nano/micro-particulados para aplicar dichos conocimientos al diseño de sistemas optimizados para la foto-destrucción selectiva de contaminantes acuosos de relevancia social; tales como herbicidas, residuos industriales, metabolitos de fármacos de uso masivo, etc. IMPORTANCIA DEL PROYECTO. Los sistemas nano/micro-particulados PIM-FS que se propone desarrollar en este proyecto se presentan como candidatos ideales para tratamientos específicos de efluentes industriales y domésticos en los cuales se desea lograr la degradación selectiva de compuestos orgánicos. Los conocimientos adquiridos serán indispensables para construir una plataforma versátil de sistemas foto-catalíticos específicos para la degradación de diversos contaminantes orgánicos de interés social. En lo referente a la formación de recursos humanos, el proyecto propuesto contribuirá en forma directa a la formación de 3 estudiantes de postgrado y 2 estudiantes de grado. En las capacidades institucionales se contribuirá al acondicionamiento del Laboratorio para Microscopía Óptica Avanzada (LMOA) en el Dpto. de Química de la UNRC y al montaje de un sistema de microscopio de fluorescencia que permitirá la aplicación de técnicas avanzadas de espectroscopia de fluorescencia de molecula individual. Water-soluble organic molecules such as certain non-biodegradable herbicides, industrial dyes and metabolites of widespread use drugs are a major source of pollution in groundwater from agricultural areas and in industrial and domestic effluents. Photo-catalytic reactions by UV-visible irradiation and organic sensitizers are one of the most economical and convenient methods for the decomposition of pollutants into harmless byproducts. In many applications it is highly desirable a high degree of specificity, effectiveness and speed of degradation of specific pollutants present in a complex mixture. In particular nano/micro-particles systems that form stable aqueous suspensions are highly desirable because they allow for easy application and effective decontamination of large volumes of fluids. Herein we propose the development of nano/micro particles composed by molecularly imprinted polymers (MIP) and photo-sensitizers (PS). The specific binding of MIP and the photo-catalytic ability of the sensitizers are used to achieve the photo-decomposition of specific "template" molecules in complex mixtures. Mini-emulsion polymerization techniques will be used to synthesize nano/micro MIP-FS systems. Spectroscopy (steady-state and time resolved) and chromatography (GC and HPLC) will be used to characterize efficiency, mechanisms and specificity of photo-degradation in these systems. In addition single molecule/particle fluorescence spectroscopy techniques will be used to directly measure distributions of binding affinities and photo-degradation efficiency in individual particles. The proposed studies point to a more detailed understanding of the factors affecting the photo-degradation efficiency in nano/micro-particles and to apply that knowledge in the design of optimized systems for photo-selective destruction of socially relevant aqueous pollutants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIPs) consist of synthetic macromolecular matrix, obtained through molecular imprinting-based methods that show ability to selectively recognize important biological molecules and its application in the drug delivery field is under development. In the present review the main aspects related to the synthesis and characterization of MIPs are studied. The fundamental variables participating in the synthesis process, such as template molecule, functional monomers, cross-linking agents, solvents and imprinting approaches are discussed. Moreover, the main available methods for MIPs chemical and morphological characterization are presented and the importance of the obtained information is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes selective molecularly imprinted solid-phase extraction of ttMA from urine samples followed by derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). The analytical calibration curve ranged from 0.3 to 7.0 mg L-1 (r = 0.999) and the limit of quantitation (LOQ) was 0.3 mg L-1. The method was applied for the determination of ttMA in urine samples from smokers and concentrations detected ranged from < LOQ to 1.64 mg L-1. Thus, the proposed method proved adequate for the determination of urinary ttMA in the biomonitoring of occupational exposure to low levels of benzene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical imprinting technology has been widely used as a valuable tool in selective recognition of a given target analyte (molecule or metal ion), yielding a notable advance in the development of new analytical protocols. Since their discovery, molecularly imprinted polymers (MIPs) have been extensively studied with excellent reviews published. However, studies involving ion imprinted polymers (IIPs), in which metal ions are recognized in the presence of closely related inorganic ions, remain scarce. Thus, this review involved a survey of different synthetic approaches for preparing ion imprinted adsorbents and their application for the development of solid phase extraction methods, metal ion sensors (electrodes and optodes) and selective membranes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Investigations of 2-alkyl-3-methoxypyrazines (2-isopropyl-3-methoxypyra2ine, 2- secbutyl-3-methoxypyrazine and 2-isobutyl-3-niethoxypyrazine) in ladybug species {Coleoptera: Coccinellidae) and wine samples have been conducted. Headspace sampling coupled with gas chromatography-mass spectrometry was used to determine amounts of 2-alkyl-3-methoxypyra2ines in the ladybug species. Hippodamia convergens had the highest amount of alkybnethoxypyrazines, followed by Harmoma axyridis and the least in Coccinella septempunctata. Using a solvent extraction method, the precoccinelline alkaloid was found present in Hippodamia convergens and Coccinella septempunctata but not Harmonia axyridis. Steam distillation followed by a soHd phase extraction method as a sample preparation technique, enhanced detection while the isotope dilution method afforded accurate quantitation of the alkyknethoxypyrazines in the wine samples. Both ladybug-tainted and commercial wine samples were found to contain the 2- alkyl-3-methoxypyrazines. Wine samples prepared in 2001 generally contained higher levels than the corresponding 2003 samples. Levels of the 2-alkyl-3-methoxypyrazines found in the commercial wines ranged from a minimum value of 6 ng/L to 260 ±10 ng/L. Analyses revealed that for both ladybug species and wine samples, the 2- isopropyl-3-methoxypyrazine had the highest concentration, followed by 2-isobutyl- 3-methoxypyrazine and the least being the 2-secbutyl-3-methoxypyrazine. Possible contamination of the wine samples by ladybugs is thoroughly discussed. Furthermore, attempts to remove or reduce the levels of the alkylmethoxypyrazines with molecularly imprinted polymers from wine samples are presented in detail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical imprinting technology has been widely used as a valuable tool in selective recognition of a given target analyte (molecule or metal ion), yielding a notable advance in the development of new analytical protocols. Since their discovery, molecularly imprinted polymers (MIPs) have been extensively studied with excellent reviews published. However, studies involving ion imprinted polymers (IIPs), in which metal ions are recognized in the presence of closely related inorganic ions, remain scarce. Thus, this review involved a survey of different synthetic approaches for preparing ion imprinted adsorbents and their application for the development of solid phase extraction methods, metal ion sensors (electrodes and optodes) and selective membranes.