122 resultados para PFM


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of intravaginal electrical stimulation (IES) on pelvic floor muscle (PFM) strength in patients with mixed urinary incontinence (MUI). Between January 2001 and February 2002, 40 MUI women (mean age: 48 years) were studied. Urge incontinence was the predominant symptom; 92.5% also presented mild stress urinary incontinence (SUI). Selection criteria were clinical history and urodynamics. Pre-treatment urodynamic study showed no statistical differences between the groups. Ten percent of the women in each group had involuntary detrusor contractions. Patients were randomly distributed, in a double-blind study, into two groups. Group G 1 (n=20), effective IES, and group G2 (n=20), sham IES, with follow-up at 1 month. The following parameters were studied: (1) clinical questionnaire, (2) examiner's evaluation of perineal muscle strength, (3) objective evaluation of perineal muscle by perineometry, (4) vaginal weight test, and (5) urodynamic study. The IES protocol consisted of three 20-min sessions per week over a 7-week period using a Dualpex Uro 996 at 4 Hz. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence, present in all patients before treatment, was reduced to 15% in G1 and 31.5% in G2 post-treatment. The subjective evaluation of PFM strength demonstrated a significant improvement in G1. Objective evaluation of PFM force by perineometer showed a significant improvement in maximum peak contraction post-treatment in both groups. In the vaginal weight test, there was a significant increase in average number of cone retentions post-treatment in both groups. With regard to satisfaction level, after treatment, 80% of the patients in G1 and 65% of the patients in G2 were satisfied. There was no statistically significant difference between the groups. There was a significant improvement in PFM strength from both effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy in treating MUI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess pelvic floor muscle (PFM) strength and perception and its correlation with stress urinary incontinence (SUI). One hundred and one women were divided into two groups according to the presence (G1=51 patients) or absence (G2=50 patients) of SUI. Subjective [urine stream interruption test (UST), visual survey of perineal contraction and transvaginal digital palpation to assess pelvic muscle contraction] and objective evaluations of pelvic floor muscles in all patients were performed (vaginal manometry). During the UST, 25.5% of G1 patients and 80% of G2 patients were able to interrupt the urine stream (p<0.05). Digital evaluation of pelvic muscular contraction showed higher strength in G2 than in G1 patients (p<0.0001). Perineometer evaluation of PFM strength was significantly higher in the continent group (p<0.001). Pelvic floor muscle weakness in incontinent patients demonstrates the importance of functional and objective evaluation of this group of muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To assess pelvic floor muscle (PFM) strength in women with stress urinary incontinence (SUI) and urge urinary incontinence (UUI).Materials and Methods: 51 women were prospectively divided into two groups, according to the symptoms as SUI (G1 = 22) or UUI (G2 = 29). Demographic data, such as number of pads/ 24 hours, number of micturations/ 24 hours and nocturia, delay time of urgent void (i.e., the time period for which an urgent void could be voluntarily postponed), number of parity and vaginal deliveries were obtained using a clinical questionnaire. Objective urine loss was evaluated by 60-min. Pad Test, subjective urine stream interruption test (UST) and visual survey of perineal contraction. Objective evaluations of PFM were performed in all patients (vaginal manometry).Results: Median of age, mean number of pads/ 24 hours, nocturia and warning time were significantly higher in UUI comparing to SUI group. During UST, 45.45% in G1 and 3.44%, in G2, were able to interrupt the urine stream (p < 0.001). The 60-min. Pad Test was significantly higher in G2 compared to G1 women (2.7 +/- 2.4 vs 1.5 +/- 1.9 respectively, p = 0.049). Objective evaluation of PFM strength was significantly higher in the SUI than in the UUI patients. No statistical difference was observed regarding other studied parameters.Conclusion: Pelvic floor muscle weakness was significantly higher in women with UUI when compared to SUI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vaginal weight cone (VWC) versus assisted pelvic floor muscle training (APFMT) in the treatment of urinary incontinence (UI) in women.One hundred three incontinent women were randomly distributed into two groups: group G1 (n = 51) treated with VWC and G2 (n = 52), APFMT. The following parameters were performed initially and after treatment: (1) clinical questionnaire, (2) visual analogue scale (VAS), (3) 60-min pad test, and (4) subjective and objective assessment of pelvic floor muscle (PFM).There was a significant decrease in nocturia and urine loss after treatment in both groups (p < 0.05). In VAS, there was a significant improvement of all parameters in both groups (p < 0.05). The pad test showed significant decrease in both groups (p < 0.05). There was a significant increase of PFM strength in both groups (p < 0.05).There was no difference between groups treated with VWC and APFMT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Consistent information on meat products consumed by the public is essential. The technique of stable isotopes is a powerful tool to recover consumers' confidence, as it allows the detection of animal byproduct residues in poultry meat, particularly in quail meat. This study aimed at checking the presence of poultry byproduct mixtures in quail diets by applying the technique of carbon (13C/12C) and nitrogen (15N/14N) stable isotopes in quail breast muscle, keel, and tibia. Sixty four one-day-old male quails were obtained from a commercial farm. Birds were housed in an experimental house from one to 42 days of age, and were randomly distributed into 8 experimental treatments, and fed diets containing poultry offal meal (POM), bovine meat and bone meal (MBM) or poultry feather meal (PFM), or their mixtures. Four birds per treatment were slaughtered at 42 days of age, and breast (Pectoralis major), keel, and tibia were collected for analyses. The inclusion of animal byproducts in quail diets was detected by 13C e 15N analyses in the tissues of the birds; however, it was not possible to specify which byproducts were used. It was concluded that quail meat can be certified by the technique of stable isotopes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Piezoresponse Force Microscopy (PFM) is used to characterize the nanoscale electromechanical properties of centrosymmetric CaCu3Ti4O12 ceramics with giant dielectric constant. Clear PFM contrast both in vertical (out-of-plane) and lateral (in-plane) modes is observed on the ceramic surface with varying magnitude and polarization direction depending on the grain crystalline orientation. Lateral signal changes its sign upon 180 degrees rotation of the sample thus ruling out spurious electrostatic contribution and confirming piezoelectric nature of the effect. Piezoresponse could be locally reversed by suitable electrical bias (local poling) and induced polarization was quite stable showing long-time relaxation (similar to 3 hrs). The electromechanical contrast in unpoled ceramics is attributed to the surface flexoelectric effect (strain gradient induced polarization) while piezoresponse hysteresis and ferroelectric-like behavior are discussed in terms of structural instabilities due to Ti off-center displacements and structural defects in this material. (C) 2011 American Institute of Physics. [doi:10.1063/1.3623767]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: o avanço maxilomandibular é um método cirúrgico comumente usado no tratamento de pacientes acometidos pela Síndrome da Apnéia Obstrutiva do Sono (SAOS) e portadores de anormalidades anatômicas identificáveis neste complexo, que estreitam e/ou obstruem o espaço aéreo. O intuito deste estudo foi analisar variações cefalométricas do espaço aéreo faríngeo em indivíduos Classe II de Angle, após a cirurgia ortognática. METODOLOGIA: a amostra consistiu de telerradiografias laterais equivalentes aos períodos pré e pós-operatório de 30 indivíduos, divididos no grupo com avanço cirúrgico mandibular (n=15) e no grupo com avanço maxilomandibular (n=15). Os parâmetros cefalométricos usados permitiram avaliar o espaço aéreo posterior em 3 níveis: a hipofaringe (PFI-V), a orofaringe (PFM-PM, PFM-PO, PFM-U, PFM-Up) e a nasofaringe (PFM-PN, pm-PFS). A análise esquelética foi na base do crânio (N-S-Ba) e na mandíbula (Ar-Go-Me). A média das diferenças entre os valores pré e pós-operatórios das mensurações lineares (mm) e angulares (graus) foi avaliada pelo teste t pareado. RESULTADOS E CONCLUSÕES: estatisticamente, não houve redução do espaço aéreo faríngeo pós-avanço cirúrgico. O que se observou foi que apenas PFM-PO e PFS-pM se mantiveram constantes e na maioria restante os valores aumentaram.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bismuth titanate (Bi4Ti3O12, BIT) films were evaluated for use as lead-free piezoelectric thin films in micro-electromechanical systems. The films were grown by the polymeric precursor method on LaNiO3/SiO2/Si (1 0 0) (LNO), RuO2/SiO2/Si (1 0 0) (RuO2) and Pt/Ti/SiO2/Si (1 0 0) (Pt) bottom electrodes in a microwave furnace at 700 degrees C for 10 min. The domain structure was investigated by piezoresponse force microscopy (PFM). Although the converse piezoelectric coefficient, d(33), regardless of bottom electrode is around (similar to 40 pm/V), those over RuO2 and LNO exhibit better ferroelectric properties, higher remanent polarization (15 and 10 mu C/cm(2)), lower drive voltages (2.6 and 1.3 V) and are fatigue-free. The experimental results demonstrated that the combination of the polymeric precursor method assisted with a microwave furnace is a promising technique to obtain films with good qualities for applications in ferroelectric and piezoelectric devices. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bismuth titanate (Bi4Ti3O12-BIT) films were evaluated for use as lead-free piezoelectric thin-films in micro-electromechanical systems. The films were grown by the polymeric precursor method on Pt/Ti/SiO2/Si (1 0 0) (Pt) bottom electrodes at 700 degrees C for 2 h in static air and oxygen atmospheres. The domain structure was investigated by piezoresponse force microscopy (PFM). Annealing in static air leads to better ferroelectric properties, higher remanent polarization, lower drive voltages and higher piezoelectric coefficient. on the other hand, oxygen atmosphere favors the imprint phenomenon and reduces the piezoelectric coefficient dramatically. Impedance data, represented by means of Nyquist diagrams, show a dramatic increase in the resistivity for the films annealed in static air atmopshere. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bi 4Ti 3- xNbxO 12 (BITNb) samples, with × ranging from 0 to 0.40 were obtained using a polymeric precursor solution. Rietveld analyses confirmed that the powders crystallize in an orthorhombic structure free of secondary phases with space group Fmmm. Raman analysis evidenced a sharp increase in the bands intensity located at 129 cm -1 and 190 cm -1 due the lattice distortion in BIT02Nb and BIT04Nb compositions. UV-vis spectra indicated that addition of niobium causes a reduction of defects in the BIT lattice due the suppression of oxygen vacancies located at BO-6 octahedral. Size and morphology of particles as well as electrical behavior of BIT ceramics were affected by addition of donor dopant. Polarization reversal was investigated by applying dc voltage through a conductive tip during the area scanning and was investigated by piezoresponse force microscopy (PFM). PFM measurements revealed a decrease in piezoelectric response with increasing Nb concentration originating from a reduced polarizability along the a-axis. High spontaneous polarization is noted for the less doped sample due the reduction of strain energy and pin charged defects after niobium addition. Copyright © 2010 American Scientific Publishers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lead zirconate titanate Pb(Zr 0.50Ti 0.50)O 3 (PZT) thin films were deposited by a polymeric chemical method on Pt(111)/Ti/SiO2/Si substrates to understand the mechanisms of phase transformations and the effect of film thickness on the structure, dielectric and piezoelectric properties in these films. PZT films pyrolyzed at temperatures higher than 350 °C present a coexistence of pyrochlore and perovskite phases, while only perovskite phase grows in films pyrolyzed at temperatures lower than 300 °C. For pyrochlore-free PZT thin films, a small (100) orientation tendency near the film-substrate interface was observed. Finally, we demonstrate the existence of a self-polarization effect in the studied PZT thin films. Results suggest that Schottky barriers and/or mechanical coupling near the filmsubstrate interface are not primarily responsible for the observed self-polarization effect in our films. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)