963 resultados para Tunneled central catheter
Resumo:
The aim of the present study was to describe the practice of central venous catheter (CVC) removal and outcomes of catheter-related bloodstream infection (CR-BSI) in adult haematology patients. Patients were identified retrospectively according to diagnosis coding of inpatient episodes and evaluated when, on examination of medical records, there had been evidence of sepsis with strong clinical suspicion that the source was the CVC. Demographic and bacteriological data, as well as therapeutic measures and clinical outcomes, were recorded. One hundred and three patient episodes were evaluated. The most frequent type of CVC was the Hickman catheter and the most frequently isolated pathogen was coagulase-negative staphylococci. Twenty-five percent of episodes were managed with catheter removal. Treatment failure, defined as recurrence of infection within 90 days or mortality attributed to sepsis within 30 days, occurred significantly more frequently in the group managed without catheter removal (52.5% versus 4%, P
Resumo:
RESUMO - Introdução: As Infeções nosocomiais da corrente sanguínea associada a cateter venoso central (INCS-CVC) provocam um aumento das despesas hospitalares, traduzindo num aumento dos dias de internamento, consumo de antibióticos e de meios complementares de diagnóstico e terapêutica (MCDT). O presente estudo pretende avaliar os custos das INCS-CVC nos serviços de internamento do CHLO, no ano de 2012. Metodologia: Realizou-se um estudo retrospetivo de caso-controlo para determinar os custos adicionais inerentes às INCS-CVC. Foram identificados, em 2012, 32 doentes com infeção e 31 sem infeção. Os controlos foram extraídos da população tendo igual grupo diagnóstico Homogéneo (GDH), idade, sexo, serviço e duração de internamento e presença de CVC. As principais fontes de informação foram os registos da Comissão Controlo de Infeção (CCI) e do processo clinico eletrónico (PCE). A estimativa dos custos teve em consideração a duração de internamento, consumo de antibióticos e de MCDT. Resultados: A idade média dos casos e controlos foi de 66 e 69, respetivamente (p=0,432), 50% dos casos e 51,6% dos controlos eram do sexo masculino. Um total de 22 casos foi comparado com 22 controlos. A duração média de internamento dos casos e controlos foi de 70,8 e 36,6 dias, respetivamente (p=0,000). Em média o custo adicional por doente com antibióticos foi de 256€ (p=0,001). Nos casos o consumo de análises clinica foi 2,5 vezes superior e de exames imagiológicos 2 vezes superior aos controlos. O custo total médio adicional por doente foi de 20.737,6€. Conclusão: A ocorrência de INCS-CVC resultou num aumento significativo de utilização de recursos hospitalares e consequentemente num aumento dos custos hospitalares.
Resumo:
Marco conceptual: La enfermedad renal crónica es un serio problema de salud pública en nuestro país por la gran cantidad de recursos económicos que requiere su atención. La hemodiálisis es el tratamiento más usado en nuestro medio; el acceso vascular y sus complicaciones derivadas son el principal aspecto que incrementa los costos de atención en éstos pacientes. Materiales y métodos: Se realizó un estudio económico de los accesos vasculares en pacientes incidentes de hemodiálisis en el año 2012 en la agencia RTS-Fundación Cardio Infantil. Se estableció el costo de creación y mantenimiento del acceso con catéter central, fístula arteriovenosa nativa, fístula arteriovenosa con injerto; y el costo de atención de las complicaciones para cada acceso. Se determinó la probabilidad de ocurrencia de complicaciones. Mediante un árbol de decisiones se trazó el comportamiento de cada acceso en un período de 5 años. Se establecieron los años de vida ajustados por calidad (QALY) en cada acceso y el costo para cada uno de éstos QALY. Resultados: de 36 pacientes incidentes de hemodiálisis en 2012 el 100% inició con catéter central, 16 pacientes cambiaron a fístula arteriovenosa nativa, 1 a fístula arteriovenosa con injerto que posteriormente pasó a CAPD, 15 continuaron su acceso con catéter y 4 pacientes fallecieron. En 5 años se obtuvieron 2,36 QALY para los pacientes con catéter central que costarían $ 24.813.036,39/QALY y 2,535 QALY para los pacientes con fístula nativa que costarían $ 6.634.870,64/QALY. Conclusiones: el presente estudio muestra que el acceso vascular mediante fístula arteriovenosa nativa es el más costo-efectivo que mediante catéter
Resumo:
La infección asociada a inserción de catéter vascular, es un problema cotidiano en las UCI a nivel mundial, a pesar del manejo de protocolos que se han implementado de manera independiente en las distintas instituciones para frenar este fenómeno. El estudio, de tipo observacional, analítico y cohorte concurrente, con 151 pacientes, a los cuales se insertó catéter en la UCI de la Clínica San Pedro Claver.Para el análisis se realizó estadística descriptiva, análisis de sobrevida, pruebas de asociación y regresión de Cox.
Resumo:
Introducción: La utilización de catéteres venosos centrales (CVC) en la unidad de cuidado intensivo tiene gran importancia y amplio uso, son fuente de apoyo para la realización de varia actividades, pero con un gran potencial de complicaciones, por lo cual es fundamental conocer todos los aspectos relacionados con su uso, para así poder controlarlas. Métodos: Realizamos un estudio descriptivo de corte transversal con el objetivo de caracterizar los pacientes que requirieron CVC en el Hospital Universitario Fundación Santa Fe de Bogotá durante junio de 2011 y mayo de 2013, describimos sus complicaciones asociadas tanto mecánicas como infecciosas, determinamos la tasa de bacteriemia, gérmenes causales y sus patrones de resistencia. Resultados: Se colocaron 2.286 CVC, el 52,9% en hombres, la media de edad fue 58,9 años. El total de las complicaciones ascienden al 4,5%, infecciosas 4,0% y mecánicas 0,6%. Dentro de las mecánicas solo encontramos inmediatas, no tardías. Con respecto a las infecciosas encontramos infección del sitio de inserción y bacteriemia. Se documentó una tasa de bacteriemia de 3,4 por 1000-días catéter en 2013, en disminución con respecto a 2012 (3,9) y 2011 (4,4). El microorganismo mas frecuentemente aislado fue el Staphylococcus Coagulasa Negativo con patrón usual de resistencia. Conclusión: Las complicaciones asociadas al uso de CVC en el HUFSFB, se presentan en menor frecuencia a las descritas internacionalmente; la tasa de bacteriemia asociada al CVC ha disminuido año tras año, posiblemente asociado al cuidado mas estricto posterior a la implementación de protocolos de manejo.
Resumo:
O uso de cateteres venosos centrais (CVC) para fins diagnósticos e terapêuticos está incorporado à prática médica diária. Complicações sérias, com elevada morbidade e mortalidade, como a sepse, estão associadas a este procedimento. O diagnóstico das infecções relacionadas a cateter é fundamentado em sinais clínicos e laboratoriais. Os fatores de risco para infecção devem ser considerados por ocasião da utilização de CVC e estão relacionados ao paciente, ao cateter, ao tipo de solução administrada, ao profissional que manipula o cateter e ao agente etiológico. A identificação destes fatores permite a intervenção precoce sobre os mesmos e o manejo adequado do CVC e das complicações clínicas relacionadas.
Resumo:
This is a study descriptive cross-sectional and quantitative approaches, which aimed to analyze the association between hospital infection rate for insertion, maintenance of central venous catheter and the breakdown of protocols (rules and routines) by health professionals assisting patients in the ICU of a university hospital in Natal / RN. The process of data collection was through observation with structured form, refers to medical records and structured questionnaires with health professionals. The results were organized, tabulated, categorized and analyzed using SPSS 14.0. The characterization of the subjects was performed using descriptive and inferential statistics, taking into account the nature of the variables, with analysis of variance (ANOVA) and Spearman correlation test, it was a discussion of the information obtained, considering the mean, standard deviation, coefficient of variance and standard error. The variables that showed a higher level of correlation were treated with the application of significance tests. As the results, 71% of participants were female and 29% male, age ranged from 18 to 85 years (52.6 ± 22.5). The insertion, there was a variation from 0 to 5 errors (1.2 ± 1.4), during maintenance, the average was 2.3 ± 0.9 errors, ranging from 0 to 4. During the insertion and maintenance of CVC, patients who had been an infection ranging from 2 to 9 mistakes (4.2 ± 1.7), since those who did not show the variation goes from 0 to 5 errors (2, 8 ± 1.5). The correlation coefficient between the risk of infection throughout the process and the risk of infection at the insertion showed strong and significant (r = 0.845 p = 0.000) and in relation to risk of infection in maintenance was moderate and significant (r = 0.551 p = 0.001). The mistakes made by professionals in the procedures for insertion and maintenance of the catheter, associated with other conditions, shown as a risk factor for the of IH
Resumo:
Cateteres venosos centrais inseridos em pacientes internados em unidade de terapia intensiva foram avaliados por métodos microbiológicos (cultura semi-quantitativa) e microscopia eletrônica de varredura a fim de detectar adesão microbiana e correlacionar com a cultura de sangue. Durante o período de estudo, foram avaliados 59 pacientes com cateter venoso central. A idade dos pacientes, sexo, sítio de inserção e tempo de permanência do cateter foram anotados. O cateter era de poliuretano não tunelizado e de único lúmen. O sangue para cultura foi coletado no momento da remoção do cateter. de 63 pontas de cateteres, 30 (47,6%) foram colonizadas e a infecção encontrada em 5 (23,8%) cateteres. A infecção foi mais prevalente em 26 pacientes (41,3%) com cateteres inseridos em veia subclávia do que nos 3 (3,2%) inseridos em veia jugular. A infecção foi observada com mais freqüência em cateteres com tempo de permanência maior do que sete dias. Os microrganismos isolados incluíram 32 estafilococos coagulase-negativa (29,7%), 61 bactérias Gram-negativas (52,9%), 9 estafilcocos coagulase-positiva (8,3%) e 3 leveduras (2,7%). Como agentes causais de infecções em unidade de terapia intensiva foram isolados E. aerogenes, P. aeruginosa, A. baumannii. Os antimicrobianos com maior atividade in vitro contra as bactérias Gram-negativas foram o imipenem e contra as Gram-positivas vancomicina, cefepime, penicilina, rifampicina e tetraciclina. As análises por microscopia eletrônica de varredura revelaram biofilmes sobre a superfície de todos os cateteres examinados.
Resumo:
As infecções devido a biofilmes bacterianos são comuns em pacientes sob tratamento em hemodiálise. Neste estudo, 16 pacientes (7 homens, 9 mulheres, de 22 a 81 anos, média 50 anos de idade), com um total de 25 cateteres de hemodiálise (3 de triplo-lúmen e 22 de duplo-lúmen) de poliuretano inseridos em veia subclávia foram estudados. Os cateteres permaneceram no local de 3 a 91 dias (média de 47 dias). Os cateteres foram removidos devido ao: mau funcionamento (44%), suspeita de infecção relacionada ao cateter (20%), viabilidade de um acesso permanente (16%), remoção acidental (12%), sinais e sintomas de infecção no local da inserção do cateter (4%) e contaminação exógena (4%). Culturas positivas de ponta foram observadas em sete cateteres (28%), concomitantemente com três culturas positivas de sangue. Das culturas de sangue foram identificados Staphylococcus aureus (12%) e de uma das conexões foi isolado S. aureus. Biofilmes foram observados sobre todas as pontas de cateteres. Os S. aureus isolados do sangue e cateter (ponta e conexão) eram resistentes a pencilina e sensíveis a azitromicina, ciprofloxacina, clindamicina, cloranfenicol, gentamicina, oxacilina, rifampicina, sulfametoxazole, tetraciclina e vancomicina. As cepas de S. aureus isoladas de sangue, ponta de cateter e conexão foram consideradas idênticas devido à coincidência do perfil de sensibilidade. E similaridade genética, avaliada por meio de ribotipagem.
Resumo:
A total of 63 pregnancies (47 singleton, 15 twin, 1 triplet) from intracytoplasmic sperm injection cycles were analysed. In all embryo transfers, the catheter was introduced into the endometrial cavity guided by abdominal ultrasound, with the catheter tip placed at the middle point of the endometrial cavity. Gestational sacs (GS) were located 21-24 days after transfer (gestational age = 5 weeks) by two-dimensional and three-dimensional transvaginal ultrasound. The uterine cavity was divided into three parts: upper, middle and lower. Furthermore, the upper region was subdivided into right, middle and left areas, and the middle region was subdivided into right and left areas. The frequency of gestational sacs in each area was evaluated. In singleton pregnancies 66.0% (31/47) of the GS were detected in the upper region, 29.8% (14/47) in the middle region and 4.2% (2/47) in the lower region. In multiple pregnancies (twins and triplet) 45.5% (15/33) of the GS were detected in the upper region, 51.5% (17/33) in the middle region and 3.0% (1/33) in the lower region. In conclusion, the results demonstrate that when embryos are transferred to the central area of the uterine cavity there is an increase in implantation rate in the middle region compared with the rate expected in naturally conceived pregnancies (9-15%).
Resumo:
Slime production is an important virulence factor of coagulase-negative Staphylococcus spp., allowing them to attach to smooth surfaces of biomaterials, and it has been associated with infections of implanted medical devices. In the present study the production of slime capsules in 27 strains of coagulase-negative Staphylococcus was investigated by culture in Congo Red agar (77.7% positivity), spectrophotometric or microplate method (81.4% positivity) and scanning electron microscopy (88.9% positivity). The resistance of coagulase-negative strains of Staphylococcus to various antimicrobial agents was also determined by agar disk diffusion. The proportion of strains resistant to penicillin G, oxacillin, erythromycin, clindamycin and gentamicin among the slime-producing staphylococci was 88.9%, 70.4%, 81.5%, 66.7% and 59.2%, respectively; all of the coagulase-negative staphylococci were susceptible to vancomycin. The strains isolated from central venous catheters were identified by a conventional method and the API Staph system. The 27 coagulase-negative Staphylococcus strains were identified as: S. saprophyticus (3.7%), S. xylosus (7.4%), S. haemolyticus (14.8%), S. epidermidis (37.0%), S. warneri (14.8%), S. lugdunensis (7.4%), S. hominis (7.4%), S. schleiferi (3.7%) and S. chromogenes (3.7%). It can be concluded that in the most of the coagulase-negative Staphylococcus species there was an association between slime production, the nosocomial origin of the strains and reduced sensitivity to the antibiotics, suggesting a pathogenic potential in the hospital environment.
Resumo:
Pós-graduação em Pediatria - FMB
Resumo:
Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)