965 resultados para drug urine level
Resumo:
An adsorptive stripping voltammetric procedure for the determination of the antidepressant venlafaxine in urine using a mercury film microelectrode wasdeveloped. The method is based on controlled adsorptive accumulation of the drug at the potential of 1.00V (vs. Ag/AgCl) in the presence of 1.25 x10 -2 molL- 1 borate buffer (pH 8.7). Urine samples were analyzed directly after performing a ten-fold dilution with the supporting electrolyte but without other pretreatment. The limit of detection obtained for a 30 s collection time was 0.693x 10- 6 mol L -1. Recovery experimentsgave good results at the 10 -6 mol L- 1 level (bias less 5% were obtained).
Resumo:
Clenbuterol is a β2 agonist agent with anabolic properties given by the increase in the muscular mass in parallel to the decrease of the body fat. For this reason, the use of clenbuterol is forbidden by the World Anti-Doping Agency (WADA) in the practice of sport. This compound is of particular interest for anti-doping authorities and WADA-accredited laboratories due to the recent reporting of risk of unintentional doping following the eating of meat contaminated with traces of clenbuterol in some countries. In this work, the development and the validation of an ultra-high pressure liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the quantification of clenbuterol in human urine is described. The analyte was extracted from urine samples by liquid-liquid extraction (LLE) in basic conditions using tert butyl-methyl ether (TBME) and analyzed by UHPLC-MS/MS with a linear gradient of acetonitrile in 9min only. The simple and rapid method presented here was validated in compliance with authority guidelines and showed a limit of quantification at 5pg/mL and a linearity range from 5pg/mL to 300pg/mL. Good trueness (85.8-105%), repeatability (5.7-10.6% RSD) and intermediate precision (5.9-14.9% RSD) results were obtained. The method was then applied to real samples from eighteen volunteers collecting urines after single oral doses administration (1, 5 and 10μg) of clenbuterol-enriched yogurts.
Resumo:
Resumen tomado de la publicaci??n
Resumo:
The present study is aimed to determine serum and urine interleukin-8 (IL-8) levels in premature infants with late onset sepsis (LOS) and to evaluate if urine IL-8 is a useful test for LOS diagnosis. Fifty-six premature infants admitted to the NICU over 1 year had serum and urine IL-8 determined by ELISA. They were divided into three groups: I definite sepsis, II probable sepsis and III non-infected. Results were expressed as mean or median. Differences between groups were assessed by ANOVA, Kruskal-Wallis ANOVA and Dunns Method. Sensitivity, specificity and positive and negative predictive values were calculated and a receiver operator characteristic curve was constructed to determine serum and urine IL-8 accuracy. There were no differences between groups for birth weight, and gestational and post-natal age. Median serum and urine IL-8 levels were significantly higher in GI and GII: 929 x 906 x 625pg/ml; P=0.024, and 249 x 189 x 42pg/mgCr; P< 0.001. Optimal cut-off point was 625pg/ml for serum IL-8 with 69 sensitivity and 75pg/mgCr for urine IL-8 with 92 sensitivity. IL-8 can be determined in urine from premature infants with LOS and is an accurate and feasible diagnosis method.
Resumo:
The differential pulse polarographic behaviour of cinnamic acid was studied in acetate and phosphate buffer solutions (pH 3.5-7.5). The reduction mechanism is discussed. The drug can be determined at pH 5.0 over the concentration range 5 X 10(-5)-1 X 10(-3) mol l(-1). The effect of tetraalkylammonium salts on the electroanalytical determination of cinnamic acid was investigated, the direct determination of the drug (0.7-5.5 mu g ml(-1)) in urine samples diluted with acetate buffer (pH 5.0) can be effected in the presence of 1 x 10(-3) mol l(-1) cetyldimethylethylammonium bromide solution. The detection limit was found to be 0.1 mu g ml(-1). The relative standard deviation from six determinations at the 5.5 mu g ml(-1) level was 1%.
Resumo:
BACKGROUND The safety and efficacy of drug-eluting stents (DES) in the treatment of coronary artery disease have been assessed in several randomised trials. However, none of these trials were powered to assess the safety and efficacy of DES in women because only a small proportion of recruited participants were women. We therefore investigated the safety and efficacy of DES in female patients during long-term follow-up. METHODS We pooled patient-level data for female participants from 26 randomised trials of DES and analysed outcomes according to stent type (bare-metal stents, early-generation DES, and newer-generation DES). The primary safety endpoint was a composite of death or myocardial infarction. The secondary safety endpoint was definite or probable stent thrombosis. The primary efficacy endpoint was target-lesion revascularisation. Analysis was by intention to treat. FINDINGS Of 43,904 patients recruited in 26 trials of DES, 11,557 (26·3%) were women (mean age 67·1 years [SD 10·6]). 1108 (9·6%) women received bare-metal stents, 4171 (36·1%) early-generation DES, and 6278 (54·3%) newer-generation DES. At 3 years, estimated cumulative incidence of the composite of death or myocardial infarction occurred in 132 (12·8%) women in the bare-metal stent group, 421 (10·9%) in the early-generation DES group, and 496 (9·2%) in the newer-generation DES group (p=0·001). Definite or probable stent thrombosis occurred in 13 (1·3%), 79 (2·1%), and 66 (1·1%) women in the bare-metal stent, early-generation DES, and newer-generation DES groups, respectively (p=0·01). The use of DES was associated with a significant reduction in the 3 year rates of target-lesion revascularisation (197 [18·6%] women in the bare-metal stent group, 294 [7·8%] in the early-generation DES group, and 330 [6·3%] in the newer-generation DES group, p<0·0001). Results did not change after adjustment for baseline characteristics in the multivariable analysis. INTERPRETATION The use of DES in women is more effective and safe than is use of bare-metal stents during long-term follow-up. Newer-generation DES are associated with an improved safety profile compared with early-generation DES, and should therefore be thought of as the standard of care for percutaneous coronary revascularisation in women. FUNDING Women in Innovation Initiative of the Society of Cardiovascular Angiography and Interventions.
Resumo:
OBJECTIVES The purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score. BACKGROUND New-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD. METHODS Patient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11). RESULTS A total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042). CONCLUSIONS New-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.
Resumo:
OBJECTIVES This study sought to evaluate: 1) the effect of impaired renal function on long-term clinical outcomes in women undergoing percutaneous coronary intervention (PCI) with drug-eluting stent (DES); and 2) the safety and efficacy of new-generation compared with early-generation DES in women with chronic kidney disease (CKD). BACKGROUND The prevalence and effect of CKD in women undergoing PCI with DES is unclear. METHODS We pooled patient-level data for women enrolled in 26 randomized trials. The study population was categorized by creatinine clearance (CrCl) <45 ml/min, 45 to 59 ml/min, and ≥60 ml/min. The primary endpoint was the 3-year rate of major adverse cardiovascular events (MACE). Participants for whom baseline creatinine was missing were excluded from the analysis. RESULTS Of 4,217 women included in the pooled cohort treated with DES and for whom serum creatinine was available, 603 (14%) had a CrCl <45 ml/min, 811 (19%) had a CrCl 45 to 59 ml/min, and 2,803 (66%) had a CrCl ≥60 ml/min. A significant stepwise gradient in risk for MACE was observed with worsening renal function (26.6% vs. 15.8% vs. 12.9%; p < 0.01). Following multivariable adjustment, CrCl <45 ml/min was independently associated with a higher risk of MACE (adjusted hazard ratio: 1.56; 95% confidence interval: 1.23 to 1.98) and all-cause mortality (adjusted hazard ratio: 2.67; 95% confidence interval: 1.85 to 3.85). Compared with older-generation DES, the use of newer-generation DES was associated with a reduction in the risk of cardiac death, myocardial infarction, or stent thrombosis in women with CKD. The effect of new-generation DES on outcomes was uniform, between women with or without CKD, without evidence of interaction. CONCLUSIONS Among women undergoing PCI with DES, CKD is a common comorbidity associated with a strong and independent risk for MACE that is durable over 3 years. The benefits of newer-generation DES are uniform in women with or without CKD.
Resumo:
BACKGROUND The safety and efficacy of new-generation drug-eluting stents (DES) in women with multiple atherothrombotic risk (ATR) factors is unclear. METHODS AND RESULTS We pooled patient-level data for women enrolled in 26 randomized trials. Study population was categorized based on the presence or absence of high ATR, which was defined as having history of diabetes mellitus, prior percutaneous or surgical coronary revascularization, or prior myocardial infarction. The primary end point was major adverse cardiovascular events defined as a composite of all-cause mortality, myocardial infarction, or target lesion revascularization at 3 years of follow-up. Out of 10 449 women included in the pooled database, 5333 (51%) were at high ATR. Compared with women not at high ATR, those at high ATR had significantly higher risk of major adverse cardiovascular events (15.8% versus 10.6%; adjusted hazard ratio: 1.53; 95% confidence interval: 1.34-1.75; P=0.006) and all-cause mortality. In high-ATR risk women, the use of new-generation DES was associated with significantly lower risk of 3-year major adverse cardiovascular events (adjusted hazard ratio: 0.69; 95% confidence interval: 0.52-0.92) compared with early-generation DES. The benefit of new-generation DES on major adverse cardiovascular events was uniform between high-ATR and non-high-ATR women, without evidence of interaction (Pinteraction=0.14). At landmark analysis, in high-ATR women, stent thrombosis rates were comparable between DES generations in the first year, whereas between 1 and 3 years, stent thrombosis risk was lower with new-generation devices. CONCLUSIONS Use of new-generation DES even in women at high ATR is associated with a benefit consistent over 3 years of follow-up and a substantial improvement in very-late thrombotic safety.
Resumo:
BACKGROUND Diabetes mellitus and angiographic coronary artery disease complexity are intertwined and unfavorably affect prognosis after percutaneous coronary interventions, but their relative impact on long-term outcomes after percutaneous coronary intervention with drug-eluting stents remains controversial. This study determined drug-eluting stents outcomes in relation to diabetic status and coronary artery disease complexity as assessed by the Synergy Between PCI With Taxus and Cardiac Surgery (SYNTAX) score. METHODS AND RESULTS In a patient-level pooled analysis from 4 all-comers trials, 6081 patients were stratified according to diabetic status and according to the median SYNTAX score ≤11 or >11. The primary end point was major adverse cardiac events, a composite of cardiac death, myocardial infarction, and clinically indicated target lesion revascularization within 2 years. Diabetes mellitus was present in 1310 patients (22%), and new-generation drug-eluting stents were used in 4554 patients (75%). Major adverse cardiac events occurred in 173 diabetics (14.5%) and 436 nondiabetic patients (9.9%; P<0.001). In adjusted Cox regression analyses, SYNTAX score and diabetes mellitus were both associated with the primary end point (P<0.001 and P=0.028, respectively; P for interaction, 0.07). In multivariable analyses, diabetic versus nondiabetic patients had higher risks of major adverse cardiac events (hazard ratio, 1.25; 95% confidence interval, 1.03-1.53; P=0.026) and target lesion revascularization (hazard ratio, 1.54; 95% confidence interval, 1.18-2.01; P=0.002) but similar risks of cardiac death (hazard ratio, 1.41; 95% confidence interval, 0.96-2.07; P=0.08) and myocardial infarction (hazard ratio, 0.89; 95% confidence interval, 0.64-1.22; P=0.45), without significant interaction with SYNTAX score ≤11 or >11 for any of the end points. CONCLUSIONS In this population treated with predominantly new-generation drug-eluting stents, diabetic patients were at increased risk for repeat target-lesion revascularization consistently across the spectrum of disease complexity. The SYNTAX score was an independent predictor of 2-year outcomes but did not modify the respective effect of diabetes mellitus. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifiers: NCT00297661, NCT00389220, NCT00617084, and NCT01443104.
Resumo:
Objective. To determine the accuracy of the urine protein:creatinine ratio (pr:cr) in predicting 300 mg of protein in 24-hour urine collection in pregnant patients with suspected preeclampsia. ^ Methods. A systematic review was performed. Articles were identified through electronic databases and the relevant citations were hand searching of textbooks and review articles. Included studies evaluated patients for suspected preeclampsia with a 24-hour urine sample and a pr:cr. Only English language articles were included. The studies that had patients with chronic illness such as chronic hypertension, diabetes mellitus or renal impairment were excluded from the review. Two researchers extracted accuracy data for pr:cr relative to a gold standard of 300 mg of protein in 24-hour sample as well as population and study characteristics. The data was analyzed and summarized in tabular and graphical form. ^ Results. Sixteen studies were identified and only three studies met our inclusion criteria with 510 total patients. The studies evaluated different cut-points for positivity of pr:cr from 130 mg/g to 700 mg/g. Sensitivities and specificities for pr:cr of 130mg/g -150 mg/g were 90-93% and 33-65%, respectively; for a pr:cr of 300 mg/g were 81-95% and 52-80%, respectively; for a pr:cr of 600-700mg/g were 85-87% and 96-97%, respectively. ^ Conclusion. The value of a random pr:cr to exclude pre-eclampsia is limited because even low levels of pr:cr (130-150 mg/g) may miss up to 10% of patients with significant proteinuria. A pr:cr of more than 600 mg/g may obviate a 24-hour collection.^
Resumo:
This study is a retrospective longitudinal study at Texas Children's Hospital, a 350-bed tertiary level pediatric teaching hospital in Houston, Texas, for the period 1990 to 2006. It measured the incidence and trends of positive pre-employment drug tests among new job applicants At TCH. ^ Over the study period, 16,219 job applicants underwent pre-employment drug screening at TCH. Of these, 330 applicants (2%) tested positive on both the EMIT and GC/MS. After review by the medical review officer, the number of true drug test positive applicants decreased to 126 (0.78%). ^ According to the overall annual positive drug test incidence rates, the highest overall incidence was in 2002 (14.71 per 1000 tests) and the lowest in 2004 (3.17 per 1000 tests). Despite a marked increase in 2002, over the 15-year study period the overall incidence tended to decrease. Incidence rates and trends of other illegal drugs are further discussed in the study. And in general, these incidence rates also decline in the study period. In addition to that, we found the overall, positive drug tests were more common in females than in males (55.5% versus 44.4%). ^
Resumo:
Mode of access: Internet.
Resumo:
Aims: Identification of a gene for self-protection from the antibiotic-producing plant pathogen Xanthomonas albilineans, and functional testing by heterologous expression. Methods and Results: Albicidin antibiotics and phytotoxins are potent inhibitors of prokaryote DNA replication. A resistance gene (albF) isolated by shotgun cloning from the X. albilineans albicidin-biosynthesis region encodes a protein with typical features of DHA14 drug efflux pumps. Low-level expression of albF in Escherichia coli increased the MIC of albicidin 3000-fold, without affecting tsx-mediated albicidin uptake into the periplasm or resistance to other tested antibiotics. Bioinformatic analysis indicates more similarity to proteins involved in self-protection in polyketide-antibiotic-producing actinomycetes than to multi-drug resistance pumps in other Gram-negative bacteria. A complex promoter region may co-regulate albF with genes for hydrolases likely to be involved in albicidin activation or self-protection. Conclusions: AlbF is the first apparent single-component antibiotic-specific efflux pump from a Gram-negative antibiotic producer. It shows extraordinary efficiency as measured by resistance level conferred upon heterologous expression. Significance and Impact of the Study: Development of the clinical potential of albicidins as potent bactericidial antibiotics against diverse bacteria has been limited because of low yields in culture. Expression of albF with recently described albicidin-biosynthesis genes may enable large-scale production. Because albicidins are X. albilineans pathogenicity factors, interference with AlbF function is also an opportunity for control of the associated plant disease.