215 resultados para Pacing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. METHODS AND RESULTS We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P < 0.001). Finally, a batteryless single-chamber pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. CONCLUSION Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Mapping to identify scar-related ventricular tachycardia re-entry circuits during sinus rhythm focuses on sites with abnormal electrograms or pace-mapping findings of QRS morphology and long stimulus to QRS intervals. We hypothesized that (1) these methods do not necessarily identify the same sites and (2) some electrograms are far-field potentials that can be recognized by pacing. METHODS AND RESULTS From 12 patients with coronary disease and recurrent ventricular tachycardia undergoing catheter ablation, we retrospectively analyzed electrograms and pacing at 546 separate low bipolar voltage (<1.5 mV) sites. Electrograms were characterized as showing evidence of slow conduction if late potentials (56%) or fractionated potentials (76%) were present. Neither was present at (13%) sites. Pacing from the ablation catheter captured 70% of all electrograms. Higher bipolar voltage and fractionation were independent predictors for pace capture. There was a linear correlation between the stimulus to QRS duration during pacing and the lateness of a capturing electrogram (P<0.001), but electrogram and pacing markers of slow conduction were discordant at 40% of sites. Sites with far-field potentials, defined as those that remained visible and not captured by pacing stimuli, were identified at 48% of all pacing sites, especially in areas of low bipolar voltage and late potentials. Initial radiofrequency energy application rendered 74% of targeted sites electrically unexcitable. CONCLUSIONS Far-field potentials are common in scar areas. Combining analysis of electrogram characteristics and assessment of pace capture may refine identification of substrate targets for radiofrequency ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Publication suspended 1924-1926.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biventdcular (BV) pacing is evaluated as an alternative treatment for patients with dilated cardiomyppathy (both ischemic and non-ischemic) and end-stage heart failure. Colour tissue Doppler imaging using echocardiography allows noninvasive, quantitative assessment of radial motion in the long-axis with measurement of peak systolic velocity timing. The aim of the present study was to evaluate quantitatively, the systolic performance of the left ventricle and the resynchrenization of contraction (before vs after implantation). Patients and methods: 25 patients with dilated cardiomyopathy (11 ischemic), NYHA class III or IV, QRS duration >120 ms received a biventricular pacemaker. Routine 2D echo and colour tissue Doppler imaging were performed before and within 1 week following implantation. LVEF was assessed using the biplane Sampson's method.Peak systolic velocity (PSV) and time to PSV (TPV) were assessed in 4 regions (basal anterior, inferior, lateral and septal). By averaging the TPV from all 4 regions, a synchronization index was dedved from these measurements. Reaults: LVEF improved by 9±9% following pacing; 17 patients improved LVEF 5% or more. The change in PSV in the septal and lateral regions related significantly to the change in LVEF (r=0.74, r=0.62).The change in synchronization index before vs after pacing (as a measurement of REsynchronization) was related to the change in LVEF (y=120x+5.6, r=0.79, P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensorimotor synchronization is hypothesized to arise through two different processes, associated with continuous or discontinuous rhythmic movements. This study investigated synchronization of continuous and discontinuous movements to different pacing signals (auditory or visual), pacing interval (500, 650, 800, 950 ms) and across effectors (non-dominant vs. non-dominant hand). The results showed that mean and variability of asynchronization errors were consistently smaller for discontinuous movements compared to continuous movements. Furthermore, both movement types were timed more accurately with auditory pacing compared to visual pacing and were more accurate with the dominant hand. Shortening the pacing interval also improved sensorimotor synchronization accuracy in both continuous and discontinuous movements. These results show the dependency of temporal control of movements on the nature of the motor task, the type and rate of extrinsic sensory information as well as the efficiency of the motor actuators for sensory integration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motor timing tasks have been employed in studies of neurodevelopmental disorders such as developmental dyslexia and ADHD, where they provide an index of temporal processing ability. Investigations of these disorders have used different stimulus parameters within the motor timing tasks which are likely to affect performance measures. Here we assessed the effect of auditory and visual pacing stimuli on synchronised motor timing performance and its relationship with cognitive and behavioural predictors that are commonly used in the diagnosis of these highly prevalent developmental disorders. Twenty- one children (mean age 9.6 years) completed a finger tapping task in two stimulus conditions, together with additional psychometric measures. As anticipated, synchronisation to the beat (ISI 329 ms) was less accurate in the visually paced condition. Decomposition of timing variance indicated that this effect resulted from differences in the way that visual and auditory paced tasks are processed by central timekeeping and associated peripheral implementation systems. The ability to utilise an efficient processing strategy on the visual task correlated with both reading and sustained attention skills. Dissociations between these patterns of relationship across task modality suggest that not all timing tasks are equivalent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A segurança do doente revela-se como uma das questões mais importantes ao nível da política de saúde e do debate público (OCDE, 2014). A Comissão Europeia refere que, não existindo qualquer alteração de política de saúde, o número de eventos adversos associados à hospitalização, na União Europeia, rondaria os dez milhões por ano, dos quais cerca de 4,4 milhões seriam evitáveis. Tendo em conta os dados acima apresentados de que forma nós, na nossa prática de cuidados podemos contribuir para a segurança do doente, nomeadamente, em doentes submetidos a estudos electrofisiológicos e implantação de dispositivos cardíaco (PMD / CDI). Nesta prelecção iremos abordar o percurso do doente, desde que este é informado da necessidade de implantação de um dispositivo cardíaco, em consulta médica, até ao seu seguimento no pós-alta, em consulta de enfermagem. Deste modo, podemos constatar que a nossa prática diária de cuidados vai de encontro às recomendações do Conselho Europeu (2009) para a segurança do doente. Os serviços de saúde devem ser orientados para o doente, ou seja, comunicar e interagir com os doentes num ambiente humanizado, de forma a minimizar o desconforto associado à situação que os leva a recorrer aos serviços de saúde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary embolism (PE) related to the presence of right heart thromboemboli entails a higher mortality rate than PE alone. Furthermore, right heart thromboemboli are often associated with deep venous thrombosis. The most effective therapy for haemodynamically stable patients remains unknown, although recent data suggest that thrombolytic therapy is associated with a better outcome. We describe the case of an 83-year-old woman, hospitalized with PE consequent to right heart thrombus-in-transit, in whom investigation revealed a concomitant deep venous thrombosis. She required thrombolysis, given the high mortality risk that is traditionally associated with this clinical entity.