962 resultados para metals in urine


Relevância:

100.00% 100.00%

Publicador:

Resumo:

D-lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased D-lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects D-lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect D-lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of L- and D-lactic acid by a two-step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high-performance liquid chromatography-tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic? R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2-400 and 0.5-100 µmol/L respectively for L- and D-lactic acid. The limit of detection of D-lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple method using liquid chromatography-linear ion trap mass spectrometry for simultaneous determination of testosterone glucuronide (TG), testosterone sulfate (TS), epitestosterone glucuronide (EG) and epitestosterone sulfate (ES) in urine samples was developed. For validation purposes, a urine containing no detectable amount of TG, TS and EG was selected and fortified with steroid conjugate standards. Quantification was performed using deuterated testosterone conjugates to correct for ion suppression/enhancement during ESI. Assay validation was performed in terms of lower limit of detection (1-3ng/mL), recovery (89-101%), intraday precision (2.0-6.8%), interday precision (3.4-9.6%) and accuracy (101-103%). Application of the method to short-term stability testing of urine samples at temperature ranging from 4 to 37 degrees C during a time-storage of a week lead to the conclusion that addition of sodium azide (10mg/mL) is required for preservation of the analytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stimulants are banned in-competition for all categories of sports by the World Anti-Doping Agency. A simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay employing electrospray ionisation in positive mode was developed in that work for the quantification in urine specimens of 4-methyl-2-hexaneamine, a primary amine exhibiting sympathomimetic properties. Following a simple pretreatment procedure, the analyte was separated using a gradient mobile phase on reverse phase C8 column. Selected reaction monitoring m/z 116.2-->57.3 was specific for detection of 4-methyl-2-hexaneamine and the assay exhibited a linear dynamic range of 50-700 ng/mL. The validated method has been successfully applied to analyze the target compound in food supplements as well as in urine specimens. The administered drug (40 mg) was detected at the level of 350 ng/mL in the urine up to 4 days.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The quantification of total (free+sulfated) metanephrines in urine is recommended to diagnose pheochromocytoma. Urinary metanephrines include metanephrine itself, normetanephrine and methoxytyramine, mainly in the form of sulfate conjugates (60-80%). Their determination requires the hydrolysis of the sulfate ester moiety to allow electrochemical oxidation of the phenolic group. Commercially available urine calibrators and controls contain essentially free, unhydrolysable metanephrines which are not representative of native urines. The lack of appropriate calibrators may lead to uncertainty regarding the completion of the hydrolysis of sulfated metanephrines, resulting in incorrect quantification. METHODS: We used chemically synthesized sulfated metanephrines to establish whether the procedure most frequently recommended for commercial kits (pH 1.0 for 30 min over a boiling water bath) ensures their complete hydrolysis. RESULTS: We found that sulfated metanephrines differ in their optimum pH to obtain complete hydrolysis. Highest yields and minimal variance were established for incubation at pH 0.7-0.9 during 20 min. CONCLUSION: Urinary pH should be carefully controlled to ensure an efficient and reproducible hydrolysis of sulfated metanephrines. Synthetic sulfated metanephrines represent the optimal material for calibrators and proficiency testing to improve inter-laboratory accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diplomityön tarkoituksena oli löytää keino korkean mangaanipitoisuuden hallintaan ECF-valkaisussa. Kirjallisuusosassa käsiteltiin eri metallien ja kuidun vuorovaikutuksia sekä niiden vaikutuksia prosessiin. Lisäksi käytiin läpi sellunvalmituksen yleisimpiä metallienhallintamenetelmiä. Työn kokeellisessa osassa tehtiin esikokeina laboratoriokokeita, jotta löydettiin oikeat kelatointistrategiat tehdasmittakaavan koeajoille. Laboratoriovalkaisut suoritettiin kuudella eri kemikaalilla käyttäen DD3-pesurin jälkeistä massaa ja samanlaisia parametrejä kuin tehdasvalkaisussa. Kolmesta eri valkaisusekvenssistä paras tulos saavutettiin D0-QEP-sekvenssillä. Tehdasmittakaavan koeajojen tavoitteena oli saavuttaa alle 1 mg/kg jäännösmangaanipitoisuus valkaistussa massassa ja korkeampi vaaleus EOP-vaiheessa pienemmällä klooridioksidin kulutuksella. Koeajoissa käytettiinDTPA:ta ja EDTA:ta kahdeksassa eri koepisteessä. Pienimpiin jäännöspitoisuuksiin päästiin koepisteissä, joissa kelatointiaine annosteltiin ennen valkaisun viimeistä pesuvaihetta tai sen jälkeen. Samanlaisia tuloksia saavutettiin koepisteissä, joissa kelatointiaine lisättiin suoraan EOP-vaiheeseen. Tällöin kelatointiaineen käyttö johti myös korkeampaan vaaleuteen EOP-vaiheessa pienemmällä kappakertoimella kuin referenssissä. Säästöt klooridioksidin kulutuksessa eivät olleet kuitenkaan tarpeeksi suuret kattaakseen kelatointiaineiden käytön kustannuksia. Kustannustehokkain tapa kontrolloida jäännösmangaanipitoisuutta oli EDTA:n annostelu D2 DD-pesurin jälkeen. Haittapuolena tälläisessä kelatoinnissa oli metallikompleksien palautuminen valkaisuun kuivauskoneen kiertoveden mukana. Tärkeimmät onnistuneeseen kelatointiin vaikuttavat parametrit olivat lajittelussa käytetyn rikkihapon annos, D0-vaiheen pH ja D0 DD-pesurin pesutehokkuus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Streams located in areas of sugar cane cultivation receive elevated concentrations of metal ions from soils of adjacent areas. The accumulation of metals in the sediments results in environmental problems and leads to bioaccumulation of metal ions by the aquatic organisms. In the present study, bioaccumulation of the metals ions Al, Cd, Cr, Cu, Fe, Mg, Mn and Zn in aquatic insects in streams impacted by the sugar cane was evaluated. The results pointed out that the insects were contaminated by the sediment and that the collector organisms as Chironomus species accumulated higher concentration of metals than the predator organisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, sensitive and selective cloud point extraction procedure is described for the preconcentration and atomic absorption spectrometric determination of Zn2+ and Cd2+ ions in water and biological samples, after complexation with 3,3',3",3'"-tetraindolyl (terephthaloyl) dimethane (TTDM) in basic medium, using Triton X-114 as nonionic surfactant. Detection limits of 3.0 and 2.0 µg L-1 and quantification limits 10.0 and 7.0 µg L-1were obtained for Zn2+ and Cd2+ ions, respectively. Relative standard deviation was 2.9 and 3.3, and enrichment factors 23.9 and 25.6, for Zn2+ and Cd2+ ions, respectively. The method enabled determination of low levels of Zn2+ and Cd2+ ions in urine, blood serum and water samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The made research is focused on possibility of application of non ferrous metals in boiler pressure parts as a substitute of currently used ferrous-base alloys. The main issue was to define resistive ability of some perspective non ferrous metals to chlorine induced corrosion. Experimental study was performed using simultaneous thermal analysis (STA) in the temperature range of 400-700 °C. The chloride induced corrosion was simulated by mixtures of metal samples with potassium chloride treated by synthetic air. The advantage of synergetic effect of non ferrous alloys compare to single metals is shown due to the obtained data from conducted thermal balance tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: The concentration of heavy metals (Cr, Fe, Al, As, Cd, Cu, Pb, Mo, Ni, Se and Zn) was evaluated in the blood of nestling blue macaws (Anodorhynchus hyacinthinus) captured in the Pantanal, Mato Grosso do Sul (n=26) in 2012; this was based on the hypothesis that these birds exhibit levels of these heavy metals in their organism and that these interfere in hatching success, weight and age of the chicks. Blood samples were digested with nitric acid and hydrochloric acid and the quantification of metals was performed by ICP-OES (Optical Emission Spectroscopy and Inductively Coupled Plasma). Blood samples of nestlings showed concentrations of Cr (0.10μg/g) Fe (3.06μg/g) Al (3.46μg/g), Cd (0.25μg/g) Cu (0.74μg/g), Mo (0.33μg/g), Ni (0.61μg/g), Se (0.98μg/g), and Zn (2.08μg/g). The levels of heavy metals found were not associated with weight, age and hatching success of the chicks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diabetic nephropathy (DN) is characterized structurally by progressive mesangial deposition of extracellular matrix (ECM). Transforming growth factor-ß (TGF-ß) is considered to be one of the major cytokines involved in the regulation of ECM synthesis and degradation. Several studies suggest that an increase in urinary TGF-ß levels may reflect an enhanced production of this polypeptide by the kidney cells. We evaluated TGF-ß in occasional urine samples from 14 normal individuals and 23 patients with type 2 diabetes (13 with persistent proteinuria >500 mg/24 h, DN, 6 with microalbuminuria, DMMA, and 4 with normal urinary albumin excretion, DMN) by enzyme immunoassay. An increase in the rate of urinary TGF-ß excretion (pg/mg UCreat.) was observed in patients with DN (296.07 ± 330.77) (P<0.001) compared to normal individuals (17.04 ± 18.56) (Kruskal-Wallis nonparametric analysis of variance); however, this increase was not observed in patients with DMMA (25.13 ± 11.30) or in DMN (18.16 ± 11.82). There was a positive correlation between the rate of urinary TGF-ß excretion and proteinuria (r = 0.70, a = 0.05) (Pearson's analysis), one of the parameters of disease progression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a new simple, selective and sensitive micromethod based on HPLC and fluorescence detection to measure debrisoquine (D) and 4-hydroxydebrisoquine (4-OHD) in urine for the investigation of xenobiotic metabolism by debrisoquine hydroxylase (CYP2D6). Four hundred µl of urine was required for the analysis of D and 4-OHD. Peaks were eluted at 8.3 min (4-OHD), 14.0 min (D) and 16.6 min for the internal standard, metoprolol (20 µg/ml). The 5-µm CN-reverse-phase column (Shimpack, 250 x 4.6 mm) was eluted with a mobile phase consisting of 0.25 M acetate buffer, pH 5.0, and acetonitrile (9:1, v/v) at 0.7 ml/min with detection at lexcitation = 210 nm and lemission = 290 nm. The method, validated on the basis of measurements of spiked urine, presented 3 ng/ml (D) and 6 ng/ml (4-OHD) sensitivity, 390-6240 ng/ml (D) and 750-12000 ng/ml (4-OHD) linearity, and 5.7/8.2% (D) and 5.3/8.2% (4-OHD) intra/interassay precision. The method was validated using urine of a healthy Caucasian volunteer who received one 10-mg tablet of Declinax®, po, in the morning after an overnight fast. Urine samples (diuresis of 4 or 6 h) were collected from zero to 24 h. The urinary excretion of D and 4-OHD, Fel (0-24 h), i.e., fraction of dose administered and excreted into urine, was 6.4% and 31.9%, respectively. The hydroxylation capacity index reported as metabolic ratio was 0.18 (D/4-OHD) for the person investigated and can be compared to reference limits of >12.5 for poor metabolizers (PM) and <12.5 for extensive metabolizers (EM). In parallel, the recovery ratio (RR), another hydroxylation capacity index, was 0.85 (4-OHD: SD + 4-OHD) versus reference limits of RR <0.12 for PM and RR >0.12 for EM. The healthy volunteer was considered to be an extensive metabolizer on the basis of the debrisoquine test.