857 resultados para U Test of Mann-Whitney
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: The increasing number of reports on the relation between transfusion of stored red blood cells (RBCs) and adverse patient outcome has sparked an intense debate on the benefits and risks of blood transfusions. Meanwhile, the pathophysiological mechanisms underlying this postulated relation remain unclear. The development of hemolysis during storage might contribute to this mechanism by release of free hemoglobin (fHb), a potent nitric oxide (NO) scavenger, which may impair vasodilation and microcirculatory perfusion after transfusion. The objective of this prospective observational pilot study was to establish whether RBC transfusion results in increased circulating fHb levels and plasma NO consumption. In addition, the relation between increased fHb values and circulating haptoglobin, its natural scavenger, was studied. Methods: Thirty patients electively received 1 stored packed RBC unit (n = 8) or 2 stored packed RBC units (n = 22). Blood samples were drawn to analyze plasma levels of fHb, haptoglobin, and NO consumption prior to transfusion, and 15, 30, 60 and 120 minutes and 24 hours after transfusion. Differences were compared using Pearson's chi-square test or Fisher's exact test for dichotomous variables, or an independent-sample t test or Mann-Whitney U test for continuous data. Continuous, multiple-timepoint data were analyzed using repeated one-way analysis of variance or the Kruskall-Wallis test. Correlations were analyzed using Spearman or Pearson correlation. Results: Storage duration correlated significantly with fHb concentrations and NO consumption within the storage medium (r = 0.51, P < 0.001 and r = 0.62, P = 0.002). fHb also significantly correlated with NO consumption directly (r = 0.61, P = 0.002). Transfusion of 2 RBC units significantly increased circulating fHb and NO consumption in the recipient (P < 0.001 and P < 0.05, respectively), in contrast to transfusion of 1 stored RBC unit. Storage duration of the blood products did not correlate with changes in fHb and NO consumption in the recipient. In contrast, pre-transfusion recipient plasma haptoglobin levels inversely influenced post-transfusion fHb concentrations. Conclusion: These data suggest that RBC transfusion can significantly increase post-transfusion plasma fHb levels and plasma NO consumption in the recipient. This finding may contribute to the potential pathophysiological mechanism underlying the much-discussed adverse relation between blood transfusions and patient outcome. This observation may be of particular importance for patients with substantial transfusion requirements.
Resumo:
PURPOSE: To evaluate the nutritional status of patients in the late postoperative period of pancreaticoduodenectomy (PD) and compare the long-term outcome according to pylorus-preserving (PPPD) or the standard technique (SPD) in which the pylorus is resected. METHODS: This prospective study was conducted twelve months prior or more in patients who had underwent PD (PD Group, n=15) and health volunteers (Control Group, n=15). At a post hoc analysis, the PD Group was divided in PPPD Subgroup (n=9) and SPD Subgroup (n=6), according to the PD techniques. Gastrointestinal complaints and nutritional status were evaluated, apart from a biochemical assessment; Student t-test or Mann-Whitney test were used. RESULTS: The patients recovered their body weight and the gastrointestinal complaints were uncommon. The PD Group showed higher energy and protein intake even though BMI was lower than in Control Group. There were no differences in laboratorial data, except for higher glycemia, serum alkaline phosfatase and C-reactive protein in PD Group. There was no difference in the various parameters evaluated when the Subgroups (PPPD and SPD) were compared. CONCLUSION: For long-term pancreaticoduodenectomy, the gastrointestinal symptoms are minimal and the patients had the clinical and nutritional status preserved, regardless of pylorus preservation.
Resumo:
The aim of this study was to compare time-motion indicators during judo matches performed by athletes from different age groups. The following age groups were analysed: Pre-Juvenile (13-14 years, n=522), Juvenile (15-16 years, n 353); Junior (19 years, n = 349) and Senior (>20 years, n = 587). The time-motion indicators included: Total Combat Time, Standing Combat Time, Displacement Without Contact, Gripping Time, Groundwork Combat Time and Pause Time. Analysis of variance (ANOVA) one-way and the Tukey test, as well as the Kruskal-Wallis test and Mann-Whitney (for non-parametric data), were conducted, using P < 0.05 as significance level. The results showed that all analysed groups obtained a median of 7 (first quantile - 3, third quantile - 12) sequences of combat/pause cycles. In total time of combat, the result was: for Total Combat Time, Standing Combat Time and Gripping Time: Pre-Juvenile and Senior were significantly longer than Juvenile and Junior. Considering Displacement Without Contact, Junior was significantly longer than all other age groups. For Groundwork Combat Time, Senior was significantly longer than all other age groups and Pre-Juvenile was longer than Junior. These results can be used to improve the physiological performance in intermittent practices, as well as technicaltactical training during judo sessions.
Resumo:
Objective: The aim of the present study was to investigate the FHR parameters in term pregnancies complicated by asthma. Study design: prospective cross-sectional study performed between July 2008 and November 2009. Twenty-one singleton pregnancy between 36 and 40 weeks gestation with diagnosis of maternal asthma and no current use of oral corticosteroids were compared with 30 pregnancies without morbidities at the same gestational age. The computerized cardiotocography (System 8002, Sonicaid) was performed and 30 min analysis was studied. Statistical analysis included Student's t-test or Mann-Whitney U test for comparisons between groups. Categorical data were compared using the chi(2)-test or Fisher's exact test. Results: There were no significant differences in FHR parameters analyzed by computerized cardiotocography: basal FHR (p = 0.80), number of accelerations >10 bpm (p = 0.08) or >15 bpm (p = 0.20), duration of high episodes (p = 0.70), duration of low episodes (p = 0.46) and STV (p = 0.66). Asthmatic mothers presented mean number of fetal movement per hour significantly lower than control group (34.6 +/- 28.2 vs. 60.6 +/- 43.1, p = 0.02). Conclusion: Computerized cardiotocography demonstrates no association between the abnormal parameters of FHR and maternal asthma in term pregnancies. Maternal asthma was associated with less fetal movements per hour, suggesting further studies on the counting of fetal movements in pregnant women with asthma.
Resumo:
Increasing age is associated with a reduction in overall heart rate variability as well as changes in complexity of physiologic dynamics. The aim of this study was to verify if the alterations in autonomic modulation of heart rate caused by the aging process could be detected by Shannon entropy (SE), conditional entropy (CE) and symbolic analysis (SA). Complexity analysis was carried out in 44 healthy subjects divided into two groups: old (n = 23, 63 +/- A 3 years) and young group (n = 21, 23 +/- A 2). It was analyzed SE, CE [complexity index (CI) and normalized CI (NCI)] and SA (0V, 1V, 2LV and 2ULV patterns) during short heart period series (200 cardiac beats) derived from ECG recordings during 15 min of rest in a supine position. The sequences characterized by three heart periods with no significant variations (0V), and that with two significant unlike variations (2ULV) reflect changes in sympathetic and vagal modulation, respectively. The unpaired t test (or Mann-Whitney rank sum test when appropriate) was used in the statistical analysis. In the aging process, the distributions of patterns (SE) remain similar to young subjects. However, the regularity is significantly different; the patterns are more repetitive in the old group (a decrease of CI and NCI). The amounts of pattern types are different: 0V is increased and 2LV and 2ULV are reduced in the old group. These differences indicate marked change of autonomic regulation. The CE and SA are feasible techniques to detect alteration in autonomic control of heart rate in the old group.
Resumo:
STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.
Resumo:
OBJECTIVE This study aimed to test the prediction from the Perception and Attention Deficit model of complex visual hallucinations (CVH) that impairments in visual attention and perception are key risk factors for complex hallucinations in eye disease and dementia. METHODS Two studies ran concurrently to investigate the relationship between CVH and impairments in perception (picture naming using the Graded Naming Test) and attention (Stroop task plus a novel Imagery task). The studies were in two populations-older patients with dementia (n = 28) and older people with eye disease (n = 50) with a shared control group (n = 37). The same methodology was used in both studies, and the North East Visual Hallucinations Inventory was used to identify CVH. RESULTS A reliable relationship was found for older patients with dementia between impaired perceptual and attentional performance and CVH. A reliable relationship was not found in the population of people with eye disease. CONCLUSIONS The results add to previous research that object perception and attentional deficits are associated with CVH in dementia, but that risk factors for CVH in eye disease are inconsistent, suggesting that dynamic rather than static impairments in attentional processes may be key in this population.
Resumo:
A problem with a practical application of Varian.s Weak Axiom of Cost Minimization is that an observed violation may be due to random variation in the output quantities produced by firms rather than due to inefficiency on the part of the firm. In this paper, unlike in Varian (1985), the output rather than the input quantities are treated as random and an alternative statistical test of the violation of WACM is proposed. We assume that there is no technical inefficiency and provide a test of the hypothesis that an observed violation of WACM is merely due to random variations in the output levels of the firms being compared.. We suggest an intuitive approach for specifying a value of the variance of the noise term that is needed for the test. The paper includes an illustrative example utilizing a data set relating to a number of U.S. airlines.
Resumo:
Recent theoretical work has examined the spatial distribution of unemployment using the efficiency wage model as the mechanism by which unemployment arises in the urban economy. This paper extends the standard efficiency wage model in order to allow for behavioral substitution between leisure time at home and effort at work. In equilibrium, residing at a location with a long commute affects the time available for leisure at home and therefore affects the trade-off between effort at work and risk of unemployment. This model implies an empirical relationship between expected commutes and labor market outcomes, which is tested using the Public Use Microdata sample of the 2000 U.S. Decennial Census. The empirical results suggest that efficiency wages operate primarily for blue collar workers, i.e. workers who tend to be in occupations that face higher levels of supervision. For this subset of workers, longer commutes imply higher levels of unemployment and higher wages, which are both consistent with shirking and leisure being substitutable.
Resumo:
Communications Based Train Control Systems require high quality radio data communications for train signaling and control. Actually most of these systems use 2.4GHz band with proprietary radio transceivers and leaky feeder as distribution system. All them demand a high QoS radio network to improve the efficiency of railway networks. We present narrow band, broad band and data correlated measurements taken in Madrid underground with a transmission system at 2.4 GHz in a test network of 2 km length in subway tunnels. The architecture proposed has a strong overlap in between cells to improve reliability and QoS. The radio planning of the network is carefully described and modeled with narrow band and broadband measurements and statistics. The result is a network with 99.7% of packets transmitted correctly and average propagation delay of 20ms. These results fulfill the specifications QoS of CBTC systems.
Resumo:
Specific tests to assess reliability of high luminosity AlInGaP LED for outdoor applications are needed. In this paper tests to propose a model involving three parameters: temperature, humidity and current have been carried out. Temperature, humidity and current accelerated model has been proposed to evaluate the reliability of this type of LED. Degradation and catastrophic failure mechanisms have been analyzed. Finally we analyze the effect of serial resistance in power luminosity degradation.