981 resultados para Unit Groups
Resumo:
The self-assembly of a peptide based on a sequence from the amyloid beta peptide but incorporating the non-natural amino acid beta-2-thienylalanine (2-Thi) has been investigated in aqueous and methanol solutions. The peptide AAKLVFF was used as a design motif, replacing the phenylalanine residues (F) with 2-Thi units to yield (2-Thi)(2-Thi)VLKAA. The 2-Thi residues are expected to confer interesting electronic properties due to charge delocalization and pi-stacking. The peptide is shown to form beta-sheet-rich amyloid fibrils with a twisted morphology, in both water and methanol solutions at sufficiently high concentration. The formation of a self-assembling hydrogel is observed at high concentration. Detailed molecular modeling using molecular dynamics methods was performed using NOE constraints provided by 2D-NMR experiments. The conformational and charge properties of 2-Thi were modeled using quantum mechanical methods, and found to be similar to those previously reported for the beta-3-thienylalanine analogue. The molecular dynamics simulations reveal well-defined folded structures (turn-like) in dilute aqueous solution, driven by self-assembly of the hydrophobic aromatic units, with charged lysine groups exposed to water.
Resumo:
The crystallization behaviour of a series of random copolymers of varying chemical composition is reported. For polymers containing a high proportion of alternating rigid aromatic units and flexible spacers, conventional liquid crystalline and crystalline phase behaviour is observed. The introduction of a substantial fraction of a second shorter rigid unit containing side-chains leads to a broad endotherm in the d.s.c. scan covering some 150°C. Subsequent isothermal crystallization at any point within the broad endotherm leads to the generation of sharp endotherms at temperatures just above the recrystallization temperature. We attribute this behaviour to the crystallization of clusters of molecules containing similar random sequences. Such crystals are non-periodic along the chain direction.
Resumo:
Let G be a finite group and ZG its integral group ring. We show that if alpha is a nontrivial bicyclic unit of ZG, then there are bicyclic units beta and gamma of different types, such that
Resumo:
Analogous to *-identities in rings with involution we define *-identities in groups. Suppose that G is a torsion group with involution * and that F is an infinite field with char F not equal 2. Extend * linearly to FG. We prove that the unit group U of FG satisfies a *-identity if and only if the symmetric elements U(+) satisfy a group identity.
Resumo:
We consider locally nilpotent subgroups of units in basic tiled rings A, over local rings O which satisfy a weak commutativity condition. Tiled rings are generalizations of both tiled orders and incidence rings. If, in addition, O is Artinian then we give a complete description of the maximal locally nilpotent subgroups of the unit group of A up to conjugacy. All of them are both nilpotent and maximal Engel. This generalizes our description of such subgroups of upper-triangular matrices over O given in M. Dokuchaev, V. Kirichenko, and C. Polcino Milies (2005) [3]. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
The aim of this study was to determine the influence of three light-curing units, storage times and colors of the dental composite resin on the fluorescence. The specimens (diameter 10.0 +/- 0.1 mm, thickness 1.0 +/- 0.1 mm) were made using a stainless steel mold. The mold was filled with the microhybrid composite resin and a polyethylene film covered each side of the mold. After this, a glass slide was placed on the top of the mold. To standardize the top surface of the specimens a circular weight (1 kg) with an orifice to pass the light tip of the LCU was placed on the top surface and photo-activated during 40 s. Five specimens were made for each group. The groups were divided into 9 groups following the LCUs (one QTH and two LEDs), storage times (immediately after curing, 24 hours, 7 and 30 days) and colors (shades: A(2)E, A(2)D, and TC) of the composite resin. After photo-activation, the specimens were storage in artificial saliva during the storage times proposed to each group at 37 C and 100% humidity. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed no significant difference between storage times (immediately, 24 hours and 30 days) (P > 0.05). The means of fluorescence had difference significant to color and light-curing unit used to all period of storage (P < 0.05). The colors had difference significant between them (shades: A2D < A2E < TC) (P < 0.05). The Ultraled (LED) and Ultralux (QTH) when used the TC shade showed higher than Radii (LED), however to A2E shade and A2D shade any difference were found (P > 0.05).
Resumo:
Purpose: To evaluate the effect of cement shade, light-curing unit, and water storage on tensile bond strength (a) of a feldspathic ceramic resin bonded to dentin.Materials and Methods: The dentin surface of 40 molars was exposed and etched with 37% phosphoric acid, then an adhesive system was applied. Forty blocks of feldspathic ceramic (Vita VM7) were produced. The ceramic surface was etched with 10% hydrofluoric acid for 60 s, followed by the application of a silane agent and a dual-curing resin cement (Variolink II). Ceramic blocks were cemented to the treated dentin using either A3 or transparent (Tr) shade cement that was activated using either halogen or LED light for 40 s. All blocks were stored in 37 degrees C distilled water for 24 h before cutting to obtain non-trimmed bar-shaped specimens (adhesive area = 1 mm(2) +/- 0.1) for the microtensile bond strength test. The specimens were randomly grouped according to the storage time: no storage or stored for 150 days in 37 degrees C distilled water. Eight experimental groups were obtained (n = 30). The specimens were submitted to the tensile bond strength test using a universal testing machine at a crosshead speed of 1 mm/min. The data were statistically analyzed using ANOVA and Tukey's post-hoc tests (alpha = 0.05).Results: The mean bond strength values were significantly lower for the corresponding water stored groups, except for the specimens using A3 resin cement activated by halogen light. There was no significance difference in mean bond strength values among all groups after water storage.Conclusion: Water storage had a detrimental effect under most experimental conditions. For both cement shades investigated (Tr and A3) under the same storage condition, the light-curing units (QTH and LED) did not affect the mean microtensile bond strengths of resin-cemented ceramic to dentin.
Resumo:
CONTEXTO: Embora cerca de 30% a 50% dos pacientes hospitalizados em unidades de terapia intensiva (UTI) recebam algum tipo de sedativo, existe escassez de informações sobre efeitos adversos desta prática, especialmente no Brasil. Estes efeitos podem ser significantes e o uso de sedativos é associado a elevação de infecção e mortalidade, mesmo sendo difícil avaliar o impacto clínico deste procedimento. OBJETIVO: Avaliar o impacto da sedação sobre incidência de complicações e mortalidade em doentes graves durante internação em unidade de terapia intensiva. TIPO DE ESTUDO: Estudo prospectivo. LOCAL: Unidade de Terapia Intensiva Cirúrgica da Universidade Federal de São Paulo (UNIFESP) - Escola Paulista de Medicina. PARTICIPANTES: Após excluídos pacientes que permaneceram menos de 24 horas ou sem exames indispensáveis para o cálculo do índice de gravidade (APACHE II), restaram 307 pacientes. Estes foram divididos em dois grupos: Grupo Sedado e Grupo Não Sedado. Constatada heterogeneidade com relação ao APACHE II, foram pareados 97 sedados e 97 não sedados com idênticos índices de gravidade. VARIÁVEIS ESTUDADAS: Impacto da sedação e das técnicas sobre a mortalidade, tempo de internação, além da incidência de escara de decúbito ou pressão, trombose venosa profunda e infecção. RESULTADOS: Não houve diferença na incidência de trombose venosa profunda, entre os grupos Sedado e Não Sedado, enquanto que escara de decúbito foi significativamente maior nos sedados (p = 0,03). Infecção foi detectada em 45,4% dos pacientes com sedação e em 21,6% dos pacientes sem sedação (p = 0,006). A mortalidade para os pacientes que não receberam qualquer tipo de sedativo foi de 20,6% e, para aqueles que foram sedados durante a internação, foi de 52,6% (p < 0,0001). CONCLUSÕES: Conclui-se que a sedação está associada a maior duração da internação, morbidade e mortalidade significativas. Apesar da intensidade das associações encontradas, não é possível estabelecer relação causal entre sedação e mortalidade.
Resumo:
Resumo:
The integration of outcrop and subsurface information, including micropaleontological data, facies and sequence stratigraphic studies, and oxygen isotope analysis, allow us to present a new stratigraphic model for the Cretaceous continental deposits of the Bauru Group, Brazil. Thirty-eight fossil taxa were recovered from these deposits, including 29 species of ostracodes and 9 species of charophytes. Seven of these ostracode species and three subspecies are new and formally described here. The associations of Chara barbosai - Ilyocypris cf. riograndensis, found in the Adamantina Formation, and Amblyochara sp. - Neuquenocypris minor mineira nov. subsp., found in the Marília Formation. Ponte Alta Member, represent two distinct groups that are respectively Turonian-Santonian and Maastrichtian (probably Late Maastrichtian) in age. Therefore, a hiatus, encompassing more than 11 Ma, separates those two formations. From bottom to top, four depositional cycles were recognized in the Bauru Group in western São Paulo: cycles 1 and 2 belong to Caiuá Formation (fluvio-lacustrine and lacustrine deposits in the Presidente Prudente region), cycle 3 to the Santo Anastácio and lower Adamantina Formation (respectively fluvial and lacustrine deposits), and cycle 4 to the upper Adamantina Formation (fluvio-lacustrine facies). An erosional unconformity separates the Caiuá and Santo Anastácio Formations (between cycles 2 and 3). The Marília Formation is a distinct unit from the underlying succession; it does not occur in western São Paulo, but is found in restricted areas of São Paulo, Minas Gerais, Mato Grosso do Sul and Goiás States. During the deposition of the Bauru Group (Aptian? to Maastrichtian) the climate was hot and arid-semiarid. Shallow lakes underwent fluctuations in expansion (wet phases) and contraction (dry phases), as well as variations in salinity. During the deposition of the Adamantina Formation (Turonian-Santonian) there were long, dry periods that caused segmentation of large lakes (due to topographic irregularities in the basaltic substrate) and sometimes exposures of the lake floors; when flooded these lake floors were colonized by extensive meadows of single species of charophytes. Small ephemeral ponds, that were hydrochemically unstable and colonized by multiple species of charophytes, were the depositional sites for the marls and mudstones of Ponte Alta Member (Maastrichtian, Late Maastrichtian?). Our micropaleontological age control, combined with the Late Cretaceous ages of volcanic ashes found in the southeastern Brazil coastal basins, and the stratigraphic position of analcimites from the Jaboticabal-SP region, suggest a Late Coniacian-Santonian age for important magmatic events occurred in the interior of Brazil (north-central São Paulo State, Triângulo Mineiro, and southwestern Goiás State).
Resumo:
The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric acid/60s and silanized. The dentin was treated with37% phosphoric acid/15s, and the adhesive was applied. The ceramic blocks were divided and cemented to dentin according to resin cement/RC curing type(dual-and photocured), light-curing unit (halogen light/QTH and LED), and storage conditions (dry and storage/150 days + 12,000 cycles/thermocycling). All blocks were stored in distilled water (37°C/24h) and sectioned (n = 10): G1-QTH + RC Photo, G2-QTH + RC Dual, G3-LED + RC Photo, G4-LED + RC Dual. Groups G5, G6, G7, and G8 were obtained exactly as G1 through G4, respectively, and then stored and thermocycled. Microtensile bond strength tests were performed (EMIC), and data were statistically analyzed by ANOVA and Tukey's test (5%). The bond strength values (MPa) were: G1-12.95 (6.40)ab; G2-12.02 (4.59)ab; G3-13.09 (5.62)ab; G4-15.96 (6.32)a; G5-6.22 (5.90)c; G6-9.48 (5.99)bc; G7-12.78 (11.30)ab; and G8-8.34 (5.98)bc. The same superscript letters indicate no significant differences. Different light-curing units affected the bond strength betweenceramic cemented to dentin when the photocured cement was used, and only after aging (LED>QTH). There was no difference between the effects of dual-and photo-cured resin-luting agents on the microtensile bond strength of the cement used in this study.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)
Resumo:
Nella tesi vengono presentate alcune relazioni fra gruppi quantici e modelli reticolari. In particolare si associa un modello vertex a una rappresentazione di un'algebra inviluppante quantizzata affine e si mostra che, specializzando il parametro quantistico ad una radice dell'unità, si manifestano speciali simmetrie.
Resumo:
AIM: To compare the 10-year peri-implant bone loss (BL) rate in periodontally compromised (PCP) and periodontally healthy patients (PHP) around two different implant systems supporting single-unit crowns. MATERIALS AND METHODS: In this retrospective, controlled study, the mean BL (mBL) rate around dental implants placed in four groups of 20 non-smokers was evaluated after a follow-up of 10 years. Two groups of patients treated for periodontitis (PCP) and two groups of PHP were created. For each category (PCP and PHP), two different types of implant had been selected. The mBL was calculated by subtracting the radiographic bone levels at the time of crown cementation from the bone levels at the 10-year follow-up. RESULTS: The mean age, mean full-mouth plaque and full-mouth bleeding scores and implant location were similar between the four groups. Implant survival rates ranged between 85% and 95%, without statistically significant differences (P>0.05) between groups. For both implant systems, PCP showed statistically significantly higher mBL rates and number of sites with BL> or =3 mm compared with PHP (P<0.0001). CONCLUSIONS: After 10 years, implants in PCP yielded lower survival rates and higher mean marginal BL rates compared with those of implants placed in PHP. These results were independent of the implant system used or the healing modality applied.