972 resultados para endotracheal tube cuff pressure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: During general anesthesia, nitrous oxide (N2O) diffuses rapidly into the air-filled laryngeal mask airway (LMA) cuff, increasing intracuff pressure. There is no clear correlation between LMA intracuff pressure and pressure on the pharynx. We have studied the effects of high LMA intracuff pressures secondary to N2O on the pharyngeal mucosa of dogs.Methods: Sixteen mongrel dogs were randomly allocated to two groups: G1 (intracuff volume, 30 mL; n = 8) breathed a mixture of O-2 (1 L.min(-1)) and air (1 L.min(-1)) and G2 (intracuff volume, 30 mL; n=8) a mixture of O-2 (1 L.min(-1)) and N2O (1 L.min(-1)). Anesthesia was induced and maintained with pentobarbitone. LMA cuff pressure was measured at zero (control), 30, 60, 90 and 120 min after #4 LMA insertion. The dogs were sacrificed, and biopsy specimens from seven predetermined areas of the pharynx in contact with the LMA cuff were collected for light (LM) and scanning electron microscopic (SEM) examination by a blinded observer.Results: LMA intracuff pressure decreased with time in G1 (P < 0.001) and increased in G2 (P < 0.001). There was a significant difference between the groups (P < 0.001). In both groups, the LM study showed a normal epithelium covering the pharyngeal mucosa and mild congestion in the subepithelial layer There were no differences between the groups (P > 0.10) or among the areas sampled (P > 0.05). In both groups, the SEM study showed a normal pharyngeal mucosa with mild superficial desquamation. Few specimens in G1 and G2 showed more intense epithelial desquamation.Conclusion: High LMA intracuff pressures produced by N2O do not increase pharyngeal mucosal injury in dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A intubação traqueal associada a operações das vias aéreas faz com que complicações como laringoespasmo, broncoespasmo e períodos de redução da saturação de oxigênio sejam frequentemente relatados em adenotonsilectomias, procedimento que, por sua natureza, eleva a incidência de tais complicações. O objetivo deste estudo foi analisar a ocorrência de problemas respiratórios comparando-se o uso da máscara laríngea (ML) descartável com a intubação orotraqueal em adenotonsilectomias. MÉTODOS: Foram avaliados 204 pacientes pediátricos submetidos a anestesia geral para adenotonsilectomias e alocados em dois grupos, aleatoriamente: grupo Cânula Traqueal (CT, n = 100) e grupo Máscara Laríngea (ML, n = 104). Foram observados os níveis de saturação de pulso de oxigênio (SpO2) após a indução anestésica (SpO2-1), após o estabelecimento de campo operatório (SpO2-2), ao término do procedimento cirúrgico (SpO2-3), três minutos após a retirada do dispositivo respiratório (SpO2-4) e na admissão da sala de recuperação anestésica (SpO2-5). As complicações respiratórias foram relatadas. RESULTADOS: Os valores médios e os desvios padrão de SpO2 nos grupos CT e ML foram, respectivamente: SpO2-1: 98,9 ± 1,0 e 98,7 ± 0,8 (p > 0,25); SpO2-2: 97,4 ± 1,0 e 94,9 ± 4,3 (p < 0,001); SpO2-3: 96,9 ± 1,1 e 97,2 ± 1,1 (p = 0,037); SpO2-4: 91,7 ± 9,0 e 95,2 ± 2,2 (p < 0,001); SpO2-5: 94,0 ± 2,1 e 95,8 ± 2,6 (p < 0,001). No grupo ML, em 12 pacientes, foi necessária alguma manobra para ajuste do dispositivo e correção de vazamento durante o ato operatório. A ML foi substituída pela CT em quatro pacientes. As complicações respiratórias foram similares entre os grupos. CONCLUSÕES: Adenotonsilectomias em pacientes pediátricos com o emprego da ML, em comparação com a CT, resulta em menores valores de SpO2 intraoperatórios e, eventualmente, necessidade de substituição da ML pela CT. Apesar de a ML viabilizar a cirurgia, pela segurança, o uso da CT é preferível.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The long-term administration of nitric oxide synthesis inhibitors induces arterial hypertension accompanied by left ventricular hypertrophy and myocardial ischemic lesions. Because the enhancement of sympathetic drive has been implicated in these phenomena, the current study was performed to determine the potency of β-adrenoceptor agonists and muscarinic agonists on the spontaneous rate of isolated right atria from rats given long-term treatment with the nitric oxide inhibitor N(ω)-nitro-L-arginine methyl ester (L-NAME). Atrial lesions induced by long-term treatment with L-NAME were also evaluated. Long-term L-NAME treatment caused a time-dependent, significant (P<0.05) increase in tail-cuff pressure compared with control animals. Our results showed that the potency of isoproterenol, norepinephrine, carbachol, and pilocarpine in isolated right atria from rats given long-term treatment with L-NAME for 7, 15, 30, and 60 days was not affected as compared with control animals. Addition of L-NAME in vitro (100 μmol/L) affected neither basal rate nor chronotropic response for isoproterenol and norepinephrine in rat heart. Stereological analysis of the right atria at 15 and 30 days revealed a significant increase on amount of fibrous tissues in L-NAME- treated groups (27±2.3% and 28±1.3% for 15 and 30 days, respectively; P<0.05) as compared with the control group (22±1.1%). Our results indicate that nitric oxide does not to interfere with β-adrenoceptor-mediated and muscarinic receptor-mediated chronotropic responses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work analyzes an active fuzzy logic control system in a Rijke type pulse combustor. During the system development, a study of the existing types of control for pulse combustion was carried out and a simulation model was implemented to be used with the package Matlab and Simulink. Blocks which were not available in the simulator library were developed. A fuzzy controller was developed and its membership functions and inference rules were established. The obtained simulation showed that fuzzy logic is viable in the control of combustion instabilities. The obtained results indicated that the control system responded to pulses in an efficient and desirable way. It was verified that the system needed approximately 0.2 s to increase the tube internal pressure from 30 to 90 mbar, with an assumed total delay of 2 ms. The effects of delay variation were studied. Convergence was always obtained and general performance was not affected by the delay. The controller sends a pressure signal in phase with the Rijke tube internal pressure signal, through the speakers, when an increase the oscillations pressure amplitude is desired. On the other hand, when a decrease of the tube internal pressure amplitude is desired, the controller sends a signal 180° out of phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The laryngeal mask has been frequently used in Anesthesiology. Although the rate of complications with this technique is smaller than that of the endotracheal tube, it is not devoid of risks, especially in cases of difficult airways. The objective of this study was to report a case of unilateral lingual nerve damage after the use of the laryngeal mask airway. CASE REPORT: A female patient underwent a surgical procedure for removal of bilateral breast prosthesis under general, balanced anesthesia, with a size three laryngeal mask. The balloon was inflated with 30 mL of air. After the first postoperative hour, she developed decreased sensation and pain in the oropharynx and posterior two thirds of the tongue, which evolved for loss of taste in the next 24 hours. A tentative diagnosis of lingual nerve neuropraxis secondary to the use of the laryngeal mask was made. After three weeks, her symptoms subsided. CONCLUSION: Although complications after the use of the laryngeal mask airway are rare, they do occur, and neuropraxis of the lingual nerve is one of them. The diagnosis is clinical and it has a good outcome, with resolution of the symptoms within a few weeks or months. © Sociedade Brasileira de Anestesiologia, 2007.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a computational fluid dynamics (CFD) application about the axial fan design used in an agricultural spraying system with a theoretical and experimental analysis of comparative results between the characteristic curves of a fan for several rotations and numerical results for the influence of blade attack angle variation and optimization of the spraying system, both for a same rotation. Flow was considered three-dimensional, turbulent, isothermal, viscous and non-compressible in a steady state, disregarding any influence of the gravity field. The average turbulent field was obtained from the application of time average where the turbulence model required for closing the set of equations was the k-E model. Resolution of all connected phenomena was achieved with the help of a fluid dynamics computer, CFX, which uses the finite volumes technique as a numerical method. In order to validate the theoretical analysis, an experiment was conducted in a circular section of a horizontal wind tunnel, using a Pitot tube for pressure readings. The main results demonstrate that the methodology used, based on CFD techniques, is able to reproduce the phenomenological behavior of an axial fan in a spraying system because results were very reliable and similar to experimentally measured ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Chyle fistulas may occur after left neck dissections that include level IV, due to injury of the thoracic duct or of 1 of its major branches. Despite being unusual, this complication carries substantial postoperative morbidity and even mortality. So far, no effective intraoperative maneuver has been reported to detect this fistula at the end of a neck dissection. In this cohort study, we sought to describe a simple new maneuver, intraoperative abdominal compression, which can effectively help to identify an open major lymphatic duct on level IV at the end of a neck dissection. Patients and Methods From March 1989 to September 2010, 206 patients underwent neck dissections involving left level IV, and underwent intraoperative abdominal compression. There were 119 men and 87 women, with ages ranging from 18 to 81 years (median, 52 years). One hundred forty-four patients had squamous cell carcinomas, 54 had thyroid carcinomas, 5 had malignant melanomas, and 3 had salivary cancers. Distribution by type of left neck dissection was: selective including levels II, III, and IV (73 cases; 35.4%), selective including levels II, III, IV, and V (55 cases; 26.6%), selective including levels I, II, III, and IV (12 cases; 5.8%), modified radical (47 cases; 22.8%), and radical (19 cases; 9.2%). In all cases, at the end of the procedure, the endotracheal tube was temporarily disconnected from the ventilator. Keeping the dissected level IV area under clear visualization, an abdominal compression was performed. At this moment, any detected lymphatic leak was carefully clamped and tied with nonabsorbable sutures. After ventilating the patient, the intraoperative abdominal compression was repeated to reassure complete occlusion of the lymphatic vessel. Results In 13 cases (6.3%), a chyle leak was detected after performing the intraoperative abdominal compression. All leaks except for 2 were successfully controlled after 1 attempt. In these 2 patients, a patch of muscle and fat tissue was applied with fibrin glue on the top. In 1 of these patients, another chyle leak in a different location was detected only at the second intraoperative abdominal compression, and was also effectively closed. Postoperatively, there were 2 (1%) chyle fistulas, both among these 13 cases, and all were successfully managed with clinical measures only. No fistulas occurred among the remaining 193 patients in whom intraoperative abdominal compression did not demonstrate lymphatic leak. Conclusion To our knowledge, this is the first description of a specific maneuver to actively detect a lymphatic fistula at the end of a left neck dissection involving level IV. In this study, intraoperative abdominal compression was able to detect an open lymphatic vessel in 6.3% of the cases, as well as to assure its effective sealing in the remaining 93.7% of the patients. Moreover, no life-threatening high-volume fistula was noted in this study. (C) 2012 Wiley Periodicals, Inc. Head Neck, 2012

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: Angiotensin-converting enzyme (ACE) inhibitors are used in diabetic kidney disease to reduce systemic/intra-glomerular pressure. The objective of this study was to investigate whether reducing blood pressure (BP) could modulate renal glucose transporter expression, and urinary markers of diabetic nephropathy in diabetic hypertensive rats treated with ramipril or amlodipine. Main methods: Diabetes was induced in spontaneously-hypertensive rats (~210 g) by streptozotocin (50 mg/kg). Thirty days later, animals received ramipril 15 μg/kg/day (R, n =10), or amlodipine 10 mg/kg/day (A, n= 8,) or water (C, n = 10) by gavage. After 30-day treatment, body weight, glycaemia, urinary albumin and TGF-β1 (enzyme-linked immunosorbent assay) and BP (tail-cuff pressure method) were evaluated. Kidneys were removed for evaluation of renal cortex glucose transporters (Western blotting) and renal tissue ACE activity (fluorometric assay). Key findings: After treatments, body weight (p = 0.77) and glycaemia (p = 0.22) were similar among the groups. Systolic BP was similarly reduced (p < 0.001) in A and R vs. C (172.4 ± 3.2; 186.7 ± 3.7 and 202.2 ± 4.3 mm Hg; respectively). ACE activity (C: 0.903 ± 0.086; A: 0.654 ± 0.025, and R: 0.389 ± 0.057 mU/mg), albuminuria (C: 264.8 ± 15.4; A: 140.8 ± 13.5 and R: 102.8 ± 6.7 mg/24 h), and renal cortex GLUT1 content (C: 46.81 ± 4.54; A: 40.30 ± 5.39 and R: 26.89 ± 0.79 AU) decreased only in R (p < 0.001, p < 0.05 and p < 0.001; respectively). Significance:We concluded that the blockade of the renin–angiotensin systemwith ramipril reduced earlymarkers of diabetic nephropathy, a phenomenon that cannot be specifically related to decreased BP levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Nebulized surfactant therapy has been proposed as an alternative method of surfactant administration. The use of a perforated vibrating membrane nebulizer provides a variety of advantages over conventional nebulizers. We investigated the molecular structure and integrity of poractant alfa pre- and post-nebulization. METHOD Curosurf® was nebulized using an Investigational eFlow® Nebulizer System. Non-nebulized surfactant ("NN"), recollected surfactant droplets from nebulization through an endotracheal tube ("NT") and nebulization of surfactant directly onto a surface ("ND") were investigated by transmission electron microscopy. Biophysical characteristics were assessed by the Langmuir-Wilhelmy balance and the Captive Bubble Surfactometer. RESULTS Volume densities of lamellar body-like forms (LBL) and multi-lamellar forms (ML) were high for "NN" and "NT" samples (38.8% vs. 47.7% for LBL and 58.2% vs. 47.8% for ML). In the "ND" sample, we found virtually no LBL's, ML's (72.6%) as well as uni-lamellar forms (16.4%) and a new structure, the "garland-like" forms (9.4%). Surface tension for "NN" and "NT" was 23.33 ± 0.29 and 25.77 ± 1.12 mN/m, respectively. Dynamic compression-expansion cycling minimum surface tensions were between 0.91 and 1.77 mN/m. CONCLUSION The similarity of surfactant characteristics of nebulized surfactant via a tube and the non-nebulized surfactant suggests that vibrating membrane nebulizers are suitable for surfactant nebulization. Alterations in surfactant morphology and characteristics after nebulization were transient. A new structural subtype of surfactant was identified. Pediatr Pulmonol. 2014; 49:348-356. © 2013 Wiley Periodicals, Inc.