108 resultados para TNT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We estimated the detonation depth and net explosive weight for a very shallow underwater explosion using cutoff frequencies and spectral analysis. With detonation depth and a bubble pulse the net explosive weight for a shallow underwater explosion could simply be determined. The ray trace modeling confirms the detonation depth as a source of the hydroacoustic wave propagation in a shallow channel. We found cutoff frequencies of the reflection off the ocean bottom to be 8.5 Hz, 25 Hz, and 43 Hz while the cutoff frequency of the reflection off the free surface to be 45 Hz including 1.01 Hz for the bubble pulse, and also found the cutoff frequency of surface reflection to well fit the ray-trace modeling. We also attempted to corroborate our findings using a 3D bubble shape modeling and boundary element method. Our findings led us to the net explosive weight of the underwater explosion offshore of Baengnyeong-do for the ROKS Cheonan sinking to be approximately 136 kg TNT at a depth of about 8 m within an ocean depth of around 44 m. © 2015 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado, Neurociências Cognitivas e Neuropsicologia, Faculdade de Ciências Humanas e Sociais, Universidade do Algarve, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel reusable molecularly imprinted polymer (MIP) assembled on a polymeric layer of carboxylated poly(vinyl chloride) (PVCsingle bondCOOH) for myoglobin (Myo) detection was developed. This polymer was casted on the gold working area of a screen printed electrode (Au-SPE), creating a novel disposable device relying on plastic antibodies. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FTIR) studies confirmed the surface modification. The MIP/Au-SPE devices displayed a linear behaviour in EIS from 0.852 to 4.26 μg mL−1, of positive slope 6.50 ± 1.48 (kΩ mL μg−1). The limit of detection was 2.25 μg mL−1. Square wave voltammetric (SWV) assays were made in parallel and showed linear responses between 1.1 and 2.98 μg mL−1. A current decrease was observed against Myo concentration, producing average slopes of −0.28 ± 0.038 μA mL μg−1. MIP/Au-SPE also showed good results in terms of selectivity. The error% found for each interfering species were 7% for troponin T (TnT), 11% for bovine serum albumin (BSA) and 2% for creatine kinase MB (CKMB), respectively. Overall, the technical modification over the Au-SPE was found a suitable approach for screening Myo in biological fluids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’optimisation de l’exercice par intervalles de haute intensité (EIHI) chez les patients insuffisants cardiaques (IC) n’a jamais été étudiée auparavant. Nous avons comparé les réponses cardio-pulmonaires aiguës lors de 4 différents EIHI dans le but de trouver le protocole optimisé chez les patients IC. Les patients IC étaient aléatoirement alloués à 4 sessions d’EIHI. Chaque phase d’exercice était à une intensité de 100% de la puissance aérobie maximale (PAM), mais de différentes durées (30s ou 90s) et de type de récupération (passive ou active). Chaque protocole d’EIHI durait un maximum de 30 minutes ou jusqu’à épuisement. Considérant le temps total d’exercice, l’adhérence, une perception d’effort moins élevée, le confort du patient ainsi que des temps similaires passés à un haut pourcentage du VO2pic, le mode avec intervalles courts (30s) et récupération passive s’est avéré être le protocole d’EIHI optimisé chez ces patients. Suite à cette étude, nous avons voulu comparer les réponses cardio-pulmonaires aiguës d’un exercice continu d’intensité modéré (ECIM) par rapport à celles de l’EIHI optimisé de dépense énergétique équivalente chez les patients IC. L’objectif de cette étude était de comparer les réponses cardio-pulmonaires, l’adhérence, la perception de l’effort, l’inflammation et les biomarqueurs cardiaques. Comparativement à l’ECIM, l’adhérence, l’efficience et la tolérance étaient plus élevées lors de l’EIHI optimisé chez les patients IC tout en produisant un stimulus physiologique important. L’EIHI n’a causé aucune arythmie significative ou d’effets délétères sur l’inflammation (CRP), le BNP et la nécrose myocardique (C-TnT) chez les patients IC. L’EIHI semble être un mode d’exercice prometteur et devrait être considéré lors de la réadaptation cardiaque chez les patients IC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hazards associated with major accident hazard (MAH) industries are fire, explosion and toxic gas releases. Of these, toxic gas release is the worst as it has the potential to cause extensive fatalities. Qualitative and quantitative hazard analyses are essential for the identitication and quantification of the hazards associated with chemical industries. This research work presents the results of a consequence analysis carried out to assess the damage potential of the hazardous material storages in an industrial area of central Kerala, India. A survey carried out in the major accident hazard (MAH) units in the industrial belt revealed that the major hazardous chemicals stored by the various industrial units are ammonia, chlorine, benzene, naphtha, cyclohexane, cyclohexanone and LPG. The damage potential of the above chemicals is assessed using consequence modelling. Modelling of pool fires for naphtha, cyclohexane, cyclohexanone, benzene and ammonia are carried out using TNO model. Vapor cloud explosion (VCE) modelling of LPG, cyclohexane and benzene are carried out using TNT equivalent model. Boiling liquid expanding vapor explosion (BLEVE) modelling of LPG is also carried out. Dispersion modelling of toxic chemicals like chlorine, ammonia and benzene is carried out using the ALOHA air quality model. Threat zones for different hazardous storages are estimated based on the consequence modelling. The distance covered by the threat zone was found to be maximum for chlorine release from a chlor-alkali industry located in the area. The results of consequence modelling are useful for the estimation of individual risk and societal risk in the above industrial area.Vulnerability assessment is carried out using probit functions for toxic, thermal and pressure loads. Individual and societal risks are also estimated at different locations. Mapping of threat zones due to different incident outcome cases from different MAH industries is done with the help of Are GIS.Fault Tree Analysis (FTA) is an established technique for hazard evaluation. This technique has the advantage of being both qualitative and quantitative, if the probabilities and frequencies of the basic events are known. However it is often difficult to estimate precisely the failure probability of the components due to insufficient data or vague characteristics of the basic event. It has been reported that availability of the failure probability data pertaining to local conditions is surprisingly limited in India. This thesis outlines the generation of failure probability values of the basic events that lead to the release of chlorine from the storage and filling facility of a major chlor-alkali industry located in the area using expert elicitation and proven fuzzy logic. Sensitivity analysis has been done to evaluate the percentage contribution of each basic event that could lead to chlorine release. Two dimensional fuzzy fault tree analysis (TDFFTA) has been proposed for balancing the hesitation factor invo1ved in expert elicitation .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study envisaged herein contains the numerical investigations on Perforated Plate (PP) as well as numerical and experimental investigations on Perforated Plate with Lining (PPL) which has a variety of applications in underwater engineering especially related to defence applications. Finite element method has been adopted as the tool for analysis of PP and PPL. The commercial software ANSYS has been used for static and free vibration response evaluation, whereas ANSYS LS-DYNA has been used for shock analysis. SHELL63, SHELL93, SOLID45, SOLSH190, BEAM188 and FLUID30 finite elements available in the ANSYS library as well as SHELL193 and SOLID194 available in the ANSYS LS-DYNA library have been made use of. Unit cell of the PP and PPL which is a miniature of the original plate with 16 perforations have been used. Based upon the convergence characteristics, the utility of SHELL63 element for the analysis of PP and PPL, and the required mesh density are brought out. The effect of perforation, geometry and orientation of perforation, boundary conditions and lining plate are investigated for various configurations. Stress concentration and deflection factor are also studied. Based on these investigations, stadium geometry perforation with horizontal orientation is recommended for further analysis.Linear and nonlinear static analysis of PP and PPL subjected to unit normal pressure has been carried out besides the free vibration analysis. Shock analysis has also been carried out on these structural components. The analytical model measures 0.9m x 0.9m with stiffener of 0.3m interval. The influence of finite element, boundary conditions, and lining plate on linear static response has been estimated and presented. Comparison of behavior of PP and PPL in the nonlinear strain regime has been made using geometric nonlinear analysis. Free vibration analysis of the PP and PPL has been carried out ‘in vacuum’ condition and in water backed condition, and the influence of water backed condition and effect of perforation on natural frequency have been investigated.Based upon the studies on the vibration characteristics of NPP, PP and PPL in water backed condition and ‘in vacuum’ condition, the reduction in the natural frequency of the plate in immersed condition has been rightly brought out. The necessity to introduce the effect of water medium in the analysis of water backed underwater structure has been highlighted.Shock analysis of PP and PPL for three explosives viz., PEK, TNT and C4 has been carried out and deflection and stresses on plate as well as free field pressure have been estimated using ANSYS LS-DYNA. The effect of perforations and the effect of lining plate have been predicted. Experimental investigations of the measurement of free field pressure using PPL have been conducted in a shock tank. Free field pressure has been measured and has been validated with finite element analysis results. Besides, an experiment has been carried out on PPL, for the comparison of the static deflection predicted by finite element analysis.The distribution of the free field pressure and the estimation of differential pressure from experimentation and the provision for treating the differential pressure as the resistance, as a part of the design load for PPL, has been brought out.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Des del descobriment del buckminster ful.lerè el 1985, s'ha despertat un interés enorme per entendre la reactivitat química així com les propietats d'aquests compostos. La funcionalització exoèdrica del ful.lerè més abundant, el C60, està força ben establerta. Tanmateix, la investigació en aquest camp encara continua oberta ja que s'han sintetitzat una gran varietat de derivats molt prometedors donades les seves futures aplicacions. La tesi comprèn quinze capítols que contenen set publicacions relacionades. Els primers dos estudis es basen en la reacció Diels-Alder sobre els anomenats metal.loful.lerens endoèdrics TNT X3N@C78, X= Sc, Y. Aquest projecte de investigació està motivat pel desconeixament existent sobre les possibles conseqüències de l'encapsulació del grup X3N. El tercer estudi descriu minuciosament els canvis detectats en la funcionalització exoèdrica un cop s'ha produït l'encapsulació dels diferents gasos nobles. En aquesta tesi s'estudia en detall l'ús de l'aproximació ONIOM per a estudiar reaccions de cicloaddició en compostos ful.lerènics. Els resultats d'aquest projecte són d'alt interès per a la realització dels estudis posteriors sobre la reacció de Diels-Alder i la 1,3-dipolar en ful.lerens i derivats. Finalment, l'última part d'aquesta tesi es basa en les propietats antioxidants de determinats ful.lerens. A l'últim treball inclòs en aquesta tesi s'estudia en detall el mecanismo de reacció per a la eliminació del ió superòxid en presència de ful.lerens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel, pyrene-functionalised copolymer has been synthesised in a single step via imidisation of poly(maleic anhydride-alt-1-octadecene) with 1-pyrenemethylamine, and its potential for the detection of volatile nitro aromatic compounds (NACs) evaluated. The new copolymer forms complexes in solution with NACs such as 2,5-dinitrobenzonitrile, as shown by H-1 NMR, UV-vis and fluorescence spectroscopy. Moreover, thin films of this copolymer, cast from THF solution, undergo almost instantaneous fluorescence quenching when exposed to the vapour of 2,5-dinitrobenzonitrile (a model for TNT) at ambient temperatures and pressures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: Estudos sobre implicações clínicas da nova definição de infarto do miocárdio (IAM), incorporando novos marcadores de lesão miocárdica, são escassos na literatura. A prevalência de IAM e das suas complicações são diretamente dependentes do critério diagnóstico utilizado. Objetivo: Avaliar o impacto diagnóstico, prognóstico e econômico da nova definição de IAM proposta pela AHA/ ESC usando troponina T (TnT) como marcador de lesão cardíaca. Métodos: Um total de 740 pacientes com dor torácica admitidos na Emergência do Hospital de Clínicas de Porto Alegre no período de julho/ 1999 a janeiro/ 2002 foram incluídos no estudo. Creatina quinase total (CK), CK-MB atividade e TnT foram dosados em uma amostra de 363 pacientes, representativa de toda a coorte. Para redefinição de IAM foram utilizados como ponto de corte valores pico de TnT > 0,2 mg/dl. Os desfechos avaliados foram classificados como eventos cardíacos maiores (angina recorrente, insuficiência cardíaca congestiva, choque cardiogênico e óbito) e como procedimentos de revascularização. Também foram avaliados o manejo prescrito, os custos e o faturamento hospitalar. Resultados: Nos 363 pacientes com marcadores dosados, foram diagnosticados 59 casos de IAM (16%) pelos critérios clássicos; enquanto 40 pacientes (11%) tiveram o diagnóstico de IAM pelo critério redefinido, o que corresponde a um incremento de 71% na incidência. Pacientes com IAM redefinido eram significativamente mais idosos e do sexo masculino, apresentaram mais dor atípica e diabetes mellitus. Na análise multivariada, pacientes com infarto redefinido tiveram um risco 5,1 [IC 95% 1,0-28] vezes maior para óbito hospitalar e 3,4 [IC 95% 1,1-10] vezes maior para eventos combinados em relação aqueles sem IAM. O manejo dos casos de IAM redefinido foi semelhante ao manejo daqueles com IAM tradicional, exceto pelos procedimentos de revascularização que foram menos freqüentes (25% vs. 51%, P < 0,001). O grupo com IAM redefinido permaneceu mais tempo internado e foi submetido a procedimentos mais tardiamente. Do ponto de vista institucional, o uso dos novos critérios para IAM poderia resultar em um aumento de 9% (mais R$ 2.756,00 por grupo de 100 pacientes avaliados) no faturamento baseado em diagnóstico segundo a tabela do SUS. Conclusões: O novo diagnóstico de IAM acrescenta um número expressivo de indivíduos com infarto aos serviços de emergência. A incorporação deste critério é importante na medida que estes pacientes têm um prognóstico semelhante aos demais casos tradicionalmente diagnosticados. Como a identificação destes casos poderia resultar em um manejo mais qualificado e eficiente destes pacientes, esforços deveriam ser adotados para reforçar a adoção da redefinição de IAM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, it has been investigated the influence of silver film deposition onto 100% polyester woven and non-woven, on the survival of Escherichia coli and Staphylococcus aureus in contact with these surfaces. The treatment was performedin a chamber containing the working gas at low pressure (~ 10-2 mbar). Some process parameters such as as voltage: 470 V; pressure: 10-2 mbar; current : 0.40 A and gas flow: 6 and 10 cm3/min were kept constant. For the treatments with purêargon plasma using a flow of 6 and 10 cm3/min, different treatment times were evaluated, such as, 10 , 20, 30, 40, 50 and 60 minutes. Contact angle (sessile drop), measurements were used to determine the surface tension of the treated fabrics and its influence on the bacteria grow as weel as the possibilities of a biofilm formation. The formation of a silver film, as well as the amount of this element was verified byEDX technique. The topography was observed through scanning electron microscopy (SEM) to determine the size of silver grains formed on the surfaces of the fabric and assess homogeneity of treatment. The X-ray diffraction (XRD) was used to analyze the structure of silver film deposition. The woven fabric treatments enabled the formation of silver particulate films with particle size larger than the non-woven fabrics. With respect to bacterial growth, all fabrics were shown to be bactericidal for Staphylococcus aureus (S. aureus), while for the Escherichia coli (E. coli), the best results were found for the non-woven fabric (TNT) treated with a flow of 10 cm3/min to both bacteria

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho foi realizado em um pomar comercial de pêssego da cultivar Aurora 2, de três anos de idade, conduzida em sistema de vaso moderno e espaçamento de 6 x 4 m. O delineamento experimental foi em blocos casualizados, utilizando-se de 15 tratamentos, 8 repetições e 16 frutos por tratamento. Os tratamentos foram os seguintes: T1 - Sacolas de TNT branco de 45 gramaturas por m² (45G/m², fechado; T2 - Sacolas de TNT branco de 45 gramaturas por m² (45G/m²) aberto; T3 - Sacolas de TNT branco de 20 gramaturas por m² (20G/m²) fechado; T4 - Sacolas de TNT branco de 20 gramaturas por m² (20G/m²) aberto; T5 - Sacolas de polipropileno microperfurado transparente (furos de 1mm) fechado; T6 - Sacolas de polipropileno microperfurado transparente (furos de 1mm) aberto; T7 - Sacolas de polipropileno microperfurado transparente (furos de 2mm) fechado; T8 - Sacolas de polipropileno microperfurado transparente (furos de 2mm) aberto; T9 - Sacolas de polietileno microperfurado leitoso (furos de 1mm) fechado; T10 Sacolas de polietileno microperfurado leitoso (furos de 1mm) aberto; T11 Sacolas de polietileno microperfurado leitoso (furos de 2mm) fechado; T12 - Sacolas de polietileno microperfurado leitoso (furos de 2mm) aberto; T13 - Sacolas de papel impermeável fechado; T14 - Sacolas de papel impermeável aberto; T15 - Testemunha (sem ensacamento). As sacolas de TNT (Tecido-não-Tecido) e as de papel impermeável tinham as dimensões de 11,5 x 15,0 cm, e as de polipropileno microperfurado, de 13,0 x 20,0 cm. Os resultados obtidos permitiram concluir que as embalagens de polipropileno transparentes podem ser empregadas para o ensacamento de frutos de pessegueiro, uma vez que as mesmas possibilitam a visualização da coloração dos frutos no momento da colheita, não comprometem o desenvolvimento da coloração dos mesmos e apresentam facilidade no manuseio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se, no trabalho, buscar opções ao ensacamento de pêssegos, visando o controle eficiente das principais pragas do pessegueiro. Para isso, instalou-se um experimento em um pomar comercial de pêssego do cultivar Aurora 2, conduzido em sistema de vaso e espaçamento de 6 x 4 m. Os tratamentos foram os seguintes: T1 - Sacolas de TNT branco (45 g/m²) fechado, T2 - Sacolas de TNT branco (45 g/m²) aberto, T3 - Sacolas de TNT branco (20 g/m²) fechado; T4 - Sacolas de TNT branco (20 g/m²) aberto; T5 - Sacolas de polipropileno microperfurado transparente (furos de 1mm) fechado; T6 - Sacolas de polipropileno microperfurado transparente (furos de 1mm) aberto; T7 - Sacolas de polipropileno microperfurado transparente (furos de 2mm) fechado; T8 - Sacolas de polipropileno microperfurado transparente (furos de 2mm) aberto; T9 - Sacolas de polietileno microperfurado leitoso (furos de 1mm) fechado; T10 - Sacolas de polietileno microperfurado leitoso (furos de 1mm) aberto; T11 - Sacolas de polietileno microperfurado leitoso (furos de 2mm) fechado; T12 - Sacolas de polietileno microperfurado leitoso (furos de 2mm) aberto; T13 - Sacolas de papel impermeável fechado; T14 - Sacolas de papel impermeável aberto; T15 - Testemunha (sem ensacamento). de acordo com os resultados concluiu-se que todas as embalagens foram eficientes no controle de moscas-das-frutas e pássaros, porém não para mariposa oriental. As sacolas com abertura no fundo podem ser utilizadas como opção ao ensacamento de pêssegos.