423 resultados para interferences
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
For the first time, a glassy carbon electrode (GCE) modified with novel N-doped carbon nanotubes (CNT-N) functionalized with MnFe2O4 nanoparticles (MnFe2O4@CNT-N) has been prepared and applied for the electrochemical determination of caffeine (CF), acetaminophen (AC) and ascorbic acid (AA). The electrochemical behaviour of CF, AC and AA on the bare GCE, CNT-N/GCE and MnFe2O4@CNT-N/GCE were carefully investigated using cyclic voltammetry (CV) and square-wave voltammetry (SWV). Compared to bare GCE and CNT-N modified electrode, the MnFe2O4@CNT-N modified electrode can remarkably improve the electrocatalytic activity towards the oxidation of CF, AC and AA with an increase in the anodic peak currents of 52%, 50% and 55%, respectively. Also, the SWV anodic peaks of these molecules could be distinguished from each other at the MnFe2O4@CNT-N modified electrode with enhanced oxidation currents. The linear response ranges for the square wave voltammetric determination of CF, AC and AA were 1.0 × 10−6 to 1.1 × 10−3 mol dm−3, 1.0 × 10−6 to 1.0 × 10−3 mol dm−3 and 2.0 × 10−6 to 1.0 × 10−4 mol dm−3 with detection limit (S/N = 3) of 0.83 × 10−6, 0.83 × 10−6 and 1.8 × 10−6 mol dm−3, respectively. The sensitivity values at the MnFe2O4@CNT-N/GCE for the individual determination of AC, AA and CF and in the presence of the other molecules showed that the quantification of AA and CF show no interferences from the other molecules; however, AA and CF interfered in the determination of AC, with the latter molecule showing the strongest interference. Nevertheless, the obtained results show that MnFe2O4@CNT-N composite material acted as an efficient electrochemical sensor towards the selected biomolecules.
Resumo:
The development and application of a polyaniline/carbon nanotube (CNT) cyclodextrin matrix (PANI-β-CD/MWCNT)-based electrochemical sensor for the quantitative determination of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA) and its main transformation product 4-chloro-2-methylphenol in natural waters are described. A simple cyclic voltammetry-based electrochemical methodology, in phosphate buffer solution at pH 6.0, was used to develop a method to determine both MCPA and 4-chloro-2-methylphenol, without any previous extraction or derivatization steps. A linear concentration range (10 to 50 μmol L−1) and detection limits of 1.1 and 1.9 μmol L−1, respectively, were achieved using optimized cyclic voltammetric parameters. The proposed method was successfully applied to the determination of MCPA and 4-chloro-2-methylphenol in natural water samples with satisfactory recoveries (94 to 107 %) and in good agreement with the results obtained by an established high-performance liquid chromatography technique, no significant differences being found between the methods. Interferences from ionic species and other herbicides used for broad-leaf weed control were shown to be small. The newly developed methodology was also successfully applied to MCPA photodegradation environmental studies.
Resumo:
RESUMO: A Diabetes Mellitus é uma doença metabólica crónica, com deficiência a nível do metabolismo dos hidratos de carbono, lípidos e proteínas, resultante de deficiências na secreção ou ação da insulina, ou de ambas, que quando não tratada antecipadamente e de modo conveniente, pode ter consequências muito graves. Dado a incidência a nível mundial da Diabetes Mellitus, torna-se de elevada importância avaliar toda a sua envolvência e estudar bem quais os critérios a ter em consideração. Este trabalho propõe-se estudar para além dos parâmetros bioquímicos relacionados com a doença - Glicose e Hemoglobina Glicada A1c (HbA1c), analisar os resultados dos últimos cinco anos (2008-2012) dos ensaios interlaboratoriais do PNAEQ, do Departamento de Epidemiologia, do Instituto Nacional de Saúde Dr. Ricardo Jorge. Foram também analisadas as metodologias utilizadas e as variações interlaboratoriais, de forma a entender qual ou quais são os parâmetros mais adequados para o seu diagnóstico e controlo. Este estudo utilizou a população de laboratórios portugueses, públicos e privados, de Portugal Continental e Ilhas, um laboratório de Angola e outro de Macau que se inscreveram no PNAEQ nestes cinco anos, sendo a amostra composta pelo n.º de participações. No programa de Química Clinica foram distribuídas 38 amostras e no programa de HbA1c foram distribuídas 22 amostras. Para a glicose, o nível de desempenho nos ensaios é na globalidade das amostras de Excelente, no entanto verifica-se que sempre que a concentração da amostra é de nível patológico, que a maioria dos ensaios o desempenho foi inferior – Bom. O método de eleição e com CV% mais baixos foi o método da hexoquinase. Para a HbA1c, o nível de desempenho nos ensaios é na globalidade das amostras de Excelente. O método de eleição e com CV% mais baixos foi o método de HPLC. O CV% para a glicose ronda desde 2010 a 2012, os 3% e para a HbA1c foi de aproximadamente 4,0% em 2012. A HbA1c tem mostrado ser uma ferramenta muito útil, importante e robusta na monitorização da Diabetes, sendo hoje em dia quase sempre requisitada em análises de rotina a diabéticos de modo a prevenir complicações que possam vir a acorrer. No futuro poderá ser um importante, senão o parâmetro de futuro, para o diagnóstico da Diabetes, no entanto, mesmo já tendo sido muito trabalhada a sua padronização, ainda existem questões por responder como quais são na realidade todos os seus interferentes, qual a verdadeira relação da HbA1c com a glicose média estimada, em todas as populações e com estudos epidemiológicos. Também a própria educação do diabético e clínico deve ser aprimorada, pelo que neste momento as PTGO e os doseamentos de glicose em jejum devem ser utilizados e encontrando-se a Norma da DGS N.º 033/2011 de acordo com as necessidades e com o estado da arte deste parâmetro. A implementação da glicose média estimada será uma mais-valia na monitorização dos diabéticos pelo que deverá ser uma das prioridades a ter em conta no futuro desta padronização, uniformizando a decisão clinica baseada nela e minimizando a dificuldade de interpretação de resultados de laboratório para laboratório. --------------ABSTRACT: Diabetes Mellitus is a chronic metabolic disease, with a deficit in the metabolism of carbohydrates, lipids and proteins, resulting from deficiencies in insulin secretion or action, or both, which if, when not early treated in a proper way, may result in very serious consequences. Given the worldwide incidence of diabetes mellitus, it is highly important to evaluate all its background and study specifically all the criteria to take into consideration. The aim of this thesis is to study and evaluate beyond the biochemical parameters related to the disease - Glucose and Glycated Haemoglobin A1c (HbA1c), analyze the results of the last five years (2008-2012) of the PNAEQ interlaboratorial tests, in the Department of Epidemiology of National Institute of Health Dr. Ricardo Jorge. It is also intended to analyze the methodologies used and the interlaboratorial variations, in order to understand the most suitable parameters for the diagnosis and control. This study was based in a population of Portuguese laboratories, public and private, of Portugal mainland and islands, a laboratory of Angola and other from Macau, who enrolled in PNAEQ in these five years, and the sample was composed by the n. º of holdings. In the Clinical Chemistry Program there were distributed 38 samples and in the program HbA1c were distributed 22 samples. For glucose, the level of performance in the total nº of the samples was Excellent; however, it was found that when the concentration level of the sample was pathological, in most of the tests the performance was Good. The most preferred method with the lowest CV% is the hexokinase method. For the HbA1c, as a whole, the samples’ tests were Excellent, at the level of performance. The method of election with the lower CV% was the HPLC. The CV% for glucose was around 3%, from 2010 to 2012 and the HbA1c was approximately 4.0% in 2012. The HbA1c method has demonstrated to be a very useful tool, important and robust for monitoring diabetes, being nowadays, almost always required in routine analysis to prevent future complications. In the future it may be an important parameter, if not the most important, for the diagnosis of diabetes. However, despite it has already been standardized, there are still some questions that need to be answered, such as, which are in fact all their interferences, which is the true connection of HbA1c, when compared with the estimated average glucose, in all populations and epidemiological studies. Moreover, the education of the patient and the doctor concerning diabetes should be improved. Nowadays, the Oral Glucose Tolerance Test (OGTT) and fasting glucose determinations should be used and, the needs and the state of the art of this parameter, should be in accordance with the Standard DGS N. º 033/2011. The Implementation of the estimated average glucose will be an added value in monitoring diabetics and, therefore, should be a priority to consider in its future standardization and clinical decision based on it, will be uniform and the difficulty of interpreting results from laboratory to laboratory will be minimal.
Resumo:
RESUMO: O impacto da fase pré-analítica nos resultados é o objectivo do nosso trabalho. Considera-se que esta fase é a mais importante no procedimento do teste no laboratório e que as variáveis independentes do laboratório são difíceis de controlar porque existem várias condicionantes quer dos profissionais, quer do doente, que por vezes não possibilita atribuir a importância desejada para que os resultados sejam fiáveis. De que modo a fase pré-analítica pode interferir nos resultados de um trabalho de investigação. Para podermos avaliar este processo é necessário considerar outra condicionante, nomeadamente, o facto de o teste ser realizado em laboratórios específicos com a qualidade certificada mas que não intervêm na colheita, manuseamento, armazenamento e transporte da amostra, procedimentos importantes que traduzem uma boa gestão da amostra na fase pré-analítica, necessária para a fiabilidade dos resultados dos estudos de investigação clínica.------------------ABSTRACT: The impact of pre-analytical phase in the results is the objective of our work Knowing that, this is the most important stage in the procedure of testing in the laboratory and because the independent variables the laboratory are difficult to control because these are several limitations of both the professional and the patient, sometimes does not assign importance to that desired result are reliable. How the pre-analytical phase can interfere with the result of a research work, there is another constraint to consider the testing process to be performed in individual laboratory with certified quality, but not involved in harvesting, handing, storage and transport of the sample, important procedures that translate a good sample management in the preanalytical phase, necessary for the reliability of results of clinical research studies.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
A situação linguística de muitos países africanos é caracterizada por um contacto permanente das línguas locais com o Português trazido pelo colonizador. No caso de Angola, esta última língua foi imposta sob pretexto de “civilizar” os autóctones. Por conseguinte, mesmo se o poder público tem envidado esforços com vista a valorizálas, porquanto elas constituem um património de suma importância, essas línguas continuam sendo marginalizadas em detrimento do Português, a única língua oficial do país. No entanto, sabe-se que o contacto do Português com aquelas línguas e mormente com o Umbundu provoca fenómeno de empréstimos interlinguísticos, surgindo aquilo que se pode designar de “ umbundismos” e de “portuguesismos”. Este trabalho demonstra portanto este fenómeno a partir de análise de muitos lexemas que se manifestam na antroponímia, toponímia assim como em várias áreas da vida ovimbundu. Esta reflexão culmina na proposta da criação de um Dicionário de Umbundismos com vista à fixação e à inovação do léxico da variante do Português angolano.
Resumo:
The organic and inorganic forms of soil nitrogen and how they participate in the process of fixation, immobilization and mineralization of ammonium in soils were evaluated, after different periods of incubaton, utilizing two soils, a Lithic Haplustoll and a Typic Eutrorthox. The results obtained permit to suggest that : 1) The method for determination of the ammonium fixing capacity based on the extraction with 2N KC1, is considered to be subject to interferences of other soil fractions capable of retaining ammonium. 2) The increase in exchangeable ammonium content is related to the decrease in amino acids and hydrolyzable ammonium. 3) The immobilization and mineralization processes are still held under mil microbial. The forms more affected by this condition are amino acids and hydrolyzable ammonium.
Resumo:
The reversals of Mitsuda's reactions induced by BCG have been objected to based on the possiblem interference of other determination causes of the phenomenon: tuberculous primo-infections, communicants of unsuspected leprosy, revearsals due to other causes, such as anti-diphteric and anti-tetanic vaccination, etc. In order to study the problem, we have used Rhesus monkeys (Macaca mulatta), which were reared in isolation, in an attempt to avoid the referred to interferences. Prior to the experiments, all animals were tested and found negative to radiograph, tuberculin and lepromin tests and were then submitted to the application of BCG vaccine (from 1 to 3 days old), in different doses and by different via. At different times, after the application of BCG, they were again submitted to the radiographic, tuberculin and lepromin tests. In the tables I to IV the experiences were summarised. From the experiments, the following conclusions were reached: 1 - From 12 Rhesus that received BCG 11 showed reversals of the Mitsuda reaction (91.7%). 2 - These reverseals took place both in tests effected shortly after BCG (from 6 days to 2 months), and tests effected much later (from 7 to 12 months after BCG). 3 - Some differences were found in the results, according to the dosis and the application via of the BCG. a) - The testicular and peritonela via (0,02g) were the only that determined strong positive Mitsuda's reactions (+++). b) - By oral via, animals that received high dosis (0.6g and 1.2 g), there resulted uniform and regular reversals, even though of low intensity (+); but from those who got small doses (0.2 g.) one showed no reversals in all tests, and the other presented reversals in the 2nd and 3rd tests only, also with low positivity (+). 4) In the 2nd and 3rd Mitsuda's reactions in the same animals, positivity was always precocious (generally within 48 hours), one getting the impression that there occurs a sensibilization of the animal body by the antigen with the repetition of the tests, even though the intensity of the reaction always remains the same. This precocious reaction (Fernandez type) occurs both shortly and long time after the application of the BCG. Its precocity depends not of the antigen only because the first Mitsuda's reaction after the BCG application occurs after some time and seems not influenced by the control lepromin test effected on the Rhesus before the BCG. 5) On the control group, the animals which received a.a.f. bacilli suspensions (Mycobacterium sp.; M. avium, and M. smegmatis), did not show reverseals of the Mitsuda's reaction. Two Rhesus, however, which received dead BCG (120ºC autoclave 1 hour), one intradermically (0.006 g) and the other orally (1.2 g), did both present reversals of the Mitsuda's reaction, with weak positivity (+). In all animals of the control-group, the allergic reactions were found negative. 6) Strong local inflammatory reactions were observed in the Rhesus that had received living BCG by intradermal via, and in the one submitted to multipunctures, there occurred the formation of a large caseous abcess. 7) The allergic tuberculinic and infratuberculinic reactions appeared dissociated from the Mitsuda's reactions: sometimes they are more precocious, occurring before of the lepromin test; on other occasions they disappear, when the Mitsuda's reactions still persist; and finally, they may be absent, when the latter occur, especially after the oral application of the BCG. 8) In Rhesus which received BCG by testicular and peritonela via, in the infratuberculinic test (0.1 ml of total BCG extract), besides the classic answer, which occurs between 48 and 96 hours, one could observe a delayed answer (15 to 20 days), represented by a non-erythematous nodule, which persists for 11-14 days.
Resumo:
An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.
Resumo:
A gas chromatography-mass spectrometry (GC-MS) method is presented which allows the simultaneous determination of the plasma concentrations of the levo-alpha-acetylmethadol (LAAM) and of its active metabolites (NorLAAM and DiNorLAAM), after derivatization with the reagent trifluoroacetic anhydride (TFAA). No interferences from endogenous compounds were observed following the extraction of plasma samples from 11 different human subjects. The standard curves were linear over a working range of 5-200ng/ml for the three compounds. Recoveries measured at three concentrations ranged from 47 to 67% for LAAM, from 50 to 69% for NorLAAM and from 28 to 50% for DiNorLAAM. Intra- and interday coefficients of variation determined at three concentrations ranged from 5 to 13% for LAAM, from 3 to 9% for NorLAAM and from 5 to 13% for DiNorLAAM. The limits of quantitation of the method were found to be 4ng/ml for the three compounds. No interference was noted from methadone. This sensitive and specific analytical method could be useful for assessing the in vivo relationship between LAAM's blood levels, clinical efficacy and/or cardiotoxicity
Resumo:
L’explosió del sector turístic experimentat en les costes catalanes des de principis dels anys 60 ha provocat un important impacte sobre el medi litoral català i el seu principal atractiu turístic, les platges. Sitges és un municipi annex a una important zona urbana (Barcelona), i s'ofereix com a indret de segona residència i ciutat de vacances, sobretot a l’estiu, incrementant fortament la pressió sobre el medi. L'objectiu principal d'aquest projecte ha estat estudiar les pertorbacions sobre alguns aspectes del sistema litoral Sitgetà: el perfil litoral i la dinàmica sedimentària, la qualitat microbiològica de les aigües i la sorra, els cabals d'aigües residuals tractades i els residus de les platges. A partir dels registres de neteja en platges, proposem el rebuig i envasos en sorra (concentració de residus, kg/m2) com a nou indicador de presència d’usuaris a les platges (usuaris/m2). La diagnosi realitzada indica que l'estat físic de les platges de Sitges respon a les actuacions en matèria d'obres marítimes en interacció amb les dinàmiques sedimentaries. Pel que fa als anàlisis microbiològics de l'aigua i la sorra trobem una situació regulada a excepció de pics provocats per pluges puntuals. Malauradament hem vist com es podrien potenciar el valors ambientals de totes les parts treballades si es fomentessin figures de protecció del medi, la regeneració d’espècies vegetals tan fora com dins de l'aigua i es garantís una gestió de l’aigua 100% eficient i sense causar intromissions en el desenvolupament dels ecosistemes.
Resumo:
Als darrers anys la necessitat de connectar-se a internet des de qualsevol lloc s’ha incrementat exponencialment sobretot de manera inalàmbrica. Degut al finit espectre radioelèctric es tendeix a aprofitar totes les franges freqüencials d’aquest convivint diferents sistemes en franges properes podent induir-se interferències mútuament. Per evitar aquestes interferències es requereix de filtres a tots els dispositius els quals aïllin un sistema del adjacent. En aquest projecte es dóna una solució al cas concret de la convivència entre els sistemes Wi-Fi y WiMAX eliminant la banda Wi-Fi interferent en sistemes WiMAX. Aquesta solució consisteix en el disseny d’un filtre banda eliminada d’ordre 3 implementat mitjançant tecnologia BAW a partir de l’estructura y especificacions d’un filtre comercial. A més també es fa un petit estudi per veure si seria interessant una millora en els processos de fabricació del filtre per part del fabricant.
Resumo:
BACKGROUND: In contrast to mammalian erythrocytes, which have lost their nucleus and mitochondria during maturation, the erythrocytes of almost all other vertebrate species are nucleated throughout their lifespan. Little research has been done however to test for the presence and functionality of mitochondria in these cells, especially for birds. Here, we investigated those two points in erythrocytes of one common avian model: the zebra finch (Taeniopygia guttata). RESULTS: Transmission electron microscopy showed the presence of mitochondria in erythrocytes of this small passerine bird, especially after removal of haemoglobin interferences. High-resolution respirometry revealed increased or decreased rates of oxygen consumption by erythrocytes in response to the addition of respiratory chain substrates or inhibitors, respectively. Fluorometric assays confirmed the production of mitochondrial superoxide by avian erythrocytes. Interestingly, measurements of plasmatic oxidative markers indicated lower oxidative stress in blood of the zebra finch compared to a size-matched mammalian model, the mouse. CONCLUSIONS: Altogether, those findings demonstrate that avian erythrocytes possess functional mitochondria in terms of respiratory activities and reactive oxygen species (ROS) production. Interestingly, since blood oxidative stress was lower for our avian model compared to a size-matched mammalian, our results also challenge the idea that mitochondrial ROS production could have been one actor leading to this loss during the course of evolution. Opportunities to assess mitochondrial functioning in avian erythrocytes open new perspectives in the use of birds as models for longitudinal studies of ageing via lifelong blood sampling of the same subjects.