979 resultados para Repeated Load Triaxial (RLT) test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated estradiol benzoate effects on oocytes/embryos recovery rate and the influence of this drug on the hematopoietic system. Twenty four bitches were divided in two groups, Group I, 12 females that received a single shot of estradiol benzoate, 0.2 mg/kg intramuscularly, between 2 and 7 days after the date of the last mismating or insemination and, Group II (control), 12 bitches that received 0.2 ml/kg of oily diluent, in corresponding dates. The bitches were ovary-hysterectomized and the uterus/oviduct were isolated and flushed with a PBS, heparin and polyvinyl alcohol solution. Oocytes and embryos were quantified and classified according to their stage of development. Blood counts were performed on M1 (before drug administration), M2 (15 days after drug administration) and M3 (40 days after drug administration). Pearson correlation coefficient was used to analyze the variable retrieval structures, while Fisher exact test was used for the analysis of embryonic viability. ANOVA was used to analyze repeated measurements and Tukey test for hematological parameters. All tests were performed at 5% significance level. The recovery rate of total structures in group I was lower (22.88%) than group II (65.85%). A lower embryo recovery (ratio 3: 52) rate and a greater number of degenerated structures (ratio 11: 1) were observed in group I. Hematological parameters showed significant difference in erythrocytes, hematocrit and hemoglobin concentrations 15 days after drug administration and difference in leukocytes concentration 40 days after using the medication in bitches of group I, however, at the end of the experiment all bitches had blood counts considered normal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study provides further developments of the evaluation procedure for J and CTOD in SE(T) fracture specimens based on plastic eta-factors and load separation analysis. Non-linear finite element analyses for plane-strain and 3-D models provide the relationship between plastic work and crack driving forces which define the eta-values. Further analyses based on the load separation method define alternative eta-values for the analyzed specimen configurations. Overall, the present results provide improved estimation equations for J and CTOD as a function of loading condition (pin load vs. clamp ends), crack geometry and strain hardening properties. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

É muito importante para a indústria fornecer produtos competitivos e que exerçam corretamente as suas funções perante o cliente. Uma das ferramentas existentes para atingir estes objetivos é a realização de testes de fadiga e durabilidade cada vez mais refinados e em espaço mais curto de tempo. Uma das maneiras de se executar testes de fadiga mais precisos é utilizando parâmetros que sejam fiéis à solicitação que o produto sofre durante o seu uso. Com esse intuito surgiram os testes de fadiga sob amplitude variável. Juntamente com eles surgem as particularidades deste tipo de solicitação, que é de natureza complexa. Algumas particularidades são a dependência do resultado na história de carregamento (também chamada de \"interação de cargas\") e a variação abrupta do nível de carga durante o tempo de aplicação. Fenômenos estes chamados de sobrecarga ou subcarga (overload e underload), que aqui serão agrupados, muitas vezes de forma simplista, de perturbações no espectro de fadiga. A finalidade principal deste trabalho é descrever a influência das perturbações ocorridas nas solicitações nos testes de fadiga em regime de amplitude variável, mais precisamente em testes de bancada, em que se busca a reprodução de situações de trabalho reais de um componente. Apesar de esse assunto ser alvo de diversas investigações recentes, nenhum trabalho tem como foco a influência das paradas (completa remoção de carga) realizadas durante um teste de fadiga acelerado. Essas paradas são extremamente comuns na prática laboratorial, seja por manutenção do equipamento, inspeção da amostra ou necessidade de operação. O objeto alvo de estudo nesta pesquisa é um suporte metálico de buzina, utilizado em automóveis de passeio. Apesar de sua concepção simples, tal componente é responsável por exercer funções importantes e é sujeito a uma interessante gama de solicitações. Como resultado observou-se que a aplicação das paradas durante os testes de fadiga simulados no componente automotivo, provoca variações em sua vida útil total. E o tempo de parada também exerce influência nesta variação observada. Essas paradas não se encaixam perfeitamente nas classificações de perturbações no espectro registradas na literatura. Por esse motivo o trabalho se propõe ainda a sintetizar e uniformizar a terminologia para as variações abruptas de tensão aplicadas no tempo (as sobrecargas e as subcargas), tendo em vista que ocorre a falta de consenso entre os termos utilizados atualmente na literatura e seus respectivos conceitos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As reported by Shipboard Scientific Party (2001b, doi:10.2973/odp.proc.ir.191.104.2001) in the Site 1179 chapter of the Initial Reports volume, Leg 191 Site 1179 is located on abyssal seafloor northwest of Shatsky Rise, ~1650 km east of Japan. This part of the Pacific plate was formed during the Early Cretaceous, as shown by northeast-trending M-series magnetic lineations that become younger toward the northwest (Larson and Chase, 1972, doi:10.1130/0016-7606(1972)83[3627:LMEOTW]2.0.CO;2; Sager et al., 1988, doi:10.1029/JB093iB10p11753; Nakanishi et al., 1989, doi:10.1029/1999JB900002). The site is situated on magnetic Anomaly M8 (Nakanishi et al., 1999, doi:10.1029/1999JB900002), corresponding to an age of ~129 Ma and the Hauterivian stage of the Early Cretaceous (Gradstein et al., 1994, doi:10.1029/94JB01889; 1995). The sediments recovered at Site 1179 are split into four lithostratigraphic units based on composition and color (Shipboard Scientific Party, 2001b, doi:10.2973/odp.proc.ir.191.104.2001). Unit I (0-221.52 meters below seafloor [mbsf]) is a dominantly olive-gray clay- and radiolarian-bearing diatom ooze. Unit II (221.52-246.0 mbsf) is a yellowish brown to light brown clay-rich and diatom-bearing radiolarian ooze. Unit III (246.0-283.53 mbsf) is composed of brown pelagic clay. Unit IV (283.53-377.15 mbsf) is composed of chert and some porcellanite; any softer sediments present were washed out of the core barrel by the fluid circulating during the coring process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The calcineurin pathway has been involved in the development of cardiac hypertrophy, yet it remains unknown whether calcineurin activity can be regulated in myocardium independently from hypertrophy and cardiac load. Methods: To test that hypothesis, we measured calcineurin activity in a rat model of infrarenal aortic constriction (IR), which affects neurohormonal pathways without increasing cardiac afterload. Results: In this model, there was no change in arterial pressure over the 4-week experimental period, and the left ventricle/body weight ratio did not increase. At 2 weeks after IR, calcineurin activity was increased 1.8-fold (P

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was undertaken to assess the impact of dietary carbohydrate source on food intake, body composition, glucose tolerance, insulin sensitivity, and glucose and insulin concentrations in overweight and obese cats with reduced insulin sensitivity. Sixteen overweight and obese cats were divided into two groups and randomly allocated one of two extruded diets formulated to contain similar starch content (33%) from different cereal sources (sorghum and corn versus rice). Meal response, glucose tolerance and insulin sensitivity tests were performed before and after a 6-week weight-maintenance phase and after an additional 8-week free-access feeding phase. Dual energy x-ray absorptiometry (DEXA)-derived body composition was determined in each cat before the study and after each test phase. Food intake was measured daily and body weight measured twice weekly for the duration of the study. When compared with the sorghum/corn-based diet, cats fed the rice-based diet consumed more energy and gained more weight in response to free-access feeding. Cats fed the rice-based diet also tended to have higher glucose concentrations and insulin secretion in response to a glucose load or a test meal. We conclude that a sorghum and corn blend is a superior carbohydrate source than rice for overweight cats with glucose intolerance and reduced insulin sensitivity. Such a diet may help to minimize overeating and additional weight gain, and may also reduce the risk of developing type 2 diabetes mellitus. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The wear rates of sliding surfaces are significantly reduced if mild oxidational wear can be encouraged. It is hence of prime importance in the interest of component life and material conservation to understand the factors necessary to promote mild, oxidational wear, The present work investigates the fundamental mechanism of the running-in wear of BS EN 31!EN 8 steel couples. under various conditions of load. speed and test duration. Unidirectional sliding experiments were carried out on a pin-on~disc wear machine where frictional force, wear rate, temperature and contact resistance were continuously monitored during each test. Physical methods of analysis (x-ray, scanning electron microscopy etc.) were used to examine the wear debris and worn samples. The wear rate versus load curves revealed mild wear transitions, which under long duration of running, categorized mild wear into four distinct regions.α-Fe20s. Fe304, FeO and an oxide mixture were the predominant oxides in four regions of oxidational wear which were identified above the Welsh T2 transition. The wear curves were strongly effected by the speed and test duration. A surface model was used to calculate the surface parameters, and the results were found to be comparable with the experimentally observed parameters. Oxidation was responsible for the transition from severe to mild wear at a load corresponding to the Welsh T2 transition. In the running-in period sufficient energy input and surface hardness enabled oxide growth rate to increase and eventually exceeded the rate of removal, where mild wear ensued. A model was developed to predict the wear volume up to the transition. Remarkable agreement was found between the theoretical prediction and the experimentally-measured values. The oxidational mechanjsm responsible for transitjon to mild wear under equilibrium conditions was related to the formation of thick homogenous oxide plateaux on subsurface hardened layers, FeO was the oxide formed initially at the onset of mild wear but oxide type changed.during the total running period to give an equilibrium oxide whose nature depended on the loads applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cold in-place recycling (CIR) and cold central plant recycling (CCPR) of asphalt concrete (AC) and/or full-depth reclamation (FDR) of AC and aggregate base are faster and less costly rehabilitation alternatives to conventional reconstruction for structurally distressed pavements. This study examines 26 different rehabilitation projects across the USA and Canada. Field cores from these projects were tested for dynamic modulus and repeated load permanent deformation. These structural characteristics are compared to reference values for hot mix asphalt (HMA). A rutting sensitivity analysis was performed on two rehabilitation scenarios with recycled and conventional HMA structural overlays in different climatic conditions using the Mechanistic Empirical Pavement Design (MEPDG). The cold-recycled scenarios exhibited performance similar to that of HMA overlays for most cases. The exceptions were the cases with thin HMA wearing courses and/or very poor cold-recycled material quality. The overall conclusion is that properly designed CIR/FDR/CCPR cold-recycled materials are a viable alternative to virgin HMA materials.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load Introduction: Millions of people around the world do not have access to the benefits of osseointegration. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in the oral medicine field. This is an alternative therapy for retention and stability achievement in total prosthesis with conventional treatment, and two implants are enough to establish a satisfactory overdenture. Objective: The objectives of the study were to evaluate 16 patients of both sexes, with an average age of 47.4 +/- 4 years, using electromyographic analysis of masseter and temporal muscles and analyse the increase of incisive and molar maximal bite force with their existing complete dentures and following mandibular implant overdenture therapy to assess the benefits of this treatment. Materials and methods: For these tests, the Myosystem-BR1 electromyograph and the IDDK Kratos dynamometer were used. Statistical analysis was performed using the repeated measures test (SPSS 17.0). Results: A decrease in electromyographic activity during the rest, lateral and protrusion movements and increase of the maximal incisive and molar bite force after 15 months with a mandibular implant overdenture was observed. Conclusion: All the patients in this study reported a considerable improvement in the masticatory function and prostheses stability following treatment. It is possible to propose that the use of mandibular implants overdenture should become the selected treatment for totally edentulous patients to facilitate oral function and quality of life.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Symbol Digit Modalities Test (SDMT) is a widely used instrument to assess information processing speed, attention, visual scanning, and tracking. Considering that repeated evaluations are a common need in neuropsychological assessment routines, we explored test–retest reliability and practice effects of two alternate SDMT forms with a short inter-assessment interval. A total of 123 university students completed the written SDMT version in two different time points separated by a 150-min interval. Half of the participants accomplished the same form in both occasions, while the other half filled different forms. Overall, reasonable test–retest reliabilities were found (r = .70), and the subjects that completed the same form revealed significant practice effects (p < .001, dz = 1.61), which were almost non-existent in those filling different forms. These forms were found to be moderately reliable and to elicit a similar performance across participants, suggesting their utility in repeated cognitive assessments when brief inter-assessment intervals are required.