858 resultados para Unit
Resumo:
In 2002, an integrated basic science course was introduced into the Bachelor of Dental Sciences programme at the University of Queensland, Australia. Learning activities for the Metabolism and Nutrition unit within this integrated course included lectures, problem-based learning tutorials, computer-based self-directed learning exercises and practicals. To support student learning and assist students to develop the skills necessary to become lifelong learners, an extensive bank of formative assessment questions was set up using the commercially available package, WebCT®. Questions included short-answer, multiple-choice and extended matching questions. As significant staff time was involved in setting up the question database, the extent to which students used the formative assessment and their perceptions of its usefulness to their learning were evaluated to determine whether formative assessment should be extended to other units within the course. More than 90% of the class completed formative assessment tasks associated with learning activities scheduled in the first two weeks of the block, but this declined to less than 50% by the fourth and final week of the block. Patterns of usage of the formative assessment were also compared in students who scored in the top 10% for all assessment for the semester with those who scored in the lowest 10%. High-performing students accessed the Web-based formative assessment about twice as often as those who scored in the lowest band. However, marks for the formative assessment tests did not differ significantly between the two groups. In a questionnaire that was administered at the completion of the block, students rated the formative assessment highly, with 80% regarding it as being helpful for their learning. In conclusion, although substantial staff time was required to set up the question database, this appeared to be justified by the positive responses of the students.
Resumo:
In this study, a combination of recA-based PCR assays and 16S rDNA restriction fragment length polymorphism (RFLP) analysis was used to determine the genomovar diversity of clinical Burkholderia cepacia complex isolates. Twenty-eight isolates were prospectively collected from patients attending a large Australian adult cystic fibrosis (CF) unit, 22 isolates were referred from other Australian CF units and a further eight isolates originated from patients without CF. The 28 prospectively collected isolates were distributed amongst the following genomovars: Burkholderia cepacia genomovar I (28.6%), Burkholderia multivorans (21.4%), Burkholderia cepacia genomovar III (39.3%), Burkholderia vietnamiensis (3.6%) and Burkholderia ambifaria (7.1%). The results of this study highlight the usefulness of 16S rDNA RFLP typing for the identification of other Burkholderia spp. and non-fermenting gram-negative bacteria.
Resumo:
This article presents a research work, the goal of which was to achieve a model for the evaluation of data quality in institutional websites of health units in a broad and balanced way. We have carried out a literature review of the available approaches for the evaluation of website content quality, in order to identify the most recurrent dimensions and the attributes, and we have also carried out a Delphi method process with experts in order to reach an adequate set of attributes and their respective weights for the measurement of content quality. The results obtained revealed a high level of consensus among the experts who participated in the Delphi process. On the other hand, the different statistical analysis and techniques implemented are robust and attach confidence to our results and consequent model obtained.
Resumo:
This paper proposes a practical approach for profit-based unit commitment (PBUC) with emission limitations. Under deregulation, unit commitment has evolved from a minimum-cost optimisation problem to a profit-based optimisation problem. However, as a consequence of growing environmental concern, the impact of fossil-fuelled power plants must be considered, giving rise to emission limitations. The simultaneous address of the profit with the emission is taken into account in our practical approach by a multiobjective optimisation (MO) problem. Hence, trade-off Curves between profit and emission are obtained for different energy price profiles, in a way to aid decision-makers concerning emission allowance trading. Moreover, a new parameter is presented, ratio of change, and the corresponding gradient angle, enabling the proper selection of a compromise commitment for the units. A case study based on the standard IEEE 30-bus system is presented to illustrate the proficiency Of Our practical approach for the new competitive and environmentally constrained electricity supply industry.
Resumo:
This paper is on the unit commitment problem, considering not only the economic perspective, but also the environmental perspective. We propose a bi-objective approach to handle the problem with conflicting profit and emission objectives. Numerical results based on the standard IEEE 30-bus test system illustrate the proficiency of the proposed approach.
Resumo:
The production of MVOC by fungi has been taken into account especially from the viewpoint of indoor pollution with microorganisms but the relevance of fungal metabolites in working environments has not been sufficiently studied. The purpose of this study was to assess exposure to MVOCs in a waste-handling unit. It was used Multirae equipment (RAE Systems) to measured MVOCs concentration with a 10.6 eV lamps. The measurements were done near workers nose and during the normal activities. All measurements were done continuously and had the duration of 5 minutes at least. It was consider the higher value obtained in each measurement. In addition, for knowing fungi contamination, five air samples of 50 litres were collected through impaction method at 140 L/minute, at one meter tall, on to malt extract agar with the antibiotic chloramphenicol (MEA). MVOCs results range between 4.7 ppm and 8.9 ppm in the 6 locations consider. These results are eight times higher than normally obtained in indoor settings. Considering fungi results, two species were identified in air, being the genera Penicillium found in all the samples in uncountable colonies and Rhizopus only in one sample (40 UFC/m3). These fungi are known as MVOCs producers, namely terpenoids, ketones, alcohols and others. Until now, there has been no evidence that MVOCs are toxicologically relevant, but further epidemiological research is necessary to elucidate their role on human’s health, particularly in occupational settings where microbiological contamination is common. Additionally, further research should concentrate on quantitative analyses of specific MVOCs.
Resumo:
Clinical education is recognized as being crucial for the training of health professionals. This subject is debated amongst teachers, students and professionals. Besides the clinical and research skills, we look for other competencies such as oratory, creative thinking or leadership. We present the results of a study with 4th graders. It’s a exploratory study; the main purpose was to evaluate the outcomes of a unit of clinical education prepared according a new set of competencies and methodologies. The competencies were seen as valuable. Organization, leading or supporting a colleague, rethinking a program to serve client and family are equally important.
Resumo:
This paper presents a complete, quadratic programming formulation of the standard thermal unit commitment problem in power generation planning, together with a novel iterative optimisation algorithm for its solution. The algorithm, based on a mixed-integer formulation of the problem, considers piecewise linear approximations of the quadratic fuel cost function that are dynamically updated in an iterative way, converging to the optimum; this avoids the requirement of resorting to quadratic programming, making the solution process much quicker. From extensive computational tests on a broad set of benchmark instances of this problem, the algorithm was found to be flexible and capable of easily incorporating different problem constraints. Indeed, it is able to tackle ramp constraints, which although very important in practice were rarely considered in previous publications. Most importantly, optimal solutions were obtained for several well-known benchmark instances, including instances of practical relevance, that are not yet known to have been solved to optimality. Computational experiments and their results showed that the method proposed is both simple and extremely effective.
Resumo:
This paper proposes a stochastic mixed-integer linear approach to deal with a short-term unit commitment problem with uncertainty on a deregulated electricity market that includes day-ahead bidding and bilateral contracts. The proposed approach considers the typically operation constraints on the thermal units and a spinning reserve. The uncertainty is due to the electricity prices, which are modeled by a scenario set, allowing an acceptable computation. Moreover, emission allowances are considered in a manner to allow for the consideration of environmental constraints. A case study to illustrate the usefulness of the proposed approach is presented and an assessment of the cost for the spinning reserve is obtained by a comparison between the situation with and without spinning reserve.
Resumo:
This paper presents a single precision floating point arithmetic unit with support for multiplication, addition, fused multiply-add, reciprocal, square-root and inverse squareroot with high-performance and low resource usage. The design uses a piecewise 2nd order polynomial approximation to implement reciprocal, square-root and inverse square-root. The unit can be configured with any number of operations and is capable to calculate any function with a throughput of one operation per cycle. The floatingpoint multiplier of the unit is also used to implement the polynomial approximation and the fused multiply-add operation. We have compared our implementation with other state-of-the-art proposals, including the Xilinx Core-Gen operators, and conclude that the approach has a high relative performance/area efficiency. © 2014 Technical University of Munich (TUM).
Resumo:
OBJECTIVE To analyze the clinical and laboratory characteristics of HIV-infected individuals upon admission to a reference health care center.METHODS This cross-sectional study was conducted between 1999 and 2010 on 527 individuals with confirmed serological diagnosis of HIV infection who were enrolled in an outpatient health care service in Santarém, PA, Northern Brazil. Data were collected from medical records and included the reason for HIV testing, clinical status, and count of peripheral CD4+ T lymphocytes upon enrollment. The data were divided into three groups, according to the patient’s year of admission – P1 (1999-2002), P2 (2003-2006), and P3 (2007-2010) – for comparative analysis of the variables of interest.RESULTS In the study group, 62.0% of the patients were assigned to the P3 group. The reason for undergoing HIV testing differed between genders. In the male population, most tests were conducted because of the presence of symptoms suggesting infection. Among women, tests were the result of knowledge of the partner’s seropositive status in groups P1 and P2. Higher proportion of women undergoing testing because of symptoms of HIV/AIDS infection abolished the difference between genders in the most recent period. A higher percentage of patients enrolling at a more advanced stage of the disease was observed in P3.CONCLUSIONS Despite the increased awareness of the number of HIV/AIDS cases, these patients have identified their serological status late and were admitted to health care units with active disease. The HIV/AIDS epidemic in Pará presents specificities in its progression that indicate the complex characteristics of the epidemic in the Northern region of Brazil and across the country.
Impact of a price-maker pumped storage hydro unit on the integration of wind energy in power systems
Resumo:
The increasing integration of larger amounts of wind energy into power systems raises important operational issues, such as the balance between power generation and demand. The pumped storage hydro (PSH) units are one possible solution to mitigate this problem, once they can store the excess of energy in the periods of higher generation and lower demand. However, the behaviour of a PSH unit may differ considerably from the expected in terms of wind power integration when it operates in a liberalized electricity market under a price-maker context. In this regard, this paper models and computes the optimal PSH weekly scheduling in a price-taker and price-maker scenarios, either when the PSH unit operates in standalone and integrated in a portfolio of other generation assets. Results show that the price-maker standalone PSH will integrate less wind power in comparison with the price-taker situation. Moreover, when the PSH unit is integrated in a portfolio with a base load power plant, the role of the price elasticity of demand may completely change the operational profile of the PSH unit. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
This paper proposes a stochastic mixed-integer linear approach to deal with a short-term unit commitment problem with uncertainty on a deregulated electricity market that includes day-ahead bidding and bilateral contracts. The proposed approach considers the typically operation constraints on the thermal units and a spinning reserve. The uncertainty is due to the electricity prices, which are modeled by a scenario set, allowing an acceptable computation. Moreover, emission allowances are considered in a manner to allow for the consideration of environmental constraints. A case study to illustrate the usefulness of the proposed approach is presented and an assessment of the cost for the spinning reserve is obtained by a comparison between the situation with and without spinning reserve.
Resumo:
The integration of large amounts of wind energy in power systems raises important operation issues such as the balance between power demand and generation. The pumped storage hydro (PSH) units are seen as one solution for this issue, avoiding the need for wind power curtailments. However, the behavior of a PSH unit might differ considerably when it operates in a liberalized market with some degree of market power. In this regard, a new approach for the optimal daily scheduling of a PSH unit in the day-ahead electricity market was developed and presented in this paper, in which the market power is modeled by a residual inverse demand function with a variable elasticity. The results obtained show that increasing degrees of market power of the PSH unit correspond to decreasing levels of storage and, therefore, the capacity to integrate wind power is considerably reduced under these circumstances.