994 resultados para Qualidade de tensão
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
This paper presents a technique to add flexibility in the control of power electronic converters. The power converter can function as an active power filter, as a local power source interface or perform both functions i. e. mitigate current disturbances and inject power into the grid simultaneously, configuring it as a multifunctional device. The main goal is to extract the full capability of the grid connected power electronic converter to achieve maximum benefits. To achieve this goal, the orthogonal current decomposition of the Conservative Power Theory is used. Each orthogonal current component is weighted by means of different compensation factors (k_i), which are set instantaneously and independently, in any percentage by means of the load performance factors (λ_i), providing an online flexibility in relation to compensation objectives. Finally, to validate the effectiveness and performance the proposed approach, simulations and experimental results are presented.
Resumo:
Pós-graduação em Psicologia do Desenvolvimento e Aprendizagem - FC
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
With the progress of devices technology, generation and use of energy ways, power quality parameters start to influence more significantly the various kinds of power consumers. Currently, there are many types of devices that analyze power quality. However, there is a need to create devices, and perform measurements and calculate parameters, find flaws, suggest changes, and to support the management of the installation. In addition, you must ensure that such devices are accessible. To maintain this balance, one magnitude measuring method should be used which does not require great resources processing or memory. The work shows that application of the Goertzel algorithm, compared with the commonly used FFT allows measurements to be made using much less hardware resources, available memory space to implement management functions. The first point of the work is the research of troubles that are more common for low voltage consumers. Then we propose the functional diagram indicate what will be measured, calculated, what problems will be detected and that solutions can be found. Through the Goertzel algorithm simulation using Scilab, is possible to calculate frequency components of a distorted signal with satisfactory results. Finally, the prototype is assembled and tests are carried out by adjusting the parameters necessary for one to maintain a reliable device without increasing its cost.
Resumo:
The increasing demand in electricity and decrease forecast, increasingly, of fossil fuel reserves, as well as increasing environmental concern in the use of these have generated a concern about the quality of electricity generation, making it well welcome new investments in generation through alternative, clean and renewable sources. Distributed generation is one of the main solutions for the independent and selfsufficient generating systems, such as the sugarcane industry. This sector has grown considerably, contributing expressively in the production of electricity to the distribution networks. Faced with this situation, one of the main objectives of this study is to propose the implementation of an algorithm to detect islanding disturbances in the electrical system, characterized by situations of under- or overvoltage. The algorithm should also commonly quantize the time that the system was operating in these conditions, to check the possible consequences that will be caused in the electric power system. In order to achieve this it used the technique of wavelet multiresolution analysis (AMR) for detecting the generated disorders. The data obtained can be processed so as to be used for a possible predictive maintenance in the protection equipment of electrical network, since they are prone to damage on prolonged operation under abnormal conditions of frequency and voltage.
Resumo:
Brazil is the third largest producer and exporter of turkey meat, especially in Paraná state, with the largest production volume. In worldwide the animal welfare is a prerequisite for food quality of animal origin, especially in Europe. The Regulation of European Community No 1099/2009 provides requirements for poultry stunning that associate with animal welfare as a means to minimize the pain and suffering from the slaughter. Improper application of callousness should produce low-quality meat, and significant industry losses. This Research aimed to evaluate the impacts on the quality of meat from turkeys, applying electrical stunning parameters established in the Regulation No 1099/2009 of the Council of 24 September 2009. Was applied an outline with 8 tests set equidistantly to frequency, and set parameters for current and voltage, and a control test. Were conducted qualitative assessments of hematoms and bruises / fractures in carcasses, hematoms, blood splashed and bleeding in turkey breast, and quantitative pH, color (L *), water holding capacity and shear force in turkey breast. The individual assessments showed no significant difference (p>0,05). In multivariate cluster analysis was the formation of two distinct groups: group 1 - 50 Hz to 200 Hz (low frequency) and group 2 - 633 Hz to 1500 Hz (high frequency), which showed significant difference (p= 0,016). In principal component analysis multivariate, the group 1 tend to have a higher incidence of bruising, blood splashed, bleeding and water holding capacity in breast turkeys, and bruises / fractures and hematoms on carcasses. The Group 2 tends to have a lower incidence of these parameters, and higher pH values, shear force and color (L *). Positive correlation was obtained for the parameters pH and shear force (r= 0.7506, p=0.0198); bleeding and splashed blood (r= 0.8811, p= 0.0017), and negative correlation to color (L*) and splashed blood on breast (r= -0.7889; p= 0.0115); breast hematoms and shear force (r= -0.7844; p= 0.0123). It has been observed that at lower frequencies stunning tends to have higher incidence of defects in the carcasses and turkey breast. The use of high frequencies in stunning, create smaller quantity of trimming, and an increase in turkey breast volume produced, with a financial gain of approximately R$250,000.00 / year. Moreover, there is no need increase the workers to do the trimming tasks and, therefore, higher financial results for companies. Therefore, we recommend the use of high frequencies in the stunning of turkeys.
Resumo:
A retificação, processo final de usinagem de uma peça, utiliza fluidos de corte com a finalidade de lubrificação, refrigeração e remoção de cavacos. No entanto, esses fluidos são extremamente agressivos com o meio. Com o avanço tecnológico a tendência mundial é produzir peças cada vez mais sofisticadas, com elevado grau de tolerância geométrica, dimensional, com bom acabamento superficial, com baixo custo e, principalmente, sem causar danos ao meio. Para tanto, ao processo de retificação está intrínseca a reciclagem do fluido de corte, que se destaca pelo seu custo. Através da variação da velocidade de avanço no processo de retificação cilíndrica externa do aço ABNT D6, racionalizando a aplicação de dois fluidos de corte e usando um rebolo superabrasivo de CBN (nitreto de boro cúbico) com ligante vitrificado, avaliaram-se os parâmetros de saída da força tangencial de corte, emissão acústica, rugosidade, circularidade, desgaste da ferramenta, tensão residual e a integridade superficial através da microscopia eletrônica de varredura (MEV) dos corpos-de-prova. Com a análise do desempenho do fluido, do rebolo e da velocidade de mergulho, encontraram-se as melhores condições de usinagem propiciando a diminuição do volume de fluido de corte e a diminuição do tempo de usinagem, sem prejudicar os parâmetros geométricos e dimensionais, o acabamento superficial e a integridade superficial dos componentes.
Resumo:
Dissertação de Mestrado, Engenharia Elétrica e Eletrónica, Especialização em Sistemas de Energia e Controlo, Instituto Superior de Engenharia, Universidade do Algarve, 2015
Resumo:
Dissertação mest. em Imagiologia Médica, Faculdade de Ciências e Tecnologia da Univ. do Algarve, 2006
Resumo:
A irrigação tem sido empregada em diversas regiões do mundo na produção de uvas de mesa. No Brasil, o seu emprego tem sido mais comum nas áreas tropicais do país, como no Vale do São Francisco, no Norte de Minas Gerais, no Noroeste Paulista e nas novas áreas vitícolas do Espírito Santo, Rio de Janeiro, Goiás e oeste de São Paulo. Por outro lado, nas regiões de clima temperado do Sul do Brasil, vários produtores de uvas de mesa também têm utilizado a irrigação em seus vinhedos, especialmente em cultivos protegidos com cobertura plástica. Para que a irrigação possa ser utilizada com eficácia, deve-se manter a umidade no solo em níveis adequados para a cultura e evitar aplicações excessivas, que podem levar a desperdícios de água e energia, bem como prejudicar a qualidade dos frutos. Vários critérios podem ser adotados, com esse objetivo, sendo o monitoramento da tensão da água no solo um dos métodos mais empregados pelos viticultores em áreas irrigadas. Este documento apresenta uma revisão com os principais resultados da literatura especializada, sobre o uso da tensão da água no solo como base do manejo da irrigação em áreas produtoras de uvas de mesa. A Embrapa Uva e Vinho espera que essas informações possam servir de subsídio para uma viticultura mais sustentável e para o uso mais eficiente dos recursos hídricos, cada vez mais escassos.