848 resultados para Standard fire curve
Resumo:
Flavanones (hesperidin, naringenin, naringin, and poncirin) in industrial, hand-squeezed orange juices and from fresh-in-squeeze machines orange juices were determined by HPLC/DAD analysis using a previously described liquid-liquid extraction method. Method validation including the accuracy was performed by using recovery tests. Samples (36) collected from different Brazilian locations and brands were analyzed. Concentrations were determined using an external standard curve. The limits of detection (LOD) and the limits of quantification (LOQ) calculated were 0.0037, 1.87, 0.0147, and 0.0066 mg 100 g(-1) and 0.0089, 7.84, 0.0302, and 0.0200 mg 100 g(-1) for naringin, hesperidin, poncirin, and naringenin, respectively. The results demonstrated that hesperidin was present at the highest concentration levels, especially in the industrial orange juices. Its average content and concentration range were 69.85 and 18.80-139.00 mg 100 g(-1). The other flavanones showed the lowest concentration levels. The average contents and concentration ranges found were 0.019, 0.01-0.30, and 0.12 and 0.1-0.17, 0.13, and 0.01-0.36 mg 100 g(-1), respectively. The results were also evaluated using the principal component analysis (PCA) multivariate analysis technique which showed that poncirin, naringenin, and naringin were the principal elements that contributed to the variability in the sample concentrations.
A Feasibility Study Of Fricke Dosimetry As An Absorbed Dose To Water Standard For 192ir Hdr Sources.
Resumo:
High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future.
Resumo:
PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Fire management is a common practice in several reserves in the Cerrado, but its influences on bird reproduction remain unknown. In addition, the nesting biology of the Burrowing Owl (Athene cunicularia) has been studied in numerous environments, but not in tropical grasslands managed by fire. This study examined the effects of fire management on the nesting biology of A. cunicularia in Emas National Park, State of Goias, central Brazilian Cerrado. We compared the number of breeding pairs and their burrows in October and November 2009 at 15 study sites in grasslands managed by fire (firebreaks) and unmanaged grasslands adjacent to and distant from firebreaks. We visited active burrows two-four times and described the burrow entrances and sentinel sites and counted and observed adults and young. A total of 19 burrows were found at firebreaks. One and two burrows were found in grasslands adjacent to and distant from firebreaks, respectively. For all burrows found, one to three young reached the adult size, being able to fly and/or run in early November. The 22 burrows found were in the ground, associated or not with termite and ant nests. Most (86.4%) burrows had only one entrance. Only three burrows had two or three entrances. Structures used as sentinel perches by adults were mounds in front of the burrow entrances, termite nests, shrubs and trees. Most of these sentinel sites were shorter than 2 m high and located less than 10 m from the burrow entrance. At Emas National Park, firebreaks appear to provide more attractive conditions to the nesting of A. cunicularia than unmanaged grasslands, likely because of the short herbaceous stratum due to frequent burning of firebreaks. This study suggests that fire management provides suitable conditions for the successful reproduction of A. cunicularia in firebreaks at Emas National Park.
Resumo:
A simple and fast capillary zone electrophoresis (CZE) method has been developed and validated for quantification of a non-nucleoside reverse transcriptase inhibitor (NNRTI) nevirapine, in pharmaceuticals. The analysis was optimized using 10 mmol L-1 sodium phosphate buffer pH 2.5, +25 kV applied voltage, hydrodynamic injection 0.5 psi for 5 s and direct UV detection at 200 µm. Diazepam (50.0 µg mL-1) was used as internal standard. Under these conditions, nevirapine was analyzed in approximately less than 2.5 min. The analytical curve presented a coefficient of correlation of 0.9994. Limits of detection and quantification were 1.4 µg mL-1 and 4.3 µg mL-1, respectively. Intra- and inter-day precision expressed as relative standard deviations were 1.4% and 1.3%, respectively and the mean recovery was 100.81%. The active pharmaceutical ingredient was subjected to hydrolysis (acid, basic and neutral) and oxidative stress conditions. No interference of degradation products and tablet excipients were observed. This method showed to be rapid, simple, precise, accurate and economical for determination of nevirapine in pharmaceuticals and it is suitable for routine quality control analysis since CE offers benefits in terms of quicker method development and significantly reduced operating costs.
Resumo:
Solid-phase microextraction, using on-line bis(trimethylsilyl)trifluoroacetamide derivatisation, gas chromatography, and mass spectrometry, was evaluated in the quantification of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in water samples. Fibres encompassing a wide range of polarities were used with headspace and direct immersion sampling. For the immersion procedure, various parameters affecting MX extraction, including pH, salinity, temperature, and extraction time were evaluated. The optimised method (polyacrylate fibre; 20% Na2SO4; pH 2.0; 60 min; 20 °C) was applied for reservoir chlorinated water samples-either natural or spiked with MX (50 ng L-1 and 100 ng L-1). The recovery of MX ranged from 44 to 72%. Quantification of MX in water samples was done using external standard and the selected ion monitoring mode. Correlation coefficient (0.98%), relative standard deviation (5%), limit of detection (30 ng L-1) and limit of quantification (50 ng L-1) were obtained from calibration curve.
Resumo:
OBJETIVO: Em 2007, a Organização Mundial da Saúde (OMS) propôs um referencial de crescimento de cinco a 19 anos, a ser utilizado em continuidade ao referencial de menores de cinco anos (de 2006), que, entre outras características, aos cinco anos de idade mostra um bom ajuste com a curva de 2006. Este estudo visa comparar os referenciais da OMS com o crescimento observado em pré-escolares brasileiros. MÉTODOS: A partir dos dados antropométricos de 2.830 crianças com idade entre três e seis anos de duas amostras das cidades de Taubaté e Santo André, em São Paulo, foram calculados os valores dos percentis (P) 5, 50 e 95 de peso, estatura e índice de massa corpórea (IMC). Os valores dos novos referenciais da OMS foram comparados a esses resultados de acordo com o sexo e a faixa etária. RESULTADOS: Nos percentis de estatura, o referencial apresentou valores próximos ou pouco superiores aos dos pré-escolares até os cinco anos. Nessa idade, a tendência se inverte, obtendo-se valores progressivamente inferiores até os sete anos. Para peso e IMC, em todas as idades consideradas, o P5 e 50 dos referenciais são pouco menores que os das crianças, mas o P95 indica uma tendência de crescimento progressivamente menor, fazendo com que, próximo aos sete anos, o P95 de IMC dos pré-escolares da amostra seja cerca de 4kg/m² maior. CONCLUSÕES: Os referenciais da OMS apontam uma prevalência menor de magreza (desnutrição) e baixa estatura entre cinco e sete anos e, ao mesmo tempo, uma elevação importante da prevalência de obesidade entre três e sete anos de idade.
Resumo:
Um método espectrofotométrico simples foi desenvolvido para a determinação do bromidrato de fenoterol (BF) em comprimidos, gotas e xarope, como princípio ativo único e associado ao ibuprofeno. O método se baseia na reação de acoplamento oxidativo do BF com o 3-metil-2-benzotiazolinona hidrazona (MBTH), na presença de sulfato cérico, como agente oxidante. A mistura de BF, MBTH e sulfato cérico, em meio ácido, produz um composto colorido (vermelho castanho) com máximo de absorção a 475 nm. A curva de calibração foi linear num intervalo de concentração de 3,0 a 12,0 µg/mL, com coeficiente de correlação linear de 0,9998. Os parâmetros experimentais que afetam o desenvolvimento e a estabilidade do produto colorido foram cuidadosamente estudados e otimizados. O método foi aplicado em amostras comerciais e simuladas, obtendo-se coeficientes de variação entre 0,25 % a 0,82 % e médias de recuperação do padrão que variaram de 98 % a 102 %. O método proposto mostrou-se exato, preciso, linear e não é passível de interferência de excipientes, para as formas farmacêuticas comprimidos e gotas. Não houve interferência do ibuprofeno que consta de uma das formulações analisadas, associado ao BF. Quanto ao xarope, houve interferência do veículo sugerindo reações de seus componentes com o MBTH.
Resumo:
OBJETIVOS: Avaliar a acurácia de três pontos de corte na determinação da pressão arterial elevada em adolescentes, dada a forte relação entre o excesso de peso e valores elevados de pressão arterial. MÉTODOS: Participaram do estudo 1.021 adolescentes de ambos os sexos, selecionados de maneira aleatória nas escolas públicas e particulares de Londrina (PR). O peso corporal foi aferido por meio de balança digital, e a estatura, por um estadiômetro portátil com extensão máxima de 2 metros. A pressão arterial foi avaliada através de um aparelho automático. A capacidade do índice de massa corporal de detectar a pressão arterial elevada foi averiguada por meio da curva ROC e seus parâmetros (sensibilidade, especificidade e área sob a curva). RESULTADOS: Os pontos de corte da proposta nacional apresentaram maior acurácia (masculino: 0,636±0,038; feminino: 0,585±0,043) quando comparados aos pontos de corte das propostas internacional (masculino: 0,594±0,040; feminino: 0,570±0,044) e norte-americana (masculino: 0,612±0,039; feminino: 0,578±0,044). CONCLUSÃO: A proposta nacional foi a que apresentou melhor acurácia na indicação de valores elevados de pressão arterial.
Resumo:
We evaluated the performance of a novel procedure for segmenting mammograms and detecting clustered microcalcifications in two types of image sets obtained from digitization of mammograms using either a laser scanner, or a conventional ""optical"" scanner. Specific regions forming the digital mammograms were identified and selected, in which clustered microcalcifications appeared or not. A remarkable increase in image intensity was noticed in the images from the optical scanner compared with the original mammograms. A procedure based on a polynomial correction was developed to compensate the changes in the characteristic curves from the scanners, relative to the curves from the films. The processing scheme was applied to both sets, before and after the polynomial correction. The results indicated clearly the influence of the mammogram digitization on the performance of processing schemes intended to detect microcalcifications. The image processing techniques applied to mammograms digitized by both scanners, without the polynomial intensity correction, resulted in a better sensibility in detecting microcalcifications in the images from the laser scanner. However, when the polynomial correction was applied to the images from the optical scanner, no differences in performance were observed for both types of images. (C) 2008 SPIE and IS&T [DOI: 10.1117/1.3013544]