970 resultados para active method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new practical method to generate a subspace of active coordinates for quantum dynamics calculations is presented. These reduced coordinates are obtained as the normal modes of an analytical quadratic representation of the energy difference between excited and ground states within the complete active space self-consistent field method. At the Franck-Condon point, the largest negative eigenvalues of this Hessian correspond to the photoactive modes: those that reduce the energy difference and lead to the conical intersection; eigenvalues close to 0 correspond to bath modes, while modes with large positive eigenvalues are photoinactive vibrations, which increase the energy difference. The efficacy of quantum dynamics run in the subspace of the photoactive modes is illustrated with the photochemistry of benzene, where theoretical simulations are designed to assist optimal control experiments

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D X-ray reconstruc-tion angiography (3DRA) and time of °ight magnetic resonance angiography (TOF-MRA) images available in the clinical routine.Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using di®erent imaging equipment. Evaluation included qualitative and quantitative analyses ofthe segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: iso-intensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an inter-modality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE di®ered from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE, respectively) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatabilityof GAR was superior to manual measurements and ISE. The inter-modality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The outcome of Kaposi sarcoma varies. While many patients do well on highly active antiretroviral therapy, others have progressive disease and need chemotherapy. In order to predict which patients are at risk of unfavorable evolution, we established a prognostic score. METHOD: The survival analysis (Kaplan-Meier method; Cox proportional hazards models) of 144 patients with Kaposi sarcoma prospectively included in the Swiss HIV Cohort Study, from January 1996 to December 2004, was conducted. OUTCOME ANALYZED: use of chemotherapy or death. VARIABLES ANALYZED: demographics, tumor staging [T0 or T1 (16)], CD4 cell counts and HIV-1 RNA concentration, human herpesvirus 8 (HHV8) DNA in plasma and serological titers to latent and lytic antigens. RESULTS: Of 144 patients, 54 needed chemotherapy or died. In the univariate analysis, tumor stage T1, CD4 cell count below 200 cells/microl, positive HHV8 DNA and absence of antibodies against the HHV8 lytic antigen at the time of diagnosis were significantly associated with a bad outcome.Using multivariate analysis, the following variables were associated with an increased risk of unfavorable outcome: T1 [hazard ratio (HR) 5.22; 95% confidence interval (CI) 2.97-9.18], CD4 cell count below 200 cells/microl (HR 2.33; 95% CI 1.22-4.45) and positive HHV8 DNA (HR 2.14; 95% CI 1.79-2.85).We created a score with these variables ranging from 0 to 4: T1 stage counted for two points, CD4 cell count below 200 cells/microl for one point, and positive HHV8 viral load for one point. Each point increase was associated with a HR of 2.26 (95% CI 1.79-2.85). CONCLUSION: In the multivariate analysis, staging (T1), CD4 cell count (<200 cells/microl), positive HHV8 DNA in plasma, at the time of diagnosis, predict evolution towards death or the need of chemotherapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we propose two active learning algorithms for semiautomatic definition of training samples in remote sensing image classification. Based on predefined heuristics, the classifier ranks the unlabeled pixels and automatically chooses those that are considered the most valuable for its improvement. Once the pixels have been selected, the analyst labels them manually and the process is iterated. Starting with a small and nonoptimal training set, the model itself builds the optimal set of samples which minimizes the classification error. We have applied the proposed algorithms to a variety of remote sensing data, including very high resolution and hyperspectral images, using support vector machines. Experimental results confirm the consistency of the methods. The required number of training samples can be reduced to 10% using the methods proposed, reaching the same level of accuracy as larger data sets. A comparison with a state-of-the-art active learning method, margin sampling, is provided, highlighting advantages of the methods proposed. The effect of spatial resolution and separability of the classes on the quality of the selection of pixels is also discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Achieving a high degree of dependability in complex macro-systems is challenging. Because of the large number of components and numerous independent teams involved, an overview of the global system performance is usually lacking to support both design and operation adequately. A functional failure mode, effects and criticality analysis (FMECA) approach is proposed to address the dependability optimisation of large and complex systems. The basic inductive model FMECA has been enriched to include considerations such as operational procedures, alarm systems. environmental and human factors, as well as operation in degraded mode. Its implementation on a commercial software tool allows an active linking between the functional layers of the system and facilitates data processing and retrieval, which enables to contribute actively to the system optimisation. The proposed methodology has been applied to optimise dependability in a railway signalling system. Signalling systems are typical example of large complex systems made of multiple hierarchical layers. The proposed approach appears appropriate to assess the global risk- and availability-level of the system as well as to identify its vulnerabilities. This enriched-FMECA approach enables to overcome some of the limitations and pitfalls previously reported with classical FMECA approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gene correction at the site of the mutation in the chromosome is the absolute way to really cure a genetic disease. The oligonucleotide (ODN)-mediated gene repair technology uses an ODN perfectly complementary to the genomic sequence except for a mismatch at the base that is mutated. The endogenous repair machinery of the targeted cell then mediates substitution of the desired base in the gene, resulting in a completely normal sequence. Theoretically, it avoids potential gene silencing or random integration associated with common viral gene augmentation approaches and allows an intact regulation of expression of the therapeutic protein. The eye is a particularly attractive target for gene repair because of its unique features (small organ, easily accessible, low diffusion into systemic circulation). Moreover therapeutic effects on visual impairment could be obtained with modest levels of repair. This chapter describes in details the optimized method to target active ODNs to the nuclei of photoreceptors in neonatal mouse using (1) an electric current application at the eye surface (saline transpalpebral iontophoresis), (2) combined with an intravitreous injection of ODNs, as well as the experimental methods for (3) the dissection of adult neural retinas, (4) their immuno-labelling, and (5) flat-mounting for direct observation of photoreceptor survival, a relevant criteria of treatment outcomes for retinal degeneration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The development of novel therapies and the increasing number of trials testing management strategies for luminal Crohn's disease (CD) have not filled all the gaps in our knowledge. Thus, in clinical practice, many decisions for CD patients need to be taken without high quality evidence. For this reason, a multidisciplinary European expert panel followed the RAND method to develop explicit criteria for the management of individual patients with active, steroid-dependent (ST-D) and steroid-refractory (ST-R) CD. Methods: Twelve international experts convened in Geneva, Switzerland in December 2007, to rate explicit clinical scenarios, corresponding to real daily practice, on a 9-point scale according to the literature evidence and their own expertise. Median ratings were stratified into three categories: appropriate (7-9), uncertain (4-6) and inappropriate (1-3). Results: Overall, panelists rated 296 indications pertaining to mild-to-moderate, severe, ST-D, and ST-R CD. In anti-TNF naïve patients, budesonide and prednisone were found appropriate for mildmoderate CD, and infliximab (IFX) when those had previously failed or had not been tolerated. In patients with prior success with IFX, this drug with or without co-administration of a thiopurine analog was favored. Other anti-TNFs were appropriate in case of intolerance or resistance to IFX. High doses steroids, IFX or adalimumab were appropriate in severe active CD. Among 105 indications for ST-D or ST-R disease, the panel considered appropriate the thiopurine analogs, methotrexate, IFX, adalimumab and surgery for limited resection, depending on the outcome of prior therapies. Anti-TNFs were generally considered appropriate in ST-R. Conclusion: Steroids, including budesonide for mild-to-moderate CD, remain first-line therapies in active luminal CD. Anti-TNFs, in particular IFX with respect to the amount of available evidence, remain second-line for most indications. Thiopurine analogs are preferred to anti-TNFs when steroids are not appropriate, except when anti-TNFs were previously successful. These recommendations are available online (www.epact.ch). A prospective evaluation of these criteria in a large database in Switzerland in underway to validate these criteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present an efficient numerical scheme for the recently introduced geodesic active fields (GAF) framework for geometric image registration. This framework considers the registration task as a weighted minimal surface problem. Hence, the data-term and the regularization-term are combined through multiplication in a single, parametrization invariant and geometric cost functional. The multiplicative coupling provides an intrinsic, spatially varying and data-dependent tuning of the regularization strength, and the parametrization invariance allows working with images of nonflat geometry, generally defined on any smoothly parametrizable manifold. The resulting energy-minimizing flow, however, has poor numerical properties. Here, we provide an efficient numerical scheme that uses a splitting approach; data and regularity terms are optimized over two distinct deformation fields that are constrained to be equal via an augmented Lagrangian approach. Our approach is more flexible than standard Gaussian regularization, since one can interpolate freely between isotropic Gaussian and anisotropic TV-like smoothing. In this paper, we compare the geodesic active fields method with the popular Demons method and three more recent state-of-the-art algorithms: NL-optical flow, MRF image registration, and landmark-enhanced large displacement optical flow. Thus, we can show the advantages of the proposed FastGAF method. It compares favorably against Demons, both in terms of registration speed and quality. Over the range of example applications, it also consistently produces results not far from more dedicated state-of-the-art methods, illustrating the flexibility of the proposed framework.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present the segmentation of the headand neck lymph node regions using a new active contourbased atlas registration model. We propose to segment thelymph node regions without directly including them in theatlas registration process; instead, they are segmentedusing the dense deformation field computed from theregistration of the atlas structures with distinctboundaries. This approach results in robust and accuratesegmentation of the lymph node regions even in thepresence of significant anatomical variations between theatlas-image and the patient's image to be segmented. Wealso present a quantitative evaluation of lymph noderegions segmentation using various statistical as well asgeometrical metrics: sensitivity, specificity, dicesimilarity coefficient and Hausdorff distance. Acomparison of the proposed method with two other state ofthe art methods is presented. The robustness of theproposed method to the atlas selection, in segmenting thelymph node regions, is also evaluated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The development of novel therapies and the increasing number of trials testing management strategies for luminal Crohn's disease (CD) have not filled all the gaps in our knowledge. Thus, in clinical practice, many decisions for CD patients need to be taken without high quality evidence. For this reason, a multidisciplinary European expert panel followed the RAND method to develop explicit criteria for the management of individual patients with active, steroid-dependent (ST-D) and steroid-refractory (ST-R) CD. Methods: Twelve international experts convened in Geneva, Switzerland in December 2007, to rate explicit clinical scenarios, corresponding to real daily practice, on a 9-point scale according to the literature evidence and their own expertise. Median ratings were stratified into three categories: appropriate (7-9), uncertain (4-6) and inappropriate (1-3). Results: Overall, panelists rated 296 indications pertaining to mild-to-moderate, severe, ST-D, and ST-R CD. In anti-TNF naïve patients, budesonide and prednisone were found appropriate for mildmoderate CD, and infliximab (IFX) when those had previously failed or had not been tolerated. In patients with prior success with IFX, this drug with or without co-administration of a thiopurine analog was favored. Other anti-TNFs were appropriate in case of intolerance or resistance to IFX. High doses steroids, IFX or adalimumab were appropriate in severe active CD. Among 105 indications for ST-D or ST-R disease, the panel considered appropriate the thiopurine analogs, methotrexate, IFX, adalimumab and surgery for limited resection, depending on the outcome of prior therapies. Anti-TNFs were generally considered appropriate in ST-R. Conclusion: Steroids, including budesonide for mild-to-moderate CD, remain first-line therapies in active luminal CD. Anti-TNFs, in particular IFX with respect to the amount of available evidence, remain second-line for most indications. Thiopurine analogs are preferred to anti-TNFs when steroids are not appropriate, except when anti-TNFs were previously successful. These recommendations are available online (www.epact.ch). A prospective evaluation of these criteria in a large database in Switzerland in underway to validate these criteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Bone cements and substitutes are commonly used in surgery to deliver antibiotics locally. The objective of this study was to assess the systemic absorption and disposition of vancomycin in patients treated with active calcium sulfate bone filler and to predict systemic concentrations under various conditions. Method: 277 blood samples were taken from 42 patients receiving vancomycin in bone cement during surgery. Blood samples were collected from 3h to 10 days after implantation. Vancomycin was measured by immunoenzymatic assay. Population pharmacokinetic (PK) analysis was performed using NONMEM to assess average estimates and variability of PK parameters. Based on the final model, simulations with various doses and renal function levels were performed. Results: The patients were 64 ± 20 years old, their body weight was 81 ± 22 kg and Cockcroft-Gault creatinine clearance (CLcr) 98 ± 55 mL/min. Vancomycin doses ranged from 200 mg to 6000 mg and implantation sites were hip (n=16), tibia (10) or others (16). Concentration profiles remained low and consistent with absorption rate-limited first-order release, while showing prominent variability. Mean clearance (CL) was 3.87 L/h (CV 35%), absorption rate constant (ka) 0.004 h-1 (66%) and volume of distribution (V) 9.5 L. Simulations with up to 8000 mg vancomycin implant showed systemic concentrations exceeding 20 mg/L for 3.5 days in 43% of the patients with CLcr 15 mL/min, whereas 7% of the patients with normal renal function had a concentration above 20 mg/L for 1.1 days. Subtherapeutic concentrations (0.4-4 mg/L) were predicted during a median of 22 days in patients with normal renal function and 4000 mg vancomycin implant, with limited influence of dose or renal function. Conclusion: Vancomycin-laden calcium sulfate implant does not raise toxicity concern. Selection of resistant bacteria, such as Enterococcus and Staphylococcus species, might however be a concern, as simulations show persistent subtherapeutic systemic concentrations during 3 to 4 weeks in these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paclitaxel (Tx)-loaded anti-HER2 immunonanoparticles (NPs-Tx-HER) were prepared by the covalent coupling of humanized monoclonal anti-HER2 antibodies (trastuzumab, Herceptin) to Tx-loaded poly (dl-lactic acid) nanoparticles (NPs-Tx) for the active targeting of tumor cells that overexpress HER2 receptors. The physico-chemical properties of NPs-Tx-HER were compared to unloaded immunonanoparticles (NPs-HER) to assess the influence of the drug on anti-HER2 coupling to the NP surface. The immunoreactivity of sulfo-MBS activated anti-HER2 mAbs and the in vitro efficacy of NPs-Tx-HER were tested on SKOV-3 ovarian cancer cells that overexpress HER2 antigens. Tx-loaded nanoparticles (NPs-Tx) obtained by a salting-out method had a size of 171+/-22 nm (P.I.=0.1) and an encapsulation efficiency of about of 78+/-10%, which corresponded to a drug loading of 7.8+/-0.8% (w/w). NPs-Tx were then thiolated and conjugated to activated anti-HER2 mAbs to obtain immunonanoparticles of 237+/-43 nm (P.I.=0.2). The influence of the activation step on the immunoreactivity of the mAbs was tested on SKOV-3 cells using 125I-radiolabeled mAbs, and the activity of the anti-HER2 mAbs was minimally affected after sulfo-MBS functionalization. Approximately 270 molecules of anti-HER2 mAbs were bound per nanoparticle. NPs-Tx-HER exhibited a zeta potential of 0.2+/-0.1 mV. The physico-chemical properties of the Tx-loaded immunonanoparticles were very similar to unloaded immunonanoparticles, suggesting that the encapsulation of the drug did not influence the coupling of the mAbs to the NPs. No drug loss was observed during the preparation process. DSC analysis showed that encapsulated Tx is in an amorphous or disordered-crystalline phase. These results suggest that Tx is entrapped in the polymeric matrix and not adsorbed to the surface of the NPs. In vitro studies on SKOV-3 ovarian cancer cells demonstrated the greater cytotoxic effect of NPs-Tx-HER compared to other Tx formulations. The results showed that at 1 ng Tx/ml, the viability of cells incubated with drug encapsulated in NP-Tx-HER was lower (77.32+/-5.48%) than the viability of cells incubated in NPs-Tx (97.4+/-12%), immunonanoparticles coated with Mabthera, as irrelevant mAb (NPs-Tx-RIT) (93.8+/-12%) or free drug (92.3+/-9.3%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Listeria monocytogenes was inoculated on the surface of sliced fermented sausages with no added sodium salt. The pathogen was progressively inactivated during the product shelf life (90 days). Antimicrobial packaging of fermented sausages with PVOH films containing nisin induced a more pronounced reduction of L. monocytogenes counts during refrigerated storage. HPP alone (600 MPa, 5 min, 12 °C) had no antimicrobial effect against L. monocytogenes at the studied conditions. Combination of HPP with antimicrobial packaging did not produce any extra protection against L. monocytogenes compared to antimicrobial packaging alone. The lack of effect of HPP on L. monocytogenes was attributed to a protective effect exerted by the low water activity of the product and its lactate content. These results reflect that antimicrobial packaging with the inclusion of nisin as a natural antimicrobial could be considered as an effective method to reduce the levels of L. monocytogenes in sliced fermented sausages with no added sodium salt

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different compounds have been reported as biomarkers of a smoking habit, but, to date, there is no appropriate biomarker for tobacco-related exposure because the proposed chemicals seem to be nonspecific or they are only appropriate for short-term exposure. Moreover, conventional sampling methodologies require an invasive method because blood or urine samples are required. The use of a microtrap system coupled to gas chromatography–mass spectrometry analysis has been found to be very effective for the noninvasive analysis of volatile organic compounds in breath samples. The levels of benzene, 2,5-dimethylfuran, toluene, o-xylene, and m- p-xylene have been analyzed in breath samples obtained from 204 volunteers (100 smokers, 104 nonsmokers; 147 females, 57 males; ages 16 to 53 years). 2,5-Dimethylfuran was always below the limit of detection (0.005 ppbv) in the nonsmoker population and always detected in smokers independently of the smoking habits. Benzene was only an effective biomarker for medium and heavy smokers, and its level was affected by smoking habits. Regarding the levels of xylenes and toluene, they were only different in heavy smokers and after short-term exposure. The results obtained suggest that 2,5-dimethylfuran is a specific breath biomarker of smoking status independently of the smoking habits (e.g., short- and long-term exposure, light and heavy consumption), and so this compound might be useful as a biomarker of smoking exposure