996 resultados para Medical Speech
Resumo:
Electronic Health Record (EHR) systems are being introduced to overcome the limitations associated with paper-based and isolated Electronic Medical Record (EMR) systems. This is accomplished by aggregating medical data and consolidating them in one digital repository. Though an EHR system provides obvious functional benefits, there is a growing concern about the privacy and reliability (trustworthiness) of Electronic Health Records. Security requirements such as confidentiality, integrity, and availability can be satisfied by traditional hard security mechanisms. However, measuring data trustworthiness from the perspective of data entry is an issue that cannot be solved with traditional mechanisms, especially since degrees of trust change over time. In this paper, we introduce a Time-variant Medical Data Trustworthiness (TMDT) assessment model to evaluate the trustworthiness of medical data by evaluating the trustworthiness of its sources, namely the healthcare organisation where the data was created and the medical practitioner who diagnosed the patient and authorised entry of this data into the patient’s medical record, with respect to a certain period of time. The result can then be used by the EHR system to manipulate health record metadata to alert medical practitioners relying on the information to possible reliability problems.
Resumo:
This study aimed to identify: i) the prevalence of malnutrition according to the scored Patient Generated-Subjective Global Assessment (PG-SGA); ii) utilization of available nutrition resources; iii) patient nutrition information needs; and iv) external sources of nutrition information. An observational, cross-sectional study was undertaken at an Australian public hospital on 191 patients receiving oncology services. According to PG-SGA, 49% of patients were malnourished and 46% required improved symptom management and/or nutrition intervention. Commonly reported nutrition-impact symptoms included: peculiar tastes (31%), no appetite (24%) and nausea (24%). External sources of nutrition information were accessed by 37%, with popular choices being media/internet (n=19) and family/friends (n=13). In a sub-sample (n=65), 32 patients were aware of the available nutrition resources, 23 thought the information sufficient and 19 patients had actually read them. Additional information on supplements and modifying side effects was requested by 26 patients. Malnutrition is common in oncology patients receiving treatment at an Australian public hospital and almost half require improved symptom management and/or nutrition intervention. Patients who read the available nutrition information found it useful, however awareness of these nutrition resources and the provision of information on supplementation and managing symptoms requires attention.
Resumo:
In this paper, cognitive load analysis via acoustic- and CAN-Bus-based driver performance metrics is employed to assess two different commercial speech dialog systems (SDS) during in-vehicle use. Several metrics are proposed to measure increases in stress, distraction and cognitive load and we compare these measures with statistical analysis of the speech recognition component of each SDS. It is found that care must be taken when designing an SDS as it may increase cognitive load which can be observed through increased speech response delay (SRD), changes in speech production due to negative emotion towards the SDS, and decreased driving performance on lateral control tasks. From this study, guidelines are presented for designing systems which are to be used in vehicular environments.
Resumo:
Objective: The emergency medical system (EMS) can be defined as a comprehensive, coordinated and integrated system of care for patients suffering acute illness and injury. The aim of the present paper is to describe the evolution of the Queensland Emergency Medical System (QEMS) and to recommend a strategic national approach to EMS development. Methods: Following the formation of the Queensland Ambulance Service in 1991, a state EMS committee was formed. This committee led the development and approval of the cross portfolio QEMS policy framework that has resulted in dynamic policy development, system monitoring and evaluation. This framework is led by the Queensland Emergency Medical Services Advisory Committee. Results: There has been considerable progress in the development of all aspects of the EMS in Queensland. These developments have derived from the improved coordination and leadership that QEMS provides and has resulted in widespread satisfaction by both patients and stakeholders. Conclusions: The strategic approach outlined in the present paper offers a model for EMS arrangements throughout Australia. We propose that the Council of Australian Governments should require each state and Territory to maintain an EMS committee. These state EMS committees should have a broad portfolio of responsibilities. They should provide leadership and direction to the development of the EMS and ensure coordination and quality of outcomes. A national EMS committee with broad representation and broad scope should be established to coordinate the national development of Australia's EMS.
Resumo:
The Autistic Behavioural Indicators Instrument (ABII) is an 18-item instrument developed to identify children with Autistic Disorder (AD) based on the presence of unique autistic behavioural indicators. The ABII was administered to 20 children with AD, 20 children with speech and language impairment (SLI) and 20 typically developing (TD) children aged 2-6 years. Results indicated that the ABII discriminated children diagnosed with AD from those diagnosed with SLI and those who were TD, based on the presence of specific social attention, sensory, and behavioural symptoms. A combination of symptomology across these domains correctly classified 100% of children with and without AD. The paper concludes that the ABII shows considerable promise as an instrument for the early identification of AD.
Resumo:
Objective: To systematically review the published evidence of the impact of health information technology (HIT) on the quality of medical and health care specifically clinicians’ adherence to evidence-based guidelines and the corresponding impact this had on patient clinical outcomes. In order to be as inclusive as possible the research examined literature discussing the use of health information technologies and systems in both medical care such as clinical and surgical, and other health care such as allied health and preventive services.----- Design: Systematic review----- Data Sources: Relevant literature was systematically searched on English language studies indexed in MEDLINE and CINAHL(1998 to 2008), Cochrane Library, PubMed, Database of Abstracts of Review of Effectiveness (DARE), Google scholar and other relevant electronic databases. A search for eligible studies (matching the inclusion criteria) was also performed by searching relevant conference proceedings available through internet and electronic databases, as well as using reference lists identified from cited papers.----- Selection criteria: Studies were included in the review if they examined the impact of Electronic Health Record (EHR), Computerised Provider Order-Entry (CPOE), or Decision Support System (DS); and if the primary outcomes of the studies were focused on the level of compliance with evidence-based guidelines among clinicians. Measures could be either changes in clinical processes resulting from a change of the providers’ behaviour or specific patient outcomes that demonstrated the effectiveness of a particular treatment given by providers. ----- Methods: Studies were reviewed and summarised in tabular and text form. Due to heterogeneity between studies, meta-analysis was not performed.----- Results: Out of 17 studies that assessed the impact of health information technology on health care practitioners’ performance, 14 studies revealed a positive improvement in relation to their compliance with evidence-based guidelines. The primary domain of improvement was evident from preventive care and drug ordering studies. Results from the studies that included an assessment for patient outcomes however, were insufficient to detect either clinically or statistically important improvements as only a small proportion of these studies found benefits. For instance, only 3 studies had shown positive improvement, while 5 studies revealed either no change or adverse outcomes.----- Conclusion: Although the number of included studies was relatively small for reaching a conclusive statement about the effectiveness of health information technologies and systems on clinical care, the results demonstrated consistency with other systematic reviews previously undertaken. Widescale use of HIT has been shown to increase clinician’s adherence to guidelines in this review. Therefore, it presents ongoing opportunities to maximise the uptake of research evidence into practice for health care organisations, policy makers and stakeholders.
Resumo:
In this study, a nanofiber mesh made by co-electrospinning medical grade poly(epsilon-caprolactone) and collagen (mPCL/Col) was fabricated and studied. Its mechanical properties and characteristics were analyzed and compared to mPCL meshes. mPCL/Col meshes showed a reduction in strength but an increase in ductility when compared to PCL meshes. In vitro assays revealed that mPCL/Col supported the attachment and proliferation of smooth muscle cells on both sides of the mesh. In vivo studies in the corpus cavernosa of rabbits revealed that the mPCL/Col scaffold used in conjunction with autologous smooth muscle cells resulted in better integration with host tissue when compared to cell free scaffolds. On a cellular level preseeded scaffolds showed a minimized foreign body reaction.
Resumo:
In an automotive environment, the performance of a speech recognition system is affected by environmental noise if the speech signal is acquired directly from a microphone. Speech enhancement techniques are therefore necessary to improve the speech recognition performance. In this paper, a field-programmable gate array (FPGA) implementation of dual-microphone delay-and-sum beamforming (DASB) for speech enhancement is presented. As the first step towards a cost-effective solution, the implementation described in this paper uses a relatively high-end FPGA device to facilitate the verification of various design strategies and parameters. Experimental results show that the proposed design can produce output waveforms close to those generated by a theoretical (floating-point) model with modest usage of FPGA resources. Speech recognition experiments are also conducted on enhanced in-car speech waveforms produced by the FPGA in order to compare recognition performance with the floating-point representation running on a PC.
Resumo:
Secondary tasks such as cell phone calls or interaction with automated speech dialog systems (SDSs) increase the driver’s cognitive load as well as the probability of driving errors. This study analyzes speech production variations due to cognitive load and emotional state of drivers in real driving conditions. Speech samples were acquired from 24 female and 17 male subjects (approximately 8.5 h of data) while talking to a co-driver and communicating with two automated call centers, with emotional states (neutral, negative) and the number of necessary SDS query repetitions also labeled. A consistent shift in a number of speech production parameters (pitch, first format center frequency, spectral center of gravity, spectral energy spread, and duration of voiced segments) was observed when comparing SDS interaction against co-driver interaction; further increases were observed when considering negative emotion segments and the number of requested SDS query repetitions. A mel frequency cepstral coefficient based Gaussian mixture classifier trained on 10 male and 10 female sessions provided 91% accuracy in the open test set task of distinguishing co-driver interactions from SDS interactions, suggesting—together with the acoustic analysis—that it is possible to monitor the level of driver distraction directly from their speech.
Resumo:
The law recognises the right of a competent adult to refuse medical treatment even if this will lead to death. Guardianship and other legislation also facilitates the making of decisions to withhold or withdraw life-sustaining treatment in certain circumstances. Despite this apparent endorsement that such decisions can be lawful, doubts have been raised in Queensland about whether decisions to withhold or withdraw life-sustaining treatment would contravene the criminal law, and particularly the duty imposed by the Criminal Code (Qld) to provide the “necessaries of life”. This article considers this tension in the law and examines various arguments that might allow for such decisions to be made lawfully. It ultimately concludes, however, that criminal responsibility may still arise and so reform is needed.
Resumo:
Purpose: The classic study of Sumby and Pollack (1954, JASA, 26(2), 212-215) demonstrated that visual information aided speech intelligibility under noisy auditory conditions. Their work showed that visual information is especially useful under low signal-to-noise conditions where the auditory signal leaves greater margins for improvement. We investigated whether simulated cataracts interfered with the ability of participants to use visual cues to help disambiguate the auditory signal in the presence of auditory noise. Methods: Participants in the study were screened to ensure normal visual acuity (mean of 20/20) and normal hearing (auditory threshold ≤ 20 dB HL). Speech intelligibility was tested under an auditory only condition and two visual conditions: normal vision and simulated cataracts. The light scattering effects of cataracts were imitated using cataract-simulating filters. Participants wore blacked-out glasses in the auditory only condition and lens-free frames in the normal auditory-visual condition. Individual sentences were spoken by a live speaker in the presence of prerecorded four-person background babble set to a speech-to-noise ratio (SNR) of -16 dB. The SNR was determined in a preliminary experiment to support 50% correct identification of sentence under the auditory only conditions. The speaker was trained to match the rate, intensity and inflections of a prerecorded audio track of everyday speech sentences. The speaker was blind to the visual conditions of the participant to control for bias.Participants’ speech intelligibility was measured by comparing the accuracy of their written account of what they believed the speaker to have said to the actual spoken sentence. Results: Relative to the normal vision condition, speech intelligibility was significantly poorer when participants wore simulated catarcts. Conclusions: The results suggest that cataracts may interfere with the acquisition of visual cues to speech perception.