991 resultados para Thickness measurement
Resumo:
A network of twenty stakes was set up on Johnsons Glacier in order to determine its dynamics. During the austral summers from 1994-95 to 1997-98, we estimated surface velocities, mass balances and ice thickness variations. Horizontal velocity increased dow nstream from 1 m a- 1 near the ice divides to 40 m a- 1 near the ice terminus. The accumulation zone showed low accumulation rates (maximum of 0,6 m a- 1 (ice)), whereas in the lower part of the glacier, ablation rates were 4,3 m a- 1 (ice). Over the 3-year study period, both in the accumulation and ablation zones, we detected a reduction in the ice surface level ranging from 2 to 10 m from the annual ve rt ical velocities and ice-thinning data, the mass balance was obtained and compared with the mass balance field values, resulting in similar estimates. Flux values were calculated using cross-section data and horizontal velocities, and compared with the results obtained by means of mass balance and ice thinning data using the continuity equation. The two methods gave similar results.
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
Verenpaineen kotimittaus − epidemiologia ja kliininen käyttö Kohonnutta verenpainetta, maailmanlaajuisesti merkittävintä ennenaikaiselle kuolemalle altistavaa riskitekijää, ei voida tunnistaa tai hoitaa ilman tarkkoja ja käytännöllisiä verenpaineen mittausmenetelmiä. Verenpaineen kotimittaus on saavuttanut suuren suosion potilaiden keskuudessa. Lääkärit eivät ole kuitenkaan vielä täysin hyväksyneet verenpaineen kotimittausta, sillä riittävä todistusaineisto sen toimivuudesta ja eduista on puuttunut. Tämän tutkimuksen tarkoituksena oli osoittaa, että kotona mitattu verenpaine (kotipaine) on perinteistä vastaanotolla mitattua verenpainetta (vastaanottopaine) tarkempi, ja että se on tehokas myös kliinisessä käytössä. Tutkimme kotipaineen käyttöä verenpainetaudin diagnosoinnissa ja hoidossa. Lisäksi tarkastelimme kotipaineen yhteyttä verenpainetaudin aiheuttamiin kohde-elinvaurioihin. Ensimmäinen aineisto, joka oli edustava otos Suomen aikuisväestöstä, koostui 2 120 45–74-vuotiaasta tutkimushenkilöstä. Tutkittavat mittasivat kotipainettaan viikon ajan ja osallistuivat terveystarkastukseen, johon sisältyi kliinisen tutkimuksen ja haastattelun lisäksi sydänfilmin otto ja vastaanottopaineen mittaus. 758 tutkittavalle suoritettiin lisäksi kaulavaltimon seinämän intima-mediakerroksen paksuuden (valtimonkovettumataudin mittari) mittaus ja 237:lle valtimon pulssiaallon nopeuden (valtimojäykkyyden mittari) mittaus. Toisessa aineistossa, joka koostui 98 verenpainetautia sairastavasta potilaasta, hoitoa ohjattiin satunnaistamisesta riippuen joko ambulatorisen eli vuorokausirekisteröinnillä mitatun verenpaineen tai kotipaineen perusteella. Vastaanottopaine oli kotipainetta merkittävästi korkeampi (systolisen/diastolisen paineen keskiarvoero oli 8/3 mmHg) ja yksimielisyys verenpainetaudin diagnoosissa kahden menetelmän välillä oli korkeintaan kohtalainen (75 %). 593 tutkittavasta, joilla oli kohonnut verenpaine vastaanotolla, 38 %:lla oli normaali verenpaine kotona eli ns. valkotakkiverenpaine. Verenpainetauti voidaan siis ylidiagnosoida joka kolmannella potilaalla seulontatilanteessa. Valkotakkiverenpaine oli yhteydessä lievästi kohonneeseen verenpaineeseen, matalaan painoindeksiin ja tupakoimattomuuteen, muttei psykiatriseen sairastavuuteen. Valkotakkiverenpaine ei kuitenkaan vaikuttaisi olevan täysin vaaraton ilmiö ja voi ennustaa tulevaa verenpainetautia, sillä siitä kärsivien sydän- ja verisuonitautien riskitekijäprofiili oli normaalipaineisten ja todellisten verenpainetautisten riskitekijäprofiilien välissä. Kotipaineella oli vastaanottopainetta vahvempi yhteys verenpainetaudin aiheuttamiin kohde-elinvaurioihin (intima-mediakerroksen paksuus, pulssiaallon nopeus ja sydänfilmistä todettu vasemman kammion suureneminen). Kotipaine oli tehokas verenpainetaudin hoidon ohjaaja, sillä kotipaineeseen ja ambulatoriseen paineeseen, jota on pidetty verenpainemittauksen ”kultaisena standardina”, perustuva lääkehoidon ohjaus johti yhtä hyvään verenpaineen hallintaan. Tämän ja aikaisempien tutkimusten tulosten pohjalta voidaan todeta, että verenpaineen kotimittaus on selkeä parannus perinteiseen vastaanotolla tapahtuvaan verenpainemittaukseen verrattuna. Verenpaineen kotimittaus on käytännöllinen, tarkka ja laajasti saatavilla oleva menetelmä, josta voi tulla jopa ensisijainen vaihtoehto verenpainetautia diagnosoitaessa ja hoitaessa. Verenpaineen mittauskäytäntöön tarvitaan muutos, sillä näyttöön perustuvan lääketieteen perusteella vaikuttaa, että vastaanotolla tapahtuvaa verenpainemittausta tulisi käyttää vain seulontatarkoitukseen.
Resumo:
Objective To evaluate the sonographic measurement of subcutaneous and visceral fat in correlation with the grade of hepatic steatosis. Materials and Methods In the period from October 2012 to January 2013, 365 patients were evaluated. The subcutaneous and visceral fat thicknesses were measured with a convex, 3–4 MHz transducer transversely placed 1 cm above the umbilical scar. The distance between the internal aspect of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline was considered for measurement of the visceral fat. Increased liver echogenicity, blurring of vascular margins and increased acoustic attenuation were the parameters considered in the quantification of hepatic steatosis. Results Steatosis was found in 38% of the study sample. In the detection of moderate to severe steatosis, the area under the ROC curve was 0.96 for women and 0.99 for men, indicating cut-off values for visceral fat thickness of 9 cm and 10 cm, respectively. Conclusion The present study evidenced the correlation between steatosis and visceral fat thickness and suggested values for visceral fat thickness to allow the differentiation of normality from risk for steatohepatitis.
Resumo:
Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.
Resumo:
Pulsed electroacoustic (PEA) method is a commonly used non-destructive technique for investigating space charges. It has been developed since early 1980s. These days there is continuing interest for better understanding of the influence of space charge on the reliability of solid electrical insulation under high electric field. The PEA method is widely used for space charge profiling for its robust and relatively inexpensive features. The PEA technique relies on a voltage impulse used to temporarily disturb the space charge equilibrium in a dielectric. The acoustic wave is generated by charge movement in the sample and detected by means of a piezoelectric film. The spatial distribution of the space charge is contained within the detected signal. The principle of such a system is already well established, and several kinds of setups have been constructed for different measurement needs. This thesis presents the design of a PEA measurement system as a systems engineering project. The operating principle and some recent developments are summarised. The steps of electrical and mechanical design of the instrument are discussed. A common procedure for measuring space charges is explained and applied to verify the functionality of the system. The measurement system is provided as an additional basic research tool for the Corporate Research Centre of ABB (China) Ltd. It can be used to characterise flat samples with thickness of 0.2–0.5 mm under DC stress. The spatial resolution of the measurement is 20 μm.
Resumo:
Ultrasonic attenuation coefficient, wave propagation speed and integrated backscatter coefficient (IBC) of human coronary arteries were measured in vitro over the -6 dB frequency bandwidth (36 to 67 MHz) of a focused ultrasound transducer (50 MHz, focal distance 5.7 mm, f/number 1.7). Corrections were made for diffraction effects. Normal and diseased coronary artery sub-samples (N = 38) were obtained from 10 individuals at autopsy. The measured mean ± SD of the wave speed (average over the entire vessel wall thickness) was 1581.04 ± 53.88 m/s. At 50 MHz, the average attenuation coefficient was 4.99 ± 1.33 dB/mm with a frequency dependence term of 1.55 ± 0.18 determined over the 36- to 67-MHz frequency range. The IBC values were: 17.42 ± 13.02 (sr.m)-1 for thickened intima, 11.35 ± 6.54 (sr.m)-1 for fibrotic intima, 39.93 ± 50.95 (sr.m)-1 for plaque, 4.26 ± 2.34 (sr.m)-1 for foam cells, 5.12 ± 5.85 (sr.m)-1 for media and 21.26 ± 31.77 (sr.m)-1 for adventitia layers. The IBC results indicate the possibility for ultrasound characterization of human coronary artery wall tissue layer, including the situations of diseased arteries with the presence of thickened intima, fibrotic intima and plaque. The mean IBC normalized with respect to the mean IBC of the media layer seems promising for use as a parameter to differentiate a plaque or a thickened intima from a fibrotic intima.
Resumo:
Our objective was to study the effect of dorzolamide on corneal hydration in an 18-week controlled experiment using ultrasonic pachymetry. Twenty-eight male rabbits were divided randomly into four groups. The 7 rabbits in each group received eye drops containing either 2% (w/v) dorzolamide or placebo in their right eye, or in their left eye. The 2% dorzolamide rabbits were treated every 8 h. Fellow eyes are defined as eyes which did not receive either dorzolamide or placebo. The study was blind for both the person who applied the drug and the one who performed the pachymetry. The effect of treatments is reported on the basis of the percentage of pachymetric variation compared to the measurement made before drug application. There was no significant difference (P = 0.061) in pachymetric variation between dorzolamide (-4.42 ± 11.71%) and placebo (2.48 ± 9.63%). However, there was a significant difference (P = 0.0034) in pachymetric variation between the dorzolamide fellow eyes (-7.56 ± 10.50%) and the placebo (-4.42 ± 11.71%). In conclusion, dorzolamide did not increase the corneal thickness in rabbits.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Resumo:
Mesospheric temperature inversions are well established observed phenomena, yet their properties remain the subject of ongoing research. Comparisons between Rayleigh-scatter lidar temperature measurements obtained by the University of Western Ontario's Purple Crow Lidar (42.9°N, 81.4°W) and the Canadian Middle Atmosphere Model are used to quantify the statistics of inversions. In both model and measurements, inversions occur most frequently in the winter and exhibit an average amplitude of ∼10 K. The model exhibits virtually no inversions in the summer, while the measurements show a strongly reduced frequency of occurrence with an amplitude about half that in the winter. A simple theory of mesospheric inversions based on wave saturation is developed, with no adjustable parameters. It predicts that the environmental lapse rate must be less than half the adiabatic lapse rate for an inversion to form, and it predicts the ratio of the inversion amplitude and thickness as a function of environmental lapse rate. Comparison of this prediction to the actual amplitude/thickness ratio using the lidar measurements shows good agreement between theory and measurements.
Resumo:
Objectives: Studies of the viscoelastic properties of the vocal folds are normally performed with rheometers that use parallel assigned a fixed value. In tissues subject to variation of thickness plates whose interplate space is usually at between samples, fixed gaps could result in different compressions, compromising the comparison among them. We performed,in experimental study to determine whether different compressions call lead to different results in measurements of dynamic viscosity (DV) of vocal fold samples. Methods: We Measured the DV of vocal fold samples of 10 larynges of cadavers under 3 different compression levels, corresponding to 0.2, 0.5, and 10 N on an 8-mm-diameter parallel-plate rheometer. Results: The DV directly varied with compression. We observed statistically significant differences between the results of 0.2 and 10 N (p = 0.0396) and 0.5 and 10 N (p = 0.0442). Conclusions: The study demonstrated that the level of compression influences the DV measure and Suggests that a defined compression level should be used in rheometric studies of biological tissues.
Resumo:
A quantificação da evaporação do solo é requerida em estudos de balanço hídrico de culturas e em aplicações que visam a aumentar a eficiência do uso da água pelos cultivos. O objetivo deste trabalho foi testar um modelo de microlisímetro (ML) para medir a evaporação do solo em condições irrigada e não irrigada. Os MLs foram construídos utilizando tubos de PVC rígido, medindo 100 mm de diâmetro interno, 150 mm de profundidade e 2,5 mm de espessura da parede. Quatro MLs foram assentados sobre a superfície de dois lisímetros de pesagem de alta precisão conduzidos com solo nu, previamente instalados no Iapar, em Londrina-PR. Os lisímetros tinham dimensões de 1,4 m de largura, 1,9 m de comprimento e 1,3 m de profundidade, e estavam sendo conduzidos com e sem irrigação. A evaporação medida nos MLs (E ML) foi comparada com a medida nos lisímetros (E L), durante quatro períodos do ano. As diferenças entre E ML e E L foram mínimas para condições de baixa e elevada demanda atmosférica, e também para condições de solo irrigado ou não irrigado, indicado que o modelo de ML testado neste trabalho é adequado para medir a evaporação do solo.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents a theoretical analysis of a density measurement cell using an unidimensional model composed by acoustic and electroacoustic transmission lines in order to simulate non-ideal effects. The model is implemented using matrix operations, and is used to design the cell considering its geometry, materials used in sensor assembly, range of liquid sample properties and signal analysis techniques. The sensor performance in non-ideal conditions is studied, considering the thicknesses of adhesive and metallization layers, and the effect of residue of liquid sample which can impregnate on the sample chamber surfaces. These layers are taken into account in the model, and their effects are compensated to reduce the error on density measurement. The results show the contribution of residue layer thickness to density error and its behavior when two signal analysis methods are used. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.