994 resultados para Vision Tests.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

As in many parrots, the plumage of the budgerigar Melopsittacus undulatus reflects near-ultraviolet (UVA) wavelengths (300-400 nm) and exhibits UVA-induced fluorescence. However, there have, to our knowledge, been no tests of whether the yellow fluorescence observed under intense UVA illumination has any role in signalling. Four experiments were carried out on wild-type budgerigars, where the presence and absence of UV reflectance and fluorescence were manipulated using filters. Few studies have attempted to separate the contribution of UV reflectance to plumage hue as opposed to brightness or distinguish between a role in sexual as opposed to social preferences. However, our first experiments show that not only do females consistently prefer UV-reflecting males, but also that the observed preferences are due to removal of UV affecting the perceived hue rather than brightness. Furthermore, we found no effect Of the light environment on male response to females, suggesting that the female preferences relate to plumage colour per se. Whilst UV reflectance appears important in heterosexual choice by, females, it has no detectable influence on same-sex association preferences. The results from the second series of experiments suggest that enhancement of the budgerigar's yellow coloration through fluorescence has no effect on male attractiveness. However, the fluorescent plumage may play a role in signalling by virtue of the fact that it absorbs UVA and so increases contrast with nearby UV-reflecting plumage. Our study provides convincing evidence that UV reflectances can play a role in mate choice in non-passerines, but no evidence that the yellow fluorescence observed under UVA illumination is itself important as a signal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of children's vision screenings is to detect visual problems that are common in this age category through valid and reliable tests. Nevertheless, the cost effectiveness of paediatric vision screenings, the nature of the tests included in the screening batteries and the ideal screening age has been the cause of much debate in Australia and worldwide. Therefore, the purpose of this review is to report on the current practice of children's vision screenings in Australia and other countries, as well as to evaluate the evidence for and against the provision of such screenings. This was undertaken through a detailed investigation of peer-reviewed publications on this topic. The current review demonstrates that there is no agreed vision screening protocol for children in Australia. This appears to be a result of the lack of strong evidence supporting the benefit of such screenings. While amblyopia, strabismus and, to a lesser extent refractive error, are targeted by many screening programs during pre-school and at school entry, there is less agreement regarding the value of screening for other visual conditions, such as binocular vision disorders, ocular health problems and refractive errors that are less likely to reduce distance visual acuity. In addition, in Australia, little agreement exists in the frequency and coverage of screening programs between states and territories and the screening programs that are offered are ad hoc and poorly documented. Australian children stand to benefit from improved cohesion and communication between jurisdictions and health professionals to enable an equitable provision of validated vision screening services that have the best chance of early detection and intervention for a range of paediatric visual problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We used psychophysical tests to evaluate spatial vision in 15 subjects with a clinical history of chronic alcoholism by measuring luminance contrast sensitivity and color discrimination. The subjects were initially subjected to clinical inquiry and ophthalmological exam. Subjects then performed psychophysical tests to measure spatial contrast thresholds using sine wave gratings of different spatial frequencies and contrasts and chromatic discrimination thresholds using the Mollon-Reffin test. For the analysis, subjects were divided into three groups according to age and compared with age-matched controls. Ten subjects had some degree of color vision loss, which was quite severe in seven cases. All subjects had normal luminance contrast sensitivity. The results suggest that color vision changes related to chronic alcoholism can occur in the absence of impairment of spatial luminance contrast sensitivity and thus is an important aspect to be considered in the clinical evaluation of this condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pacientes que fazem uso de cloroquina ou hidróxi-cloroquina, drogas que são freqüentemente administradas para o tratamento de artrite reumatóide, lúpus eritrematoso ou malária, podem sofrer alterações na visão de cores e na sensibilidade de contraste. O presente estudo avaliou a função visual destes pacientes em um estudo conjunto da Universidade de São Paulo (USP), em São Paulo, e da Universidade Federal do Pará (UFPA), em Belém. Trinta e dois pacientes usuários de cloroquina sem alterações no exame de fundo de olho foram avaliados em São Paulo (n=10, 38 a 71 anos, média=55,8 anos) e em Belém (n=22, 20 a 67 anos, média=40 anos). A dose acumulada de cloroquina prescrita foi de 45 a 430 g (média=213 g; dp=152 g) para o grupo de São Paulo, e de 36 a 540 g (média=174 g; dp=183 g) para o grupo de Belém. Os testes foram realizados monocularmente com o estado refracional corrigido. A discriminação de cor foi avaliada utilizando o Teste de Cor de Cambridge (CCT): o limiar de discriminação de cor foi mensurado primeiro nos eixos protano, deutano e tritano, e em seqüência, três elipses de MacAdam foram determinadas. A visão de cores dos pacientes também foi avaliada com testes de arranjo de cores: o teste de 100 matizes de Farnsworth-Munsell (FM100), o D15 de Farnsworth-Munsell, e o teste Lanthony Dessaturado (D15d). A sensibilidade de contraste foi também medida com grades senoidais preto-e-brancas em 22 pacientes. Os resultados foram comparados com controles sem patologias oftalmológicasou neuro-oftalomológicas. 24 pacientes apresentaram discromatopsia adquirida, com perdas seletivas (11 pessoas) ou difusas (13 pessoas). Embora as perdas estivessem presentes no FM100, não houve correlação entre o escore de erro do FM100 e a área elíptica medida pelo CCT. Além disso, três pacientes que tiveram escores normais no FM100 falharam para alcançar limiares normais no CCT. O teste de Lanthony foi menos sensível do que os outros dois testes, tal que falhou em indicar perda em cerca de metade dos pacientes afetados, e o D15 foi o teste menos sensível, deixando de indicar déficits em 9 de 10 pacientes. A sensibilidade de contraste esteve dentro dos valores normais para pacientes submetidos a este teste. A extensão das perdas na discriminação de cores foi positivamente correlacionada com a dose acumulada. O CCT é recomendado para o acompanhamento destes pacientes, pois forneceu dados quantitativos que podem ser diretamente interpretados no espaço cromático da CIE (Commission Internationelle d'Éclairage).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Color vision impairment emerges at early stages of diabetes mellitus type 2 (DM2) and may precede diabetic retinopathy or the appearance of vascular alterations in the retina. The aim of the present study was to compare the evaluation of the color vision with two different tests - the Lanthony desaturated D-15d test (a traditional color arrangement test), and the Cambridge Colour Test (CCT) (a computerized color discrimination test) - in patients diagnosed with DM2 without clinical signs of diabetic retinopathy (DR), and in sex- and age-matched control groups. Both color tests revealed statistically significant differences between the controls and the worst eyes of the DM2 patients. In addition, the degree of color vision impairment diagnosed by both tests correlated with the disease duration. The D-15d outcomes indicated solely tritan losses. In comparison, CCT outcomes revealed diffuse losses in color discrimination: 13.3% for best eyes and 29% for worst eyes. In addition, elevation of tritan thresholds in the DM2 patients, as detected by the Trivector subtest of the CCT, was found to correlate with the level of glycated hemoglobin. Outcomes of both tests confirm that subclinical losses of color vision are present in DM2 patients at an early stage of the disease, prior to signs of retinopathy. Considering the advantages of the CCT test compared to the D-15d test, further studies should attempt to verify and/or improve the efficiency of the CCT test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This longitudinal study addresses the reversibility of color vision losses in subjects who had been occupationally exposed to mercury vapor. Color discrimination was assessed in 20 Hg-exposed patients (mean age = 42.4 +/- 6.5 years; 6 females and 14 males) with exposure to Hg vapor during 10.5 +/- 5.3 years and away from the work place (relative to 2002) for 6.8 +/- 4.2 years. During the Hg exposure or up to one year after ceasing it, mean urinary Hg concentration was 47 +/- 35.4 mu g/g creatinine. There was no information on Hg urinary concentration at the time of the first tests, in 2002 (Ventura et al., 2005), but at the time of the follow-up tests, in 2005, this value was 1.4 +/- 1.4 mu g/g creatinine for patients compared with 0.5 +/- 0.5 mu g/g creatinine for controls (different group from the one in Ventura et al. (2005)). Color vision was monocularly assessed using the Cambridge Colour Test (CCT). Hg-exposed patients had significantly worse color discrimination (p < 0.02) than controls, as evaluated by the size of MacAdam`s color discrimination ellipses and color discrimination thresholds along protan, deutan, and tritan confusion axes. There were no significant differences between the results of the study in Ventura et al. (2005) and in the present follow-up measurements, in 2005, except for worsening of the tritan thresholds in the best eye in 2005. Both chromatic systems, blue-yellow and red-green, were affected in the first evaluation (Ventura et al., 2005) and remained impaired in the follow-up testing, in 2005. These findings indicate that following a long-term occupational exposure to Hg vapor, even several years away from the source of intoxication, color vision impairment remains irreversible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This study measured grating visual acuity in 173 children between 6-48 months of age who had different types of spastic cerebral palsy (CP). Method: Behavioural acuity was measured with the Teller Acuity Cards (TAC) using a staircase psychophysical procedure. Electrophysiological visual acuity was estimated using the sweep VEP (sVEP). Results: The percentage of children outside the superior tolerance limits was 44 of 63 (69%) and 50 of 55 (91%) of tetraplegic, 36 of 56 (64%) and 42 of 53 (79%) of diplegic, 10 of 48 (21%) and 12 of 40 (30%) of hemiplegic for sVEP and TAC, respectively. For the sVEP, the greater visual acuity deficit found in the tetraplegic group was significantly different from that of the hemiplegic group (p < 0.001). In the TAC procedure the mean visual acuity deficits of the tetraplegic and diplegic groups were significantly different from that of hemiplegic group (p < 0.001). The differences between sVEP and TAC means of visual acuity difference were statistically significant for the tetraplegic (p < 0.001), diplegic (p < 0.001), and hemiplegic group (p = 0.004). Discussion: Better visual acuities were obtained in both procedures for hemiplegic children compared to diplegic or tetraplegic. Tetraplegic and diplegic children showed greater discrepancies between the TAC and sVEP results. Inter-ocular acuity difference was more frequent in sVEP measurements. Conclusions: Electrophysiologically measured visual acuity is better than behavioural visual acuity in children with CP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thesis work concerns X-ray spectrometry for both medical and space applications and is divided into two sections. The first section addresses an X-ray spectrometric system designed to study radiological beams and is devoted to the optimization of diagnostic procedures in medicine. A parametric semi-empirical model capable of efficiently reconstructing diagnostic X-ray spectra in 'middle power' computers was developed and tested. In addition, different silicon diode detectors were tested as real-time detectors in order to provide a real-time evaluation of the spectrum during diagnostic procedures. This project contributes to the field by presenting an improved simulation of a realistic X-ray beam emerging from a common X-ray tube with a complete and detailed spectrum that lends itself to further studies of added filtration, thus providing an optimized beam for different diagnostic applications in medicine. The second section describes the preliminary tests that have been carried out on the first version of an Application Specific Integrated Circuit (ASIC), integrated with large area position-sensitive Silicon Drift Detector (SDD) to be used on board future space missions. This technology has been developed for the ESA project: LOFT (Large Observatory for X-ray Timing), a new medium-class space mission that the European Space Agency has been assessing since February of 2011. The LOFT project was proposed as part of the Cosmic Vision Program (2015-2025).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM To report on an intraradicular visual test in a simulated clinical setting under different optical conditions. METHODOLOGY Miniaturized visual tests with E-optotypes (bar distance from 0.01 to 0.05 mm) were fixed inside the root canal system of an extracted maxillary molar at different locations: at the orifice, a depth of 5 mm and the apex. The tooth was mounted in a phantom head for a simulated clinical setting. Unaided vision was compared with Galilean loupes (2.5× magnification) with integrated light source and an operating microscope (6× magnification). The influence of the dentists' age within two groups was evaluated: <40 years (n = 9) and ≥40 years (n = 15). RESULTS Some younger dentists were able to identify the E-optotypes at the orifice, but otherwise, natural vision did not reveal any measurable result. With Galilean loupes, the younger dentists <40 years could see a 0.05 mm structure at the root canal orifice, in contrast to the older group ≥40 years. Only the microscope allowed the observation of structures inside the root canal, independent of age. CONCLUSION Unaided vision and Galilean loupes with an integrated light source could not provide any measurable vision inside the root canal, but younger dentists <40 years could detect with Galilean loupes a canal orifice corresponding to the tip of the smallest endodontic instruments. Dentists over 40 years of age were dependent on the microscope to inspect the root canal system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Although it seems plausible that sports performance relies on high-acuity foveal vision, it could be empirically shown that myoptic blur (up to +2 diopters) does not harm performance in sport tasks that require foveal information pick-up like golf putting (Bulson, Ciuffreda, & Hung, 2008). How myoptic blur affects peripheral performance is yet unknown. Attention might be less needed for processing visual cues foveally and lead to better performance because peripheral cues are better processed as a function of reduced foveal vision, which will be tested in the current experiment. Methods: 18 sport science students with self-reported myopia volunteered as participants, all of them regularly wearing contact lenses. Exclusion criteria comprised visual correction other than myopic, correction of astigmatism and use of contact lenses out of Swiss delivery area. For each of the participants, three pairs of additional contact lenses (besides their regular lenses; used in the “plano” condition) were manufactured with an individual overcorrection to a retinal defocus of +1 to +3 diopters (referred to as “+1.00 D”, “+2.00 D”, and “+3.00 D” condition, respectively). Gaze data were acquired while participants had to perform a multiple object tracking (MOT) task that required to track 4 out of 10 moving stimuli. In addition, in 66.7 % of all trials, one of the 4 targets suddenly stopped during the motion phase for a period of 0.5 s. Stimuli moved in front of a picture of a sports hall to allow for foveal processing. Due to the directional hypotheses, the level of significance for one-tailed tests on differences was set at α = .05 and posteriori effect sizes were computed as partial eta squares (ηρ2). Results: Due to problems with the gaze-data collection, 3 participants had to be excluded from further analyses. The expectation of a centroid strategy was confirmed because gaze was closer to the centroid than the target (all p < .01). In comparison to the plano baseline, participants more often recalled all 4 targets under defocus conditions, F(1,14) = 26.13, p < .01, ηρ2 = .65. The three defocus conditions differed significantly, F(2,28) = 2.56, p = .05, ηρ2 = .16, with a higher accuracy as a function of a defocus increase and significant contrasts between conditions +1.00 D and +2.00 D (p = .03) and +1.00 D and +3.00 D (p = .03). For stop trials, significant differences could neither be found between plano baseline and defocus conditions, F(1,14) = .19, p = .67, ηρ2 = .01, nor between the three defocus conditions, F(2,28) = 1.09, p = .18, ηρ2 = .07. Participants reacted faster in “4 correct+button” trials under defocus than under plano-baseline conditions, F(1,14) = 10.77, p < .01, ηρ2 = .44. The defocus conditions differed significantly, F(2,28) = 6.16, p < .01, ηρ2 = .31, with shorter response times as a function of a defocus increase and significant contrasts between +1.00 D and +2.00 D (p = .01) and +1.00 D and +3.00 D (p < .01). Discussion: The results show that gaze behaviour in MOT is not affected to a relevant degree by a visual overcorrection up to +3 diopters. Hence, it can be taken for granted that peripheral event detection was investigated in the present study. This overcorrection, however, does not harm the capability to peripherally track objects. Moreover, if an event has to be detected peripherally, neither response accuracy nor response time is negatively affected. Findings could claim considerable relevance for all sport situations in which peripheral vision is required which now needs applied studies on this topic. References: Bulson, R. C., Ciuffreda, K. J., & Hung, G. K. (2008). The effect of retinal defocus on golf putting. Ophthalmic and Physiological Optics, 28, 334-344.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we apply a hierarchical tracking strategy of planar objects (or that can be assumed to be planar) that is based on direct methods for vision-based applications on-board UAVs. The use of this tracking strategy allows to achieve the tasks at real-time frame rates and to overcome problems posed by the challenging conditions of the tasks: e.g. constant vibrations, fast 3D changes, or limited capacity on-board. The vast majority of approaches make use of feature-based methods to track objects. Nonetheless, in this paper we show that although some of these feature-based solutions are faster, direct methods can be more robust under fast 3D motions (fast changes in position), some changes in appearance, constant vibrations (without requiring any specific hardware or software for video stabilization), and situations in which part of the object to track is outside of the field of view of the camera. The performance of the proposed tracking strategy on-board UAVs is evaluated with images from realflight tests using manually-generated ground truth information, accurate position estimation using a Vicon system, and also with simulated data from a simulation environment. Results show that the hierarchical tracking strategy performs better than wellknown feature-based algorithms and well-known configurations of direct methods, and that its performance is robust enough for vision-in-the-loop tasks, e.g. for vision-based landing tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The OMNIWORKS project objective is to develop an autonomous and modular aerial inspection system for an off-shore meteorological mast up to 90m in length. The UAV was equipped with an omni-directional camera and vertical take-off/landing capabilities that should be simple enough to operate as to not need the interventions of a professional pilot under challenging situations. Therefore the tests included different aspects used to evaluate both the technical performance of the UAV behavior as well as the operators? point of view.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El principal objetivo de este trabajo es proporcionar una solución en tiempo real basada en visión estéreo o monocular precisa y robusta para que un vehículo aéreo no tripulado (UAV) sea autónomo en varios tipos de aplicaciones UAV, especialmente en entornos abarrotados sin señal GPS. Este trabajo principalmente consiste en tres temas de investigación de UAV basados en técnicas de visión por computador: (I) visual tracking, proporciona soluciones efectivas para localizar visualmente objetos de interés estáticos o en movimiento durante el tiempo que dura el vuelo del UAV mediante una aproximación adaptativa online y una estrategia de múltiple resolución, de este modo superamos los problemas generados por las diferentes situaciones desafiantes, tales como cambios significativos de aspecto, iluminación del entorno variante, fondo del tracking embarullado, oclusión parcial o total de objetos, variaciones rápidas de posición y vibraciones mecánicas a bordo. La solución ha sido utilizada en aterrizajes autónomos, inspección de plataformas mar adentro o tracking de aviones en pleno vuelo para su detección y evasión; (II) odometría visual: proporciona una solución eficiente al UAV para estimar la posición con 6 grados de libertad (6D) usando únicamente la entrada de una cámara estéreo a bordo del UAV. Un método Semi-Global Blocking Matching (SGBM) eficiente basado en una estrategia grueso-a-fino ha sido implementada para una rápida y profunda estimación del plano. Además, la solución toma provecho eficazmente de la información 2D y 3D para estimar la posición 6D, resolviendo de esta manera la limitación de un punto de referencia fijo en la cámara estéreo. Una robusta aproximación volumétrica de mapping basada en el framework Octomap ha sido utilizada para reconstruir entornos cerrados y al aire libre bastante abarrotados en 3D con memoria y errores correlacionados espacialmente o temporalmente; (III) visual control, ofrece soluciones de control prácticas para la navegación de un UAV usando Fuzzy Logic Controller (FLC) con la estimación visual. Y el framework de Cross-Entropy Optimization (CEO) ha sido usado para optimizar el factor de escala y la función de pertenencia en FLC. Todas las soluciones basadas en visión en este trabajo han sido probadas en test reales. Y los conjuntos de datos de imágenes reales grabados en estos test o disponibles para la comunidad pública han sido utilizados para evaluar el rendimiento de estas soluciones basadas en visión con ground truth. Además, las soluciones de visión presentadas han sido comparadas con algoritmos de visión del estado del arte. Los test reales y los resultados de evaluación muestran que las soluciones basadas en visión proporcionadas han obtenido rendimientos en tiempo real precisos y robustos, o han alcanzado un mejor rendimiento que aquellos algoritmos del estado del arte. La estimación basada en visión ha ganado un rol muy importante en controlar un UAV típico para alcanzar autonomía en aplicaciones UAV. ABSTRACT The main objective of this dissertation is providing real-time accurate robust monocular or stereo vision-based solution for Unmanned Aerial Vehicle (UAV) to achieve the autonomy in various types of UAV applications, especially in GPS-denied dynamic cluttered environments. This dissertation mainly consists of three UAV research topics based on computer vision technique: (I) visual tracking, it supplys effective solutions to visually locate interesting static or moving object over time during UAV flight with on-line adaptivity approach and multiple-resolution strategy, thereby overcoming the problems generated by the different challenging situations, such as significant appearance change, variant surrounding illumination, cluttered tracking background, partial or full object occlusion, rapid pose variation and onboard mechanical vibration. The solutions have been utilized in autonomous landing, offshore floating platform inspection and midair aircraft tracking for sense-and-avoid; (II) visual odometry: it provides the efficient solution for UAV to estimate the 6 Degree-of-freedom (6D) pose using only the input of stereo camera onboard UAV. An efficient Semi-Global Blocking Matching (SGBM) method based on a coarse-to-fine strategy has been implemented for fast depth map estimation. In addition, the solution effectively takes advantage of both 2D and 3D information to estimate the 6D pose, thereby solving the limitation of a fixed small baseline in the stereo camera. A robust volumetric occupancy mapping approach based on the Octomap framework has been utilized to reconstruct indoor and outdoor large-scale cluttered environments in 3D with less temporally or spatially correlated measurement errors and memory; (III) visual control, it offers practical control solutions to navigate UAV using Fuzzy Logic Controller (FLC) with the visual estimation. And the Cross-Entropy Optimization (CEO) framework has been used to optimize the scaling factor and the membership function in FLC. All the vision-based solutions in this dissertation have been tested in real tests. And the real image datasets recorded from these tests or available from public community have been utilized to evaluate the performance of these vision-based solutions with ground truth. Additionally, the presented vision solutions have compared with the state-of-art visual algorithms. Real tests and evaluation results show that the provided vision-based solutions have obtained real-time accurate robust performances, or gained better performance than those state-of-art visual algorithms. The vision-based estimation has played a critically important role for controlling a typical UAV to achieve autonomy in the UAV application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blindsight is the rare and paradoxical ability of some human subjects with occipital lobe brain damage to discriminate unseen stimuli in their clinically blind field defects when forced-choice procedures are used, implying that lesions of striate cortex produce a sharp dissociation between visual performance and visual awareness. Skeptics have argued that this is no different from the behavior of normal subjects at the lower limits of conscious vision, at which such dissociations could arise trivially by using different response criteria during clinical and forced-choice tests. We tested this claim explicitly by measuring the sensitivity of a hemianopic patient independently of his response criterion in yes-no and forced-choice detection tasks with the same stimulus and found that, unlike normal controls, his sensitivity was significantly higher during the forced-choice task. Thus, the dissociation by which blindsight is defined is not simply due to a difference in the patients’ response bias between the two paradigms. This result implies that blindsight is unlike normal, near-threshold vision and that information about the stimulus is processed in blindsighted patients in an unusual way.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le traumatisme craniocérébral léger (TCCL) a des effets complexes sur plusieurs fonctions cérébrales, dont l’évaluation et le suivi peuvent être difficiles. Les problèmes visuels et les troubles de l’équilibre font partie des plaintes fréquemment rencontrées après un TCCL. En outre, ces problèmes peuvent continuer à affecter les personnes ayant eu un TCCL longtemps après la phase aiguë du traumatisme. Cependant, les évaluations cliniques conventionnelles de la vision et de l’équilibre ne permettent pas, la plupart du temps, d’objectiver ces symptômes, surtout lorsqu’ils s’installent durablement. De plus, il n’existe pas, à notre connaissance, d’étude longitudinale ayant étudié les déficits visuels perceptifs, en tant que tels, ni les troubles de l’équilibre secondaires à un TCCL, chez l’adulte. L’objectif de ce projet était donc de déterminer la nature et la durée des effets d’un tel traumatisme sur la perception visuelle et sur la stabilité posturale, en évaluant des adultes TCCL et contrôles sur une période d’un an. Les mêmes sujets, exactement, ont participé aux deux expériences, qui ont été menées les mêmes jours pour chacun des sujets. L’impact du TCCL sur la perception visuelle de réseaux sinusoïdaux définis par des attributs de premier et de second ordre a d’abord été étudié. Quinze adultes diagnostiqués TCCL ont été évalués 15 jours, 3 mois et 12 mois après leur traumatisme. Quinze adultes contrôles appariés ont été évalués à des périodes identiques. Des temps de réaction (TR) de détection de clignotement et de discrimination de direction de mouvement ont été mesurés. Les niveaux de contraste des stimuli de premier et de second ordre ont été ajustés pour qu’ils aient une visibilité comparable, et les moyennes, médianes, écarts-types (ET) et écarts interquartiles (EIQ) des TR correspondant aux bonnes réponses ont été calculés. Le niveau de symptômes a également été évalué pour le comparer aux données de TR. De façon générale, les TR des TCCL étaient plus longs et plus variables (plus grands ET et EIQ) que ceux des contrôles. De plus, les TR des TCCL étaient plus courts pour les stimuli de premier ordre que pour ceux de second ordre, et plus variables pour les stimuli de premier ordre que pour ceux de second ordre, dans la condition de discrimination de mouvement. Ces observations se sont répétées au cours des trois sessions. Le niveau de symptômes des TCCL était supérieur à celui des participants contrôles, et malgré une amélioration, cet écart est resté significatif sur la période d’un an qui a suivi le traumatisme. La seconde expérience, elle, était destinée à évaluer l’impact du TCCL sur le contrôle postural. Pour cela, nous avons mesuré l’amplitude d’oscillation posturale dans l’axe antéropostérieur et l’instabilité posturale (au moyen de la vitesse quadratique moyenne (VQM) des oscillations posturales) en position debout, les pieds joints, sur une surface ferme, dans cinq conditions différentes : les yeux fermés, et dans un tunnel virtuel tridimensionnel soit statique, soit oscillant de façon sinusoïdale dans la direction antéropostérieure à trois vitesses différentes. Des mesures d’équilibre dérivées de tests cliniques, le Bruininks-Oseretsky Test of Motor Proficiency 2nd edition (BOT-2) et le Balance Error Scoring System (BESS) ont également été utilisées. Les participants diagnostiqués TCCL présentaient une plus grande instabilité posturale (une plus grande VQM des oscillations posturales) que les participants contrôles 2 semaines et 3 mois après le traumatisme, toutes conditions confondues. Ces troubles de l’équilibre secondaires au TCCL n’étaient plus présents un an après le traumatisme. Ces résultats suggèrent également que les déficits affectant les processus d’intégration visuelle mis en évidence dans la première expérience ont pu contribuer aux troubles de l’équilibre secondaires au TCCL. L’amplitude d’oscillation posturale dans l’axe antéropostérieur de même que les mesures dérivées des tests cliniques d’évaluation de l’équilibre (BOT-2 et BESS) ne se sont pas révélées être des mesures sensibles pour quantifier le déficit postural chez les sujets TCCL. L’association des mesures de TR à la perception des propriétés spécifiques des stimuli s’est révélée être à la fois une méthode de mesure particulièrement sensible aux anomalies visuomotrices secondaires à un TCCL, et un outil précis d’investigation des mécanismes sous-jacents à ces anomalies qui surviennent lorsque le cerveau est exposé à un traumatisme léger. De la même façon, les mesures d’instabilité posturale se sont révélées suffisamment sensibles pour permettre de mesurer les troubles de l’équilibre secondaires à un TCCL. Ainsi, le développement de tests de dépistage basés sur ces résultats et destinés à l’évaluation du TCCL dès ses premières étapes apparaît particulièrement intéressant. Il semble également primordial d’examiner les relations entre de tels déficits et la réalisation d’activités de la vie quotidienne, telles que les activités scolaires, professionnelles ou sportives, pour déterminer les impacts fonctionnels que peuvent avoir ces troubles des fonctions visuomotrice et du contrôle de l’équilibre.