939 resultados para Ultrasonography, Interventional


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Annually hundreds of crab-eating foxes (Cerdocyon thous) are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous) using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12 +/- 0.01 mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1: 1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39 +/- 0.05 mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34 +/- 0.03 mm and three defined layers with hyperechogenic (submucosa and serosa) and hypoechogenic (muscular) features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2 mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60 +/- 0.32 cm/s; EDV: 6.96 +/- 1.68cm/s; PI: 1.15 +/- 0.07 e RI: 0.73 +/- 0.07) and right (PSV: 23.08 +/- 3.34cm/s; EDV: 9.33 +/- 2.36cm/s; PI: 1.01 +/- 0.65 e RI: 0.65 +/- 0.16) and left renal arteries (PSV: 23.74 +/- 3.94cm/s; EDV: 9.07 +/- 3.02cm/s; PI: 1.04 +/- 0.31 e RI: 0.64 +/- 0.10) were determined. Thus, conventional and Doppler ultrasonographic imaging provides basic information that can be used as reference for the species as well for other wild canids and it is a precise and non-invasive method that can be safely used to evaluate and diagnose abdominal injuries in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain metastases (BM) are one of the most common intracranial tumors and surgical treatment can improve both the functional outcomes and patient survival, particularly when systemic disease is controlled. Image-guided BM resection using intraoperative exams, such as intraoperative ultrasound (IOUS), can lead to better surgical results. Methods: To evaluate the use of IOUS for BM resection, 20 consecutives patients were operated using IOUS to locate tumors, identify their anatomical relationships and surgical cavity after resection. Technical difficulties, complications, recurrence and survival rates were noted. Results: IOUS proved effective for locating, determining borders and defining the anatomical relationships of BM, as well as to identify incomplete tumor resection. No complications related to IOUS were seen. Conclusion: IOUS is a practical supporting method for the resection of BM, but further studies comparing this method with other intraoperative exams are needed to evaluate its actual contribution and reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reproductive diseases are a great barrier to dairy production, as they diminish fertility and cause economic loss. In this context, endometritis plays an important role. Different diagnostic techniques exist for endometritis that vary in sensitivity and specificity. This work aimed to evaluate and compare ultrasonographic and histopathological examinations, and combinations thereof, for the diagnosis of endometritis by determining their sensitivity, specificity, and kappa agreement coefficients using endometrial cytology as the gold standard. We developed an adaptive reading score to perform histological examination of the uterus. In this study, 76 Holstein-Friesian cows, 21 to 47 d postpartum, without vaginal catarrh were submitted to gynecological examinations, including ultrasonographic examination, an endometrial cytology examination, and a uterine biopsy. Our results indicate that ultrasonography is a practical and effective diagnostic method, and a combination of the determination of intrauterine fluid and cervical diameter was the most efficient ultrasonographic method, with 50% sensitivity and 88% specificity. Histopathological examination was a useful diagnostic method that provided rich detail on endometrial inflammation, and allowed evaluation of different components of the tissue such as the epithelium, lamina propria, endometrial glands, and blood vessels; this method had 44% sensitivity and 92% specificity for diagnosis of endometritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Few equations have been developed in veterinary medicine compared to human medicine to predict body composition. The present study was done to evaluate the influence of weight loss on biometry (BIO), bioimpedance analysis (BIA) and ultrasonography (US) in cats, proposing equations to estimate fat (FM) and lean (LM) body mass, as compared to dual energy x-ray absorptiometry (DXA) as the referenced method. For this were used 16 gonadectomized obese cats (8 males and 8 females) in a weight loss program. DXA, BIO, BIA and US were performed in the obese state (T0; obese animals), after 10% of weight loss (T1) and after 20% of weight loss (T2). Stepwise regression was used to analyze the relationship between the dependent variables (FM, LM) determined by DXA and the independent variables obtained by BIO, BIA and US. The better models chosen were evaluated by a simple regression analysis and means predicted vs. determined by DXA were compared to verify the accuracy of the equations. Results: The independent variables determined by BIO, BIA and US that best correlated (p < 0.005) with the dependent variables (FM and LM) were BW (body weight), TC (thoracic circumference), PC (pelvic circumference), R (resistance) and SFLT (subcutaneous fat layer thickness). Using Mallows'Cp statistics, p value and r(2), 19 equations were selected (12 for FM, 7 for LM); however, only 7 equations accurately predicted FM and one LM of cats. Conclusions: The equations with two variables are better to use because they are effective and will be an alternative method to estimate body composition in the clinical routine. For estimated lean mass the equations using body weight associated with biometrics measures can be proposed. For estimated fat mass the equations using body weight associated with bioimpedance analysis can be proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ipomoea carnea (I. carnea) is a poisonous plant found in Brazil and other tropical countries that often poison livestock. The plant contains the alkaloids calystegines and mainly swainsonine, which inhibit cellular enzymes and cause systematic cell death. The objective of this study was to evaluate the perinatal effects of I. carnea in goats. Methods: Forty-seven pregnant goats were randomly allocated into 5 treatment groups and given the following doses (g/kg BW) of I. carnea: 0 (IC0), 1.0 (IC1), 3.0 (IC3), 5.0 (IC5) and 7.5 (IC7). The treatment animals were given fresh I. carnea from day 27 of gestation to parturition. Weight gains and serum biochemistry were evaluated. Fetuses were evaluated using ultrasonographic measurements. Results: Goats from the IC7 group showed clinical signs of poisoning. Ultrasound examination revealed that I. carnea feeding in all treatment groups reduced fetal movement compared to the controls. There was an increase in the total number of birth defects (retrognathia and arthrogyposis) in the IC7 and IC5 groups compared to the controls. Conclusion: The results show that I. carnea has teratogenic potential in goats. In addition, ultrasounds were useful in evaluating fetotoxicity and teratogenicity. Birth Defects Res (Part B) 00:17, 2012. (c) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Endoscopic retrograde cholangiopancreatography may fail because of malignant involvement of the second portion of the duodenum and the major papilla. Alternatives include percutaneous transhepatic biliary drainage (PTBD) or surgical bypass. Endoscopic ultrasonography-guided choledochoduodenostomy (EUS-CD) has been reported as an alternative. Objective: To prospectively compare EUS-CD and PTBD in patients with unresectable malignant biliary obstruction. Design: Prospective and randomized study. Setting: Tertiary center. Main Outcome Measurements: Success and efficacy comparison EUS-CD with PTBD. Results: Twenty-five subjects were randomized (13 EUS-CD and 12 PTBD). Mean age was 67 years (SD, 11.9). The 2 groups were similar before intervention in terms of quality of life [EUS-CD (58.3) vs. PTBD (57.8); P = 0.78], total bilirubin (16.4 vs. 17.2; P = 0.7), alkaline phosphatase (539 vs. 518; P = 0.7), and gamma-glutamyl transferase (554.3 vs. 743.5; P = 0.56). All procedures were technically and clinically successful in both groups. At 7-day follow-up there was a significant reduction in total bilirubin in both the groups (EUS-CD, 16.4 to 3.3; P = 0.002 and PTBD, 17.2 to 3.8; P = 0.01), although no difference was noted comparing the 2 groups (EUS-CD to PTBD; 3.3 vs. 3.8; P = 0.2). There was no difference between the complication rates in the 2 groups (P = 0.44), EUS-CD (2/13; 15.3%) and PTBD (3/12; 25%). Costs were similar in the 2 groups also ($5673-EUS-CD vs. $7570-PTBD; P = 0.39). Limitations: Small sample size and single center study. Conclusions: EUS-CD can be an effective and safe alternative to PTBD with similar success, complication rate, cost, and quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements on the growth process and placental development of the embryo and fetuses of Cavia porcellus were carried out using ultrasonography. Embryo, fetus, and placenta were monitored from Day 15 after mating day to the end of gestation. Based on linear and quadratic regressions, the following morphometric analysis showed a good indicator of the gestational age: placental diameter, biparietal diameter, renal length, and crown rump. The embryonic cardiac beat was first detected at an average of 22.5 days. The placental diameter showed constant increase from beginning of gestation then remained to term and presented a quadratic correlation with gestational age (r2 = 0.89). Mean placental diameter at the end of pregnancy was 3.5 ± 0.23 cm. By Day 30, it was possible to measure biparietal diameter, which followed a linear pattern of increase up to the end of gestation (r2 = 0.95). Mean biparietal diameter in the end of pregnancy was 1.94 ± 0.03 cm. Kidneys were firstly observed on Day 35 as hyperechoic structures without the distinction of medullar and cortical layers, thus the regression model equation between kidney length and gestational age presents a quadratic relationship (r2 = 0.7). The crown rump presented a simple linear growth, starting from 15 days of gestation, displaying a high correlation with the gestational age (r2 = 0.9). The offspring were born after an average gestation of 61.3 days. In this study, we conclude that biparietal diameter, placental diameter, and crown rump are adequate predictive parameters of gestational age in guinea pigs because they present high correlation index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] OBJECTIVE: Our hypothesis is that sonography performed by the rheumatologist in patients with suspected carpal tunnel syndrome (CTS) has higher diagnostic value compared to physical evaluation. METHODS: Adult patients with suspected idiopathic CTS, defined by sensory symptoms over the distribution of the median nerve with or without positive results with the Phalen and/or the Tinel's maneuvers were included. The diagnosis of CTS was indicated by typical symptoms daily for at least 3 months and a positive nerve conduction study. One rheumatologist unaware of the clinical and electrodiagnostic results performed an ultrasound examination of the median nerve for the area ranging from the inlet to the outlet of the carpal tunnel. Mean cross-sectional area at each level, flattening ratio and bowing of flexor retinaculum were obtained. RESULTS: Sixty-eight patients with 105 affected wrists were examined. Tinel's and Phalen's signs had a closer sensitivity (73% and 67% respectively) and specificity (40% and 30% respectively). The best swelling nerve cut-off by sonography was 9.7 mm2 at the tunnel inlet, with a sensitivity of 86%, a specificity of 48% and accuracy of 77%. A 100% positive predictive value was reached with a cross-sectional area of 13 mm2, involving 33 hands (31% of the whole sample). Maximal cross sectional area and the measurement of flexor retinaculum had an accuracy of 72% and 73% respectively. Combination of physical maneuvers and sonography not yielded more accuracy than cross-sectional area itself. CONCLUSION: In patients with clinical history of idiopathic CTS and positive nerve conduction study, sonography performed by the rheumatologist has higher diagnostic value than physical maneuvers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] OBJECTIVES: To assess the usefulness of clinical findings, nerve conduction studies and ultrasonography performed by a rheumatologist to predict success in patients with idiopathic carpal tunnel syndrome (CTS) undergoing median nerve release. METHODS: Ninety consecutive patients with CTS (112 wrists) completed a specific CTS questionnaire and underwent physical examination and nerve conduction studies. Ultrasound examination was performed by a rheumatologist who was blind to any patient's data. Outcome variables were improvement >25% in symptoms of the CTS questionnaire and patient's overall satisfaction (5-point Likert scale) at 3 months postoperatively. Success was defined as improvement in both outcome variables. Receiver operating characteristics (ROC) curves and logistic regression analyses were used to assess the best predictive combination of preoperative findings. RESULTS: Success was achieved in 63% of the operated wrists. Utility parameters and area under the ROC curve (AUC) for individual findings was poor, ranging from 0.481 of the nerve conduction study to 0.634 of the cross-sectional area at tunnel outlet. Logistic regression identified the preoperative US parameters as the best predictive variables for success after 3 months. The best predictive combination (AUC=0.708) included a negative Phalen maneuver, plus absence of thenar atrophy, plus less than moderately abnormalities on nerve conduction studies plus a large maximal cross-sectional area along the tunnel by ultrasonography. CONCLUSION: Although cross-sectional area of the median nerve was the only predictor of success after three months of surgical release, isolated preoperative findings are not reliable predictors of success in patients with idiopathic CTS. A combination of findings that include ultrasound improves prediction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonography (US) is an essential imaging tool for identifying abnormalities of the liver parenchyma, biliary tract and vascular system. US has replaced radiography as the initial imaging procedure in screening for liver disease in small animals. There are few reports of the use of conventional and helical computed tomography (CT) to assess canine or feline parenchymal and neoplastic liver disease and biliary disorders. In human medicine the development of multidetector- row helical computed tomography (MDCT), with its superior spatial and temporal resolution, has resulted in improved detection and characterization of diffuse and focal liver lesions. The increased availability of MDCT in veterinary practice provides incentive to develop MDCT protocols for liver imaging in small animals. The purpose of this study is to assess the rule of MDCT in the characterization of hepatobiliary diseases in small animals; and to compare this method with conventional US. Candidates for this prospective study were 175 consecutive patients (dogs and cats) referred for evaluation of hepatobiliary disease. The patients underwent liver US and MDCT. Percutaneous needle biopsy was performed on all liver lesions or alterations encountered. As for gallbladder, histopatological evaluation was obtained from cholecystectomy specimens. Ultrasonographic findings in this study agreed well with those of previous reports. A protocol for dual-phase liver MDCT in small animals has been described. MDCT findings in parenchymal disorders of the liver, hepatic neoplasia and biliary disorders are here first described in dogs and cats and compared with the corresponding features in human medicine. The ability of MDCT in detection and characterization of hepatobiliary diseases in small animals is overall superior to conventional US. Ultrasonography and MDCT scanning, however, play complementary rules in the evaluation of these diseases. Many conditions have distinctive imaging features that may permit diagnosis. In most instances biopsy is required for definitive diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study evaluates cardiovascular risk factors associated with progression of coronary artery disease (CAD) in patientswith silent ischemia followingmyocardial infarction. Hypothesis: Coronary artery disease only progresses slowly with comprehensive risk factor intervention. Methods: A total of 104 of 201 patients (51.7%) of the Swiss Interventional Study on Silent Ischemia Type II (SWISSI II) with baseline and follow-up coronary angiography were included. All patients received comprehensive cardiovascular risk factor intervention according to study protocol. Logistic regression was used to evaluate associationsbetween baseline cardiovascular risk factors and CAD progression. Results: The mean duration of follow-upwas 10.3 ± 2.4 years. At baseline, 77.9% of patients were smokers, 45.2% had hypertension, 73.1% had dyslipidemia, 7.7% had diabetes, and 48.1% had a family history of CAD. At last follow-up, only 27 patients of the initial 81 smokers still smoked, only 2.1% of the patients had uncontrolled hypertension, 10.6%of the patientshad uncontrolled dyslipidemia, and 2.1%of the patientshad uncontrolled diabetes. Coronary artery disease progression was found in up to 81 (77.9%) patients. Baseline diabetes and younger age were associatedwith increased odds of CAD progression.The time intervalbetween baseline and follow-up angiography was also associatedwith CAD progression. Conclusion: Coronary artery disease progressionwas highly prevalent in these patients despite comprehensive risk factor intervention. Further research is needed to optimize treatment of known risk factors and to identify other unknown and potentiallymodifiable risk factors.