985 resultados para Similar tests
Resumo:
Examination of the geotechnical characteristics of Weddell Sea, Maud Rise, and South Orkney microcontinental margin sediments recovered during ODP Leg 113 reveals that the reduction in porosity (consolidation) of the siliciclastic, calcareous, and diatomaceous sediments is primarily a process governed by vertical stresses created by overburden. The initial porosity of the sediments in these areas is governed by the amount of diatoms present. The more diatoms, the higher the porosity. Surficial diatom-rich sediments are everywhere overconsolidated. This is attributed to the strong microfabric created by the diatoms, calcareous and clay particles. The deeper diatom-free sediments of Maud Rise range from slightly underconsolidated to normally consolidated. The silty clays and clays of the Weddell Sea and South Orkney margin are underconsolidated. The degree of underconsolidation of these sediments is similar to that determined in a number of different locations throughout the world's oceans. The very low permeability of the Weddell Sea and South Orkney margin sediments appears to account for this underconsolidation.
Resumo:
Dry-wall laser inertial fusion (LIF) chambers will have to withstand strong bursts of fast charged particles which will deposit tens of kJ m−2 and implant more than 1018 particles m−2 in a few microseconds at a repetition rate of some Hz. Large chamber dimensions and resistant plasma-facing materials must be combined to guarantee the chamber performance as long as possible under the expected threats: heating, fatigue, cracking, formation of defects, retention of light species, swelling and erosion. Current and novel radiation resistant materials for the first wall need to be validated under realistic conditions. However, at present there is a lack of facilities which can reproduce such ion environments. This contribution proposes the use of ultra-intense lasers and high-intense pulsed ion beams (HIPIB) to recreate the plasma conditions in LIF reactors. By target normal sheath acceleration, ultra-intense lasers can generate very short and energetic ion pulses with a spectral distribution similar to that of the inertial fusion ion bursts, suitable to validate fusion materials and to investigate the barely known propagation of those bursts through background plasmas/gases present in the reactor chamber. HIPIB technologies, initially developed for inertial fusion driver systems, provide huge intensity pulses which meet the irradiation conditions expected in the first wall of LIF chambers and thus can be used for the validation of materials too.
Resumo:
Dry-wall laser inertial fusion (LIF) chambers will have to withstand strong bursts of fast charged particles which will deposit tens of kJ m−2 and implant more than 1018 particles m−2 in a few microseconds at a repetition rate of some Hz. Large chamber dimensions and resistant plasma-facing materials must be combined to guarantee the chamber performance as long as possible under the expected threats: heating, fatigue, cracking, formation of defects, retention of light species, swelling and erosion. Current and novel radiation resistant materials for the first wall need to be validated under realistic conditions. However, at present there is a lack of facilities which can reproduce such ion environments. This contribution proposes the use of ultra-intense lasers and high-intense pulsed ion beams (HIPIB) to recreate the plasma conditions in LIF reactors. By target normal sheath acceleration, ultra-intense lasers can generate very short and energetic ion pulses with a spectral distribution similar to that of the inertial fusion ion bursts, suitable to validate fusion materials and to investigate the barely known propagation of those bursts through background plasmas/gases present in the reactor chamber. HIPIB technologies, initially developed for inertial fusion driver systems, provide huge intensity pulses which meet the irradiation conditions expected in the first wall of LIF chambers and thus can be used for the validation of materials too.
Resumo:
This article investigates experimentally the application of health monitoring techniques to assess the damage on a particular kind of hysteretic (metallic) damper called web plastifying dampers, which are subjected to cyclic loading. In general terms, hysteretic dampers are increasingly used as passive control systems in advanced earthquake-resistant structures. Nonparametric statistical processing of the signals obtained from simple vibration tests of the web plastifying damper is used here to propose an area index damage. This area index damage is compared with an alternative energy-based index of damage proposed in past research that is based on the decomposition of the load?displacement curve experienced by the damper. Index of damage has been proven to accurately predict the level of damage and the proximity to failure of web plastifying damper, but obtaining the load?displacement curve for its direct calculation requires the use of costly instrumentation. For this reason, the aim of this study is to estimate index of damage indirectly from simple vibration tests, calling for much simpler and cheaper instrumentation, through an auxiliary index called area index damage. Web plastifying damper is a particular type of hysteretic damper that uses the out-of-plane plastic deformation of the web of I-section steel segments as a source of energy dissipation. Four I-section steel segments with similar geometry were subjected to the same pattern of cyclic loading, and the damage was evaluated with the index of damage and area index damage indexes at several stages of the loading process. A good correlation was found between area index damage and index of damage. Based on this correlation, simple formulae are proposed to estimate index of damage from the area index damage.
Resumo:
A revision of a similar publication, AMS-16.
Resumo:
In the past, the accuracy of facial approximations has been assessed by resemblance ratings (i.e., the comparison of a facial approximation directly to a target individual) and recognition tests (e.g., the comparison of a facial approximation to a photo array of faces including foils and a target individual). Recently, several research studies have indicated that recognition tests hold major strengths in contrast to resemblance ratings. However, resemblance ratings remain popularly employed and/or are given weighting when judging facial approximations, thus indicating that no consensus has been reached. This study aims to further investigate the matter by comparing the results of resemblance ratings and recognition tests for two facial approximations which clearly differed in their morphological appearance. One facial approximation was constructed by an experienced practitioner privy to the appearance of the target individual (practitioner had direct access to an antemortem frontal photograph during face construction), while the other facial approximation was constructed by a novice under blind conditions. Both facial approximations, whilst clearly morphologically different, were given similar resemblance scores even though recognition test results produced vastly different results. One facial approximation was correctly recognized almost without exception while the other was not correctly recognized above chance rates. These results suggest that resemblance ratings are insensitive measures of the accuracy of facial approximations and lend further weight to the use of recognition tests in facial approximation assessment. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
Resumo:
This Article Right arrow Full Text Right arrow Full Text (PDF) Right arrow Supplemental material Right arrow Alert me when this article is cited Right arrow Alert me if a correction is posted Services Right arrow Similar articles in this journal Right arrow Similar articles in PubMed Right arrow Alert me to new issues of the journal Right arrow Download to citation manager Right arrow Reprints and Permissions Right arrow Copyright Information Right arrow Books from ASM Press Right arrow MicrobeWorld Citing Articles Right arrow Citing Articles via HighWire Right arrow Citing Articles via Google Scholar Google Scholar Right arrow Articles by Lee, N. Right arrow Articles by McCarthy, J. Right arrow Search for Related Content PubMed Right arrow PubMed Citation Right arrow Articles by Lee, N. Right arrow Articles by McCarthy, J. Right arrow Pubmed/NCBI databases * Substance via MeSH Previous Article | Next Article Journal of Clinical Microbiology, August 2006, p. 2773-2778, Vol. 44, No. 8 0095-1137/06/$08.00+0 doi:10.1128/JCM.02557-05 Copyright © 2006, American Society for Microbiology. All Rights Reserved. Effect of Sequence Variation in Plasmodium falciparum Histidine- Rich Protein 2 on Binding of Specific Monoclonal Antibodies: Implications for Rapid Diagnostic Tests for Malaria{dagger} Nelson Lee,1,2 Joanne Baker,2 Kathy T. Andrews,1 Michelle L. Gatton,1,3 David Bell,4 Qin Cheng,2,3 and James McCarthy1* Australian Centre for International and Tropical Health and Nutrition, Queensland Institute of Medical Research and School of Population Health, University of Queensland, Queensland, Australia,1 Department of Drug Resistance and Diagnostics, Australian Army Malaria Institute, Brisbane, Australia,2 Malaria Drug Resistance and Chemotherapy, Queensland Institute of Medical Research, Queensland, Australia,3 World Health Organization, Regional Office for the Western Pacific, Manila, Philippines4 Received 8 December 2005/ Returned for modification 23 February 2006/ Accepted 26 May 2006 The ability to accurately diagnose malaria infections, particularly in settings where laboratory facilities are not well developed, is of key importance in the control of this disease. Rapid diagnostic tests (RDTs) offer great potential to address this need. Reports of significant variation in the field performance of RDTs based on the detection of Plasmodium falciparum histidine-rich protein 2 (HRP2) (PfHRP2) and of significant sequence polymorphism in PfHRP2 led us to evaluate the binding of four HRP2-specific monoclonal antibodies (MABs) to parasite proteins from geographically distinct P. falciparum isolates, define the epitopes recognized by these MABs, and relate the copy number of the epitopes to MAB reactivity. We observed a significant difference in the reactivity of the same MAB to different isolates and between different MABs tested with single isolates. When the target epitopes of three of the MABs were determined and mapped onto the peptide sequences of the field isolates, significant variability in the frequency of these epitopes was observed. These findings support the role of sequence variation as an explanation for variations in the performance of HRP2-based RDTs and point toward possible approaches to improve their diagnostic sensitivities
Resumo:
Background: Coronary heart disease patients have to learn to manage their condition to maximise quality of life and prevent recurrence or deterioration. They may develop their own informal methods of self-management in addition to the advice they receive as part of formal cardiac rehabilitation programmes. This study aimed to explore the use of complementary and alternative medicines and therapies (CAM), self-test kits and attitudes towards health of UK patients one year after referral to cardiac rehabilitation. Method: Questionnaire given to 463 patients attending an assessment clinic for 12 month follow up in four West Midlands hospitals. Results: 91.1% completed a questionnaire. 29.1% of patients used CAM and/or self-test kits for self-management but few (8.9%) used both methods. CAM was more often used for treating other illnesses than for CHD management. Self-test kit use (77.2%,) was more common than CAM (31.7%,) with BP monitors being the most prevalent (80.0%). Patients obtained self-test kits from a wide range of sources, for the most part (89.5%) purchased entirely on their own initiative. Predictors of self-management were post revascularisation status and higher scores on 'holism', 'rejection of authority' and 'individual responsibility'. Predictors of self-test kit use were higher `holism' and 'individual responsibility' scores. Conclusion: Patients are independently using new technologies to monitor their cardiovascular health, a role formerly carried out only by healthcare practitioners. Post-rehabilitation patients reported using CAM for self-management less frequently than they reported using self-test kits. Reports of CAM use were less frequent than in previous surveys of similar patient groups. Automatic assumptions cannot be made by clinicians about which CHD patients are most likely to self-manage. In order to increase trust and compliance it is important for doctors to encourage all CHD patients to disclose their self-management practices and to continue to address this in follow up consultations.
Resumo:
The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.
Resumo:
An international round robin study of the viscosity measurements and aging of fast pyrolysis bio-oil has been undertaken recently, and this work is an outgrowth from that effort. Two bio-oil samples were distributed to two laboratories for accelerated aging tests and to three laboratories of long-term aging studies. The accelerated aging test was defined as the change in viscosity of a sealed sample of bio-oil held for 24 h at 80 °C. The test was repeated 10 times over consecutive days to determine the intra-laboratory repeatability of the method. Other bio-oil samples were placed in storage at three temperatures, 21, 5, and -17 °C, for a period of up to 1 year to evaluate the change in viscosity. The variation in the results of the accelerated aging test was shown to be low within a given laboratory. The long-term aging studies showed that storage of a filtered bio-oil under refrigeration can minimize the amount of change in viscosity. The accelerated aging test gave a measure of change similar to that of 6-12 months of storage at room temperature for a filtered bio-oil. Filtration of solids was identified as a key contributor to improving the stability of the bio-oil as expressed by the viscosity based on results of the accelerated aging tests as well as long-term aging studies. Only the filtered bio-oil consistently gave useful results in the accelerated aging and long-term aging studies. The inconsistency suggests that better protocols need to be developed for sampling bio-oils. These results can be helpful in setting standards for use of bio-oil, which is just coming into the marketplace. © 2012 American Chemical Society.
Resumo:
Today's market conditions require nonprofit leaders to act in an increasingly business-like fashion. This study asks whether NPO leaders have a similar disposition to act entrepreneurially as for-profit entrepreneurs, but hold different underlying motives. For this purpose, the study contrasts a sample of 72 leaders of nonprofit organizations with 117 entrepreneurs on their personality traits and explicit motives using standard personality tests and interviews. Both groups exhibit similar general and entrepreneurship-specific personality traits but differ significantly regarding their motivation. While nonprofit leaders' motivation stems primarily from the meaningfulness of their work; entrepreneurs are mainly motivated by the independence as well as by the income and profit provided by their work. This paper helps us understand who leaders of nonprofit organizations are.
Resumo:
Clogging is the main operational problem associated with horizontal subsurface flow constructed wetlands (HSSF CWs). The measurement of saturated hydraulic conductivity has proven to be a suitable technique to assess clogging within HSSF CWs. The vertical and horizontal distribution of hydraulic conductivity was assessed in two full-scale HSSF CWs by using two different in situ permeameter methods (falling head (FH) and constant head (CH) methods). Horizontal hydraulic conductivity profiles showed that both methods are correlated by a power function (FH= CH 0.7821, r 2=0.76) within the recorded range of hydraulic conductivities (0-70 m/day). However, the FH method provided lower values of hydraulic conductivity than the CH method (one to three times lower). Despite discrepancies between the magnitudes of reported readings, the relative distribution of clogging obtained via both methods was similar. Therefore, both methods are useful when exploring the general distribution of clogging and, specially, the assessment of clogged areas originated from preferential flow paths within full-scale HSSF CWs. Discrepancy between methods (either in magnitude and pattern) aroused from the vertical hydraulic conductivity profiles under highly clogged conditions. It is believed this can be attributed to procedural differences between the methods, such as the method of permeameter insertion (twisting versus hammering). Results from both methods suggest that clogging develops along the shortest distance between water input and output. Results also evidence that the design and maintenance of inlet distributors and outlet collectors appear to have a great influence on the pattern of clogging, and hence the asset lifetime of HSSF CWs. © Springer Science+Business Media B.V. 2011.
Resumo:
The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.
Resumo:
One key step of the industrial development of a tidal energy device is the testing of scale prototype devices within a controlled laboratory environment. At present, there is no available experimental protocol which addresses in a quantitative manner the differences which can be expected between results obtained from the different types of facilities currently employed for this type of testing. As a consequence, where differences between results are found it has been difficult to confirm the extent to which these differences relate to the device performance or to the test facility type. In the present study, a comparative ”Round Robin” testing programme has been conducted as part of the EC FP VII MaRINET program in order to evaluate the impact of different experimental facilities on the test results. The aim of the trials was to test the same model tidal turbine in four different test facilities to explore the sensitivity of the results to the choice of facility. The facilities comprised two towing tanks, of very different size, and two circulating water channels. Performance assessments in terms of torque, drag and inflow speed showed very similar results in all facilities. However, expected differences between the different tank types (circulating and towing) were observed in the fluctuations of torque and drag measurements. The main facility parameters which can influence the behaviour of the turbine were identified; in particular the effect of blockage was shown to be significant in cases yielding for high thrust coefficients, even at relatively small blockage ratios.
Resumo:
A prospective randomised controlled clinical trial of treatment decisions informed by invasive functional testing of coronary artery disease severity compared with standard angiography-guided management was implemented in 350 patients with a recent non-ST elevation myocardial infarction (NSTEMI) admitted to 6 hospitals in the National Health Service. The main aims of this study were to examine the utility of both invasive fractional flow reserve (FFR) and non-invasive cardiac magnetic resonance imaging (MRI) amongst patients with a recent diagnosis of NSTEMI. In summary, the findings of this thesis are: (1) the use of FFR combined with intravenous adenosine was feasible and safe amongst patients with NSTEMI and has clinical utility; (2) there was discordance between the visual, angiographic estimation of lesion significance and FFR; (3). The use of FFR led to changes in treatment strategy and an increase in prescription of medical therapy in the short term compared with an angiographically guided strategy; (4) in the incidence of major adverse cardiac events (MACE) at 12 months follow up was similar in the two groups. Cardiac MRI was used in a subset of patients enrolled in two hospitals in the West of Scotland. T1 and T2 mapping methods were used to delineate territories of acute myocardial injury. T1 and T2 mapping were superior when compared with conventional T2-weighted dark blood imaging for estimation of the ischaemic area-at-risk (AAR) with less artifact in NSTEMI. There was poor correlation between the angiographic AAR and MRI methods of AAR estimation in patients with NSTEMI. FFR had a high accuracy at predicting inducible perfusion defects demonstrated on stress perfusion MRI. This thesis describes the largest randomized trial published to date specifically looking at the clinical utility of FFR in the NSTEMI population. We have provided evidence of the diagnostic and clinical utility of FFR in this group of patients and provide evidence to inform larger studies. This thesis also describes the largest ever MRI cohort, including with myocardial stress perfusion assessments, specifically looking at the NSTEMI population. We have demonstrated the diagnostic accuracy of FFR to predict reversible ischaemia as referenced to a non-invasive gold standard with MRI. This thesis has also shown the futility of using dark blood oedema imaging amongst all comer NSTEMI patients when compared to novel T1 and T2 mapping methods.