835 resultados para Physiological and sensory quality
Resumo:
Salt use in meat products is changing. Consumers desire sea salt which may also contain trace metals and the government is demanding a reduction in sodium. Therefore a need exists to understand how varying impurity levels in salt affect meat quality. This study evaluated the effects of various salt preparations on lipid oxidation, sensory characteristics, protein extractability, and bind strength of ground turkey and pork. This study was a completely randomized design with 5 treatment groups and 6 replications in 2 species. Ground, turkey and pork meat was formulated into one hundred and fifty gram patties with sodium chloride (1%) containing varying amounts of metal impurities (copper, iron, and manganese). Samples were randomly assigned to frozen storage periods of 0, 3, 6, and 9 weeks. After storage, samples were packaged in PVC overwrap and stored under retail display for 5 days. Samples were evaluated for proximate analysis to ensure the fat content was similar for all of the starting material.Thiobarbituric acid reactive substances (TBARS) were determined on raw and cooked samples to evaluate lipid oxidation. A trained six member sensory panel evaluated the samples at each storage period for saltiness, off flavor, and oxidized odor. Break strength was conducted using a Texture Analyzer and compared with salt soluble proteins (increasing salt concentrations) to evaluate protein extractability characteristics. Statistical analyses were conducted using the MIXED procedure of SAS within repeated measures over time where appropriate. No significant differences were observed among the salt treatments for raw and cooked TBARS when the control group was removed (P>0.05). Sensory panelists detected increased levels of off flavor and oxidized odor over the entire storage duration. Less force was required to break the patties from the control group when compared with the salt treatments (P<0.05). As salt concentration increased salt-soluble protein extraction increased, but there was no effect of salt type. Overall, no meaningful statistical differences among the various salt treatments were observed for all of the parameters evaluated for turkey and pork. Salt at a 1% inclusion rate containing varying levels of copper, iron, and manganese impurities in ground turkey thigh meat and ground pork served as a prooxidant. However, if a meat processor uses a 1% inclusion rate of salt in turkey and pork regardless of impurities included, it is unlikely that differences in shelf life or protein functionality would be observed.
Resumo:
The processing of meats at the factory level can trigger the onset of lipid oxidation, which can lead to meat quality deterioration. Warmed over flavor is an off-flavor, which is associated with oxidative deterioration in meat. To avoid or delay the auto-oxidation process in meat products, synthetic and natural antioxidants have been successfully used. Grape (Vitis Vinifera) is of special interest due to its high content of phenolic compounds. Grape seed extract sold commercially as a dietary supplement, has the potential to reduce lipid oxidation and WOF in cooked ground beef when added at 1%. The objective of study 1 was to compare the antioxidant activity of natural antioxidants including grape seed extract and some herbs belonging to the Lamiaciae family: rosemary (Rosmarinus Officinalis), sage (Salvia Officinalis) and oregano (Origanum Vulgare) with commercial synthetic antioxidants like BHT, BHA, propyl gallate and ascorbic acid using the ORAC assay. All sample solutions were prepared to contain 1.8 gm sample/10 ml solvent. The highest antioxidant activity was observed for the grape seed extract sample (359.75 µM TE), while the lowest was observed for BHA, propyl gallate and rosemary also showed higher antioxidant potential with ORAC values above 300 μmol TE/g. ORAC values obtained for ascorbic acid and Sage were between 250-300μ mol TE/g while lowest values were obtained for Butylated Hydroxytoluene (28.50 µM TE). Based on the high ORAC values obtained for grape seed extract, we can conclude that byproducts of the wine/grape industry have antioxidant potential comparable to or better than those present in synthetic counterparts. The objective of study 2 was to compare three levels of grape seed extract (GSE) to commonly used antioxidants in a pre-cooked, frozen, stored beef and pork sausage model system. Antioxidants added for comparison with control included grape seed extract (100, 300, 500 ppm), ascorbic acid (AA, 100 ppm of fat) and propyl gallate (PG, 100 ppm of fat). Product was formed into rolls, frozen, sliced into patties, cooked on a flat griddle to 70C, overwrapped in PVC, and then frozen at –18C for 4 months. GSE- and PG-containing samples retained their fresh cooked beef odor and flavor longer (p<0.05) than controls during storage. Rancid odor and flavor scores of GSE-containing samples were lower (p<0.05) than those of controls after 4 months of storage. The L* value of all samples increased (p<0.05) during storage. Thiobarbituric acid reactive substances (TBARS) of the control and AA-containing samples increased (p<0.05); those of GSE-containing samples did not change significantly (p>0.05) over the storage period.
Resumo:
Doutoramento em Engenharia Agronómica - Instituto Superior de Agronomia - UL
Resumo:
To shed light on the potential efficacy of cycling as a testing modality in the treatment of intermittent claudication (IC), this study compared physiological and symptomatic responses to graded walking and cycling tests in claudicants. Sixteen subjects with peripheral arterial disease (resting ankle: brachial index (ABI) < 0.9) and IC completed a maximal graded treadmill walking (T) and cycle (C) test after three familiarization tests on each mode. During each test, symptoms, oxygen uptake (VO2), minute ventilation (VE), respiratory exchange ratio (RER) and heart rate (HR) were measured, and for 10 min after each test the brachial and ankle systolic pressures were recorded. All but one subject experienced calf pain as the primary limiting symptom during T; whereas the symptoms were more varied during C and included thigh pain, calf pain and dyspnoea. Although maximal exercise time was significantly longer on C than T (690 +/- 67 vs. 495 +/- 57 s), peak VO2, peak VE and peak heart rate during C and T were not different; whereas peak RER was higher during C. These responses during C and T were also positively correlated (P < 0.05) with each other, with the exception of RER. The postexercise systolic pressures were also not different between C and T. However, the peak decline in ankle pressures from resting values after C and T were not correlated with each other. These data demonstrate that cycling and walking induce a similar level of metabolic and cardiovascular strain, but that the primary limiting symptoms and haemodynamic response in an individual's extremity, measured after exercise, can differ substantially between these two modes.
Resumo:
The current world situation is plagued by “wicked problems” and a widespread sense of “things are going to get worse”. We confront the almost imponderable consequences of global habitat destruction and climate change, as well as the meltdown of the financial markets with their largely yet to be seen damage to the “real economy”. These things will have considerable negative impacts on the social system and people's lives, particularly the disadvantaged and socially excluded, and require innovative policy and program responses delivered by caring, intelligent, and committed practitioners. These gargantuan issues put into perspective the difficulties that confront social, welfare, and community work today. Yet, in times of trouble, social work and human services tend to do well. For example, although Australian Social Workers and Welfare and Community Workers have experienced phenomenal job growth over the past 5 years, they also have good prospects for future growth and above average salaries in the seventh and sixth deciles, respectively (Department of Education, Employment and Workplace Relations, 2008). I aim to examine the host of reasons why the pursuit of social justice and high-quality human services is difficult to attain in today's world and then consider how the broadly defined profession of social welfare practitioners may collectively take action to (a) respond in ways that reassert our role in compassionately assisting the downtrodden and (b) reclaim the capacity to be a significant body of professional expertise driving social policy and programs. For too long social work has responded to the wider factors it confronts through a combination of ignoring them, critiquing from a distance, and concentrating on the job at hand and our day-to-day responsibilities. Unfortunately, “holding the line” has proved futile and, little by little, the broad social mandate and role of social welfare has altered until, currently, most social programs entail significant social surveillance of troublesome or dangerous groups, rather than assistance. At times it almost seems like the word “help” has been lost in the political and managerial lexicon, replaced by “manage” and “control”. Our values, beliefs, and ethics are under real threat as guiding principles for social programs.
Resumo:
It is widely acknowledged that “quality of life” (QoL) is an imprecise concept, which is difficult to define (Arnold, 1991; Ball et al., 2000; Bury & Holme, 1993; Byrne & MacLean, 1997; Guse & Masesar, 1999; McDowell & Newell, 1996). McDowell and Newell (1996) described the term as “intuitively familiar” (p.382), suggesting that everyone believes that they know what it means; while, in reality its meaning differs from person to person. Recent years, have seen steadily increasing interest in the study and measurement of QoL related to human services, which reflects greater importance being attached to accountability in its widest sense. Anecdotally, many care staff will indicate that ensuring good QoL for their clients is important to them, but how can we ascertain whether we are achieving positive QoL outcomes, and given the complexities of the concept and its measurement, how can we best incorporate QoL assessment into everyday practice? This chapter will explore the issues of QoL definition and measurement, particularly as they pertain to aged care. It will consider many measurement tool options, and provide advice on how to choose an appropriate instrument for your circumstances. Issues of quality of care and their relationship to QoL will also be considered, and the chapter will conclude with a discussion on the integration of QoL assessment into practice. Because residential aged care constitutes a living environment as well as a care environment, QoL is considered particularly pertinent in this context, and as such, it will provide much of the focus for the chapter
Resumo:
Previous research into the use of explicit and implicit conclusions in advertising has yet to demonstrate consistent effects for both brand attitudes and purchase intentions. While research has examined the role of involvement, this study contributes by examining the trait called need for cognition (NFC), which addresses a person’s propensity to engage in effortful thinking. In addition, this study introduces argument quality (AQ) as another potential moderator of conclusion explicitness effects. In a 2 × 2 experiment of 261 subjects, conclusion explicitness (explicit conclusion, implicit conclusion) and AQ (strong, weak) are manipulated, with NFC (high NFC, low NFC) as a third measured variable. Results indicate more favorable evaluations for implicit conclusions over explicit conclusions for high-NFC individuals. Further, implicit conclusions result in more favorable brand attitudes and purchase intentions when linked with strong AQ for high-NFC individuals. The findings confirm that conclusion explicitness does not differentially affect the evaluations of low-NFC subjects. Results suggest that NFC may represent an important moderating variable for future conclusion explicitness research.
Resumo:
Background: While the relationship between socioeconomic disadvantage and cardiovascular disease (CVD) is well established, the role that traditional cardiovascular risk factors play in this association remains unclear. We examined the association between education attainment and CVD mortality and the extent to which behavioural, social and physiological factors explained this relationship. Methods: Adults (n=38 355) aged 40-69 years living in Melbourne, Australia were recruited in 1990-1994. Subjects with baseline CVD risk factor data ascertained through questionnaire and physical measurement were followed for an average of 9.4 years with CVD deaths verified by review of medical records and autopsy reports. Results: CVD mortality was higher for those with primary education only compared to those who had completed tertiary education, with a hazard ratio (HR) of 1.66 (95% confidence interval [CI] 1.11-2.49) after adjustment for age, country of birth and gender. Those from the lowest educated group had a more adverse cardiovascular risk factor profile compared to the highest educated group, and adjustment for these risk factors reduced the HR to 1.18 (95% CI 0.78-1.77). In analysis of individual risk factors, smoking and waist circumference explained most of the difference in CVD mortality between the highest and lowest education groups. Conclusions: Most of the excess CVD mortality in lower socioeconomic groups can be explained by known risk factors, particularly smoking and overweight. While targeting cardiovascular risk factors should not divert efforts from addressing the underlying determinants of health inequalities, it is essential that known risk factors are addressed effectively among lower socioeconomic groups.
Resumo:
This paper describes control methods for proper load sharing between parallel converters connected in a microgrid and supplied by distributed generators (DGs). It is assumed that the microgrid spans a large area and it supplies loads in both in grid connected and islanded modes. A control strategy is proposed to improve power quality and proper load sharing in both islanded and grid connected modes. It is assumed that each of the DGs has a local load connected to it which can be unbalanced and/or nonlinear. The DGs compensate the effects of unbalance and nonlinearity of the local loads. Common loads are also connected to the microgrid, which are supplied by the utility grid under normal conditions. However during islanding, each of the DGs supplies its local load and shares the common load through droop characteristics. Both impedance and motor loads are considered to verify the system response. The efficacy of the controller has been validated through simulation for various operating conditions using PSCAD. It has been found through simulation that the total Harmonic Distortion (THD) of the of the microgrid voltage is about 10% and the negative and zero sequence component are around 20% of the positive sequence component before compensation. After compensation, the THD remain below 0.5%, whereas, negative and zero sequence components of the voltages remain below 0.02% of the positive sequence component.
Resumo:
The Queensland University of Technology (QUT) allows the presentation of theses for the Degree of Doctor of Philosophy in the format of published or submitted papers, where such papers have been published, accepted or submitted during the period of candidature. This thesis is composed of ten published /submitted papers and book chapters of which nine have been published and one is under review. This project is financially supported by an Australian Research Council (ARC) Discovery Grant with the aim of investigating multilevel topologies for high quality and high power applications, with specific emphasis on renewable energy systems. The rapid evolution of renewable energy within the last several years has resulted in the design of efficient power converters suitable for medium and high-power applications such as wind turbine and photovoltaic (PV) systems. Today, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements controlled by powerful processor systems. However, it is hard to connect the traditional converters to the high and medium voltage grids, as a single power switch cannot stand at high voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Besides this important feature, multilevel converters have the capability to generate stepped waveforms. Consequently, in comparison with conventional two-level inverters, they present lower switching losses, lower voltage stress across loads, lower electromagnetic interference (EMI) and higher quality output waveforms. These properties enable the connection of renewable energy sources directly to the grid without using expensive, bulky, heavy line transformers. Additionally, they minimize the size of the passive filter and increase the durability of electrical devices. However, multilevel converters have only been utilised in very particular applications, mainly due to the structural limitations, high cost and complexity of the multilevel converter system and control. New developments in the fields of power semiconductor switches and processors will favor the multilevel converters for many other fields of application. The main application for the multilevel converter presented in this work is the front-end power converter in renewable energy systems. Diode-clamped and cascade converters are the most common type of multilevel converters widely used in different renewable energy system applications. However, some drawbacks – such as capacitor voltage imbalance, number of components, and complexity of the control system – still exist, and these are investigated in the framework of this thesis. Various simulations using software simulation tools are undertaken and are used to study different cases. The feasibility of the developments is underlined with a series of experimental results. This thesis is divided into two main sections. The first section focuses on solving the capacitor voltage imbalance for a wide range of applications, and on decreasing the complexity of the control strategy on the inverter side. The idea of using sharing switches at the output structure of the DC-DC front-end converters is proposed to balance the series DC link capacitors. A new family of multioutput DC-DC converters is proposed for renewable energy systems connected to the DC link voltage of diode-clamped converters. The main objective of this type of converter is the sharing of the total output voltage into several series voltage levels using sharing switches. This solves the problems associated with capacitor voltage imbalance in diode-clamped multilevel converters. These converters adjust the variable and unregulated DC voltage generated by renewable energy systems (such as PV) to the desirable series multiple voltage levels at the inverter DC side. A multi-output boost (MOB) converter, with one inductor and series output voltage, is presented. This converter is suitable for renewable energy systems based on diode-clamped converters because it boosts the low output voltage and provides the series capacitor at the output side. A simple control strategy using cross voltage control with internal current loop is presented to obtain the desired voltage levels at the output voltage. The proposed topology and control strategy are validated by simulation and hardware results. Using the idea of voltage sharing switches, the circuit structure of different topologies of multi-output DC-DC converters – or multi-output voltage sharing (MOVS) converters – have been proposed. In order to verify the feasibility of this topology and its application, steady state and dynamic analyses have been carried out. Simulation and experiments using the proposed control strategy have verified the mathematical analysis. The second part of this thesis addresses the second problem of multilevel converters: the need to improve their quality with minimum cost and complexity. This is related to utilising asymmetrical multilevel topologies instead of conventional multilevel converters; this can increase the quality of output waveforms with a minimum number of components. It also allows for a reduction in the cost and complexity of systems while maintaining the same output quality, or for an increase in the quality while maintaining the same cost and complexity. Therefore, the asymmetrical configuration for two common types of multilevel converters – diode-clamped and cascade converters – is investigated. Also, as well as addressing the maximisation of the output voltage resolution, some technical issues – such as adjacent switching vectors – should be taken into account in asymmetrical multilevel configurations to keep the total harmonic distortion (THD) and switching losses to a minimum. Thus, the asymmetrical diode-clamped converter is proposed. An appropriate asymmetrical DC link arrangement is presented for four-level diode-clamped converters by keeping adjacent switching vectors. In this way, five-level inverter performance is achieved for the same level of complexity of the four-level inverter. Dealing with the capacitor voltage imbalance problem in asymmetrical diodeclamped converters has inspired the proposal for two different DC-DC topologies with a suitable control strategy. A Triple-Output Boost (TOB) converter and a Boost 3-Output Voltage Sharing (Boost-3OVS) converter connected to the four-level diode-clamped converter are proposed to arrange the proposed asymmetrical DC link for the high modulation indices and unity power factor. Cascade converters have shown their abilities and strengths in medium and high power applications. Using asymmetrical H-bridge inverters, more voltage levels can be generated in output voltage with the same number of components as the symmetrical converters. The concept of cascading multilevel H-bridge cells is used to propose a fifteen-level cascade inverter using a four-level H-bridge symmetrical diode-clamped converter, cascaded with classical two-level Hbridge inverters. A DC voltage ratio of cells is presented to obtain maximum voltage levels on output voltage, with adjacent switching vectors between all possible voltage levels; this can minimize the switching losses. This structure can save five isolated DC sources and twelve switches in comparison to conventional cascade converters with series two-level H bridge inverters. To increase the quality in presented hybrid topology with minimum number of components, a new cascade inverter is verified by cascading an asymmetrical four-level H-bridge diode-clamped inverter. An inverter with nineteen-level performance was achieved. This synthesizes more voltage levels with lower voltage and current THD, rather than using a symmetrical diode-clamped inverter with the same configuration and equivalent number of power components. Two different predictive current control methods for the switching states selection are proposed to minimise either losses or THD of voltage in hybrid converters. High voltage spikes at switching time in experimental results and investigation of a diode-clamped inverter structure raised another problem associated with high-level high voltage multilevel converters. Power switching components with fast switching, combined with hard switched-converters, produce high di/dt during turn off time. Thus, stray inductance of interconnections becomes an important issue and raises overvoltage and EMI issues correlated to the number of components. Planar busbar is a good candidate to reduce interconnection inductance in high power inverters compared with cables. The effect of different transient current loops on busbar physical structure of the high-voltage highlevel diode-clamped converters is highlighted. Design considerations of proper planar busbar are also presented to optimise the overall design of diode-clamped converters.
Resumo:
Managing service quality is of primary importance for organizations that are increasingly service oriented, and offering a growing range of services to external and internal customers. Managing service quality requires the capacity to measure service quality, concomitantly requiring explicit conceptions of ‘service’ and ‘service quality’. This white-paper explores three keys areas of service and service marketing literature: service definition and conceptualisation, service classifications, and service quality models, and make the following observations and proposals.