895 resultados para System failures (Engineering) -- Location
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
Chiefly tables.
Resumo:
Location information is commonly used in context-aware applications and pervasive systems. These applications and systems may require knowledge, of the location of users, devices and services. This paper presents a location management system able to gather, process and manage location information from a variety of physical and virtual location sensors. The system scales to the complexity of context-aware applications, to a variety of types and large number of location sensors and clients, and to geographical size of the system. The proposed location management system provides conflict resolution of location information and mechanisms to ensure privacy.
Resumo:
* The research work reviewed in this paper has been carried out in the context of the Russian Foundation for Basic Research funded project “Adaptable Intelligent Interfaces Research and Development for Distance Learning Systems”(grant N 02-01-81019). The authors wish to acknowledge the co-operation with the Byelorussian partners of this project.
Resumo:
The maintenance of systems and equipment is a central question related to Production Engineering. Although systems are not fully reliable, it is often necessary to minimize the failure occurrence likelihood. The failures occurrences can have disastrous consequences during a plane flight or operation of a nuclear power plant. The elaboration of a maintenance plan has as objective the prevention and recovery from system failures, increasing reliability and reducing the cost of unplanned shutdowns. It is also important to consider the issues related to organizations safety, especially those dealing with dangerous technologies. The objective of this thesis is to propose a method for maintenance analysis of a nuclear research reactor, using a socio-technical approach, and focused on existing conditions in Brazil. The research reactor studied belongs to the federal government and it is located in the city of Rio de Janeiro. The specific objective of this thesis is to develop the availability analysis of one of the principal systems of the research reactor, the nuclear instrumentation system. In this analysis, were taken into account not only the technical aspects of the modules related to nuclear instrumentation system, but also the human and organizational factors that could affect the availability of the nuclear instrumentation system. The results showed the influence of these factors on the availability of the nuclear instrumentation system.
Resumo:
This study aimed to develop a device to measure RR intervals, which have high correlation with the values of the gold standard device of electrocardiograph (ECG), by the time domain and frequency domain indices. To this end, a study was conducted with 18 students of Jiu-Jitsu, males with 35.5 ± 8.6 years, at least a weekly frequency of 3 times and one year training. The location was at the academy Gracie Barra de Curitiba PR. They underwent an examination at rest for a period of 7 minutes and then the results were converted into heart rate variability (HRV) and analyzed by the indexes in the time domain and the frequency domain. The results were compared statistically using the Pearson test and intraclass correlation (ICC) and according to them proves to be viable the development of this equipment, which is highly correlated and excellent reproducibility for measuring the RR intervals.
Resumo:
This paper presents an experimental study on the evolution of carrot properties along convective drying by hot air at different temperatures (50ºC, 60ºC and 70ºC). The thermo-physical properties calculated were: specific heat, thermal conductivity, diffusivity, enthalpy, heat and mass transfer coefficients. Furthermore, the data of drying kinetics were treated and adjusted according to the three empirical models: Page, Henderson & Pabis and Logarithmic. The sorption isotherms were also determined and fitted using the GAB model. The results showed that, generally, the thermo-physical properties presented a decline during the drying process, and the decrease was faster for the temperature of 70ºC. It was possible to verify that the Page model presented the best prediction ability for the representation of kinetics of the drying process. The GAB model used to fit the sorption isotherms showed a good prediction capacity and, at a given water activity, despite some variations, the amount of water sorbed increased with the decrease of drying temperature.
Resumo:
The productivity associated with commonly available disassembly methods today seldomly makes disassembly the preferred end-of-life solution for massive take back product streams. Systematic reuse of parts or components, or recycling of pure material fractions are often not achievable in an economically sustainable way. In this paper a case-based review of current disassembly practices is used to analyse the factors influencing disassembly feasibility. Data mining techniques were used to identify major factors influencing the profitability of disassembly operations. Case characteristics such as involvement of the product manufacturer in the end-of-life treatment and continuous ownership are some of the important dimensions. Economic models demonstrate that the efficiency of disassembly operations should be increased an order of magnitude to assure the competitiveness of ecologically preferred, disassembly oriented end-of-life scenarios for large waste of electric and electronic equipment (WEEE) streams. Technological means available to increase the productivity of the disassembly operations are summarized. Automated disassembly techniques can contribute to the robustness of the process, but do not allow to overcome the efficiency gap if not combined with appropriate product design measures. Innovative, reversible joints, collectively activated by external trigger signals, form a promising approach to low cost, mass disassembly in this context. A short overview of the state-of-the-art in the development of such self-disassembling joints is included. (c) 2008 CIRP.
Resumo:
Aquatic humic substances (AHS) isolated from two characteristic seasons of the Negro river, winter and summer corresponding to floody and dry periods, were structurally characterized by (13)C nuclear magnetic ressonance. Subsequently, AHS aqueous solutions were irradiated with a polychromatic lamp (290-475 nm) and monitored by its total organic carbon (TOC) content, ultraviolet-visible (UV-vis) absorbance, fluorescence and Fourier transformed infrared spectroscopy (FTIR). As a result, a photobleaching upto 80% after irradiation of 48 h was observed. Conformational rearrangements and formation of low molecular complexity structures were formed during the irradiation, as deduced from the pH decrement and the fluorescence shifting to lower wavelengths. Additionally a significant mineralization with the formation Of CO(2), CO, and inorganic carbon compounds was registered, as assumed by TOC losses of up to 70%. The differences in photodegradation between samples expressed by photobleaching efficiency were enhanced in the summer sample and related to its elevated aromatic content. Aromatic structures are assumed to have high autosensitization capacity effects mediated by the free radical generation from quinone and phenolic moieties.
Resumo:
This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This study presents the results of Raman spectroscopy applied to the classification of arterial tissue based on a simplified model using basal morphological and biochemical information extracted from the Raman spectra of arteries. The Raman spectrograph uses an 830-nm diode laser, imaging spectrograph, and a CCD camera. A total of 111 Raman spectra from arterial fragments were used to develop the model, and those spectra were compared to the spectra of collagen, fat cells, smooth muscle cells, calcification, and cholesterol in a linear fit model. Non-atherosclerotic (NA), fatty and fibrous-fatty atherosclerotic plaques (A) and calcified (C) arteries exhibited different spectral signatures related to different morphological structures presented in each tissue type. Discriminant analysis based on Mahalanobis distance was employed to classify the tissue type with respect to the relative intensity of each compound. This model was subsequently tested prospectively in a set of 55 spectra. The simplified diagnostic model showed that cholesterol, collagen, and adipocytes were the tissue constituents that gave the best classification capability and that those changes were correlated to histopathology. The simplified model, using spectra obtained from a few tissue morphological and biochemical constituents, showed feasibility by using a small amount of variables, easily extracted from gross samples.
Resumo:
The objective of this study was to evaluate in vitro light activation of the nano-filled resin composite Vita shade A1 and A3 with a halogen lamp (QTH) and argon ion laser by Knoop microhardness profile. Materials and methods: Specimens of nanofilled composite resin (Z350-3 M-ESPE) Vita shade A1 and A3 were prepared with a single increment inserted in 2.0-mm-thick and 3-mm diameter disc-shaped Teflon mold. The light activation was performed with QTH for 20 s (with an intensity of approximately 1,000 mW/cm(2) and 700 mW/cm(2)) and argon ion laser for 10 s (with a power of 150 mW and 200 mW). Knoop microhardness test was performed after 24 h and 6 months. The specimens were divided into the 16 experimental groups (n = 10), according to the factors under study: photoactivation form, resin shade, and storage time. Knoop microhardness data was analyzed by a factorial ANOVA and TukeyA ` s tests at the 0.05 level of significance. Results: Argon ion laser was not able to photo-activate the darker shade of the nanofilled resin composite evaluated but when used with 200 mW it can be as effective as QTH to photo-activate the lighter shade with only 50% of the time exposure. After 6 months storage, an increase in the means of Knoop microhardness values were observed. Conclusions: Light-activation significantly influenced the Knoop microhardness values for the darker nanofilled resin composite.
Resumo:
The Commission on Patient Safety and Quality Assurance was established in January 2007 and reported to the Minister in July 2008. The report was considered by government in January 2009 which agreed the implementation process. The overall objective of the Commission was to develop clear and practical recommendations to ensure that safety and quality of care for patients is paramount within the healthcare system. The Commission’s report set out a wide range of policy measures that will drive the safety and quality agenda in Irish healthcare in the coming years. The establishment of the Commission was prompted by an increasing awareness of patient safety issues in general and high profile health service system failures at home and abroad and in particular by the Lourdes Hospital Inquiry. These have underlined the need for an increased focus on patient safety and quality. Download document here Download summary document on the Report
Resumo:
FacturaCloud és un disseny de un sistema de facturació al núvol.
Resumo:
Työn tavoitteena oli kasvattaa sahan dimensiolaitoksella käytettävän trimmerin rakenteellista kapasiteettia. Tavoitteeseen pyrittiin modernisoimalla trimmerin teräyksikköä käyttävää toimilaite ja teräyksikön säätö dynamiikan mallinnuksen avulla. Trimmerin teräyksikön dynamiikka mallinnettiin MATLAB-matematiikkaohjelmistolla kaksiulotteisena kinematiikkamallina ja kolmeulotteisena kinetiikkamallina. Dynamiikkamallien tulosten perusteella valittin teräyksikköä käyttävä toimilaite komponentteineen. Kinetiikkamalliin mallinnettiin trimmeriä käyttävä hydraulipiiri valittuine komponentteineen keskittyneiden paineiden ja puoliempiirisen mallinnuksen periaatteita käyttäen. Teräyksikön työkiertoa säätämään mallinnettiin suljettu takaisinkytketty säätöpiiri. Tuloksien perusteella valittiin optimaalinen toimilaitteen asemointigeometria ja todettiin mallinnetun järjestelmän täyttävän asetetut vaatimukset. Järjestelmää testattiin muuttamalla jarjestelman parametreja ja tutkimalla muutosten vaikutuksia jarjestelman toimintaan. Lisaksi tutkittiin lyhyesti terayksikon rakenteen keventamisen vaikutuksia.