958 resultados para index method
Resumo:
The crosstalk phenomenon consists in recording the volume-conducted electromyographic activity of muscles other than that under study. This interference may impair the correct interpretation of the results in a variety of experiments. A new protocol is presented here for crosstalk assessment between two muscles based on changes in their electrical activity following a reflex discharge in one of the muscles in response to nerve stimulation. A reflex compound muscle action potential (H-reflex) was used to induce a silent period in the muscle that causes the crosstalk, called here the remote muscle. The rationale is that if the activity recorded in the target muscle is influenced by a distant source (the remote muscle) a silent period observed in the electromyogram (EMG) of the remote muscle would coincide with a decrease in the EMG activity of the target muscle. The new crosstalk index is evaluated based on the root mean square (RMS) values of the EMGs obtained in two distinct periods (background EMG and silent period) of both the remote and the target muscles. In the present work the application focused on the estimation of the degree of crosstalk from the soleus muscle to the tibialis anterior muscle during quiet stance. However, the technique may be extended to other pairs of muscles provided a silent period may be evoked in one of them. (C) 2009 IPEM. Published by Elsevier Ltd. All rights reserved.
Resumo:
The leaf area index (LAI) of fast-growing Eucalyptus plantations is highly dynamic both seasonally and interannually, and is spatially variable depending on pedo-climatic conditions. LAI is very important in determining the carbon and water balance of a stand, but is difficult to measure during a complete stand rotation and at large scales. Remote-sensing methods allowing the retrieval of LAI time series with accuracy and precision are therefore necessary. Here, we tested two methods for LAI estimation from MODIS 250m resolution red and near-infrared (NIR) reflectance time series. The first method involved the inversion of a coupled model of leaf reflectance and transmittance (PROSPECT4), soil reflectance (SOILSPECT) and canopy radiative transfer (4SAIL2). Model parameters other than the LAI were either fixed to measured constant values, or allowed to vary seasonally and/or with stand age according to trends observed in field measurements. The LAI was assumed to vary throughout the rotation following a series of alternately increasing and decreasing sigmoid curves. The parameters of each sigmoid curve that allowed the best fit of simulated canopy reflectance to MODIS red and NIR reflectance data were obtained by minimization techniques. The second method was based on a linear relationship between the LAI and values of the GEneralized Soil Adjusted Vegetation Index (GESAVI), which was calibrated using destructive LAI measurements made at two seasons, on Eucalyptus stands of different ages and productivity levels. The ability of each approach to reproduce field-measured LAI values was assessed, and uncertainty on results and parameter sensitivities were examined. Both methods offered a good fit between measured and estimated LAI (R(2) = 0.80 and R(2) = 0.62 for model inversion and GESAVI-based methods, respectively), but the GESAVI-based method overestimated the LAI at young ages. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
We demonstrate tomographic imaging of the refractive index of turbid media using bifocal optical coherence refractometry (BOCR). The technique, which is a variant of optical coherence tomography, is based on the measurement of the optical pathlength difference between two foci simultaneously present in a medium of interest. We describe a new method to axially shift the bifocal optical pathlength that avoids the need to physically relocate the objective lens or the sample during an axial scan, and present an experimental realization based on an adaptive liquid-crystal lens. We present experimental results, including video clips, which demonstrate refractive index tomography of a range of turbid liquid phantoms, as well as of human skin in vivo.
Resumo:
In recent work, the concentration index has been widely used as a measure of income-related health inequality. The purpose of this note is to illustrate two different methods for decomposing the overall health concentration index using data collected from a Short Form (SF-36) survey of the general Australian population conducted in 1995. For simplicity, we focus on the physical functioning scale of the SF-36. Firstly we examine decomposition 'by component' by separating the concentration index for the physical functioning scale into the ten items on which it is based. The results show that the items contribute differently to the overall inequality measure, i.e. two of the items contributed 13% and 5%, respectively, to the overall measure. Second, to illustrate the 'by subgroup' method we decompose the concentration index by employment status. This involves separating the population into two groups: individuals currently in employment; and individuals not currently employed. We find that the inequality between these groups is about five times greater than the inequality within each group. These methods provide insights into the nature of inequality that can be used to inform policy design to reduce income related health inequalities. Copyright (C) 2002 John Wiley Sons, Ltd.
Resumo:
Chronic hepatitis C (CHC) is one of the most important causes of chronic liver disease in the world, potentially resulting in cirrhosis, hepatocellular carcinoma, and the need for liver transplantation. Liver biopsy is currently performed before therapy indication. Although, it is the golden standard there are many reasons to avoid or delay the procedure. APRI Score is an easy, low cost and practice alternative method which was described as an alternative for assessing structural changes in chronic hepatitis C (CHC). The rationale of this study was to observe the accuracy of APRI Score in comparison to liver biopsy in 400 patients divided into two groups of 200 carriers (Validation and Experimental groups respectively) selected at random or according to liver fibrosis staging (METAVIR). The ROC curves showed a concordance among these two methods of 92% and 88.5% when 1.05 was the cut off (F3 and F4), and 87% and 83%, on 0.75 cut offs (F2-F4). The discordance in advanced fibrosis staging (F3 and F4) was only 16 (8%) and 22 (11%) out of 200 patients in the experimental and validation groups, respectively. In 26 (13%) out of 200 patients in the experimental group and 34 (17%) out of 200 patients in the validation group, there was discordance between APRI Score and liver biopsy in moderate and advanced fibrosis (F2-F4). In conclusion APRI is a serological marker that has satisfactory sensitivity and specificity together with a high predictive value and it can be useful either in the absence of a biopsy or to reduce the frequency with which biopsies need to be carried out to monitor the evolution of chronic hepatitis C and the right moment for treatment indication.
Resumo:
Recent studies have demonstrated that spatial patterns of fMRI BOLD activity distribution over the brain may be used to classify different groups or mental states. These studies are based on the application of advanced pattern recognition approaches and multivariate statistical classifiers. Most published articles in this field are focused on improving the accuracy rates and many approaches have been proposed to accomplish this task. Nevertheless, a point inherent to most machine learning methods (and still relatively unexplored in neuroimaging) is how the discriminative information can be used to characterize groups and their differences. In this work, we introduce the Maximum Uncertainty Linear Discrimination Analysis (MLDA) and show how it can be applied to infer groups` patterns by discriminant hyperplane navigation. In addition, we show that it naturally defines a behavioral score, i.e., an index quantifying the distance between the states of a subject from predefined groups. We validate and illustrate this approach using a motor block design fMRI experiment data with 35 subjects. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
The Sciatic Functional Index (SFI) is a quite useful tool for the evaluation of functional recovery of the sciatic nerve of rats in a number of experimental injuries and treatments. Although it is an objective method, it depends on the examiner`s ability to adequately recognize and mark the previously established footprint key points, which is an entirely subjective step, thus potentially interfering with the calculations according to the mathematical formulae proposed by different authors. Thus, an interpersonal evaluation of the reproducibility of an SFI computer-aided method was carried out here to study data variability. A severe crush injury was produced on a 5 mm-long segment of the right sciatic nerve of 20 Wistar rats (a 5000 g load directly applied for 10 min) and the SH was measured by four different examiners (an experienced one and three newcomers) preoperatively and at weekly intervals from the 1st to the 8th postoperative week. Three measurements were made for each print and the average was calculated and used for statistical analysis. The results showed that interpersonal correlation was high (0.82) in the 3rd, 4th, 5th, 7th and 8th weeks, with an unexpected but significant (p < 0.01) drop in the 6th week. There was virtually no interpersonal correlation (correlation index close to 0) on the 1st and 2nd weeks, a period during which the variability between animals and examiners (p =0.24 and 0.32, respectively) was similar, certainly due to a poor definition of the footprints. The authors conclude that the SFI method studied here is only reliable from the 3rd week on after a severe lesion of the sciatic nerve of rats. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Objective: Several limitations of published bioelectrical impedance analysis (BIA) equations have been reported. The aims were to develop in a multiethnic, elderly population a new prediction equation and cross-validate it along with some published BIA equations for estimating fat-free mass using deuterium oxide dilution as the reference method. Design and setting: Cross-sectional study of elderly from five developing countries. Methods: Total body water (TBW) measured by deuterium dilution was used to determine fat-free mass (FFM) in 383 subjects. Anthropometric and BIA variables were also measured. Only 377 subjects were included for the analysis, randomly divided into development and cross-validation groups after stratified by gender. Stepwise model selection was used to generate the model and Bland Altman analysis was used to test agreement. Results: FFM = 2.95 - 3.89 (Gender) + 0.514 (Ht(2)/Z) + 0.090 (Waist) + 0.156 (Body weight). The model fit parameters were an R(2), total F-Ratio, and the SEE of 0.88, 314.3, and 3.3, respectively. None of the published BIA equations met the criteria for agreement. The new BIA equation underestimated FFM by just 0.3 kg in the cross-validation sample. The mean of the difference between FFM by TBW and the new BIA equation were not significantly different; 95% of the differences were between the limits of agreement of -6.3 to 6.9 kg of FFM. There was no significant association between the mean of the differences and their averages (r = 0.008 and p = 0.2). Conclusions: This new BIA equation offers a valid option compared with some of the current published BIA equations to estimate FFM in elderly subjects from five developing countries.
Resumo:
We aim to evaluate intra- and interobserver reproducibility of brachial artery flow-mediated dilation (FMD) and of pulsatility index change (PI-C) 1 min after a 5-min forearm compression in pregnant women. Flow-mediated dilation and PI-C were assessed in 31 healthy pregnant women in 3 consecutive days, by two observers. A broader range of response to the stimulus was observed for PI-C (-58.99%-86.71%) than FMD (2.38%-27.01%). The intraclass correlation coefficients were higher for PI-C than for FMD (intra = 0.90 vs. 0.69, p = 0.047; inter = 0.94 vs. 0.61, p = 0.007). Therefore, PI-C measurements were more reliable than FMD. However, studies comprising of subjects with cardiovascular risk factors relating FMD and PI-C become necessary to validate this method for the study of endothelial dysfunction. (E-mail: wpmartins@gmail.com) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.
Resumo:
The purpose of this study was to evaluate a new periapical index based on cone beam computed tomography (CBCT) for identification of apical periodontitis (AP). The periapical index proposed in this study (CBCTPAI) was developed on the basis of criteria established from measurements corresponding to periapical radiolucency interpreted on CBCT scans. Radiolucent images suggestive of periapical lesions were measured by using the working tools of Planimp software on CBCT scans in 3 dimensions: buccopalatal, mesiodistal, and diagonal. The CBCTPAI was determined by the largest lesion extension. A 6-point (0-5) scoring system was used with 2 additional variables, expansion of cortical bone and destruction of cortical bone. A total of 1014 images (periapical radiographs and CBCT scans) originally taken from 596 patients were evaluated by 3 observers by using the CBCTPAI criteria. AP was identified in 39.5% and 60.9% of cases by radiography and CBCT, respectively (P<.01). The CBCTPAI offers an accurate diagnostic method for use with high-resolution images, which can reduce the incidence of false-negative diagnosis, minimize observer interference, and increase the reliability of epidemiologic studies, especially those referring to AP prevalence and severity. (J Endod 2008;34:1325-1331)
Resumo:
Background: The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. Aim: To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Methods: Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects, Results: The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. Conclusion: These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. (C) 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Objective. Outcome assessment in clinical trials using the Western Ontario and McMaster University (WOMAC 3.0) Osteoarthritis Index is traditionally achieved through self-administration of the Index. However, in other areas of clinical measurement, telephone administration has been shown to be a reliable method of acquiring data that are both accurate and complete. To address this issue in knee osteoarthritis (OA), we conducted a comparative study of telephone administration by interviewer of WOMAC LK3.0 versus onsite self-completion at the hospital. Methods. Fifty consenting patients with knee OA were randomized to complete the WOMAC LK3.0 Index by telephone interview one day, followed by onsite completion the following day, or vice versa. Neither patients nor interviewers had access to any prior scores. Results. The mean age of the 50 patients was 66.3 years (range 44-82); 34 (68%) were female and 16 (32%) male. There was excellent agreement between the mean office and telephone scores, with mean differences for the WOMAC LK3.0 pain, stiffness, and function subscale scores and total score of 0.09, 0.12, 0.78, and 0.98, respectively. These differences were well within the respective protocol defined equivalence criteria of +/- 1.7, +/- 0.9, +/- 6.4, and +/- 9.1, and represented differences from office scores of 0.9, 2.6, 2.4, and 2.2%, respectively. Conclusion. The use of telephone interviews for the WOMAC LK3.0 Index is a valid method of obtaining OA outcome measurements. These observations have important implications for designing data acquisition strategies for future OA clinical trials and for longterm observational studies.
Resumo:
Purpose: This study measured reliability between stroke patients' and significant others' scores on items on the Reintegration to Normal Living (RNL) Index and whether there were any scoring biases. Method The 11-item RNL Index was administered to 57 pairs of patients and significants six months after stroke rehabilitation. The index was scored using a 10-point visual analogue scale. Patient and significant other demographic information and data on patients' clinical, functional and cognitive status were collected. Reliability was measured using the intra-class correlation coefficient (ICC) and percent agreement. Results: Overall poor reliability was found for the RNL Index total score (ICC=.36, 95% CI. 07 to .59) and the daily functioning subscale (ICC=.24, 95% CI -.003 to .46) and moderate reliability was found for the perception of self subscale (ICC=.55, 95 % CI .28 to .73). There was a moderate bias for patients to rate themselves as achieving better reintegration than was indicated by significant others, although no demographic or clinical factors were associated with this bias. Exact match agreement was best for the subjective items and worse for items reflecting mobility around the community and participation in a work activity. Conclusions: Caution is needed when interpreting patient information reported by significant others on the RNL Index. The use of a shorter scale to rate the RNL Index requires investigation.
Resumo:
The conventional methods used to evaluate chitin content in fungi, such as biochemical assessment of glucosamine release after acid hydrolysis or epifluorescence microscopy, are low throughput, laborious, time-consuming, and cannot evaluate a large number of cells. We developed a flow cytometric assay, efficient, and fast, based on Calcofluor White staining to measure chitin content in yeast cells. A staining index was defined, its value was directly related to chitin amount and taking into consideration the different levels of autofluorecence. Twenty-two Candida spp. and four Cryptococcus neoformans clinical isolates with distinct susceptibility profiles to caspofungin were evaluated. Candida albicans clinical isolate SC5314, and isogenic strains with deletions in chitin synthase 3 (chs3Δ/chs3Δ) and genes encoding predicted Glycosyl Phosphatidyl Inositol (GPI)-anchored proteins (pga31Δ/Δ and pga62Δ/Δ), were used as controls. As expected, the wild-type strain displayed a significant higher chitin content (P < 0.001) than chs3Δ/chs3Δ and pga31Δ/Δ especially in the presence of caspofungin. Ca. parapsilosis, Ca. tropicalis, and Ca. albicans showed higher cell wall chitin content. Although no relationship between chitin content and antifungal drug susceptibility phenotype was found, an association was established between the paradoxical growth effect in the presence of high caspofungin concentrations and the chitin content. This novel flow cytometry protocol revealed to be a simple and reliable assay to estimate cell wall chitin content of fungi.