236 resultados para Radiofrequency Neurotomy
Resumo:
BACKGROUND Radiofrequency ablation (RFA) from the epicardial space for ventricular arrhythmias is limited or impossible in some cases. Reasons for epicardial ablation failure and the effect on outcome have not been systematically analyzed. METHODS AND RESULTS We assessed reasons for epicardial RFA failure relative to the anatomic target area and the type of heart disease and assessed the effect of failed epicardial RFA on outcome after ablation procedures for ventricular arrhythmias in a large single-center cohort. Epicardial access was attempted during 309 ablation procedures in 277 patients and was achieved in 291 procedures (94%). Unlimited ablation in an identified target region could be performed in 181 cases (59%), limited ablation was possible in 22 cases (7%), and epicardial ablation was deemed not feasible in 88 cases (28%). Reasons for failed or limited ablation were unsuccessful epicardial access (6%), failure to identify an epicardial target (15%), proximity to a coronary artery (13%), proximity to the phrenic nerve (6%), and complications (<1%). Epicardial RFA was impeded in the majority of cases targeting the left ventricular summit region. Acute complications occurred in 9%. The risk for acute ablation failure was 8.3× higher (4.5-15.0; P<0.001) after no or limited epicardial RFA compared with unlimited RFA, and patients with unlimited epicardial RFA had better recurrence-free survival rates (P<0.001). CONCLUSIONS Epicardial RFA for ventricular arrhythmias is often limited even when pericardial access is successful. Variability of success is dependent on the target area, and the presence of factors limiting ablation is associated with worse outcomes.
Resumo:
Issued May 1978.
Resumo:
Bibliography: p. 10.
Resumo:
In this paper, numerical simulations are used in an attempt to find optimal Source profiles for high frequency radiofrequency (RF) volume coils. Biologically loaded, shielded/unshielded circular and elliptical birdcage coils operating at 170 MHz, 300 MHz and 470 MHz are modelled using the FDTD method for both 2D and 3D cases. Taking advantage of the fact that some aspects of the electromagnetic system are linear, two approaches have been proposed for the determination of the drives for individual elements in the RF resonator. The first method is an iterative optimization technique with a kernel for the evaluation of RF fields inside an imaging plane of a human head model using pre-characterized sensitivity profiles of the individual rungs of a resonator; the second method is a regularization-based technique. In the second approach, a sensitivity matrix is explicitly constructed and a regularization procedure is employed to solve the ill-posed problem. Test simulations show that both methods can improve the B-1-field homogeneity in both focused and non-focused scenarios. While the regularization-based method is more efficient, the first optimization method is more flexible as it can take into account other issues such as controlling SAR or reshaping the resonator structures. It is hoped that these schemes and their extensions will be useful for the determination of multi-element RF drives in a variety of applications.
Resumo:
Objectives: To systematically review radiofrequency ablation (RFA) for treating liver tumors. Data Sources: Databases were searched in July 2003. Study Selection: Studies comparing RFA with other therapies for hepatocellular carcinoma (HCC) and colorectal liver metastases (CLM) plus selected case series for CLM. Data Extraction: One researcher used standardized data extraction tables developed before the study, and these were checked by a second researcher. Data Synthesis: For HCC, 1.3 comparative studies were included, 4 of which were randomized, controlled trials. For CLM, 13 studies were included, 2 of which were nonrandomized comparative studies and 11 that were case series. There did not seem to be any distinct differences in the complication rates between RFA and any of the other procedures for treatment of HCC. The local recurrence rate at 2 years showed a statistically significant benefit for RFA over percutaneous ethanol injection for treatment of HCC (6% vs 26%, 1 randomized, controlled trial). Local recurrence was reported to be more common after RFA than after laser-induced thermotherapy, and a higher recurrence rate and a shorter time to recurrence were dassociated with RFA compared with surgical resection (1 nonrandomized study each). For CLM, the postoperative complication rate ranged from 0% to 33% (3 case series). Survival after diagnosis was shorter in the CLM group treated with RFA than in the surgical resection group (1 nonrandomized study). The CLM local recurrence rate after RFA ranged from 4% to 55% (6 case series). Conclusions: Radiofrequency ablation may be more effective than other treatments in terms of less recurrence of HCC and may be as sale, although the evidence is scant. There was not enough evidence to determine the safety or efficacy of RFA for treatment of CLM.
Resumo:
Objectives: In contrast to other countries, surgery still represents the common invasive treatment for varicose veins in Germany. However, radiofrequency ablation, e.g. ClosureFast, becomes more and more popular in other countries due to potential better results and reduced side effects. This treatment option may cause less follow-up costs and is a more convenient procedure for patients, which could justify an introduction in the statutory benefits catalogue. Therefore, we aim at calculating the budget impact of a general reimbursement of ClosureFast in Germany. Methods: To assess the budget impact of including ClosureFast in the German statutory benefits catalogue, we developed a multi-cohort Markov model and compared the costs of a “World with ClosureFast” with a “World without ClosureFast” over a time horizon of five years. To address the uncertainty of input parameters, we conducted three different types of sensitivity analysis (one-way, scenario, probabilistic). Results: In the Base Case scenario, the introduction of the ClosureFast system for the treatment of varicose veins saves costs of about 19.1 Mio. € over a time horizon of five years in Germany. However, the results scatter in the sensitivity analyses due to limited evidence of some key input parameters. Conclusions: Results of the budget impact analysis indicate that a general reimbursement of ClosureFast has the potential to be cost-saving in the German Statutory Health Insurance.
Resumo:
The cavotricuspid isthmus (CTI) in the lower pan of the right atrium, between the inferior caval vein and the tricuspid valve, is considered crucial in producing a conduction delay and. hence, favoring the perpetuation of a reentrant circuit. Non-uniform wall thickness, muscle fiber orientation and the marked variability in muscular architecture in the CTI should be taken into consideration from the perspective of anisotropic conduction, thus producing an electrophysiologic isthmus. The purpose of this article is to review the anatomy and electrophysiology of the CTI in human hearts to provide useful information to plan CTI radio frequency ablation for the patients with atrial flutter.
Resumo:
We present a formalism for the analysis of sensitivity of nuclear magnetic resonance pulse sequences to variations of pulse sequence parameters, such as radiofrequency pulses, gradient pulses or evolution delays. The formalism enables the calculation of compact, analytic expressions for the derivatives of the density matrix and the observed signal with respect to the parameters varied. The analysis is based on two constructs computed in the course of modified density-matrix simulations: the error interrogation operators and error commutators. The approach presented is consequently named the Error Commutator Formalism (ECF). It is used to evaluate the sensitivity of the density matrix to parameter variation based on the simulations carried out for the ideal parameters, obviating the need for finite-difference calculations of signal errors. The ECF analysis therefore carries a computational cost comparable to a single density-matrix or product-operator simulation. Its application is illustrated using a number of examples from basic NMR spectroscopy. We show that the strength of the ECF is its ability to provide analytic insights into the propagation of errors through pulse sequences and the behaviour of signal errors under phase cycling. Furthermore, the approach is algorithmic and easily amenable to implementation in the form of a programming code. It is envisaged that it could be incorporated into standard NMR product-operator simulation packages.
Resumo:
Background: Procedural sedation and analgesia (PSA) administered by nurses in the cardiac catheterisation laboratory (CCL) is unlikely to yield serious complications. However, the safety of this practice is dependent on timely identification and treatment of depressed respiratory function. Aim: Describe respiratory monitoring in the CCL. Methods: Retrospective medical record audit of adult patients who underwent a procedure in the CCLs of one private hospital in Brisbane during May and June 2010. An electronic database was used to identify subjects and an audit tool ensured data collection was standardised. Results: Nurses administered PSA during 172/473 (37%) procedures including coronary angiographies, percutaneous coronary interventions, electrophysiology studies, radiofrequency ablations, cardiac pacemakers, implantable cardioverter defibrillators, temporary pacing leads and peripheral vascular interventions. Oxygen saturations were recorded during 160/172 (23%) procedures, respiration rate was recorded during 17/172 (10%) procedures, use of oxygen supplementation was recorded during 40/172 (23%) procedures and 13/172 (7.5%; 95% CI=3.59–11.41%) patients experienced oxygen desaturation. Conclusion: Although oxygen saturation was routinely documented, nurses did not regularly record respiration observations. It is likely that surgical draping and the requirement to minimise radiation exposure interfered with nurses’ ability to observe respiration. Capnography could overcome these barriers to respiration assessment as its accurate measurement of exhaled carbon dioxide coupled with the easily interpretable waveform output it produces, which displays a breath-by-breath account of ventilation, enables identification of respiratory depression in real-time. Results of this audit emphasise the need to ascertain the clinical benefits associated with using capnography to assess ventilation during PSA in the CCL.
Resumo:
In the fields of organic electronics and biotechnology, applications for organic polymer thin films fabricated using low-temperature non-equilibrium plasma techniques are gaining significant attention because of the physical and chemical stability of thin films and the low cost of production. Polymer thin films were fabricated from non-synthetic terpinen-4-ol using radiofrequency polymerization (13.56 MHz) on low loss dielectric substrates and their permittivity properties were ascertained to determine potential applications for these organic films. Real and imaginary parts of permittivity as a function of frequency were measured using the variable angle spectroscopic ellipsometer. The real part of permittivity (k) was found to be between 2.34 and 2.65 in the wavelength region of 400–1100 nm, indicating a potential low-k material. These permittivity values were confirmed at microwave frequencies. Dielectric properties of polyterpenol films were measured by means of split post dielectric resonators (SPDRs) operating at frequencies of 10 GHz and 20 GHz. Permittivity increased for samples deposited at higher RF energy – from 2.65 (25 W) to 2.83 (75 W) measured by a 20-GHz SPDR and from 2.32 (25 W) to 2.53 (100 W) obtained using a 10-GHz SPDR. The error in permittivity measurement was predominantly attributed to the uncertainty in film thickness measurement.
Resumo:
Breast cancer is the most common form of potentially fatal cancer in women in the Western world. Better understanding of the breast cancer disease process together with developments in treatments have led to improved survival and reduced risk of recurrence, significantly influencing the acceptance of breast reconstructions as part of breast cancer treatment. Skin-sparing mastectomy followed by immediate breast reconstruction has proved superior to other forms of breast reconstruction in terms of aesthetic outcome. However, due to the relatively recent introduction of skin-sparing mastectomy concerns on the surgical and oncological safety of the operation persist. The aim of the present study is to evaluate the surgical and oncological safety of skin-sparing mastectomy and immediate breast reconstruction in a consecutive patient series with ensuing follow-up. Subsequent aims of the study are to examine possibilities of reducing surgical complications of the operation and to assess the feasibility of sentinel node biopsy together with immediate breast reconstruction. The study population comprises a consecutive series of patients having undergone skin-sparing mastectomy followed by immediate breast reconstruction at the Helsinki University Central Hospital between 1992 and 2006. In Study I, the hospital records of 207 patients, operated between 1992 and 2001, were analyzed for surgical complications and recurrences of breast cancer during follow-up. In Study II, 60 consecutive patients were randomized into either conventional diathermy or radiofrequency coagulation groups to examine possibilities of reducing skin-flap complications. Study III consists of 62 consecutive breast cancer patients evaluated for the feasibility of sentinel node biopsy simultaneously with immediate breast reconstruction. In Study IV, hospital records were analyzed to examine local recurrence of breast cancer in a consecutive series of 146 patients with Stage I or II disease. Post-operative complications in Study I included native skin-flap necrosis (10.1%), hematoma (10.1%), anastomose thrombosis (5.3%), infection (3.4%), hernia (2.6%) and loss of one microvascular flap (0.7%). The Stage I and II patients in Study IV had a local recurrence rate of 2.7%, an isolated regional lymph node recurrence rate of 2.1% and a systemic recurrence rate of 2.7%, during a mean follow-up time of 51 months. The Stage III patients in study I had a locoregional recurrence rate of 31.3% during follow-up. Radiofrequency coagulation in Study II did not decrease skin-flap complications when compared with conventional diathermy. An increased skin-flap complication rate in Study II was associated with smoking and the type of skin incision used. In Study III, eleven patients had tumor positive sentinel nodes, nine of which were detected intraoperatively. Skin-sparing mastectomy followed by immediate breast reconstruction is a safe procedure both surgically and oncologically, especially for early stage breast cancer. Tennis racket type incision is associated with an increased skin-flap complication rate. Sentinel node biopsy with intraoperative assessment of sentinel node metastases is feasible in patients undergoing immediate breast reconstruction.
Resumo:
[ES]En este documento se realiza el diseño de un procedimiento para la validación de los equipos necesarios a la hora de implantar un sistema de control de acceso mediante RFID pasivo. Para ello, se analizarán los distintos tipos de sistemas RFID y se elige uno para la posterior adquisición de los dispositivos necesarios. Se comprobará la normativa vigente ETSI, que regula las emisiones de potencia de los equipos de identificación por radiofrecuencia, y se verificará que se cumplen los requisitos necesarios para implantar el sistema de control de acceso realizando un análisis funcional en situaciones reales.
Resumo:
This thesis describes investigations of two classes of laboratory plasmas with rather different properties: partially ionized low pressure radiofrequency (RF) discharges, and fully ionized high density magnetohydrodynamically (MHD)-driven jets. An RF pre-ionization system was developed to enable neutral gas breakdown at lower pressures and create hotter, faster jets in the Caltech MHD-Driven Jet Experiment. The RF plasma source used a custom pulsed 3 kW 13.56 MHz RF power amplifier that was powered by AA batteries, allowing it to safely float at 4-6 kV with the cathode of the jet experiment. The argon RF discharge equilibrium and transport properties were analyzed, and novel jet dynamics were observed.
Although the RF plasma source was conceived as a wave-heated helicon source, scaling measurements and numerical modeling showed that inductive coupling was the dominant energy input mechanism. A one-dimensional time-dependent fluid model was developed to quantitatively explain the expansion of the pre-ionized plasma into the jet experiment chamber. The plasma transitioned from an ionizing phase with depressed neutral emission to a recombining phase with enhanced emission during the course of the experiment, causing fast camera images to be a poor indicator of the density distribution. Under certain conditions, the total visible and infrared brightness and the downstream ion density both increased after the RF power was turned off. The time-dependent emission patterns were used for an indirect measurement of the neutral gas pressure.
The low-mass jets formed with the aid of the pre-ionization system were extremely narrow and collimated near the electrodes, with peak density exceeding that of jets created without pre-ionization. The initial neutral gas distribution prior to plasma breakdown was found to be critical in determining the ultimate jet structure. The visible radius of the dense central jet column was several times narrower than the axial current channel radius, suggesting that the outer portion of the jet must have been force free, with the current parallel to the magnetic field. The studies of non-equilibrium flows and plasma self-organization being carried out at Caltech are relevant to astrophysical jets and fusion energy research.
Resumo:
Part I.
The interaction of a nuclear magnetic moment situated on an internal top with the magnetic fields produced by the internal as well as overall molecular rotation has been derived following the method of Van Vleck for the spin-rotation interaction in rigid molecules. It is shown that the Hamiltonian for this problem may be written
HSR = Ῑ · M · Ĵ + Ῑ · M” · Ĵ”
Where the first term is the ordinary spin-rotation interaction and the second term arises from the spin-internal-rotation coupling.
The F19 nuclear spin-lattice relaxation time (T1) of benzotrifluoride and several chemically substituted benzotrifluorides, have been measured both neat and in solution, at room temperature by pulsed nuclear magnetic resonance. From these experimental results it is concluded that in benzotrifluoride the internal rotation is crucial to the spin relaxation of the fluorines and that the dominant relaxation mechanism is the fluctuating spin-internal-rotation interaction.
Part II.
The radiofrequency spectrum corresponding to the reorientation of the F19 nuclear moment in flurobenzene has been studied by the molecular beam magnetic resonance method. A molecular beam apparatus with an electron bombardment detector was used in the experiments. The F19 resonance is a composite spectrum with contributions from many rotational states and is not resolved. A detailed analysis of the resonance line shape and width by the method of moments led to the following diagonal components of the fluorine spin-rotational tensor in the principal inertial axis system of the molecule:
F/Caa = -1.0 ± 0.5 kHz
F/Cbb = -2.7 ± 0.2 kHz
F/Ccc = -1.9 ± 0.1 kHz
From these interaction constants, the paramagnetic contribution to the F19 nuclear shielding in C6H5F was determined to be -284 ± ppm. It was further concluded that the F19 nucleus in this molecule is more shielded when the applied magnetic field is directed along the C-F bond axis. The anisotropy of the magnetic shielding tensor, σ” - σ⊥, is +160 ± 30 ppm.
Resumo:
A maioria dos pacientes que apresentam metástases hepáticas colorretais (MHCR) não são elegíveis para ressecção. Por isso, outras técnicas para se alcançar o controle locorregional da doença têm sido utilizadas. A Ablação por Radiofrequência (ARF) hepática tem sido empregada frequentemente para o tratamento desta condição devido às boas taxas de resposta, principalmente quando associada ao emprego de quimioterápicos modernos. Apesar da caracterização das MHCR no pré-operatório estar bem estabelecida, os parâmetros de ressonância magnética (RM) após ARF no período pós-cirúrgico requerem maior padronização objetiva. O coeficiente de difusão aparente de água (CDA) tem sido usado na RM como um parâmetro de isquemia e necrose. Entretanto, não está ainda bem definido seu papel e das imagens ponderadas de difusão (DWI) na avaliação da necrose coagulativa gerada pela ARF, especificamente em pacientes com MHCR. O objetivo deste estudo consiste em avaliar o espectro de mudança em RM funcional após a ARF de MHCR. Foi realizado estudo retrospectivo entre 2001 e 2006, avaliando 51 pacientes que foram submetidos à ARF por MHCR no Hospital Johns Hopkins (Baltimore, EUA) dos quais 16 preencheram os critérios de inclusão. Os critérios de inclusão foram: (1) apresentar MHCR tratada cirurgicamente com intenção curativa por ARF guiados por ultrassom per-operatório, e (2) ter uma RM anterior e imediatamente após a cirurgia (até 10 dias). As imagens de RMs antes e após a ablação hepática para MCHR foram identificadas e revistas. As imagens de RM de difusão e captação de contraste foram feitas numa unidade de 1.5 T. Imagens em T2 e T1 foram realizadas na presença e ausência de contraste venoso. Todos os exames tiveram a espessura de 4 a 6 mm e um intervalo de 2 mm, apresentando um angulo de rotação de 150. O índice de difusão foi determinado com um b-valor (intensidade do gradiente de difusão) de 500 seg/mm2. As análises de parâmetros para avaliar e comparar o pré e pós ARF através da RM funcional incluiram: (1) valores do mapa de CDA, (2) captação de contraste, (3) difusão e (4) mudança no tamanho da lesão. Em adição, a sobrevida mediana global e tempo para recorrência local foram calculados. As imagens foram avaliadas por um consenso de dois radiologistas/cirurgiões. Foram avaliados no total 65 lesões, com tamanho médio pré-ablação de 1,7 cm. Após ablação o tamanho médio da lesão aumentou para 3,5 cm (p<0,001). A captação de contraste nas fases arterial e venosa diminuíram significativamente após ARF (diminuição média 10% e 17,5%, respectivamente, p = 0,002 e <0,001). O valor médio do mapa de CDA da lesão foi de 2.79 x 10-3 mm2/seg pré-ARF, e após ARF diminui em média para 1.75 x 10-3 mm2/seg (p<0.001). A sobrevida mediana global foi de 34,7 meses. A ressonância magnética funcional através da captação de contraste e difusão pode prover uma estimativa subjetiva e objetiva da necrose coagulativa tissular e da desidratação celular na área ablada por radiofrequência. Quando combinada ao aumento no tamanho do tumor, podem atuar como um marcador adicional de resposta tumoral.