969 resultados para Measuring method


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new method for measuring the coefficient of friction between nonwoven materials and the curved surface of the volar forearm has been developed and validated. The method was used to measure the coefficient of static friction for three different nonwoven materials on the normal (dry) and over-hydrated volar forearms of five female volunteers (ages 18-44). The method proved simple to run and had good repeatability: the coefficient of variation (standard deviation expressed as a percentage of the mean) for triplets of repeat measurements was usually (80 per cent of the time) less than 10 per cent. Measurements involving the geometrically simpler configuration of pulling a weighted fabric sample horizontally across a quasi-planar area of volar forearm skin proved experimentally more difficult and had poorer repeatability. However, correlations between values of coefficient of static friction derived using the two methods were good (R = 0.81 for normal (dry) skin, and 0.91 for over-hydrated skin). Measurements of the coefficient of static friction for the three nonwovens for normal (dry) and for over-hydrated skin varied in the ranges of about 0.3-0.5 and 0.9-1.3, respectively. In agreement with Amontons' law, coefficients of friction were invariant with normal pressure over the entire experimental range (0.1-8.2 kPa).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An accurate description of sound propagation in a duct is important to obtain the sound power radiating from a source in both near and far fields. A technique has been developed and applied to decompose higher-order modes of sound emitted into a duct. Traditional experiments and theory based on two-sensor methods are limited to the plane-wave contribution to the sound field at low frequency. Due to the increase in independent measurements required, a computational method has been developed to simulate sensitivities of real measurements (e.g., noise) and optimize the set-up. An experimental rig has been constructed to decompose the first two modes using six independent measurements from surface, flush-mounted microphones. Experiments were initially performed using a loudspeaker as the source for validation. Subsequently, the sound emitted by a mixed-flow fan has been investigated and compared to measurements made in accordance with the internationally standardized in-duct fan measurement method. This method utilizes large anechoic terminations and a procedure involving averaging over measurements in space and time to account for the contribution from higher-order modes. The new method does not require either of these added complications and gives detail about the underlying modal content of the emitted sound.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An improved peak power method for measuring frequency responses of photodetectors in a self-heterodyne system consisting of a distributed Bragg reflector laser is proposed. The time-resolved spectrum technique is used to measure the peak power of the beat signal and the intrinsic linewidth of heat signal for calibration. The experimental results show that the impact of the thermal-induced frequency drift, which is the main reason for producing an error in measurement by conventional peak power method and spectrum power method, can be removed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We develop a swept frequency method for measuring the frequency response of photodetectors; (PDs) based on harmonic analysis. In this technique, a lightwave from a laser source is modulated by a radio-frequency (RF) signal via a Mach-Zehnder LiNbO3 modulator, and detected by a PD under test. The measured second-order harmonic of the RF signal contains information of the frequency responses and nonlinearities of the RF source, modulator, and PD. The frequency response of the PD alone is obtained by deducting the known frequency responses and nonlinearities of the RF source and modulator. Compared with the conventional swept frequency method, the measurement frequency range can be doubled using the proposed method. Experiment results show a good agreement between the measured results and those obtained using other techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a parametrically efficient method for measuring the entanglement of formation E-f in an arbitrarily given unknown two-qubit state rho(AB) by local operations and classical communication. The two observers, Alice and Bob, first perform some local operations on their composite systems separately, by which the desired global quantum states can be prepared. Then they estimate seven functions via two modified local quantum networks supplemented a classical communication. After obtaining these functions, Alice and Bob can determine the concurrence C and the entanglement of formation E-f.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

sing the result of model-solid theory, we have obtained the relationship between bandgap and strain of Si1-x Ge-x alloy on Si (100) substrate with x < 0.85. It was shown that the deviation between the bandgap of strained SiGe and relaxed SiGe is proportional to the strain. According to the theoretical result, a novel method was suggested to determine the strain state of SiGe/ Si through measuring the bandgap. The strain in the SiGe/Si multi-quantum wells was measured using the new method and the results had good agreement with that from XRD measurement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The transient charge response Q(t) of a two-dimensional electron gas (2DEG) in GaAs/AlxGa1-xAs heterostructures to a small pulse of the gate voltage, applied between the top gate and source electrodes in a Corbino structure, was employed to directly measure the effective diffusion constant of a 2DEG in the quantum Hall regime. The measured diffusion constant D showed a drastic change as the magnetic field was swept through the integer fillings of the Landau levels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new method of measuring the mean size of solvent clusters in swollen polymer membrane is presented in this paper. This method is based on a combination of inverse gas chromatography (IGC) and equilibrium swelling. The mechanism is that weight fraction activity coefficient of solvent in swollen polymer is influenced by its clusters size. The mean clusters size of solvent in swollen polymer can be calculated as the quotient of the weight fraction activity coefficient of clustering system dividing the weigh fraction activity coefficient of non-clustering system. In this experiment, the weigh fraction activity coefficient of non-clustering system was measured with IGC. Methanol, ethanol and polyimide systems were tested with the new method at three temperatures, 20, 40, and 60degreesC. The mean clusters size of methanol in polyimide was five, four, and three at each temperature condition, respectively. Ethanol did not form clusters (the mean clusters size was one). In contrast to the inherent narrow temperature range in DSC, XRD, and FTIR methods, the temperature range in IGC and equilibrium swelling is broad. Compared with DSC. XRD. and FTIR, this new method can detect the clusters of solvent-polymer system at higher temperature.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper introduces a new method to estimate the diffusion coefficient and transference number of a salt or an electroactive ion in a solution with little or no supporting electrolyte. The above two parameters can be obtained from a single potential step experiment without previous knowledge of either one. It would appear that the method could also be used in the study of ion transport in a high viscosity solvent or a solid electrolyte. (C) 1998 Elsevier Science S.A.