958 resultados para Pin on disc tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A vertical pin on horizontal disc machine has been used to conduct a series of experiments in air under dry and lubricating sliding conditions. For dry sliding low load and speed combinations were chosen to correspond to the mild wear region below the Welsh T1 transition. Lubricated tests were conducted under flooded conditions using Esso Technical White Oil alone and with a 0.1% stearic acid additive, for load and speed ranges that produced substantial amounts of asperity contact and thus a boundary lubricated regime of wear. The test material in all cases was AISI 52100 steel, for unlubricated sliding subjected to loads from 5 to 50 N and a range of speeds from 10-3 to 1.0 ms-1, and for lubricated sliding loads of 50 to 123 N and for speeds of 10-2 to 1.0 ms-1. Unlubricated wear debris was found to be a mixture of -Fe_2O_3 and -Fe. Unlubricated wear was found to occur via a thin film logarithmic oxide growth followed by agglomeration into thicker oxide plateaux 2 to 10 m in thickness. Lubricated wear occurred via thick film diffusion controlled oxide growth producing homogeneous oxide plateaux 0.1 to 0.2 m in thickness. X-ray photoelectron spectroscopy identified the presence of a surface film on pins worn in White Oil with stearic acid, which is thought to be iron stearate. A model has been developed for unlubricated wear based upon the postulated growth of thin film oxides by a logarithmic rate law. The importance of sliding geometry and environment to the dominant wear mechanism has been illustrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of cobalt molybdenum and cobalt tungsten brush plating electrolytes is described. Their optimum compositions and operating conditions for commercial applications have been determined. The effects of composition, pH, applied voltage, stylus speed and pressure upon deposit composition and efficiency have been investigated. Transmission and Scanning Electron Microscopy have been employed to study the cobalt alloy deposits produced. Evaluation of the wear resistant properties of the cobalt alloys developed in this work was carried out in the laboratory using a pin and disc technique and a simulated hot forging test, and by industrial trials involving the "on site" plating of hot forging dies and cold pressing tools. It was concluded that the electrolytes developed in tl1is work enabled cobalt alloys containing 6% Mo or 8% W to be deposited at 17-20V. Brush plated cobalt deposits possessed a mixed CPU and FCC crystallographic structure at room temperature. The application of 13µm of either of the cobalt alloys resulted in improved wear performance in both pin and disc and simulated hot forging tests. The results of the industrial trials indicated that by the use of these alloys, the life of hot forging dies may be increased by 20-100%. A commercial forging organisation is using electrolytes developed in this work to coat dies prior to forging nimonic alloys. Reductions in forging temperature and improved forging qualities have been reported. Cold pressing tools coated with the alloys showed a reduced tendency to "pick-up" and scoring of the pressed panels. Reports of a reduced need for lubrication of panels before pressing have also been received.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, the development of industrial processes brought on the outbreak of technologically complex systems. This development generated the necessity of research relative to the mathematical techniques that have the capacity to deal with project complexities and validation. Fuzzy models have been receiving particular attention in the area of nonlinear systems identification and analysis due to it is capacity to approximate nonlinear behavior and deal with uncertainty. A fuzzy rule-based model suitable for the approximation of many systems and functions is the Takagi-Sugeno (TS) fuzzy model. IS fuzzy models are nonlinear systems described by a set of if then rules which gives local linear representations of an underlying system. Such models can approximate a wide class of nonlinear systems. In this paper a performance analysis of a system based on IS fuzzy inference system for the calibration of electronic compass devices is considered. The contribution of the evaluated IS fuzzy inference system is to reduce the error obtained in data acquisition from a digital electronic compass. For the reliable operation of the TS fuzzy inference system, adequate error measurements must be taken. The error noise must be filtered before the application of the IS fuzzy inference system. The proposed method demonstrated an effectiveness of 57% at reducing the total error based on considered tests. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work considers a nonlinear time-varying system described by a state representation, with input u and state x. A given set of functions v, which is not necessarily the original input u of the system, is the (new) input candidate. The main result provides necessary and sufficient conditions for the existence of a local classical state space representation with input v. These conditions rely on integrability tests that are based on a derived flag. As a byproduct, one obtains a sufficient condition of differential flatness of nonlinear systems. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the volume of the hippocampus and parahippocampal gyrus in elderly individuals with and without depressive disorders, and to determine whether the volumes of these regions correlate with scores on memory tests. Method: Clinical and demographic differences, as well as differences in regional gray matter volumes, were assessed in 48 elderly patients with depressive disorders and 31 control subjects. Brain (structural MRI) scans were processed using statistical parametric mapping and voxel-based morphometry. Cognitive tests were administered to subjects in both groups. Results: There were no between-group gray matter volume differences in the hippocampus or parahippocampal gyrus. In the elderly depressed group only, the volume of the left parahippocampal gyrus correlated with scores on the delayed naming portion of the visual verbal learning test. There were also significant direct correlations in depressed subjects between the volumes of the left hippocampus, right and left parahippocampal gyrus and immediate recall scores on verbal episodic memory tests and visual learning tests. In the control group, there were direct correlations only between overall cognitive performance (as assessed with the MMSE) and the volume of right hippocampus, and between the total score on the visual verbal learning test and the volume of the right and left parahippocampal gyrus. Conclusions: These findings highlight different patterns of relationship between cognitive performance and volumes of medial temporal structures in depressed individuals and healthy elderly subjects. The direct correlation between delayed visual verbal memory recall scores with left parahippocampal volumes specifically in elderly depressed individuals provides support to the view that depression in elderly populations may be a risk factor for dementia. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O coeficiente de atrito e o desgaste nas superligas de cobalto são fortemente influenciados pela transformação de fase de CFC para HC que ocorre devido ao trabalho mecânico, conforme já reportado pela literatura. Após essa transformação, os valores de μ costumam se situar na faixa de 0,15 a 0,20. Este trabalho apresenta o comportamento do atrito e do desgaste em um ensaio de deslizamento sem lubrificação utilizando uma configuração pino-disco, sendo o pino feito de aço inoxidável supermartensítico e o disco de uma superliga de cobalto fundida, num tribômetro PLINT TE67. Os ensaios foram conduzidos em temperatura ambiente, com uma velocidade e variando-se a carga normal de deslizamento entre 5 e 500 N. O coeficiente de atrito e o potencial elétrico de contato foram monitorados durante os ensaios. Utilizou-se a MEV e a perfilometria 3D para caracterizar o volume e o mecanismo de desgaste. Para as cargas de 350, 400 e 450 N, após atingir condições de regime estacionário, um valor de coeficiente de atrito não usual (μ<0,01) e uma baixa taxa de desgaste foram encontradas. A análise da difração de raios-X revelou a presença de transformação de fases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pond-breeding amphibians are affected by site-specific factors and regional and landscape-scale patterns of land use. Recent anthropogenic landscape modifications (drainage, agriculture intensification, larger road networks, and increased traffic) affect species by reducing the suitable habitat area and fragmenting remaining populations. Using a robust concentric approach based on permutation tests, we evaluated the impact of recent landscape changes on the presence of the endangered European tree frog (Hyla arborea.) in wetlands. We analyzed the frequency of 1 traffic and 14 land-use indices at 20 circular ranges (from 100-m up to 2-km radii) around 76 ponds identified in western Switzerland. Urban areas and road surfaces had a strong adverse effect on tree frog presence even at relatively great distances (from 100 m up to 1 km). When traffic measurements were considered instead of road surfaces, the effect increased, suggesting a negative impact due to a vehicle-induced effect. Altogether, our results indicate that urbanization and traffic must be taken into account when pond creation is an option in conservation management plans, as is the case for the European tree frog in western Switzerland. We conclude that our easy-to-use and robust concentric method of analysis can successfully assist managers in identifying potential sites for pond creation, where probability of the presence of tree frogs is maximized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary purpose of this study was to investigate the effect of skate blade shape on skating performance. A secondary purpose was to evaluate if a change in hollow shape can create additional effects on skating performance. Thirty-seven male ice hockey players (age=18 years, SD=3.4) participated. The intervention consisted of four sharpening trials assessed using three on-ice tests. Participant feedback was also assessed using a Likert scale questionnaire. Statistical analysis included within-subject repeated measures MANOVA of trial by skating variables (p≤0.05). Results revealed Contour 1 enhanced performance compared to baseline on six variables at varsity level and five variables at midget level. Contour 1 enhanced performance compared to Contour 2 on six variables at the varsity and midget levels. Contour 1 also scored highest on the feedback questionnaire. Findings of this study indicate that contouring is a necessary practice to achieve optimal skating performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines the vocabulary responses of hearing impaired children on standardized tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two simulative test methods were used to study galling in sheet forming of two types of stainlesssteel sheet: austenitic (EN 1.4301) and lean duplex LDX 2101 (EN 1.4162) in different surface conditions. Thepin-on-disc test was used to analyse the galling resistance of different combinations of sheet materials and lubricants. The strip reduction test, a severe sheet forming tribology test was used to simulate the conditionsduring ironing. This investigation shows that the risk of galling is highly dependent on the surface texture of theduplex steel. Trials were also performed in an industrial tool used for high volume production of pumpcomponents, to compare forming of LDX 2101 and austenitic stainless steel with equal thickness. The forming forces, the geometry and the strains in the sheet material were compared for the same component.It was found that LDX steels can be formed to high strain levels in tools normally applied for forming ofaustenitic steels, but tool adaptations are needed to comply with the higher strength and springback of thematerial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O primeiro registro para o Atlântico Sul ocidental de uma espécie do gênero Malacoraja Stehmann, 1970 é feita com base na descrição de Malacoraja obscura, espécie nova, proveniente do talude continental do Sudeste brasileiro dos estados do Espírito Santo e Rio de Janeiro em profundidades de 808-1105 m. A espécie nova é conhecida através de cinco exemplares e é distinta de seus congêneres pela sua coloração dorsal composta por numerosas manchas esbranquiçadas e pequenas na região do disco e nadadeiras pélvicas, por apresentar uma fileira irregular de espinhos ao longo da superfície dorsal mediana da cauda a qual persiste em espécimes maiores (desde a base da cauda até dois-terços do seu comprimento numa fêmea de 680 mm de comprimento total, CT) e uma região pequena desprovida de dentículos na base ventral da cauda (estendendo somente até a margem distal da nadadeira pélvica). Outros caracteres diagnósticos em combinação incluem a ausência de espinhos escapulares em indivíduos maiores, número elevado de fileiras dentárias (64/62 fileiras num macho subadulto de 505 mm de CT e 76/74 numa fêmea de 680 mm de CT) e de vértebras (27-28 Vtr, 68-75 Vprd), coloração ventral do disco uniformemente castanha escura, duas fenestras pós-ventrais na cintura escapular, fenestra pós-ventral posterior grande, forame magno circular e dois forames para a carótida interna na placa basal ventral do neurocrânio. Machos adultos não são conhecidos, porém uma descrição anatômica de M. obscura, sp. nov., é fornecida. Comparações são realizadas com todo o material conhecido de M. kreffti, com a literatura sobre M. senta e com material abundante de M. spinacidermis da África do Sul; M. obscura, sp. nov., assemelha-se mais a M. spinacidermis do Atlântico Sul oriental em esqueleto dérmico, coloração e tamanho. Malacoraja é monofilético devido à sua espinulação e apêndices rostrais conspícuos e é aparentemente composta por dois grupos de espécies, um para M. obscura e M. spinacidermis e outro para M. kreffti e M. senta, porém a elucidação das relações filogenéticas entre as espécies necessita de mais informações anatômicas, principalmente das duas últimas espécies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal spray WC-based coatings are widely used in the aircraft industry mainly for their resistance to wear, reworking and rebuilding operations and repair of worn components on landing gear, hydraulic cylinders, actuators, propeller hub assemblies, gas turbine engines, and so on. The aircraft industry is also trying to use thermal spray technology to replace electroplating coatings such as hard chromium. In the present work, WC-Co coatings were built up on an AA 7050 aluminum alloy using high velocity oxygen fuel (HVOF) technology and a liquid nitrogen cooling prototype system. The influence of the spray parameters (standard conditions, W19S, increasing the oxygen flux, W19H, and also increasing the carrier gas flux, W19F) on corrosion, friction, and abrasive wear resistance were also studied. The coatings were characterized using optical (OM) and scanning electron (SEM) microscopy, and X-ray diffraction (XRD). The friction and abrasive wear resistance of the coatings were studied using Rubber Wheel and Ball on Disk tests. The electrochemical studies were conducted using open-circuit potential (E(oc)) measurements and electrochemical impedance spectroscopy (EIS). Differences among coated samples were mainly related to the variation of the thermal spray parameters used during the spray process. No significant differences were observed in the wear resistance for the coatings studied, and all of them showed a wear rate around 10 times lower than that of the aluminum alloy. The results of mass loss and wear rate were interpreted considering different mechanisms. Comparing the different spray parameters, the oxygen flux (higher flame temperature) produced the sample which showed the highest corrosion resistance in aerated and unstirred 3.5% NaCl solution. Aluminum ions were detected on the surface almost immediately after the immersion of samples W19S and W19F in chloride solution, showing that the electrolyte reached the substrate and galvanic corrosion probably occurred. For sample W19H, aluminum ions were not detected even after 120 min of immersion in NaCl solution. (C) 2008 Elsevier B.V. All rights reserved.