945 resultados para SE(T) SPECIMEN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe an additional saurischian specimen from the Caturrita Formation (Norian) of the Parana Basin, southern Brazil. This material was collected in the 1950s and remained unstudied due to its fragmentary condition. Detailed comparisons with other saurischians worldwide reveal that some characters of the ilium, including the low ventral projection of the medial wall of the acetabulum and its concave ventral margin, together with the short triangular shape of the pre-acetabular process and its mound-like dorsocaudal edge, resemble those of sauropodomorphs such as Plateosaurus and Riojasaurus. This set of traits suggests that MN 1326-V has affinities with basal Sauropodomorpha, probably closer to plateosaurians than to Saturnalia-like taxa. Previous records of this clade in the Caturrita Formation include Unaysaurus, which has been related to Plateosaurus within Plateosauridae. Alternative schemes suggest that plateosaurids include Plateosaurus plus the Argentinean 'prosauropods' Coloradisaurus and Riojasaurus. Both hypotheses raise biogeographic questions, as a close relationship between faunas from South America and Europe excluding Africa and North America is not supported by geological and biostratigraphical evidence. Additionally, the absence of plateosaurids in other continents suggests that the geographical distribution of this taxon is inconsistent with the geological history of western Pangaea, and this demands further investigations of the phylogeny of sauropodomorphs or improved sampling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deformation of a ring under axial compression is analyzed in order to estimate a favorable ring specimen geometry capable of limiting the influence of friction on the stress-strain curve obtained from SHPB tests. The analysis shows that the use of a ring specimen with a large inner diameter and a small radial thickness offers some advantages comparing with the traditional disk sample. In particular, it can improve the reliability of the test results for ductile materials in the presence of friction. Based on the deformation analysis of a ductile ring under compression, a correction coefficient is proposed to relate the actual material stress strain curve with the reading from the SHPB. It is shown using finite element simulation that the proposed correction can be used for a wide range of conventional ductile materials. Experimental results with steel alloys indicate that the correction procedure is an effective technique for an accurate measurement of the dynamic material strength response. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an investigation of the ductile tearing properties for a girth weld made of an API 5L X80 pipeline steel using experimentally measured crack growth resistance curves. Use of these materials is motivated by the increasing demand in the number of applications for manufacturing high strength pipes for the oil and gas industry including marine applications and steel catenary risers. Testing of the pipeline girth welds employed side-grooved, clamped SE(T) specimens and shallow crack bend SE(B) specimens with a weld centerline notch to determine the crack growth resistance curves based upon the unloading compliance (UC) method using the single specimen technique. Recently developed compliance functions and η-factors applicable for SE(T) and SE(B) fracture specimens with homogeneous material and overmatched welds are introduced to determine crack growth resistance data from laboratory measurements of load-displacement records.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the problem of performing a numerical simulation of quasi-static crack propagation within an adhesive layer of a bonded joint under Mode I loading affected by stress field changes due to thermal-chemical shrinkage induced by cure process is addressed. Secondly, a parametric study on fracture critical energy, cohesive strength and Young's modulus is performed. Finally, a particular case of adhesive layer stiffening is simulated in order to verify qualitatively the major effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a conventional x-ray tube source. Feasibility and potential applications of preclinical and clinical phase-contrast CT are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of the proliferation fraction is becoming more and more important; however, there is no consensus concerning optimal validation. Depending on the institute the proliferation fraction is determined either from a core biopsy (SB) or resection specimen (OP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The low diagnostic yield of vitrectomy specimen analysis in chronic idiopathic uveitis (CIU) has been related to the complex nature of the underlying disease and to methodologic and tissue immanent factors in older studies. In an attempt to evaluate the impact of recently acquired analytic methods, the authors assessed the current diagnostic yield in CIU. METHODS: Retrospective analysis of consecutive vitrectomy specimens from patients with chronic endogenous uveitis (n = 56) in whom extensive systemic workup had not revealed a specific diagnosis (idiopathic) and medical treatment had not resulted in a satisfying clinical situation. Patients with acute postoperative endophthalmitis served a basis for methodologic comparison (Group 2; n = 21). RESULTS: In CIU, a specific diagnosis provided in 17.9% and a specific diagnosis excluded in 21.4%. In 60.7% the laboratory investigations were inconclusive. In postoperative endophthalmitis, microbiological culture established the infectious agent in 47.6%. In six of eight randomly selected cases, eubacterial PCR identified bacterial DNA confirming the culture results in three, remaining negative in two with a positive culture and being positive in three no growth specimens. A double negative result never occurred, suggesting a very high detection rate, when both tests were applied. CONCLUSIONS: The diagnostic yield of vitrectomy specimen analysis has not been improved by currently routinely applied methods in recent years in contrast to the significantly improved sensitivity of combined standardized culture and PCR analysis in endophthalmitis. Consequently, the low diagnostic yield in CIU has to be attributed to insufficient understanding of the underlying pathophysiologic mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening for chlamydia in women is widely recommended. We evaluated the performance of two nucleic acid amplification tests for detecting Chlamydia trachomatis in self-collected vulvovaginal-swab and first-catch urine specimens from women in a community setting and a strategy for optimizing the sensitivity of an amplified enzyme immunoassay on vulvovaginal-swab specimens. We tested 2,745 paired vulvovaginal-swab and urine specimens by PCR (Roche Cobas) or strand displacement amplification (SDA; Becton Dickinson). There were 146 women infected with chlamydia. The assays detected 97.3% (95% confidence interval [CI], 93.1 to 99.2%) of infected patients with vulvovaginal-swab specimens and 91.8% (86.1 to 95.7%) with urine specimens. We tested 2,749 vulvovaginal-swab specimens with both a nucleic acid amplification test and a polymer conjugate-enhanced enzyme immunoassay with negative-gray-zone testing. The relative sensitivities obtained after retesting specimens in the negative gray zone were 74.3% (95% CI, 62.8 to 83.8%) with PCR and 58.3% (95% CI, 46.1 to 69.8%) with SDA. In community settings, both vulvovaginal-swab and first-catch urine specimens from women are suitable substrates for nucleic acid amplification tests, but enzyme immunoassays, even after negative-gray-zone testing, should not be used in screening programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Empirical antibiotic therapy is based on patients' characteristics and antimicrobial susceptibility data. Hospital-wide cumulative antibiograms may not sufficiently support informed decision-making for optimal treatment of hospitalized patients. METHODS: We studied different approaches to analysing antimicrobial susceptibility rates (SRs) of all diagnostic bacterial isolates collected from patients hospitalized between July 2005 and June 2007 at the University Hospital in Zurich, Switzerland. We compared stratification for unit-specific, specimen type-specific (blood, urinary, respiratory versus all specimens) and isolate sequence-specific (first, follow-up versus all isolates) data with hospital-wide cumulative antibiograms, and studied changes of mean SR during the course of hospitalization. RESULTS: A total of 16 281 isolates (7965 first, 1201 follow-up and 7115 repeat isolates) were tested. We found relevant differences in SRs across different hospital departments. Mean SRs of Escherichia coli to ciprofloxacin ranged between 64.5% and 95.1% in various departments, and mean SRs of Pseudomonas aeruginosa to imipenem and meropenem ranged from 54.2% to 100% and 80.4% to 100%, respectively. Compared with hospital cumulative antibiograms, lower SRs were observed in intensive care unit specimens, follow-up isolates and isolates causing nosocomial infections (except for Staphylococcus aureus). Decreasing SRs were observed in first isolates of coagulase-negative staphylococci with increasing interval between hospital admission and specimen collection. Isolates from different anatomical sites showed variations in SRs. CONCLUSIONS: We recommend the reporting of unit-specific rather than hospital-wide cumulative antibiograms. Decreasing antimicrobial susceptibility during hospitalization and variations in SRs in isolates from different anatomical sites should be taken into account when selecting empirical antibiotic treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Tooth root problems and periodontal diseases are common in South American camelids (SAC). The objective was to evaluate and optimize the imaging technique for dental radiography in SAC and to describe the radiographic and computed tomographic (CT) anatomy of normal teeth at different ages. In this study, the heads of 20 healthy SAC slaughtered for meat production or euthanized for reasons not related to dental problems included 7 female and 10 male llamas and 3 male alpacas. Using a standardized protocol, radiographs and CT scans of the 20 specimen were performed. RESULTS The most useful radiographic projections for mandibular and maxillary cheek teeth evaluation turned out to be lateral30°ventral-laterodorsal and lateral30°dorsal-lateroventral with slight separation of the dental arcades respectively. Digital radiographic and CT appearance of the mandibular and maxillary teeth were described from the beginning of mineralization till maturity. In addition the normal range of the CT radio density of different cheek teeth and different dental tissues were measured. Hounsfield units of different dental tissues of SAC turned out to be similar to equids. Deviation, shortening and partial destruction of the distal tooth root of mandibular 09's and 10's and of maxillary 09's was observed and the existence of a common pulp chamber in younger teeth was revealed. CONCLUSIONS The present study provides information about the dental imaging morphology in clinically healthy SAC. This basic information provides fundamental knowledge for evaluating images and planning treatments in clinically affected animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesoscopic 3D imaging has become a widely used optical imaging technique to visualize intact biological specimens. Selective plane illumination microscopy (SPIM) visualizes samples up to a centimeter in size with micrometer resolution by 3D data stitching but is limited to fluorescent contrast. Optical projection tomography (OPT) works with fluorescent and nonfluorescent contrasts, but its resolution is limited in large samples. We present a hybrid setup (OPTiSPIM) combining the advantages of each technique. The combination of fluorescent and nonfluorescent high-resolution 3D data into integrated datasets enables a more extensive representation of mesoscopic biological samples. The modular concept of the OPTiSPIM facilitates incorporation of the transmission OPT modality into already established light sheet based imaging setups.