989 resultados para fixed path methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Development and standardization of reliable methods for detection of Mycobacterium tuberculosis in clinical samples is an important goal in laboratories throughout the world. In this work, lung and spleen fragments from a patient who died with the diagnosis of miliary tuberculosis were used to evaluate the influence of the type of fixative as well as the fixation and paraffin inclusion protocols on PCR performance in paraffin embedded specimens. Tissue fragments were fixed for four h to 48 h, using either 10% non-buffered or 10% buffered formalin, and embedded in pure paraffin or paraffin mixed with bee wax. Specimens were submitted to PCR for amplification of the human beta-actin gene and separately for amplification of the insertion sequence IS6110, specific from the M. tuberculosis complex. Amplification of the beta-actin gene was positive in all samples. No amplicons were generated by PCR-IS6110 when lung tissue fragments were fixed using 10% non-buffered formalin and were embedded in paraffin containing bee wax. In conclusion, combined inhibitory factors interfere in the detection of M. tuberculosis in stored material. It is important to control these inhibitory factors in order to implement molecular diagnosis in pathology laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trichomonas vaginalis is the etiologic agent of trichomoniasis, the most common non-viral sexually transmitted disease (STD) in the world. The diagnosis is based on wet mount preparation and direct microscopy on fixed and stained clinical specimens. The aim of this study was to compare the performance of different fixing and staining techniques used in the detection of T. vaginalis in urine. The smears were fixed and submitted to different methods of permanent staining and then, the morphological aspects of the parasites were analyzed and compared. The Papanicolaou staining with ethanol as the fixative solution showed to be the best method of permanent staining. Our data suggest that staining techniques in association with wet mount examination of fresh specimens contribute to increase the sensitivity in the diagnosis of trichomoniasis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The present study was designed to assess the occurrence of co-infection or cross-reaction in the serological techniques used for detecting the anti-Leishmania spp., -Babesia canis vogeli and -Ehrlichia canis antibodies in urban dogs from an area endemic to these parasites. METHODS: The serum samples from dogs were tested for the Babesia canis vogeli strain Belo Horizonte antigen and Ehrlichia canis strain São Paulo by immunofluorescence antibody test (IFAT) and by anti-Leishmania immunoglobulin G (IgG) antibody detection to assess Leishmania infection. We used the following four commercial kits for canine visceral leishmaniasis: ELISA, IFAT, Dual Path Platform (DPP) (Bio Manguinhos(r)/FIOCRUZ/MS) and a rK39 RDT (Kalazar Detect Canine Rapid Test; Inbios). RESULTS : Of 96 serum samples submitted to serological assays, 4 (4.2%) were positive for Leishmania as determined by ELISA; 12 (12.5%), by IFAT; 14 (14.6%) by rK39 RDT; and 20 (20.8%), by DPP. Antibodies against Ehrlichia and Babesia were detected in 23/96 (23.9%) and 30/96 (31.2%) samples, respectively. No significant association was identified between the results of tests for detecting Babesia or Ehrlichia and those for detecting Leishmania (p-value>0.05). CONCLUSIONS: In the present study, we demonstrated co-infection with Ehrlichia or Babesia and Leishmania in dogs from Minas Gerais (Brazil); we also found that the serological tests that were used did not cross-react.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Shifting from chemical to biotechnological processes is one of the cornerstones of 21st century industry. The production of a great range of chemicals via biotechnological means is a key challenge on the way toward a bio-based economy. However, this shift is occurring at a pace slower than initially expected. The development of efficient cell factories that allow for competitive production yields is of paramount importance for this leap to happen. Constraint-based models of metabolism, together with in silico strain design algorithms, promise to reveal insights into the best genetic design strategies, a step further toward achieving that goal. In this work, a thorough analysis of the main in silico constraint-based strain design strategies and algorithms is presented, their application in real-world case studies is analyzed, and a path for the future is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess, in myocardium specimens obtained from necropsies, the correlation between the concentration of hydroxyproline, measured with the photocolorimetric method, and the intensity of fibrosis, determined with the morphometric method. METHODS: Left ventricle myocardium samples were obtained from 45 patients who had undergone necropsy, some of them with a variety of cardiopathies and others without any heart disease. The concentrations of hydroxyproline were determined with the photocolorimetric method. In the histologic sections from each heart, the myocardial fibrosis was quantified by using a light microscope with an integrating ocular lens. RESULTS: A median of, respectively, 4.5 and 4.3 mug of hydroxyproline/mg of dry weight was found in fixed and nonfixed left ventricle myocardium fragments. A positive correlation occurred between the hydroxyproline concentrations and the intensity of fibrosis, both in the fixed (Sr=+0.25; p=0.099) and in the nonfixed (Sr=+0.32; p=0.03) specimens. CONCLUSION: The biochemical methodology was proven to be adequate, and manual morphometry was shown to have limitations that may interfere with the statistical significance of correlations for the estimate of fibrosis intensity in the human myocardium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrokinetic transport, electrochromatography, electroosmotic flow, electrophoresis, concentration polarization, fixed beds, monoliths, dynamic NMR microscopy, quantitative confocal laser scanning microscopy, mathematical modelling, numerical analysis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the estuary of the Mamanguape River (Paraíba, Brazil), a new collection technique was developed and applied with virgin poles of mangrove trees Avicennia schaueriana (Verbenaceae), Rhizophora mangle (Rhizophoraceae), and Laguncularia racemosa (Combretaceae), taking into account wood preference, water salinity and depth influence during teredinid larval settlement. Sets of poles were vertically fixed in the riverbed at three sites along a decreasing salinity gradient, where they stayed for four months. The poles were collected and divided into upper, median, and lower segments, in agreement with different immersion regimes. An increase of 239% was obtained in the number of individuals when compared to a previous study in the same area using a different methodology. The species Teredo bartschi (Clapp, 1923), Nausitora fusticula (Jeffreys, 1860) and Bankia fimbriatula Moll & Roch, 1931 were registered in both studies, and the species Psiloteredo healdi (Bartsch, 1931) is here registered for the first time as occurring in that estuary. The species Neoteredo reynei (Bartsch, 1920), previously registered on tree branches of the mangrove habitat, was not found in the present work. Bankia fimbriatula, the most abundant species, did not show preference for any substratum but occurred significantly on the lower segment of the poles. N. fusticula, second in abundance, preferred to settle on poles of A. schaueriana and on any of the three segments. Aiming to assess the habitat variations, a more accurate study on teredinids diversity in mangrove ecosystems should be performed through a concomitant analysis from tree branches of the mangrove habitat, as well as from poles of mangrove trees or panels made of pine wood or mangrove trees wood. These collection devices should be maintained along a decreasing salinity gradient exposed to different tide levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Aims: Two distinct e ndoscopic phenotypes of E osinophilic Esophagitis (EoE) h ave been identified: t he inflammatory (IP) a nd the stenosing (SP) p henotype. I t is not known whether these EoE-associated phenotypes are reflective of different phases during disease course. We aimed to assess the phenotype a t initial EoE p resentation and d iagnosis and to evaluate if SP increases over time. Methods: R etrospective a nalysis of t he Swiss EoE Database (SEED) extended b y a review of p atients charts, endoscopy and pathology records. Results: F orty-four E oE p atients were a nalyzed (33 males, mean age at index visit 41 ± 14 years, all Caucasians). Median follow-up t ime was 3.1 years (IQR 1-4, r ange 1 -18 years). Median diagnostic delay w as 5 y ears (IQR 2-16, range 0-34 years). A t first diagnosis, 3 2% ( 14/44) o f EoE patients h ad already presented w ith a stenosis. T he mean d iameter o f the stenoses w as 1 0 ± 2 mm, and the mean length was 2 .8 ± 2 .9 cm. Peak e osinophil count d id n ot c hange over t ime (48 ± 39 eos/HPF at index visit vs. 59 ± 41 eos/HPF at end of follow-up, n=44). The risk of the presence of a stenosis at index visit was 0% f or a d isease duration of 0 -4 y ears, 37% f or a d isease duration between 5-10 years and 67% f or a d isease duration >10 years (p = 0.0035, trend test). Conclusions: T he frequency of e sophageal stenoses i s proportional to the disease duration, whereas the inflammatory activity does n ot s ignificantly c hange over t ime. O ur f indings underscore the necessity to reduce diagnostic delay in EoE and to control the underlying inflammatory processes to prevent esophageal remodeling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, different recovery methods applied at different network layers and time scales are used in order to enhance the network reliability. Each layer deploys its own fault management methods. However, current recovery methods are applied to only a specific layer. New protection schemes, based on the proposed partial disjoint path algorithm, are defined in order to avoid protection duplications in a multi-layer scenario. The new protection schemes also encompass shared segment backup computation and shared risk link group identification. A complete set of experiments proves the efficiency of the proposed methods in relation with previous ones, in terms of resources used to protect the network, the failure recovery time and the request rejection ratio

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Cadaveric study at our institution has demonstrated that optimal basaplate fixation of a reversed shoulder arthroplasty (RSA) could be achieved with screws in three major columns. Our aim was to review our early rate of aseptic glenoid loosening in a series of baseplate fixed according to this principle. Material and Methods Between 2005 and 2008, 48 RSA (Aequalis Reversed) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixation were done using a nonlocking posterior screw in the spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. The number of screws were reported. We measured the position of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally we reported glenoid aseptic loosening which was defined as implant subsidence. Results Four patients were lost to follow-up. Thus, 44 shoulders could be reviewed after a mean follow-up of 13 months (range, 6 to 32 months). All baseplates were fixed with 4 screws. Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out the target. Two (4.5%) patients had glenoid loosening. Both had a scapular spine and a coracoid screw partially in the bone. Conclusion Early aseptic glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient bone stock and bone quality. Our study demonstrate that baseplate fixation according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Floor cleaning is a typical robot application. There are several mobile robots aviable in the market for domestic applications most of them with random path-planning algorithms. In this paper we study the cleaning coverage performances of a random path-planning mobile robot and propose an optimized control algorithm, some methods to estimate the are of the room, the evolution of the cleaning and the time needed for complete coverage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.