942 resultados para contrast thresholds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnetic resonance imaging contrast agent, the so-called Endorem (TM) colloidal suspension on the basis of superparamagnetic iron oxide nanoparticles (mean diameter of 5.5 nm) coated with dextran, were characterized on the basis of several measurement techniques to determine the parameters of their most important physical and chemical properties. It is assumed that each nanoparticle is consisted of Fe(3)O(4) monodomain and it was observed that its oxidation to gamma-Fe(2)O(3) occurs at 253.1 degrees C. The Mossbauer spectroscopy have shown a superparamagnetic behavior of the magnetic nanoparticles. The Magnetic Resonance results show an increase of the relaxation times T(1), T(2), and T(2)* with decreasing concentration of iron oxide nanoparticles. The relaxation effects of SPIONs contrast agents are influenced by their local concentration as well as the applied field strength and the environment in which these agents interact with surrounding protons. The proton relaxation rates presented a linear behavior with concentration. The measured values of thermooptic coefficient partial derivative n/partial derivative T, thermal conductivity K, optical birefringence Delta n(0), nonlinear refractive index n(2), nonlinear absorption beta` and third-order nonlinear susceptibility vertical bar chi((3))vertical bar are also reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is a report of the characterization of superparamagnetic iron oxide nanoparticles coated with silicone used as a contrast agent in magnetic resonance imaging of the gastrointestinal tract. The hydrodynamic size of the contrast agent is 281.2 rim, where it was determined by transmission electron microscopy and a Fe(3)O(4) crystalline structure was identified by X-ray diffraction, also confirmed by Mossbauer Spectroscopy. The blocking temperature of 190 K was determined from magnetic measurements based on the Zero Field Cooled and Field Cooled methods. The hysteresis loops were measured at different temperatures below and above the blocking temperature. Ferromagnetic resonance analysis indicated the superparamagnetic nature of the nanoparticles and a strong temperature dependence of the peak-to-peak linewidth Delta H(pp), giromagnetic factor g, number of spins N(S) and relaxation time T(2) were observed. This behavior can be attributed to an increase in the superexchange interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to establish parameters for the gaps-in-noise test in normal-hearing young adults. One hundred subjects (50 males and 50 females) received an audiological evaluation to rule out hearing loss and auditory processing disorder. The gaps-in-noise test was then conducted on all subjects. The mean gap detection threshold was 4.19 ms. A psychometric function by gap duration was constructed, revealing that the percentage of correct responses was less than or equal to 5% for a gap duration of 2 ms, 10-30% for a gap duration of 3 ms, 60-70% for a gap duration of 4 ms, and over 96% for gap durations of 5 ms or longer. The results suggest that the data obtained can be applied as reference values for future testing. In the subjects evaluated, the gaps-in-noise test proved to be consistent with low variability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conclusion. The study shows that there are differences in the measurement of the action potentials with and without the stylet in the Nucleus Freedom Contour Advance that are higher in the apex than in the base of the cochlea. Objectives. To determine if there are differences in the intraoperative impedances and in the neural response telemetry threshold values in the Nucleus Freedom Contour Advance before and after stylet removal. Subjects and methods. This was a prospective clinical study. Intraoperative impedances and neural response telemetry in users of the Freedom Contour Advance Cochlear Implant were measured before and after stylet removal. Results. There was a significant reduction in the impedance values of an average 1.5 k Omega +/- 2.3 in common ground mode and 1.3 k Omega +/- 2.3 for all monopolar modes after the stylet removal (p < 0.001). When analyzing the apical, medium, and basal electrodes, there was a statistically significant reduction in the neural response thresholds after stylet removal only in the apical electrodes (p = 0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the analgesic effects of unilateral repetitive transcranial magnetic stimulation (rTMS) of the motor cortex (M1) or dorsolateral prefrontal cortex (DLPFC) in two models of experimental pain in healthy volunteers. Two studies were carried out in parallel in two groups of 26 paid healthy volunteers. The effects of active or sham rTMS (frequency, 10 Hz; intensity, 80% resting motor threshold) applied to the right M1 or DLPFC were compared in a double-blind randomized cross-over design. In the first series of experiments, we analyzed the effects of rTMS on thermal (heat and cold) detection and pain thresholds measured on both hands and the left foot, by standardized quantitative sensory testing methods. In the second series of experiments, we measured the effects of M1 or DLPFC rTMS on the threshold and recruitment curves of the RIII nociceptive reflex evoked by ipsilateral electrical stimulation of the sural nerve and recorded on the biceps femoris of both lower limbs. In both studies, measurements were taken before and up to 60 min after the end of rTMS. Active rTMS of both M1 and DLPFC significantly increased the thermal pain thresholds, measured for both hands and the left foot, this effect being most marked for cold pain. These effects, which lasted at least 1 h after rTMS, were selective because they were not associated with changes in non-painful thermal sensations. By contrast, the second study showed that rTMS of M1 or DLPFC had no significant effect on the threshold or recruitment curve of the nociceptive flexion RIII reflex. Our findings demonstrate that unilateral rTMS of M1 or DLPFC induces diffuse and selective analgesic effects in healthy volunteers. The lack of effect on the RIII reflex suggests that such analgesic effects may not depend on the activation of descending inhibitory systems. (C) 2009 International Association for the Study of Pain. Published by Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). Methods and results Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and A beta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (0). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and A beta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and A beta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and A beta reserves, respectively. Conclusion Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Chronic aortic valve disease (AVD) is characterized by progressive accumulation of interstitial myocardial fibrosis (MF). However, assessment of MF accumulation has only been possible through histologic analyses of endomyocardial biopsies. We sought to evaluate contrast-enhanced magnetic resonance imaging (ce-MRI) as a noninvasive method to identify the presence of increased MF in patients with severe AVD. Methods Seventy patients scheduled to undergo aortic valve replacement surgery were examined by cine and ce-MRI in a 1.5-T scanner. Cine images were used for the assessment of left ventricular (LV) volumes, mass, and function. Delayed-enhancement images were used to characterize the regions of MF. In addition, histologic analyses of myocardial samples obtained during aortic valve replacement surgery were used for direct quantification of interstitial MF. Ten additional subjects who died of noncardiac causes served as controls for the quantitative histologic analyses. Results Interstitial MF determined by histopathologic analysis was higher in patients with AVID than in controls (2.7% +/- 2.0% vs 0.6% +/- 0.2%, P =.001). When compared with histopathologic results, ce-MRI demonstrated a sensitivity of 74%, a specificity of 81%, and an accuracy of 76% to identify AVD patients with increased interstitial MF There was a significant inverse correlation between interstitial MF and LV ejection fraction (r = -0.67, P <.0001). Accordingly, patients with identifiable focal regions of MF by ce-MRI exhibited worse LV systolic function than those without MF (45% +/- 14% vs 65% +/- 14%, P <.0001). Conclusions Contrast-enhanced MRI allows for the noninvasive detection of focal regions of MF in patients with severe AVD. Moreover, patients with identifiable MF by ce-MRI exhibited worse LV functional parameters. (Am Heart J 2009; 157:361-8.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to estimate and contrast the occurrence of ictal and interictal cutaneous allodynia (CA) in individuals with migraine with and without temporomandibular disorders (TMD). Both TMD and CA are common in migraine and may be associated with migraine transformation from episodic into a chronic form. Herein we hypothesize that TMD contributes to the development of CA and to more severe headaches. In a clinic-based sample of individuals with episodic migraine, the presence of TMD was assessed using the research diagnostic criteria for myofascial or mixed (myofascial and arthralgic) TMD. Ictal CA was quantified using the validated Allodynia Symptom Checklist (ASC-12). The ASC-12 measures CA over the preceding month by asking 12 questions about the frequency of allodynia symptoms during headaches. Interictal CA was assessed in the domains of heat, cold and mechanical static allodynia using quantitative sensory testing. Our sample consists of 55 individuals; 40 (73%) had TMD (23 with myofascial TMD and 17 with the mixed type). CA of any severity (as assessed by ASC-12) occurred in 40% of those without TMD (reference group), 86.9% of those with myofascial TMD (P = 0.041, RR = 3.2, 95% CI = 1.5-7.0) and in 82.3% of those with mixed TMD (P = 0.02, RR = 2.5, 95% CI = 1.2-5.3). Individuals with TMD were more likely to have moderate or severe CA associated with their headaches. Interictally (quantitative sensory testing), thresholds for heat and mechanical nociception were significantly lower in individuals with TMD. Cold nociceptive thresholds were not significantly different in migraine patients with and without TMD. TMDs were also associated with change in extra-cephalic pain thresholds. In logistical regression, TMD remained associated with CA after adjusting for aura, gender and age. TMD and CA are associated in individuals with migraine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the advantages and disadvantages of the new low-addition (add) (+3.00 diopter [D]) ReSTOR multifocal IOL compared with the preceding ReSTOR model with +4.00 D add. SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Comparative case series. METHODS: Patients with a +3.00 D or +4.00 D add multifocal IOL were examined for uncorrected and distance-corrected visual acuity at distance, intermediate, and near. A defocus profile was assessed, individual reading distance and the distance for lowest intermediate visual acuity were determined. Patient satisfaction was evaluated with a standardized questionnaire. Contrast sensitivity was tested under mesopic and photopic conditions. RESULTS: Uncorrected and distance-corrected intermediate visual acuities were statistically significantly better in the +3.00 D add group (24 eyes) than in the +4.00 D add group (30 eyes); distance and near visual acuities were not different between groups. The defocus profile significantly varied between groups. The +4.00 D add group had a closer reading distance (33.0 cm) than the +3.00 D add group (43.5 cm), a closer point of lowest intermediate visual acuity (65.8 cm versus 86.9 cm) and worse lowest intermediate visual acuity (20/59 +/- 4.5 letters [SD] versus 20/48 +/- 5.5 letters). Thus, patients in the +3.00 D add group reported being more satisfied with intermediate visual acuity. The +3.00 D add group reported more glare but less halos than the +4.00 D add group; contrast sensitivity was not different. CONCLUSION: The lower addition resulted in a narrower defocus profile, a farther reading distance, and better intermediate visual acuity and thus increased patient satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Patients with early age-related maculopathy ( ARM) do not necessarily show obvious morphological signs or functional impairment. Many have good visual acuity, yet complain of decreased visual performance. The aim of this study was to investigate the aging effects on performance of parafoveal letter recognition at reduced contrast, and defects caused by early ARM and normal fellow eyes of patients with unilateral age-related macular degeneration (nfAMD). Methods Testing of the central visual field (8 radius) was performed by the Macular Mapping Test (MMT) using recognition of letters in 40 parafoveal target locations at four contrast levels (5, 10, 25 and 100%). Effects of aging were investigated in 64 healthy subjects aged 23 to 76 years (CTRL). In addition, 39 eyes (minimum visual acuity of 0.63; 20/30) from 39 patients with either no visible signs of ARM, while the fellow eye had advanced age-related macular degeneration (nfAMD; n=12), or early signs of ARM (eARM; n=27) were examined. Performance was expressed summarily as a ""field score"" (FS). Results Performance in the MMT begins to decline linearly with age in normal subjects from the age of 50 and 54 years on, at 5% and 10% contrast respectively. The differentiation between patients and CTRLs was enhanced if FS at 5% was analyzed along with FS at 10% contrast. In 8/12 patients from group nfAMD and in 18/27 from group eARM, the FS was statistically significantly lower than in the CTRL group in at least one of the lower contrast levels. Conclusion Using parafoveal test locations, a recognition task and diminished contrast increases the chance of early detection of functional defects due to eARM or nfAMD and can differentiate them from those due to aging alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To introduce a comprehensive and reliable scoring system for the assessment of whole-knee joint synovitis based on contrast-enhanced (CE) MRI. Methods Multicenter Osteoarthritis Study (MOST) is a cohort study of people with, or at high risk of, knee osteoarthritis (OA). Subjects are an unselected subset of MOST who volunteered for CE-MRI. Synovitis was assessed at 11 sites of the joint. Synovial thickness was scored semiquantitatively: grade 0 (< 2 mm), grade 1 (2-4 mm) and grade 2 (> 4 mm) at each site. Two musculoskeletal radiologists performed the readings and inter-and intrareader reliability was evaluated. Whole-knee synovitis was assessed by summing the scores from all sites. The association of Western Ontario and McMaster Osteoarthritis Index pain score with this summed score and with the maximum synovitis grade for each site was assessed. Results 400 subjects were included (mean age 58.8 +/- 7.0 years, body mass index 29.5 +/- 4.9 kg/m(2), 46% women). For individual sites, intrareader reliability (weighted kappa) was 0.67-1.00 for reader 1 and 0.60-1.00 for reader 2. Inter-reader agreement (kappa) was 0.67-0.92. For the summed synovitis scores, intrareader reliability (intraclass correlation coefficient (ICC)) was 0.98 and 0.96 for each reader and inter-reader agreement (ICC) was 0.94. Moderate to severe synovitis in the parapatellar subregion was associated with the higher maximum pain score (adjusted OR (95% CI), 2.8 (1.4 to 5.4) and 3.1 (1.2 to 7.9), respectively). Conclusions A comprehensive semiquantitative scoring system for the assessment of whole-knee synovitis is proposed. It is reliable and identifies knees with pain, and thus is a potentially powerful tool for synovitis assessment in epidemiological OA studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were (1) to determine the sensitivity (Se) and specificity (Sp) of somatic cell count (SCC) thresholds to identify subclinical mastitis in Gyr cows caused by major and minor pathogens; (2) to study the effects of month of sampling, rear or front mammary quarters, herd, intramammary infection (IMI), and bacterial species on SCC at quarter level; and (3) to describe the prevalence of IMI in Gyr cows in commercial dairy herds. In total, 221 lactating Gyr cows from 3 commercial dairy farms were selected. Milk samples were collected from individual quarters once a month for 1 yr from all lactating cows for SCC and bacteriological analysis. Mammary quarters were considered the experimental units and the SCC results were log(10)-transformed. Four SCC thresholds (100, 200, 300 and 400 x 10(3) cells/mL) were used to determine Se and Sp to identify infected mammary quarters. The overall prevalence of IMI in quarter milk samples of Gyr cows was 49.8%, and the prevalence of minor pathogens was higher (31.9%) than that of major pathogens (17.8%). Quarter samples with microbial isolation presented higher SCC compared with negative samples. Sensitivity and Sp of selected SCC thresholds varied according to the group of pathogen (major and minor) involved in the IMI definition. Sensitivity increased and Sp decreased when mammary quarters with only major pathogens isolation were considered positive. The use of a single SCC analysis to classify quarters as uninfected or infected in Gyr cows may not be a useful test for this breed because Se and Sp of SCC at the studied thresholds were low. The occurrence of IMI and the bacterial species are the main factors responsible for SCC variation in mammary quarters of Gyr cows. Milk samples with major pathogens isolation elicited higher SCC than those with minor pathogens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of lateral epicondylalgia, a widely-used model of musculoskeletal pain in the evaluation of many physical therapy treatments, remains somewhat of an enigma. The protagonists of a new treatment technique for lateral epicondylalgia report that it produces substantial and rapid pain relief, despite a lack of experimental evidence. A randomized, double blind, placebo-controlled repeated-measures study evaluated the initial effect of this new treatment in 24 patients with unilateral, chronic lateral epicondylalgia. Pain-free grip strength was assessed as an outcome measure before, during and after the application of the treatment, placebo and control conditions. Pressure-pain thresholds were also measured before and after the application of treatment, placebo and control conditions. The results demonstrated a significant and substantial increase in pain-free grip strength of 58% (of the order of 60 N) during treatment but not during placebo and control. In contrast, the 10% change in pressure-pain threshold after treatment, although significantly greater than placebo and control, was substantially smaller than the change demonstrated for pain-free grip strength. This effect was only present in the affected limb. The selective and specific effect of this treatment technique provides a valuable insight into the physical modulation of musculoskeletal pain and requires further investigation. (C) 2001 Harcourt Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. Design-Cohort study. Setting-Regional cardiothoracic unit. Patients-49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. Main outcome measures-Regional myocardial perfusion by SPECT, performed with Tc-99m tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. Results-Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wail, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. Conclusions-Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.