984 resultados para graphite furnace AAS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of domestic cooking on proteins, organic compounds and Fe distribution in beans (Phaseolus vulgaris L.) were investigated. Sequential extraction with different extractant solutions (mixture of methanol and chloroform 1:2 v/v, water, 0.5 mol L-1 NaCl, 70% v/v ethanol and 0.5 mol L-1 NaOH) were used for extracting lipids, albumins, globulins, prolamins and glutelins, respectively. Iron determination by graphite furnace atomic absorption spectrometry (GF AAS), proteins by Bradford method and organic compounds by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) were carried out in this work. High concentration of albumins, globulins and glutelins were found in raw beans, while in the cooked beans, albumins and glutelins are main proteins types. The MALDI-TOF MS spectra of raw and cooked beans revealed that the domestic cooking altered the molecular weight of the organic compounds, since that in the cooked beans were found compounds between 2 and 3.5 kDa, which were not presented in the raw beans. Besides this, in cooked beans were also observed the presence of four compounds of high molecular weight (12-16 kDa), being that in the raw grains there is only one (ca. 15.2 kDa). In raw grains is possible to observe that Fe is mainly associated to albumins, globulins and glutelins. For cooked grains, Fe is associated to albumins and globulins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. The objective of this study was to develop a simple and rapid analytical method for the extraction and pre-concentration based on extraction phenomenon cloud point for the determination of Cd, Pb and Tl in produced water samples by spectrometry of high resolution Absorption source continues and atomization graphite furnace. The Box Behnken design was used to obtain the optimal condition of extraction of analytes. The factors were evaluated: concentration of complexing agent (o,o-dietilditilfosfato ammonium, DDTP), the concentration of hydrochloric acid and concentration of surfactant (Triton X -114). The optimal condition obtained through extraction was: 0,6% m v-1 DDTP, HCl 0,3 mol L-1 and 0,2% m v-1 of Triton X - 114 for Pb; 0,7% m v-1 DDTP, HCl 0,8 mol L-1 and 0,2% m v-1 Triton X-114 for Cd. For Tl was evidenced that best extraction condition occurs with no DDTP, the extraction conditions were HCl 1,0 mol L-1 e 1,0% m v-1 de Triton X - 114. The limits of detection for the proposed method were 0,005 µg L-1 , 0,03 µg L-1 and 0,09 µg L-1 to Cd, Pb and Tl, Respectively. Enrichment factors Were greater than 10 times. The method was applied to the water produced in the Potiguar basin, and addition and recovery tests were performed, and values were between 81% and 120%. The precision was expressed with relative standard deviation (RSD) is less than 5%

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination and monitoring of metallic contaminants in water is a task that must be continuous, leading to the importance of the development, modification and optimization of analytical methodologies capab le of determining the various metal contaminants in natural environments, because, in many cases, the ava ilable instrumentation does not provide enough sensibility for the determination of trace values . In this study, a method of extraction and pre- concentration using a microemulsion system with in the Winsor II equilibrium was tested and optimized for the determination of Co, Cd, P b, Tl, Cu and Ni through the technique of high- resolution atomic absorption spectrometry using a continuum source (HR-CS AAS). The optimization of the temperature program for the graphite furnace (HR-CS AAS GF) was performed through the pyrolysis and atomization curves for the analytes Cd, Pb, Co and Tl with and without the use of different chemical modifiers. Cu and Ni we re analyzed by flame atomization (HR-CS F AAS) after pre-concentr ation, having the sample introduction system optimized for the realization of discrete sampling. Salinity and pH levels were also analyzed as influencing factors in the efficiency of the extraction. As final numbers, 6 g L -1 of Na (as NaCl) and 1% of HNO 3 (v/v) were defined. For the determination of the optimum extraction point, a centroid-simplex statistical plan was a pplied, having chosen as the optimum points of extraction for all of the analytes, the follo wing proportions: 70% aqueous phase, 10% oil phase and 20% co-surfactant/surfactant (C/S = 4). After extraction, the metals were determined and the merit figures obtained for the proposed method were: LOD 0,09, 0,01, 0,06, 0,05, 0,6 and 1,5 μg L -1 for Pb, Cd, Tl, Co, Cu and Ni, re spectively. Line ar ranges of ,1- 2,0 μg L -1 for Pb, 0,01-2,0 μg L -1 for Cd, 1,0 - 20 μg L -1 for Tl, 0,1-5,0 μg L -1 for Co, 2-200 μg L -1 and for Cu e Ni 5-200 μg L -1 were obtained. The enrichment factors obtained ranged between 6 and 19. Recovery testing with the certified sample show ed recovery values (n = 3, certified values) after extraction of 105 and 101, 100 and 104% for Pb, Cd, Cu and Ni respectively. Samples of sweet waters of lake Jiqui, saline water from Potengi river and water produced from the oil industry (PETROBRAS) were spiked and the recovery (n = 3) for the analytes were between 80 and 112% confirming th at the proposed method can be used in the extraction. The proposed method enabled the sepa ration of metals from complex matrices, and with good pre-concentration factor, consistent with the MPV (allowed limits) compared to CONAMA Resolution No. 357/2005 which regulat es the quality of fresh surface water, brackish and saline water in Brazil.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An approach was developed to estimate molecular weight distribution of water-soluble Cu, Fe, Mn and Zn species in Brazil nut, cupuassu seed and coconut pulp by size exclusion chromatography (SEC) coupled on-line to ultra-violet (UV) and off-line to graphite furnace atomic absorption spectrometry (GF-AAS) detectors and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS). SEC-UV analytical signals showed the prevalence of high molecular weight (HMW) species (79-1.7 kDa for Brazil nut, 50-1.7 kDa for coconut pulp, and 34-1.7 kDa for cupuassu seeds). The Brazil nut SEC-UV, GF-AAS and MALDI-TOF mass spectra gave confirmation of the association of the elements with water-soluble compounds. The elemental profiles were associated with fractions of compounds of molecular weight 1.2-16 kDa for Brazil nut, 1.7-13 kDa for coconut pulp, and 1.2-7.6 kDa for cupuassu seeds. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work describes the evaluation of several parameters for the preparation of a tuna fish candidate as a reference material (RM) in order to measure the total As mass fraction by slurry sampling graphite furnace atomic absorption spectrometry (SLS-GF AAS) and slurry sampling hydride generation atomic absorption spectrometry (SLS-HG AAS). The main parameters investigated were the homogeneity, analyte segregation and composition during material production. For candidate RM preparation, tuna fish was collected at a local market, cleaned, freeze-dried and treated using different procedures as follows: (1) ground in a cutting mill and separated in different particle sizes (2) ground in cryogenic mill. The mass fraction of As in the cryogenically ground sample was (4.77 +/- A 0.19) mu g g(-1) for SLS-GF AAS and (4.61 +/- A 0.34) mu g g(-1) for SLS-HG AAS. The accuracy of the procedures was checked with tuna fish certified reference material (BCR 627) with recoveries of 102 and 94% for SLS-GF AAS and SLS-HG AAS, respectively. The homogeneity factor was calculated for different pretreatment procedures and for particle sizes in the range of 500-150 mu g, indicating good homogeneity, except for raw fish. There was no observed analyte segregation and no losses, no contamination and no changes in the microdistribution of material during preparation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method has been developed for the direct determination of As in sugar by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer (end-capped THGA) and longitudinal Zeeman-effect background correction. The thermal behavior of As during the pyrolysis and atomization steps was investigated in sugar solutions containing 0.2% (v/v) HNO3 using Pd, Ni, and a mixture of Pd + Mg as the chemical modifiers. For a 60-muL sugar solution, an aliquot of 8% (m/v) in 0.2% (v/v)HNO3 was dispensed into a pre-heated graphite tube at 70 degreesC. Linear analytical curves were obtained in the 0.25 - 1.50-mug L-1 As range. Using 5 mug Pd and a first pyrolysis step at 600 degreesC assisted by air during 40 s, the formation of a large amount of carbonaceous residue inside the atomizer was avoided. The characteristic mass was calculated as 24 pg As and the lifetime of the graphite tube was around 280 firings. The limit of detection (L.O.D.) based on integrated absorbance was 0.08 mug L-1 (4.8 pg As) and the typical relative standard deviation (n = 12) was 7% for a sugar solution containing 0.5 mug L-1. Recoveries of As added to sugar samples varied from 86 to 98%. The accuracy was checked in the direct analysis of eight sugar samples. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained for acid-digested sugar samples by GFAAS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method has been developed for the direct simultaneous determination of Cd and Pb in white and red wine by electrothermal atomic absorption spectrometry (ET-AAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of both analytes during pyrolysis and atomization stages were investigated in 0.028 mol l(-1) HNO3 and in 1 + 1 v/v diluted wine using mixtures of Pd(NO3)(2) + Mg(NO3)(2) and NH4H2PO4 + Mg(NO3)(2) as chemical modifiers. With 5 mug Pd + 3 mug Mg as the modifiers and a two-step pyrolysis (10 s at 400 degreesC and 10 s at 600 degreesC), the formation of carbonaceous residues inside the atomizer was avoided. For 20 mul of sample (wine + 0.056 mol l(-1) HNO3, 1 + 1, v/v) dispensed into the graphite tube, analytical curves in the 0.10-1.0 mug l(-1) Cd and 5.0-50 mug l(-1) Pb ranges were established. The characteristic mass was approximately 0.6 pg for Cd and 33 pg for Pb, and the lifetime of the tube was approximately 400 firings. The limits of detection (LOD) based on integrated absorbance (0.03 mug l(-1) for Cd, 0.8 mug l(-1) for Pb) exceeded the requirements of Brazilian Food Regulations (decree #55871 from Health Department), which establish the maximum permissible level for Cd at 200 mug l(-1) and for Pb at 500 mug l(-1). The relative standard deviations (n = 12) were typically < 8% for Cd and < 6% for Pb. The recoveries of Cd and Pb added to wine samples varied from 88 to 107% and 93 to 103%, respectively. The accuracy of the direct determination of Cd and Ph was checked for 10 table wines by comparing the results with those obtained for digested wine using single-element ET-AAS, which were in agreement at the 95% confidence level. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The development of an electroanalytical method for simultaneous determination of copper and lead ions in sugar cane spirit (cachaça) using carbon paste electrode modified with ascorbic acid and carbon nanotubes (CPE-AaCNT) is described. Squarewave voltammetry (SWV) with anodic stripping was employed, and this technique was optimized with respect to the following parameters: frequency (50 Hz), amplitude (100 mV) and scan increment (9 mV). The analytical curves were linear in the range from 0.0900 to 7.00 mg L - 1 for lead and copper. The limits of detection were 48.5 and 23.9 µg L - 1 for lead and copper, respectively. The developed method was applied to the simultaneous determination of copper and lead in five commercial samples of sugar cane spirit. The results were in good agreement with those obtained by F AAS/GF AAS (flame atomic absorption spectrometry/graphite furnace atomic absorption spectrometry) and showed that CPE-AaCNT can be successfully employed in the simultaneous determination of these metals in real sugar cane spirit samples.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Evidências experimentais sugerem que o alumínio é um agente neurotóxico com ações deletérias sobre os processos cognitivos. Neste estudo, investigou-se os efeitos comportamentais, histopatológicos e bioquímicos da intoxicação crônica com citrato de alumínio sobre o hipocampo de ratos adultos, e ao mesmo tempo aplicou-se uma terapia experimental de tratamento com magnésio para a reversão das alterações neuropatológicas encontradas. Utilizou-se 70 ratos Wistar machos de 200-250 g, divididos em grupos da seguinte maneira: controle, citrato de sódio (CNa), citrato de alumínio (CAl), citrato de alumínio + sulfato de magnésio (CAl+Mg), citrato de sódio + sulfato de magnésio (CNa+Mg). A dose usada de citrato de alumínio foi de 100 mg/kg e sulfato de magnésio 250 mg/kg durante 30 dias. Os animais foram submetidos aos testes comportamentais do campo aberto, Rota rod, Reconhecimento social e Labirinto em T elevado (LTE), análise bioquímica, histopatológica e imunoistoquímica para GFAP. Além disso, foram verificados os níveis de alumínio no plasma e no hipocampo dos animais em espectrômetro de absorção atômica em forno de grafite (GF AAS). Os resultados obtidos mostraram que o grupo CAl apresentou um aumento da atividade locomotora no teste do campo aberto em comparação ao grupo controle e já o grupo CAl+Mg apresentou uma diminuição (P<0.001). Nos testes de memória do LTE e de Reconhecimento social, os animais do grupo CAl apresentaram déficits no cognitivos em relação aos demais grupos enquanto os animais do grupo CAl+Mg apresentaram um bom desempenho nos teste (P<0.001). Os níveis de alumínio encontrados no hipocampo do grupo CAl foram consideravelmente elevados e nos demais grupos os níveis ficaram abaixo do limite de detecção. Na análise histopatológica e imunoistoquímica, os animais do grupo CAl apresentaram diminuição da densidade celular e reatividade astrocitária nas camadas CA1, CA3 e hilo do hipocampo. Estes resultados sugerem que a intoxicação experimental com citrato de alumínio induz déficits de aprendizado e memória e que a administração de sulfato de magnésio pode ter a capacidade de minimizar os danos causados pelo metal no hipocampo de animais intoxicados.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Neste estudo, cromatografia de exclusão por tamanho (SEC) com detecção por UV e detecção off-line por espectrometria de absorção atômica em forno de grafite (GF AAS) foi usada para investigar a associação de cobre a espécies de alta massa molecular (HMW) e baixa massa molecular (LMW) presentes na polpa de açaí (Euterpe oleracea Mart.). A concentração total de cobre obtida nos digeridos da polpa de açaí foi 10,5 µg g-1. Cobre foi encontrado associado às frações de HMW e LMW, correspondentes às massas moleculares de 28,7, 2,6 e 0,43 kDa.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Neste estudo, a cromatografia por exclusão de tamanho (SEC) com detecção online ultravioleta (UV), espectrometria de absorção atômica em forno de grafite (GF AAS) e a espectrometria de massa por tempo de voo com dessorção/ionização de matriz assistida por laser (MALDI-TOF-MS) foram usadas para estudar a associação de selênio com macromoléculas e compostos presentes no soro de leite de búfala e bovino. Os perfis de SEC-UV obtidos para as amostras de soro de leite de búfala e soro de leite bovino indicaram a presença de espécies de alta e baixa massa molecular. A combinação das informações obtidas com SEC-UV, GF AAS e MALDI-TOF-MS para as frações < 10 kDa confirmou a associação de selênio com espécies de baixa massa molecular.