972 resultados para Visual C .net
Resumo:
We calculate net community production (NCP) during summer 2005-2006 and spring 2006 in the Ross Sea using multiple approaches to determine the magnitude and consistency of rates. Water column carbon and nutrient inventories and surface ocean O2/Ar data are compared to satellite-derived primary productivity (PP) estimates and 14C uptake experiments. In spring, NCP was related to stratification proximal to upper ocean fronts. In summer, the most intense C drawdown was in shallow mixed layers affected by ice melt; depth-integrated C drawdown, however, increased with mixing depth. Delta O2/Ar-based methods, relying on gas exchange reconstructions, underestimate NCP due to seasonal variations in surface Delta O2/Ar and NCP rates. Mixed layer Delta O2/Ar requires approximately 60 days to reach steady state, starting from early spring. Additionally, cold temperatures prolong the sensitivity of gas exchange reconstructions to past NCP variability. Complex vertical structure, in addition to the seasonal cycle, affects interpretations of surface-based observations, including those made from satellites. During both spring and summer, substantial fractions of NCP were below the mixed layer. Satellite-derived estimates tended to overestimate PP relative to 14C-based estimates, most severely in locations of stronger upper water column stratification. Biases notwithstanding, NCP-PP comparisons indicated that community respiration was of similar magnitude to NCP. We observed that a substantial portion of NCP remained as suspended particulate matter in the upper water column, demonstrating a lag between production and export. Resolving the dynamic physical processes that structure variance in NCP and its fate will enhance the understanding of the carbon cycling in highly productive Antarctic environments.
Resumo:
En este texto se utilizará el lenguaje de programación Visual Basic. NET. Dicho lenguaje es uno de los más populares en el mundo por su facilidad para diseñar aplicaciones cada vez más robustas; permite crear aplicaciones para Windows de una forma sencilla. La palabra visual hace referencia a la forma en que se van diseñando las aplicaciones, y al aspecto gráfico que toman los diferentes objetos en el momento de ejecutar las aplicaciones; la palabra NET hace referencia al medio donde se ejecutarán las aplicaciones diseñadas. La necesidad sentida en las universidades y politécnicos de contar con un lenguaje que permita de manera rápida poner en práctica los conceptos teóricos tratados en las clases de Fundamentos de Programación y Programación Orientada a Objetos (para estudiantes de IngenierÃa de Sistemas) ha motivado la redacción de este texto. Su propósito es acercar a estudiantes a una herramienta potente y fácil de utilizar en un tiempo reducido, con el fin de probar los algoritmos diseñados en clase y validarlos de acuerdo con los requerimientos impuestos. Se pretende con este texto servir de guÃa a los estudiantes de Fundamentos de Programación de la Universidad de MedellÃn y de otras universidades para que puedan poner en práctica los conceptos tratados en la clase teórica.
Resumo:
Resumen tomado del autor
Resumo:
.NET Compiler Platform è un compilatore per i linguaggi C# e Visual Basic realizzato da Microsoft. L’innovazione apportata da tale strumento è l’introduzione di API che permettono di accedere al compilatore; in particolare, è possibile accedere alle strutture dati utilizzate al suo interno, quali simboli o AST, e controllare e/o modificare il processo di compilazione. Una parte di questo progetto, chiamato anche progetto Roslyn, è focalizzata sull’introduzione dello scripting per il linguaggio C#. In questa trattazione si è interessati a sperimentare le possibilità offerte da tale strumento nel campo dell’esecuzione dinamica di frammenti di codice. Gli obiettivi imposti si collocano nell’ambito della re-ingegnerizzazione e dello sviluppo di software. Tali obiettivi sono la re-implementazione dei filtri di selezione contenuti nel framework Phoenix, utilizzando le API di Roslyn per migliorarne le prestazioni, e la progettazione di un componente che realizzi una console per lo scripting C# dotata della possibilità di riferire dinamicamente librerie. Le API di compilazione si rivelano essere non propriamente adatte all’esecuzione immediata di frammenti di codice, nonostante ciò, è possibile, appoggiandosi alla reflection, utilizzarle per giungere a questo risultato. Lo scripting, invece, si rivela uno strumento dalle grandi potenzialità nel suddetto ambito.
Resumo:
Tesis (Optometra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de Optometria, 2015
Resumo:
Tesis (Optómetra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de OptometrÃa, 2014
Resumo:
Tesis (Optómetra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de OptometrÃa, 2015
Resumo:
Tesis (Optometra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de Optometria, 2015
Resumo:
This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.
Resumo:
The identification of core competencies which are important for undertaking accurate visual screening by orthoptists is considered in this study. The aim was to construct and validate a questionnaire for orthoptists to assess visual screening competency. This study comprised three steps. The first step involved a 69-item self-assessment questionnaire constructed to assess orthoptists' perception of their competencies in visual screening programs for children. This questionnaire was constructed with statements from the Orthoptic Benchmark Statement for Health Care Programmes (Quality Assurance Agency for Higher Education, UK) and included three competency dimensions: interpersonal (IP), instrumental (IT) and systemic (ST). The second step involved questionnaire translation.
Resumo:
Introdução – Na avaliação diagnóstica em mamografia, o desempenho do radiologista pode estar sujeito a erros de diagnóstico. Objetivo – Descrever a importância da perceção visual na análise da mamografia, identificando os principais fatores que contribuem para a perceção visual do radiologista e que condicionam a acuidade diagnóstica. Metodologia – Estudo descritivo baseado numa revisão sistemática de literatura através da PubMed e da Science Direct. Foram incluÃdos 42 artigos que respeitavam, pelo menos, um dos critérios de inclusão no estudo. Para a seleção das referências foi utilizada a metodologia PRISMA, constituÃda por 4 fases: identificação, seleção preliminar, elegibilidade e estudos incluÃdos. Resultados – Na avaliação diagnóstica em mamografia, a perceção visual está intimamente relacionada com: 1) diferentes parâmetros visuais e da motilidade ocular (acuidade visual, sensibilidade ao contraste e à luminância e movimentos oculares); 2) com condições de visualização de uma imagem (iluminância da sala e luminância do monitor); e 3) fadiga ocular provocada pela observação diária consecutiva de imagens. Conclusões – A perceção visual pode ser influenciada por 3 categorias de erros observados: erros de pesquisa (lesões não são fixadas pela fóvea), erros de reconhecimento (lesões fixadas, mas não durante o tempo suficiente) e erros de decisão (lesões fixadas, mas não identificadas como suspeitas). Os estudos analisados sobre perceção visual, atenção visual e estratégia visual, bem como os estudos sobre condições de visualização não caracterizam a função visual dos observadores. Para uma avaliação correta da perceção visual em mamografia deverão ser efetuados estudos que correlacionem a função visual com a qualidade diagnóstica. ABSTRACT - Introduction – Diagnostic evaluation in mammography could be influenced by the radiologist performance that could be under diagnostic errors. Aims – To describe the importance of radiologist visual perception in mammographic diagnostic evaluation and to identify the main factors that contribute to diagnostic accuracy. Methods – In this systematic review 42 references were included based on inclusion criteria (PubMed and Science Direct). PRISMA method was used to select the references following 4 steps: identification, screening, eligibility and included references. Results – Visual perception in mammography diagnostic evaluation is related with: 1) visual parameters and ocular motility (visual acuity, contrast sensitivity and luminance and ocular movements); 2) image visualization environment (room iluminance and monitor luminance); and 3) eyestrain caused by image daily consecutive observation. Conclusions – Visual perception can be influenced by three errors categories: search errors (lesions are never looked at with high-resolution foveal vision), recognition errors (lesions are looked at, but not long enough to detect or recognize) and decision errors (lesions are looked at for long periods of time but are still missed). The reviewed studies concerning visual perception, visual attention, visual strategies and image visualization environment do not describe observer’s visual function. An accurate evaluation of visual perception in mammography must include visual function analysis.
Resumo:
RESUMO: Introdução – A insuficiência de convergência (IC) pode desencadear alterações da atenção visual. Pretende-se investigar se existem alterações na atenção visual em estudantes do ensino superior com IC. Metodologia – Estudo quantitativo, comparativo e correlacional. Participaram 44 estudantes com idades compreendidas entre os 18 e os 24 anos. Formaram-se dois grupos, um com Visão Binocular Normal (VBN) e outro com IC. O grupo com IC incluiu os indivÃduos que apresentaram alterações no ponto próximo de convergência (PPC) e/ou na convergência para perto (C’). Para avaliar a atenção visual utilizou-se o teste de cancelamento de sinos. Resultados – O grupo com VBN foi composto por 32 indivÃduos (23 do género feminino) e o grupo com IC por 12 indivÃduos (11 do género feminino). No teste de atenção visual verificou-se que o número médio de sinos identificados foi de 34,6 para o grupo com VBN e de 34,3 no grupo com IC. O tempo médio de realização do teste foi de 167,9s e de 198,3s para os grupos de VBN e IC, respetivamente. Observou-se uma correlação moderada positiva entre o PPC e o tempo médio de realização do teste (r≈0,63) e uma correlação fraca positiva entre o número médio de sinos identificados e a C’ (r≈0,16). Por outro lado, a correlação entre o PPC e o número médio de sinos identificados (r≈-0,48) foi fraca negativa e entre a C’ e o tempo médio (r≈-0,05) foi Ãnfima negativa. Discussão/Conclusões – O grupo com VBN apresenta um número médio de sinos identificados superior ao grupo com IC. Verifica-se ainda que o grupo com IC demorou mais tempo na realização do teste, comparativamente com o grupo com VBN. Estes resultados apontam para uma possÃvel relação entre a IC e a diminuição da atenção visual.
Resumo:
Esta dissertação aborda o problema de detecção e desvio de obstáculos "SAA- Sense And Avoid" em movimento para veÃculos aéreos. Em particular apresenta contribuições tendo em vista a obtenção de soluções para permitir a utilização de aeronaves não tripuladas em espaço aéreo não segregado e para aplicações civis. Estas contribuições caracterizam-se por: uma análise do problema de SAA em \UAV's - Unmmaned Aerial Vehicles\ civis; a definição do conceito e metodologia para o projecto deste tipo de sistemas; uma proposta de \ben- chmarking\ para o sistema SAA caracterizando um conjunto de "datasets\ adequados para a validação de métodos de detecção; respectiva validação experimental do processo e obtenção de "datasets"; a análise do estado da arte para a detecção de \Dim point features\ ; o projecto de uma arquitectura para uma solução de SAA incorporando a integração de compensação de \ego motion" e respectiva validação para um "dataset" recolhido. Tendo em vista a análise comparativa de diferentes métodos bem como a validação de soluções foi proposta a recolha de um conjunto de \datasets" de informação sensorial e de navegação. Para os mesmos foram definidos um conjunto de experiências e cenários experimentais. Foi projectado e implementado um setup experimental para a recolha dos \datasets" e realizadas experiências de recolha recorrendo a aeronaves tripuladas. O setup desenvolvido incorpora um sistema inercial de alta precisão, duas câmaras digitais sincronizadas (possibilitando análise de informa formação stereo) e um receptor GPS. As aeronaves alvo transportam um receptor GPS com logger incorporado permitindo a correlação espacial dos resultados de detecção. Com este sistema foram recolhidos dados referentes a cenários de aproximação com diferentes trajectórias e condições ambientais bem como incorporando movimento do dispositivo detector. O método proposto foi validado para os datasets recolhidos tendo-se verificado, numa análise preliminar, a detecção do obstáculo (avião ultraleve) em todas as frames para uma distância inferior a 3 km com taxas de sucesso na ordem dos 95% para distâncias entre os 3 e os 4 km. Os resultados apresentados permitem validar a arquitectura proposta para a solução do problema de SAA em veÃculos aéreos autónomos e abrem perspectivas muito promissoras para desenvolvimento futuro com forte impacto técnico-cientÃfico bem como sócio-economico. A incorporação de informa formação de \ego motion" permite fornecer um forte incremento em termos de desempenho.
Resumo:
Many studies have demonstrated the relationship between the alpha activity and the central visual ability, in which the visual ability is usually assessed through static stimuli. Besides static circumstance, however in the real environment there are often dynamic changes and the peripheral visual ability in a dynamic environment (i.e., dynamic peripheral visual ability) is important for all people. So far, no work has reported whether there is a relationship between the dynamic peripheral visual ability and the alpha activity. Thus, the objective of this study was to investigate their relationship. Sixty-two soccer players performed a newly designed peripheral vision task in which the visual stimuli were dynamic, while their EEG signals were recorded from Cz, O1, and O2 locations. The relationship between the dynamic peripheral visual performance and the alpha activity was examined by the percentage-bend correlation test. The results indicated no significant correlation between the dynamic peripheral visual performance and the alpha amplitudes in the eyes-open and eyes-closed resting condition. However, it was not the case for the alpha activity during the peripheral vision task: the dynamic peripheral visual performance showed significant positive inter-individual correlations with the amplitudes in the alpha band (8-12 Hz) and the individual alpha band (IAB) during the peripheral vision task. A potential application of this finding is to improve the dynamic peripheral visual performance by up-regulating alpha activity using neuromodulation techniques.
Resumo:
Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.