975 resultados para Pupil Size


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate that it is possible to reduce the focal spot size by inserting a uniform nonlinear thin film at the aperture of a focusing lens. The reduction of spot size is tunable by adjusting the incoming laser power. In comparison with the original diffraction spot, the transverse spot size can be reduced 0.65 times. The nonlinear thin film acts effectively as a Toraldo filter, and the phase and amplitude modulation stems from the laser-induced variances in the transmission of the thin film. The proposed technique removes the need of fabricating annular pupil filters. (C) 2008 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the last decade, television screens and display monitors have increased in size considerably, but has this improved our televisual experience? Our working hypothesis was that the audiences adopt a general strategy that “bigger is better.” However, as our visual perceptions do not tap directly into basic retinal image properties such as retinal image size (C. A. Burbeck, 1987), we wondered whether object size itself might be an important factor. To test this, we needed a task that would tap into the subjective experiences of participants watching a movie on different-sized displays with the same retinal subtense. Our participants used a line bisection task to self-report their level of “presence” (i.e., their involvement with the movie) at several target locations that were probed in a 45-min section of the movie “The Good, The Bad, and The Ugly.” Measures of pupil dilation and reaction time to the probes were also obtained. In Experiment 1, we found that subjective ratings of presence increased with physical screen size, supporting our hypothesis. Face scenes also produced higher presence scores than landscape scenes for both screen sizes. In Experiment 2, reaction time and pupil dilation results showed the same trends as the presence ratings and pupil dilation correlated with presence ratings, providing some validation of the method. Overall, the results suggest that real-time measures of subjective presence might be a valuable tool for measuring audience experience for different types of (i) display and (ii) audiovisual material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a prototype tracking system for tracking people in enclosed indoor environments where there is a high rate of occlusions. The system uses a stereo camera for acquisition, and is capable of disambiguating occlusions using a combination of depth map analysis, a two step ellipse fitting people detection process, the use of motion models and Kalman filters and a novel fit metric, based on computationally simple object statistics. Testing shows that our fit metric outperforms commonly used position based metrics and histogram based metrics, resulting in more accurate tracking of people.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method of eye localisation and face segmentation for use in a face recognition system. By using two near infrared light sources, we have shown that the face can be coarsely segmented, and the eyes can be accurately located, increasing the accuracy of the face localisation and improving the overall speed of the system. The system is able to locate both eyes within 25% of the eye-to-eye distance in over 96% of test cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organisations invest enormous sums of money in acquiring Enterprise Resource Planning (ERP) systems, presumably expecting positive impacts to the organisation and its functions. Despite the optimistic motives some ERP projects have reported nil or detrimental impacts. This paper studies the proposition that the size of an organisation (e.g. small, large) may have contributed to the differences in receiving benefits reported in prior studies in this domain. The alleged differences in organisational performance are empirically measured using a prior validated model, using five constructs and fortytwo sub-constructs. Information is gathered from three hundred and ten respondents representing twenty-seven public sector organisations. Results suggests that (1) larger organisations have received more benefits compared to small organisations, (2) small organisations demonstrated higher reliance on their ERP systems, (3) employment cohorts demonstrate significant differences in perceived benefits in small and large organisations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Size distributions of expiratory droplets expelled during coughing and speaking and the velocities of the expiration air jets of healthy volunteers were measured. Droplet size was measured using the Interferometric Mie imaging (IMI) technique while the Particle Image Velocimetry (PIV) technique was used for measuring air velocity. These techniques allowed measurements in close proximity to the mouth and avoided air sampling losses. The average expiration air velocity was 11.7 m/s for coughing and 3.9 m/s for speaking. Under the experimental setting, evaporation and condensation effects had negligible impact on the measured droplet size. The geometric mean diameter of droplets from coughing was 13.5m and it was 16.0m for speaking (counting 1 to 100). The estimated total number of droplets expelled ranged from 947 – 2085 per cough and 112 – 6720 for speaking. The estimated droplet concentrations for coughing ranged from 2.4 - 5.2cm-3 per cough and 0.004 – 0.223 cm-3 for speaking.