853 resultados para Multilevel multitrait multimethod
Resumo:
This multidisciplinary research advanced the current understanding of self-regulation – a critical component in safe and sustainable mobility for older adults. It investigates the sociodemographic and psychosocial factors that underlies older adults' self-regulation, and examines their travel behaviours using a combination of self-report, in-vehicle and wearable devices. This research developed a novel theoretical model that significantly predicts self-regulation and objectively driving behaviours among older drivers.
Resumo:
Background Poor mental health is a significant cause of morbidity and mortality, yet debate continues about factors most likely to predict poor mental health outcomes. Objective This cohort study examines the influence of modifiable lifestyle factors, menopausal symptoms, and physical health on the mental health of midlife and older Australian women. Methods: Random sampling was used to recruit women aged 40-55, from rural and urban areas of Queensland, Australia. Overall, 340 women completed mailed surveys on socio-demographic characteristics, midlife symptoms (Greene Climacteric Scale©), modifiable lifestyle factors, and mental health (SF-12©) in 2001, 2004 and 2011. Hierarchical repeated-measure models were used to explore the correlates of poor mental health over time. Results The mean age [SD] at baseline was 55 [2.7] years, most were married (73%, n=248) and 18% were pre-menopausal. The model suggested that variance in mental health widened and showed a non-linear increase with age. Decrements in mental health were associated with an increase in midlife symptoms (Greene psychological scale, P <0.01; Greene somatic scale, P <0.05), time (P <0.01), poor physical health (P <0.01) and individual variance (P <0.01). Socio-demographics and lifestyle factors had little influence on mental health over time. Conclusion Findings suggest that while women’s mental health may decline during midlife, the effect is temporary; in older women, physical health and individual factors seem to be increasingly significant. This research highlights the importance of active health promotion as a means of enhancing both physical and mental health in midlife women.
Resumo:
The authors conducted a theoretical review of the change readiness literature and identified two major limitations with this work. First, while there is substantial agreement about the key cognitions that underlie change readiness, researchers have not examined the affective element of this attitude. Second, researchers have not adopted a multilevel perspective when considering change readiness. The authors address these limitations and argue that it is important to incorporate affect into definitions of the change readiness construct and also when measuring this construct. They then develop a multilevel framework that identifies the antecedents and consequences of individual, work group, and organizational change readiness. Next, the authors outline the theoretical processes that lead to the development of individual and collective change readiness. They then review theoretical and empirical evidence to identify the antecedents of change readiness at the three levels of analysis. Finally, the authors identify a number of suggestions to guide future research seeking to adopt a multilevel approach to change readiness.
Resumo:
Modulation and control of a cascade multilevel static synchronous compensator (STATCOM) configuration to improve the quality of voltage generated by wind power systems are presented. The proposed STATCOM configuration needs only four dc-link capacitors and 24 switches to synthesise nine-level operation. In addition to that, switching losses are further reduced by splitting the voltage source inverter of the STATCOM into two units called the `bulk inverter` and the `conditioning inverter`. The high-power bulk inverter is operated at low frequency whereas the low-power conditioning inverter is operated at high frequency to suppress harmonics produced by the bulk inverter. Fluctuations at the point of common coupling voltage, caused by sudden wind changes, are suppressed by controlling reactive power of the STATCOM. Simulation and experimental results are presented to verify the efficacy of the proposed modulation and control techniques used in the STATCOM.
Resumo:
The possibility to control the electric resistivity-temperature dependence of the nanosized resistive components made using hierarchical multilevel arrays of self-assembled gold nanoparticles prepared by multiple deposition/annealing is demonstrated. It is experimentally shown that the hierarchical three-level patterns, where the nanoparticles of sizes ranging from several nanometers to several tens of nanometer play a competitive roles in the electric conductivity, demonstrate sharp changes in the activation energy. These patterns can be used for the precise tuning of the resistivity-temperature behavior of nanoelectronic components.
Resumo:
Purpose This study seeks to extend the existing literature on value creation by specifically focusing on service brand value creation (SBVC) and the role of brand marketing. Design/methodology/approach The authors first develop a model of SBVC and simultaneously investigate SBVC from the firm perspective (service brand value offering – SBVO) and from the customer perspective (service brand perceive value-in use – SBPVI). Subsequently, they investigate the effects of SBVO on SBPVI and integrate the moderation role of service brand marketing capability (SBMC) on the relationship between SBVO-SBPVI outcomes. SBVO is viewed as the firms' interpretation of and responsiveness to customer requirements via the delivery of superior performance the value offering through the service brand and SBPVI customers' perceived value from the firms' service brand. The contributions of SBVC to customer-based performance outcomes are then investigated. Hypotheses were tested using a sample of the senior managers of service firms in Cambodia and their customers. A survey was used to gather data via a drop-and-collect approach. Findings Results indicated that SBVO is positively related to SBPVI and SBPVI is positively related to customer-based performance. Noticeably, the results revealed that SBMC enhances the positive relationship between the firm SBVO and the customers SBPVI. Originality/value The paper extends the previous literature on value creation to capture SBVC. More significantly, the premise of the theoretical framework provides a breakthrough in the current SBVC literature which has so far neglected to take into account the dyadic approach (firm-customer) in understanding value creation and more specifically SBVC. The model is expanded by looking at the contingency role of SBMC in communicating value to customers.
Resumo:
The value of information technology (IT) is often realized when continuously being used after users’ initial acceptance. However, previous research on continuing IT usage is limited for dismissing the importance of mental goals in directing users’ behaviors and for inadequately accommodating the group context of users. This in-progress paper offers a synthesis of several literature to conceptualize continuing IT usage as multilevel constructs and to view IT usage behavior as directed and energized by a set of mental goals. Drawing from the self-regulation theory in the social psychology, this paper proposes a process model, positioning continuing IT usage as multiple-goal pursuit. An agent-based modeling approach is suggested to further explore causal and analytical implications of the proposed process model.
Resumo:
A new small full bridge module for MMCC research is presented. Each full bridge converter cell is a single small (65 × 30 mm) multilayer PCB with two low voltage high current (22 V, 40 A) integrated half bridge ICs and the necessary isolated control signals and auxiliary power supply (2500 V isolation). All devices are surface mount, minimising cell height (4 mm) and parasitic inductance. Each converter cell can be physically stacked with PCB connectors propagating the control signals and inter-cell power connections. Many cells can be trivially stacked to create a large multilevel converter leg with isolated auxiliary power and control signals. Any of the MMCC family members is then easily formed. With a change in placement of stacking connector, a parallel connection of bridges is also possible. Operation of a nine level parallel full bridge is demonstrated at 12 V and 384 kHz switching frequency delivering a 30 W 2 kHz sinewave into a resistive load. A number of new applications for this novel module aside from MMCC development are listed.
Resumo:
This paper presents a grid-side inverter based supercapacitor direct integration scheme for wind power systems. The inverter used in this study consists of a conventional two-level inverter and three H-bridge modules. Three supercapacitor banks are directly connected to the dc-links of H-bridge modules. This approach eliminates the need for interfacing dc-dc converters and thus considerably improves the overall efficiency. However, for the maximum utilization of super capacitors their voltages should be allowed to vary. As a result of this variable voltage space vectors of the hybrid inverter get distributed unevenly. To handle this issue, a modified PWM method and a space vector modulation method are proposed and they can generate undistorted current even in the presence of unevenly distributed space vectors. A supercapacitor voltage balancing method is also presented in this paper. Simulation results are presented to validate the efficacy of the proposed scheme, modulation methods and control techniques.
Resumo:
A typical low power IPT system employs an H-Bridge converter with a simple control strategy to generate a high frequency current from DC power supply. This paper proposes a cascaded multilevel converter for bidirectional IPT (BIPT) systems, which is suitable for low to medium power applications as well as for situations such as PV cells where several individual DC sources are to be utilized. A novel modulation strategy is proposed for the multilevel converter with the aim of minimizing switching losses. Series - Series (SS) compensation circuit is adopted for the IPT system and a mathematical model is presented to minimize the coil losses of the system under varying output power. Theoretical results presented in comparison to the simulations to demonstrate the applicability of the proposed concept and the validity of the developed model. The experimental results show the feasibility of the proposed phase shift modulation.
Resumo:
The capability of storing multi-bit information is one of the most important challenges in memory technologies. An ambipolar polymer which intrinsically has the ability to transport electrons and holes as a semiconducting layer provides an opportunity for the charge trapping layer to trap both electrons and holes efficiently. Here, we achieved large memory window and distinct multilevel data storage by utilizing the phenomena of ambipolar charge trapping mechanism. As fabricated flexible memory devices display five well-defined data levels with good endurance and retention properties showing potential application in printed electronics.
Resumo:
This paper presents a novel dc-link voltage regulation technique for a hybrid inverter system formed by cascading two 3-level inverters. The two inverters are named as “bulk inverter” and “conditioning inverter”. For the hybrid system to act as a nine level inverter, conditioning inverter dc link voltage should be maintained at one third of the bulk inverter dc link voltage. Since the conditioning inverter is energized by two series connected capacitors, dc-link voltage regulation should be carried out by controlling the capacitor charging/discharging times. A detailed analysis of conditioning inverter capacitor charging/discharging process and a simplified general rule, derived from the analysis, are presented in this paper. Time domain simulations were carried out to demonstrate efficacy of the proposed method on regulating the conditioning inverter dc-link voltage under various operating conditions.
Resumo:
This paper presents a novel STATCOM configuration for voltage quality improvement in wind power generation systems. The proposed STATCOM is formed by cascading two 3-level inverters, `bulk inverter' and `conditioning inverter', through a coupling transformer. Both inverters are powered by dc-link capacitors and they are charged by a small amount of active power drawn from the grid. To minimize switching losses, the high power bulk inverter operates at low frequency while low power high frequency conditioning inverter is used to suppress harmonic content produced by the bulk inverter output. With only 24 switches this topology can synthesize a nine level inverter, if the dc-link voltage ratio is maintained at 3:1. Modulation and control techniques have been developed to meet this requirement. Reactive power of the STATCOM is controlled to mitigate voltage sags or swells caused by sudden wind changes. Simulation and experimental results are presented to verify the efficacy of the proposed modulation and control techniques used in the STATCOM.
Resumo:
Introduction Risk factor analyses for nosocomial infections (NIs) are complex. First, due to competing events for NI, the association between risk factors of NI as measured using hazard rates may not coincide with the association using cumulative probability (risk). Second, patients from the same intensive care unit (ICU) who share the same environmental exposure are likely to be more similar with regard to risk factors predisposing to a NI than patients from different ICUs. We aimed to develop an analytical approach to account for both features and to use it to evaluate associations between patient- and ICU-level characteristics with both rates of NI and competing risks and with the cumulative probability of infection. Methods We considered a multicenter database of 159 intensive care units containing 109,216 admissions (813,739 admission-days) from the Spanish HELICS-ENVIN ICU network. We analyzed the data using two models: an etiologic model (rate based) and a predictive model (risk based). In both models, random effects (shared frailties) were introduced to assess heterogeneity. Death and discharge without NI are treated as competing events for NI. Results There was a large heterogeneity across ICUs in NI hazard rates, which remained after accounting for multilevel risk factors, meaning that there are remaining unobserved ICU-specific factors that influence NI occurrence. Heterogeneity across ICUs in terms of cumulative probability of NI was even more pronounced. Several risk factors had markedly different associations in the rate-based and risk-based models. For some, the associations differed in magnitude. For example, high Acute Physiology and Chronic Health Evaluation II (APACHE II) scores were associated with modest increases in the rate of nosocomial bacteremia, but large increases in the risk. Others differed in sign, for example respiratory vs cardiovascular diagnostic categories were associated with a reduced rate of nosocomial bacteremia, but an increased risk. Conclusions A combination of competing risks and multilevel models is required to understand direct and indirect risk factors for NI and distinguish patient-level from ICU-level factors.
Resumo:
This paper examines the feasibility of using vertical light pipes to naturally illuminate the central core of a multilevel building not reached by window light. The challenges addressed were finding a method to extract and distribute equal amounts of light at each level and designing collectors to improve the effectiveness of vertical light pipes in delivering low elevation sunlight to the interior. Extraction was achieved by inserting partially reflecting cones within transparent sections of the pipes at each floor level. Theory was formulated to estimate the partial reflectance necessary to provide equal light extraction at each level. Designs for daylight collectors formed from laser cut panels tilted above the light pipe were developed and the benefits and limitations of static collectors as opposed to collectors that follow the sun azimuth investigated. Performance was assessed with both basic and detailed mathematical simulation and by observations made with a five level model building under clear sky conditions.