984 resultados para VENTILATION: mechanically controlled
Resumo:
BACKGROUND: Open lung biopsy (OLB) is helpful in the management of patients with acute respiratory distress syndrome (ARDS) of unknown etiology. We determine the impact of surgical lung biopsies performed at the bedside on the management of patients with ARDS. METHODS: We reviewed all consecutive cases of patients with ARDS who underwent a surgical OLB at the bedside in a medical intensive care unit between 1993 and 2005. RESULTS: Biopsies were performed in 19 patients mechanically ventilated for ARDS of unknown etiology despite extensive diagnostic process and empirical therapeutic trials. Among them, 17 (89%) were immunocompromised and 10 patients experienced hematological malignancies. Surgical biopsies were obtained after a median (25%-75%) mechanical ventilation of 5 (2-11) days; mean (+/-SD) Pao(2)/Fio(2) ratio was 119.3 (+/-34.2) mm Hg. Histologic diagnoses were obtained in all cases and were specific in 13 patients (68%), including 9 (47%) not previously suspected. Immediate complications (26%) were local (pneumothorax, minimal bleeding) without general or respiratory consequences. The biopsy resulted in major changes in management in 17 patients (89%). It contributed to a decision to limit care in 12 of 17 patients who died. CONCLUSION: Our data confirm that surgical OLB may have an important impact on the management of patients with ARDS of unknown etiology after extensive diagnostic process. The procedure can be performed at the bedside, is safe, and has a high diagnostic yield leading to major changes in management, including withdrawal of vital support, in the majority of patients.
Resumo:
BACKGROUND: Pioglitazone, an oral anti-diabetic that stimulates the PPAR-gamma transcription factor, increased survival of mice with amyotrophic lateral sclerosis (ALS). METHODS/PRINCIPAL FINDINGS: We performed a phase II, double blind, multicentre, placebo controlled trial of pioglitazone in ALS patients under riluzole. 219 patients were randomly assigned to receive 45 mg/day of pioglitazone or placebo (one: one allocation ratio). The primary endpoint was survival. Secondary endpoints included incidence of non-invasive ventilation and tracheotomy, and slopes of ALS-FRS, slow vital capacity, and quality of life as assessed using EUROQoL EQ-5D. The study was conducted under a two-stage group sequential test, allowing to stop for futility or superiority after interim analysis. Shortly after interim analysis, 30 patients under pioglitazone and 24 patients under placebo had died. The trial was stopped for futility; the hazard ratio for primary endpoint was 1.21 (95% CI: 0.71-2.07, p = 0.48). Secondary endpoints were not modified by pioglitazone treatment. Pioglitazone was well tolerated. CONCLUSION/SIGNIFICANCE: Pioglitazone has no beneficial effects on the survival of ALS patients as add-on therapy to riluzole. TRIAL REGISTRATION: Clinicaltrials.gov NCT00690118.
Resumo:
STUDY OBJECTIVE: To evaluate the safety of a combined heat and moisture exchanger filter (HMEF) for the conditioning of inspired gas in long-term mechanical ventilation (MV). DESIGN: Randomized controlled trial. SETTING: Medical ICU in a large teaching hospital. PATIENTS: One hundred fifteen consecutive patients who required > or = 48 h of MV. INTERVENTIONS: Patients were randomized at intubation time (day 1) to receive inspired gas conditioned either by a water-bath humidifier heated at 32 degrees C (HWBH) or by an HMEF (Hygroster; DAR; Mirandola, Italy). MEASUREMENTS AND MAIN RESULTS: The two study groups were comparable in terms of primary pathologic condition at the time of hospital admission, disease severity as measured by the Simplified Acute Physiology Score, and ICU mortality. They did not differ with respect to ventilator days per patient (mean +/- SD: HMEF, 7.6 +/- 6.5; HWBH, 7.8 +/- 5.8), incidence of endotracheal tube obstruction (HMEF, 0/59; HWBH, 1/56), and incidence of hypothermic episodes (HMEF, five; HWBH, two). In 41 patients receiving MV for > or = 5 days, the morphologic integrity of respiratory epithelium was evaluated on day 1 and day 5, using a cytologic examination of tracheal aspirate smears. The state of ciliated epithelium was scored on a scale from 0 (poorest integrity) to 1,200 (maximum integrity), according to a well-described method. In both patient groups, the scores slightly but significantly decreased from day 1 to day 5 (mean +/- SD: HWBH, from 787 +/- 104 to 745 +/- 88; HMEF, from 813 +/- 79 to 739 +/- 62; p < 0.01 for both groups); there were no statistically significant differences between groups. CONCLUSIONS: These data indicate acceptable safety of HMEFs of the type used in the present study for long-term mechanical ventilation.
Resumo:
The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
OBJECTIVES: Resuscitation in severe head injury may be detrimental when given with hypotonic fluids. We evaluated the effects of lactated Ringer's solution (sodium 131 mmol/L, 277 mOsm/L) compared with hypertonic saline (sodium 268 mmol/L, 598 mOsm/L) in severely head-injured children over the first 3 days after injury. DESIGN: An open, randomized, and prospective study. SETTING: A 16-bed pediatric intensive care unit (ICU) (level III) at a university children's hospital. PATIENTS: A total of 35 consecutive children with head injury. INTERVENTIONS: Thirty-two children with Glasgow Coma Scores of <8 were randomly assigned to receive either lactated Ringer's solution (group 1) or hypertonic saline (group 2). Routine care was standardized, and included the following: head positioning at 30 degrees; normothermia (96.8 degrees to 98.6 degrees F [36 degrees to 37 degrees C]); analgesia and sedation with morphine (10 to 30 microg/kg/hr), midazolam (0.2 to 0.3 mg/kg/hr), and phenobarbital; volume-controlled ventilation (PaCO2 of 26.3 to 30 torr [3.5 to 4 kPa]); and optimal oxygenation (PaO2 of 90 to 105 torr [12 to 14 kPa], oxygen saturation of >92%, and hematocrit of >0.30). MEASUREMENTS AND MAIN RESULTS: Mean arterial pressure and intracranial pressure (ICP) were monitored continuously and documented hourly and at every intervention. The means of every 4-hr period were calculated and serum sodium concentrations were measured at the same time. An ICP of 15 mm Hg was treated with a predefined sequence of interventions, and complications were documented. There was no difference with respect to age, male/female ratio, or initial Glasgow Coma Score. In both groups, there was an inverse correlation between serum sodium concentration and ICP (group 1: r = -.13, r2 = .02, p < .03; group 2: r = -.29, r2 = .08, p < .001) that disappeared in group 1 and increased in group 2 (group 1: r = -.08, r2 = .01, NS; group 2: r = -.35, r2 =.12, p < .001). Correlation between serum sodium concentration and cerebral perfusion pressure (CPP) became significant in group 2 after 8 hrs of treatment (r = .2, r2 = .04, p = .002). Over time, ICP and CPP did not significantly differ between the groups. However, to keep ICP at <15 mm Hg, group 2 patients required significantly fewer interventions (p < .02). Group 1 patients received less sodium (8.0 +/- 4.5 vs. 11.5 +/- 5.0 mmol/kg/day, p = .05) and more fluid on day 1 (2850 +/- 1480 vs. 2180 +/- 770 mL/m2, p = .05). They also had a higher frequency of acute respiratory distress syndrome (four vs. 0 patients, p = .1) and more than two complications (six vs. 1 patient, p = .09). Group 2 patients had significantly shorter ICU stay times (11.6 +/- 6.1 vs. 8.0 +/- 2.4 days; p = .04) and shorter mechanical ventilation times (9.5 +/- 6.0 vs. 6.9 +/- 2.2 days; p = .1). The survival rate and duration of hospital stay were similar in both groups. CONCLUSIONS: Treatment of severe head injury with hypertonic saline is superior to that treatment with lactated Ringer's solution. An increase in serum sodium concentrations significantly correlates with lower ICP and higher CPP. Children treated with hypertonic saline require fewer interventions, have fewer complications, and stay a shorter time in the ICU.
Resumo:
Over the past decade, various implantable devices have been developed to treat diseases that were previously difficult to manage such diabetes, chronic pain, and neurodegenerative disorders. However, translation of these novel technologies into clinical practice is often difficult because fibrotic encapsulation and/or rejection impairs device function after body implantation. Ideally, cells of the host tissue should perceive the surface of the implant being similar to the normal extracellular matrix. Here, we developed an innovative approach to provide implant surfaces with adhesive protein micropatterns. The patterns were designed to promote adhesion of fibroblasts and macrophages by simultaneously suppressing fibrogenic activation of both cell types. In a rat model, subcutaneously implanted silicone pads provided with the novel micropatterns caused 6-fold lower formation of inflammatory giant cells compared with clinical grade, uncoated, or collagen-coated silicone implants. We further show that micropatterning of implants resulted in 2-3-fold reduced numbers of pro-fibrotic myofibroblast by inhibiting their mechanical activation. Our novel approach allows controlled cell attachment to implant surfaces, representing a critical advance for enhanced biointegration of implantable medical devices.
Resumo:
Introduction The benefit of corticosteroids as adjunctive treatment in patients with severe community-acquired pneumonia (CAP) requiring hospital admission remains unclear. This study aimed to evaluate the impact of corticosteroid treatment on outcomes in patients with CAP. Methods This was a prospective, double-blind and randomized study. All patients received treatment with ceftriaxone plus levofloxacin and methyl-prednisolone (MPDN) administered randomly and blindly as an initial bolus, followed by a tapering regimen, or placebo. Results Of the 56 patients included in the study, 28 (50%) were treated with concomitant corticosteroids. Patients included in the MPDN group show a more favourable evolution of the pO2/FiO2 ratio and faster decrease of fever, as well as greater radiological improvement at seven days. The time to resolution of morbidity was also significantly shorter in this group. Six patients met the criteria for mechanical ventilation (MV): five in the placebo group (22.7%) and one in the MPDN group (4.3%). The duration of MV was 13 days (interquartile range 7 to 26 days) for the placebo group and three days for the only case in the MPDN group. The differences did not reach statistical significance. Interleukin (IL)-6 and C-reactive protein (CRP) showed a significantly quicker decrease after 24 h of treatment among patients treated with MPDN. No differences in mortality were found among groups. Conclusions MPDN treatment, in combination with antibiotics, improves respiratory failure and accelerates the timing of clinical resolution of severe CAP needing hospital admission.
Resumo:
The aim of this study was to assess the efficacy of S-metolachlor applied in pre-emergence conditions for the control of Brachiaria decumbens, Digitaria horizontalis, and Panicum maximum in sugar cane mechanically harvested without previous burning of the crop (green harvest) with the crop residue either left or not on the soil surface. The experiments were established in the field according to a randomized complete block design with four repetitions in a 7 x 2 split-plot scheme. In the plots, five herbicide treatments were studied (S-metolachlor at 1.44, 1.92, and 2.40 kg ha-1, clomazone at 1.20 kg ha-1, and isoxaflutole at 0.188 kg ha-1), and two control treatments with no herbicide application. In the subplots, the presence or absence of sugar cane crop residue on the soil surface was evaluated. S-metolachlor efficacy was not hampered by either 14 or 20 t ha-1 of sugar cane crop residue on the soil surface. When sugar cane crop residue was covering the soil surface, S-metolachlor at a rate of 1.44 kg ha-1 resulted in weed control similar at their larger rates, where as without the presence of crop residue, S-metolachlor controlled B. decumbens, D. horizontalis, and P. maximum at the rates of 1.92, 1.44, and 1.92 kg ha-1, respectively. The herbicides clomazone and isoxaflutole were effective for the studied species, independently of the crop residue covering the soil surface. S-metolachlor caused no visible injury symptoms to the sugar cane plant. Clomazone and isoxaflutole caused visible injuries to the sugar cane plant. None of the herbicides negatively affected the number of viable culms m² or the culm height and diameter.
Resumo:
Mechanical ventilation has been associated with organ failure in patients with acute respiratory distress syndrome. The present study examines the effects of tidal volume (V T) on renal function using two V T values (8 and 27 mL/kg) in anesthetized, paralyzed and mechanically ventilated male Wistar rats. Animals were randomized into two groups of 6 rats each: V T8 (V T, 8 mL/kg; 61.50 ± 0.92 breaths/min; positive end-expiratory pressure, 3.0 cmH2O; peak airway pressure (PAW), 11.8 ± 2.0 cmH2O), and V T27 (V T, 27 mL/kg; 33.60 ± 1.56 breaths/min; positive end-expiratory pressure, none, and PAW, 22.7 ± 4.0 cmH2O). Throughout the experiment, mean PAW remained comparable between the two groups (6.33 ± 0.21 vs 6.50 ± 0.22 cmH2O). For rats in the V T27 group, inulin clearance (mL·min-1·body weight-1) decreased acutely after 60 min of mechanical ventilation and even more significantly after 90 min, compared with baseline values (0.60 ± 0.05 and 0.45 ± 0.05 vs 0.95 ± 0.07; P < 0.001), although there were no differences between groups in mean arterial pressure or gasometric variables. In the V T8 group, inulin clearance at 120 min of mechanical ventilation remained unchanged in relation to baseline values (0.72 ± 0.03 vs 0.80 ± 0.05). The V T8 and V T27 groups did not differ in terms of serum thiobarbituric acid reactive substances (3.97 ± 0.27 vs 4.02 ± 0.45 nmol/mL) or endothelial nitric oxide synthase expression (94.25 ± 2.75 vs 96.25 ± 2.39%). Our results show that glomerular filtration is acutely affected by high tidal volume ventilation but do not provide information about the mechanism.
Resumo:
Background: The Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) have a impact on the respiratory system and the recommendations for mechanical ventilation of patients with IAH/ACS remain unclear. Our study characterize the influence of elevated intra-abdominal pressure (IAP) and positive end-expiratory pressure (PEEP) on airway plateau pressure (PPLAT) and bladder pressure (PBLAD). Methods: Nine (n=9) deeply anesthetized swine were mechanically ventilated via tracheostomy: volume-controlled mode at tidal volume = 10 ml/kg, frequency=15, Inspiratory:Expiratory ratio=1:2 and PEEP of 1 and 10 cmH2O (PEEP1 and PEEP10, respectively). A tracheostomy tube was place in the peritoneal cavity and different levels of IAP were applied utilizing a CPAP system. Measurements were performed during both PEEP1 and PEEP10. Results: PBLAD increased as experimental IAP rose. Minimal underestimation of IAP by PBLAD was observed. Applying PEEP10 did not significantly affect the correlation between experimental IAP and PBLAD. PBLAD (in cmH2O) was reflected by changes in PPLAT regardless of the PEEP.
Resumo:
Objetivo: Caracterizar a los pacientes que recibieron ventilación mecánica en las unidades de cuidado intensivo (UCI) de la Fundación Santa Fe de Bogotá entre los años 2009 y 2013. Metodología: Se analizó una cohorte retrospectiva de los pacientes en UCI que requirieron soporte ventilatorio mecánico al ingreso a la unidad independientemente de la causa. Resultados: La media de edad de los pacientes fue 63,83 años; el diagnóstico más frecuente de ingreso fue revascularización miocárdica, seguido por neumonía y recambio valvular aórtico; en el 43% de los casos la causa de la falla fue el estado postoperatorio. Los modos ventilatorios más frecuentemente utilizados fueron SIMV (27,5%) y ventilación asistida controlada (26,12%). El 50% de los pacientes fueron ventilados con PEEP < 6 cmH2O. La mortalidad bruta fue del 15%. 22% de los pacientes tuvieron estancia prolongada en UCI. Se aplicó protocolo de retiro de ventilación mecánica en el 77% de los pacientes. La duración de la ventilación mecánica es mayor a medida que aumenta la edad del paciente entre los 60 y los 80 años. La mortalidad es cercana al 50% alrededor de los 50 años y mayor a 80% después de los 80 años. El soporte ventilatorio por cinco o más días aumentó la mortalidad a 80% o más. Discusión y Conclusiones: Estos resultados son comparables a los encontrados en estudios previos. Este estudio puede ser considerado como el primer paso para generar un registro adecuado de la ventilación de la mecánica de las unidades de cuidado intensivo del país.
Resumo:
El dolor es un problema importante para los pacientes hospitalizados en las UCI porque genera malestar y distrés. Además, la investigación ha demostrado que en algunos pacientes críticos el dolor agudo puede persistir después de alta y convertirse en crónico. La gestión eficaz del dolor en pacientes críticos requiere un enfoque interdisciplinario, que incorpore la visión y trabajo de expertos que representan una amplia variedad de especialidades clínicas. Así, la utilización de la intervención psicológica en el tratamiento del dolor es una parte integral de un enfoque global. Basado en una revisión de la evidencia científica, se identifican y señalan: (1) los tipos de dolor más comunes; (2) las características del dolor; (3) las patologías más frecuentes asociadas con la presencia de dolor; (4) los procedimientos que generan dolor en la UCI; (5) los métodos de evaluación del dolor; (6) la intervención del mismo y; (7) la contribución del psicólogo en la evaluación y manejo del dolor con el paciente, los familiares y los profesionales de la salud. La revisión realizada indica que los procesos psicológicos influyen tanto en la experiencia del dolor como en los resultados del tratamiento, por lo tanto la integración de los principios psicológicos en el tratamiento del dolor parecen tener potencial mejora de los resultados beneficiando la salud del paciente.
Resumo:
Relative humidity (RH) measurements, as derived from wet-bulb and dry-bulb thermometers operated as a psychrometer within a thermometer screen, have limited accuracy because of natural ventilation variations. Standard RH calculations generally assume a fixed screen psychrometer coefficient, but this is too small during poor ventilation. By comparing a reference humidity probe—exposed within a screen containing a psychrometer—with wind-speed measurements under controlled conditions, a wind-speed correction for the screen psychrometer coefficient has been derived and applicable when 2-metre wind speeds fall below 3 ms–1. Applying this to hourly-averaged data reduced the mean moist RH bias of the psychrometer (over the reference probe) from 1.2% to 0.4%, and reduced the inter-quartile range of the RH differences from 2.0% to 0.8%. This correction is particularly amenable to automatic measurement systems.
Resumo:
A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust ventilated buildings with warm water heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions. The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and indentify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered. The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20 % without sacrificing ventilation efficiency or thermal comfort. Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught.
Resumo:
Objetivou-se com este trabalho avaliar o controle em pré-emergência de Brachiaria decumbens, Digitaria horizontalis e Panicum maximum pelo herbicida S-metolachlor aplicado em pré-emergência em área de cana-de-açúcar colhida mecanicamente sem queima prévia das plantas, com e sem palha sobre o solo. O delineamento experimental foi o de blocos ao acaso, com quatro repetições, em esquema de parcela subdividida 7 x 2. Nas parcelas, foram estudados cinco tratamentos de herbicidas (S-metolachlor a 1,44, 1,92 e 2,40 kg ha-1; clomazone a 1,20 kg ha-1; e isoxaflutole a 0,188 kg ha-1) e duas testemunhas sem aplicação. Nas subparcelas, foi avaliada a manutenção ou não da palha de cana na superfície do solo. A eficácia do herbicida S-metolachlor não foi prejudicada pela presença de 14 ou 20 t ha-1 de palha de cana sobre o solo. Com a manutenção da palha, a dosagem de S-metolachlor para o controle adequado das plantas daninhas foi de 1,44kgha-1. No ambiente sem palha, o S-metolachlor controlou B. decumbens, D. horizontalis e P. maximum nas dosagens de 1.92, 1.44 e 1.92kgha-1, respectivamente. Nas duas condições de palha, os herbicidas clomazone e isoxaflutole foram eficazes para as espécies estudadas. O S-metolachlor não causou nenhum sintoma visível de intoxicação à cana-de-açúcar. O clomazone e o isoxaflutole ocasionaram injúrias visuais às plantas de cana. Os herbicidas estudados não afetaram o número de colmos viáveis por m², a altura e o diâmetro de colmos.