957 resultados para Temperature control


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Uniquely, China employs MgO already contained in cement clinker or as an expansive additive to compensate for the thermal shrinkage of mass concrete, particularly dam concrete, with almost 40 years' experience in both research activities and industrial applications. Compensating shrinkage with expansion produced by MgO has been proved to effectively prevent thermal cracking of mass concrete, and reduce the cost of temperature control measures and speed up the construction process. Moreover, the expansion properties of MgO could be designed flexibly, through adjusting its microstructure by changing the calcination conditions (calcining temperature and residence time). The collective knowledge and experience of MgO expansive cement and concrete is worthy of sharing with relevant engineers and researchers globally but dissemination has been hindered as most of the relevant literature is published in Chinese. This paper reviews the history, state-of-the-art progress and future research needs in the field of MgO expansive cement and concrete. © 2013 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

gamma-Al2O3 films were grown on Si (10 0) substrates using the sources of TMA (AI(CH3)(3)) and O-2 by very low-pressure chemical vapor deposition. The effects of temperature control on the crystalline quality, surface morphology, uniformity and dielectricity were investigated. It has been found that the,gamma-Al2O3 film prepared at a temperature of 1000degreesC has a good crystalline quality, but the surface morphology, uniformity and dielectricity were poor due to the etching reaction between 0, and Si substrate in the initial growth stage. However, under a temperature-varied multi-step process the properties Of gamma-Al2O3 film were improved. The films have a mirror-like surface and the dielectricity was superior to that grown under a single-step process. The uniformity of gamma-Al2O3 films for 2-in epi-wafer was <5%, it is better than that disclosed elsewhere. In order to improve the crystalline quality, the gamma-Al2O3 films were annealed for I h in O-2 atmosphere. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A single longitudinal mode and narrow line width external cavity semiconductor laser is proposed. It is constructed with a semiconductor laser, collimator, a flame grating, and current and temperature control systems. The one facet of semiconductor laser is covered by high transmission film, and another is covered by high reflection film. The flame grating is used as light feedback element to select the mode of the semiconductor laser. The temperature of the constructed external cavity semiconductor laser is stabilized in order of 10(-3)degreesC by temperature control system. The experiments have been carried out and the results obtained-the spectral fine width of this laser is compressed to be less than 1.4MHz from its original line-width of more than 1200GHz and the output stability (including power and mode) is remarkably enhanced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

随着计算机技术、测量技术以及控制技术的高速发展,越来越多的先进设备、技术和方法应用于控制领域中。在这其中,单片微处理器因其性能的日益提高、价格的不断降低、强有力的性价优势而逐渐凸现其重要的核心地位。而基于它的温度控制器对于大型工业工程和日常生活等领域的应用前景也日趋广阔。本智能温控系统将应用于国家大科学工程HIRFL-CSR中,它以新型低功耗单片机MSP430F149作为核心,并配有键盘和数码管显示组成小型操作系统,可实现数据采集、数据显示、键盘输入和自动控制等功能。本系统可以进行现场监控,也可以通过RS-485与上位机的串行通信,使这套系统可以在上位机上设定控制温度和各个控制参数,实现远程对温度的实时监控。相对传统的温度控制器而言,本设计采用了铂电阻温度测量电路,并通过硬件和软件两方面对采集模块进行优化处理以便提高系统精度。最终实现了在O℃~500℃温控范围内采集精度在士1℃范围内。使得整个系统具有精度高、可靠性较好、电路简单、成本低、体积小、生产调试方便等特点。本文从硬件和软件两个方面详细介绍了构成本系统的各个模块的硬件电路设计·实现功能和软件编程思想,并丛温控系统的硬件和软件方面介绍了一些工程上实用的抗干扰措施。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本文研究了用于聚四氟乙烯烧结过程实时控制的模糊群控微机系统的硬件及软件设计。系统的主要优点是低成本,高可靠性,其恒温区控温精度达±1.5℃。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

目的利用单片机技术设计多路温度测控系统,实现多路温度的测量和控制.方法系统以单片机AT89C52为核心,利用多路转换器和新型数字器件MAX6675构成8路K型热电偶温度测量电路,利用D/A转换器AD7528和驱动电路构成输出电路,实现8路一一对应的闭环温度测量控制.系统软件采用PID控制器.结果实践证明,可根据需要增减系统温度信号采样通道的数目,使用软件抗干扰措施,提高了采样数据的可靠性.简化了输入输出硬件结构,使系统具有低成本高速度和较好的测量控制精度.结论多路温度测控系统作为整机适用于现场测量控制应用,也可作为多路温度控制模块应用在体积小、温度测量精度要求较高的大型系统中.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Charts are presented of the seasonal variations in the distribution of four phytoplankton and five zooplankton taxa in the North Atlantic and the North Sea. The main factors determining the seasonal variations appear to be the distribution of the main overwintering stocks, the current system and, in some instances, temperature control of the rate of population increase. Information is presented about the variation with latitude (over the range from 34° N to 65 ° N) of the seasonal regime of the plankton. On the assumption that there is a relationship between nutrient supply and vertical temperature stratification the main features of this variability can be interpreted. In the south (to about 43° N) nutrient limitation plus grazing appear to be dominant, resulting in a bimodal seasonal cycle of phytoplankton. North of about 60° N the system appears to be limited by the size of the phytoplankton stocks being grazed primarily by Calanus Finmarchicus and Euphausiacea. In an extensive zone, from about 44° N to 60° N, it would appear that the spring bloom of phytoplankton is under-exploited by grazing while in summer the zooplankton graze the daily production of the phytoplankton, the stocks of which are probably maintained by in situ nutrient regeneration. The implications, for at least this mid-latitude zone, that rates and fluxes of processes, as opposed to density dependent interactions between stocks, play a major role in the dynamics of the seasonal cycle is consistent with previously reported observations suggesting that physical environmental factors play a major role in determining year-to-year fluctuations in the abundance of the plankton.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Free-ocean CO2 enrichment (FOCE) systems are designed to assess the impact of ocean acidification on biological communities in situ for extended periods of time (weeks to months). They overcome some of the drawbacks of laboratory experiments and field observations by enabling (1) precise control of CO2 enrichment by monitoring pH as an offset of ambient pH, (2) consideration of indirect effects such as those mediated through interspecific relationships and food webs, and (3) relatively long experiments with intact communities. Bringing perturbation experiments from the laboratory to the field is, however, extremely challenging. The main goal of this paper is to provide guidelines on the general design, engineering, and sensor options required to conduct FOCE experiments. Another goal is to introduce xFOCE, a community-led initiative to promote awareness, provide resources for in situ perturbation experiments, and build a user community. Present and existing FOCE systems are briefly described and examples of data collected presented. Future developments are also addressed as it is anticipated that the next generation of FOCE systems will include, in addition to pH, options for oxygen and/or temperature control. FOCE systems should become an important experimental approach for projecting the future response of marine ecosystems to environmental change.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de mestrado, Neurociências, Faculdade de Medicina, Universidade de Lisboa, 2015

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study is to optimize the heat flow through the pultrusion die assembly system on the manufacturing process of a specific glass-fiber reinforced polymer (GFRP) pultrusion profile. The control of heat flow and its distribution through whole die assembly system is of vital importance in optimizing the actual GFRP pultrusion process. Through mathematical modeling of heating-die process, by means of Finite Element Analysis (FEA) program, an optimum heater selection, die position and temperature control was achieved. The thermal environment within the die was critically modeled relative not only to the applied heat sources, but also to the conductive and convective losses, as well as the thermal contribution arising from the exothermic reaction of resin matrix as it cures or polymerizes from the liquid to solid condition. Numerical simulation was validated with basis on thermographic measurements carried out on key points along the die during pultrusion process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Frozen storage characteristics and shelflife vary considerably among species as well as within the species (Powrie, 1973; Fennema. 1973). This can be attributed to the variation in the composition of fish among various species. In certain species like sardines and mackerel. wide seasonal variation in chemical composition occur within the species. These variations affect the quality and shelflife. The nutritional level of water. spawning, method of catching, struggling etc. are found to have profound influence on the condition of the fresh fish. Soon after death the deteriorative changes in fish start due to autolysis and bacterial growth. The rate of these changes depends mainly on temperature. The handling methods have great influence on bacterial contamination. Thus the type oi'handling. temperature control. period of chill storage. processing methods. type of freezing, condition of frozen storage and period of storage affect the quality and shelflife Of the fisho In the present study extensive investigations were carried out on various factors affecting the quality of fish as well as their effect on the physical. chemical and sensory qualities of fish during frozen storage and the shelflife

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: La hipotermia perioperatoria se ha documentado como factor de riesgo para el aumento de la morbimortalidad de los pacientes aumentando morbilidad miocárdica, riesgo de infección, pérdidas sanguíneas y tiempo de hospitalización. La aplicación de anestésicos toma relevancia ya que causa la pérdida de control central de la temperatura. Nuestro objetivo con este estudio fue describir la proporción de casos de hipotermia en la población sometida a un reemplazo articular durante un periodo de cuatro meses. Materiales y métodos: Se realizó un estudio de cohorte prospectivo. La población a estudio fueron los pacientes que fueron sometidos a un reemplazo total de cadera, rodilla u hombro. Se registró la temperatura central en el momento previo a la inducción anestésica, 30, 60 y 90 minutos después, al finalizar el procedimiento y al ingresar a recuperación. Se reportó el porcentaje de pacientes con hipotermia en cada tiempo. Resultados: Se analizaron en total 88 pacientes, el 55,7% fue llevado a cirugía de cadera, 39,7% de rodilla y 4,5% de hombro. El tipo de anestesia más utilizado fue general y la duración promedio de anestesia fue 164 minutos. La medición de la temperatura central se realizó en nasofaringe, esófago o tímpano. La proporción de pacientes que presentaron hipotermia en la inducción fue 21,6%, a 30 minutos 83%, a 60 minutos 73,9%, a 90 minutos 68,2%, al finalizar 59,1% y en recuperación 58%. Se realizó una prueba Chi cuadrado comparando las proporciones entre la inducción y los cinco periodos posteriores, se encontró que la proporción de pacientes con hipotermia en los cinco tiempos posteriores tuvo una diferencia estadísticamente significativa (p=0,00) comparada con la proporción de pacientes con hipotermia durante la inducción. Conclusión: En los pacientes sometidos a un reemplazo articular la hipotermia fue una condición prevalente posterior a la aplicación de los anestésicos sistémicos. Los dispositivos de calentamiento intraoperatorio usados actualmente son insuficientes para evitar la hipotermia, lo que indica concordancia con la literatura en cuanto a las recomendaciones de calentamiento perioperatorio, con énfasis en el precalentamiento, para prevenir la caída significativa de la temperatura y la morbimortalidad asociada.