969 resultados para Matrix Effects


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A dispersive liquid-liquid microextraction procedure coupled to spectrophotometry is described for the determination of the trace levels of Sudan Blue II. Analytical parameters, such as pH, volume of extraction solvent (carbon tetrachloride), volume of dispersant (ethanol), volume of sample, and extraction time, were optimized. Matrix effects were also investigated. Preconcentration factor was found to be 200. Detection limit and relative standard deviation (RSD) were 0.55 µg L-1 and 3.9%, respectively. The procedure was successfully used for the determination of trace levels of Sudan Blue II in food, ink, antifreeze, and industrial waste-water samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method for determination of organohalogen pesticides in strawberry by gas chromatography with electron capture detection was validated and applied in a monitoring program. Linearity, matrix effects, and day effect were evaluated for the analytes alpha-endosulfan, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone, and trifluralin. The linear range varied according to the chromatographic response of the analyte. Significant matrix effects were observed. The mean recoveries ranged from 74.6 to 115.4%, with repeatability standard deviations between 1.6 and 21.0% and intermediate precision between 5.9 and 21.0%. Detection, quantification and decision limit, and detection capacity ranged from 0.003 to 0.007 mg/kg, 0.005 to 0.013 mg/kg; 0.003 to 3.128 mg/kg; and 0.005 to 3.266 mg/kg, respectively. The method was fit for the purpose of monitoring organohalogen residues in strawberries. Residues of these pesticides were detected in 124 of the 186 samples analyzed between 2009 and 2011 in the state of Minas Gerais. Nine of them did not comply with the current legislation requirements; among them, seven (3.8%) had residues of unauthorized pesticide for the culture of strawberry, one (0.5%) had residues above the maximum residue limit, and another one (0.5%) exhibited both non-conformities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’utilisation accrue des nanomatériaux manufacturés (NM) fait en sorte que les différents acteurs de réglementation se questionnent de plus en plus par rapport à leur destin et leurs impacts sur les écosystèmes et la santé humaine suite à leur rejet dans l’environnement. Le développement de techniques analytiques permettant de détecter et de caractériser les NM en matrice environnementale est impératif étant donné la nécessité d’évaluer le risque relié à ces polluants émergents. Une des approches de plus en plus favorisée est d’utiliser une technique chromatographique et un ou plusieurs détecteurs sensibles dans les buts de réduire les effets de matrice, d’identifier des nanoparticules (NP) selon leurs temps de rétention et de les quantifier à des concentrations représentatives de la réalité environnementale. Une technique analytique utilisant la chromatographie hydrodynamique (HDC) et des détecteurs en ligne ou hors ligne (détecteurs de diffusion statique ou dynamique de la lumière, spectromètre de masse par torche à plasma en mode particule unique (SP-ICPMS), l’ultracentrifugation analytique) a donc été développée. Le couplage de la colonne HDC avec ces détecteurs a permis de caractériser des NP standards et l’optimisation des conditions de séparation de ces nanoparticules de polystyrène, d’or et d’argent a permis de confirmer que les NP y sont bel et bien séparées seulement selon leur taille, tel que la théorie le prédit. De plus, l’utilisation de la colonne HDC couplée au SP-ICPMS a permis de séparer un mélange de nanoparticules d’argent (nAg) et de les détecter à des concentrations représentatives de celles rencontrées dans l’environnement, soit de l’ordre du μg L-1 au ng L-1. Par exemple, dans un échantillon d’eau usée (effluent), un mélange de nAg de 80 et de 40 nm a été séparé et les nAg ont été détectées à l’aide du SP-ICPMS connecté à la colonne HDC (temps de rétention de 25.2 et 25.6 minutes et diamètres déterminés de 71.4 nm et 52.0 nm). Finalement, pour plusieurs échantillons environnementaux auxquels aucun ajout de nanoparticules n’a été fait, les analyses HDC-SP-ICPMS effectuées ont permis de déterminer qu’ils ne contenaient initialement pas de nAg.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new compact system encompassing in flow gas diffusion unit and a wall-jet amperometric FIA detector, coated with a supramolecular porphyrin film, was specially designed as an alternative to the time-consuming Monier-Williams method, allowing fast, reproducible and accurate analyses of free sulphite species in fruit juices. In fact, a linear response between 0.64 and 6.4 ppm of sodium sulphite. LOD = 0.043 ppm, relative standard deviation of +/- 1.5% (n = 10) and analytical frequency of 85 analyses/h were obtained utilising optimised conditions. That superior analytical performance allows the precise evaluation of the amount of free sulphite present in foods, providing an important comparison between the standard addition and the standard injection methods. Although the first one is most frequently used, it was strongly influenced by matrix effects because of the unexpected reactivity of sulphite ions with the juice matrixes, leading to its partial consumption soon after addition. In contrast, the last method was not susceptible to matrix effects yielding accurate results, being more reliable for analytical purposes. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pyrolytic graphite electrodes (PGE) were modified into dopamine solutions using phosphate buffer solutions, pH 10 and 6.5, as supporting electrolyte. The modification process involved a previous anodization of the working electrode at +1. 5 V into 0. 1 mol-L-1 NaOH followed by other anodization step, in the same experimental conditions, into dopamine (DA) solutions. pH of the supporting electrolyte performed an important role in the production of a superficial melanin polymeric film, which permitted the simultaneous detection of ascorbic acid (AA), (DA) and uric acid (UA), Delta EAA-DA = 222 mV-, Delta EAA-UA = 360 mV and Delta EDA-UA=138mV, avoiding the superficial poisoning effects. The calculated detection limits were: 1.4 x 10(-6) mol L-1 for uric acid, 1.3x10-(5) molL(-1) for ascorbic acid and 1.1 X 10(-7) mol L-1 for dopamine, with sensitivities of (7.7 +/- 0.5), (0.061 +/- 0.001) and (9.5 +/- 0.05)A mol(-1) cm(-2), respectively, with no mutual interference. Uric acid was determined in urine, blood and serum human samples after dilution in phosphate buffer and no additional sample pre-treatment was necessary. The concentration of uric acid in urine was higher than the values found in blood and serum and the recovery tests (92-102%) indicated that no matrix effects were observed. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports on the development and optimization of a modified Quick, Easy, Cheap Effective, Rugged and Safe (QuEChERS) based extraction technique coupled with a clean-up dispersive-solid phase extraction (dSPE) as a new, reliable and powerful strategy to enhance the extraction efficiency of free low molecular-weight polyphenols in selected species of dietary vegetables. The process involves two simple steps. First, the homogenized samples are extracted and partitioned using an organic solvent and salt solution. Then, the supernatant is further extracted and cleaned using a dSPE technique. Final clear extracts of vegetables were concentrated under vacuum to near dryness and taken up into initial mobile phase (0.1% formic acid and 20% methanol). The separation and quantification of free low molecular weight polyphenols from the vegetable extracts was achieved by ultrahigh pressure liquid chromatography (UHPLC) equipped with a phodiode array (PDA) detection system and a Trifunctional High Strength Silica capillary analytical column (HSS T3), specially designed for polar compounds. The performance of the method was assessed by studying the selectivity, linear dynamic range, the limit of detection (LOD) and limit of quantification (LOQ), precision, trueness, and matrix effects. The validation parameters of the method showed satisfactory figures of merit. Good linearity (View the MathML sourceRvalues2>0.954; (+)-catechin in carrot samples) was achieved at the studied concentration range. Reproducibility was better than 3%. Consistent recoveries of polyphenols ranging from 78.4 to 99.9% were observed when all target vegetable samples were spiked at two concentration levels, with relative standard deviations (RSDs, n = 5) lower than 2.9%. The LODs and the LOQs ranged from 0.005 μg mL−1 (trans-resveratrol, carrot) to 0.62 μg mL−1 (syringic acid, garlic) and from 0.016 μg mL−1 (trans-resveratrol, carrot) to 0.87 μg mL−1 ((+)-catechin, carrot) depending on the compound. The method was applied for studying the occurrence of free low molecular weight polyphenols in eight selected dietary vegetables (broccoli, tomato, carrot, garlic, onion, red pepper, green pepper and beetroot), providing a valuable and promising tool for food quality evaluation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development of more selective and sensitive analytical methods is of great importance in different areas of knowledge, covering, for example, food, biotechnological, environmental and pharmaceutical sectors. The study aimed to employ the technique electroanalytical differential pulse voltammetry (DPV) as an innovative and promising alternative for identification and quantification of organic compounds. The organic compounds were investigated in this study oxalic acid (OA) and folic acid (FA). The electrochemical oxidation of oxalic acid has been extensively studied as a model reaction in the boundary between the organic and inorganic electrochemistry. Since the AF, an essential vitamin for cell multiplication in all tissues, which is essential for DNA synthesis. The AF has been investigated using analytical techniques, liquid chromatography and molecular absorption spectrophotometry. The results obtained during the experimental procedure indicated that the process of electrochemical oxidation of oxalic acid is strongly dependent on the nature of the anode material and the oxidation mechanism, which affects their detection. Efficient removal was observed in Ti/PbO2 anodes, graphite, BDD and Pt 90, 85, 80 and 78% respectively. It was also shown that the DPV employing glassy carbon electrode offers a fast, simple, reliable and economical way to determine the AO during the process of electrochemical oxidation. Furthermore, electroanalytical methods are more expensive than commonly used chromatographic analysis and other instrumental methods involving toxic reagents and higher cost. Compared with the classical method of titration and DPV could be a good fit, confidence intervals and detection limits confirming the applicability of electroanalytical technique for monitoring the degradation of oxalic acid. For the study of AF was investigated the electrocatalytic activity of the carbon paste electrode for identification and quantification in pharmaceutical formulations by applying the DPV. The results obtained during the experimental procedure showed an irreversible oxidation peak at 9.1 V characteristic of FA. The carbon paste sensor showed low detection limit of 5.683×10−8 mol L-1 reducing matrix effects. The spectrophotometric analysis showed lower concentrations of HF compared with those obtained by HPLC and DPV. The levels of AF were obtained according to the methodology proposed by the Brazilian Pharmacopoeia. The electroanalytical method (DPV) proposed is cheaper than GC analysis commonly used by the pharmaceutical industry. The results demonstrated the potential of these electroanalytical techniques for future applications in environmental, chemical and biological sensors

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enzyme-linked immunosorbent assays (ELISAs) are the most extensively studied types of immunoassay and their application in pesticide residue monitoring is an area with enormous potential for growth. In comparison with classical analytical methods, ELISA methods offer the possibility of highly sensitive, relatively rapid, and cost-effective measurements. This review introduces the general ELISA formats used, focusing on their use in pesticide analysis. Identifying and studying the effects of interferences in immunoassays is an active area of research and we discuss the matrix effects observed in several studies involving e.g. food, crop and environmental samples. The procedures to eliminate the matrix interferences are briefly discussed. (C) 1998 Elsevier B.V. B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of Saccharomyces cerevisiae as a sorbent material to separate Cd(II) and Cd-metallothionein complex (Cd-MT) has been explored. Solid-liquid phase extractions were carried out in batch mode and the main parameters of the process (pH, temperature, time of incubation, amount of biomass and analyte) were evaluated. Under optimized conditions, the yeast quantitatively retain (94 +/- 5%) the Cd(II) while 97 +/- 2% of the Cd-MT remain in the supernatant. on base of the findings of this study, a simple method is proposed to determine Cd(II) and Cd-MT in cytosols extracted from mouse kidney and crab hepatopancreas. Inductively coupled plasma optical emission spectrometry was used to quantify the analytes in solid and liquid phase. Determination of Cd in the solid phase was carried out by introducing a slurry of the yeast (0.0625 g/10 mL) directly to the inductively coupled plasma optical emission spectrometer. Mixed standards solutions, which also have been submitted to the extraction procedure, were used to quantify the analytes in the samples. Thus, matrix effects due to nebulization of the slurry were overcame. Limits of detection (3 sigma) for Cd(II) and Cd-MT were 1.5 and 1.2 mu g L-1, respectively. Relative standard deviations of signals were 4.2% for measurements in the slurry of solid phase and 2.1% for measurements in the liquid phase. Recoveries of the analytes in cytosol samples were between 76 and 114%. The concentrations of Cd(II) (2.4 +/- 0.5 mu g L-1) and Cd-MT (3.0 +/- 0.5 mu g L-1) found by using the proposed approach were close to those found by tangential-flow ultrafiltration technique (2.6 +/- 0.7 mu g L-1 for Cd(II) and 3.7 +/- 1.7 mu g L-1 for Cd-MT).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An on-line dialysis flow system coupled to inductively coupled plasma mass spectrometry to determine trace elements in serum samples by isotope dilution is presented. Isotope dilution was performed on samples incubated with enriched Cu-65, Zn-66, Se-77 and Pb-206 for 24 h at 36degreesC prior to dialysis to quantified total element concentrations. The sample and acceptor solutions flowed through the dialysis unit with cellophane membrane placed in between the compartments. The serum sample (1 mL) was left to recycle in a closed path while the acceptor solution was continuously pumped along the dialyzer channel and through a cationic AG50W X-8 resin column. After 10 min, around 70% of Na, K and Cl migrate from the sample. Three replicate injections of 0.1 mL were performed for the clean sample after each separation step. The on-line coupling of the dialyzer to ICP-MS allowed isotope dilution for total element determination either in the cleaned sample or by eluting the cations retained in the resin to be carried out. Results demonstrated no matrix effects from alkaline elements or spectral interference from ArNa+ on Cu-63, ArCl+ on Se-77 and (SO2+)-S-34 on Zn-66. The precision of isotope ratio measurements for Cu and Zn was around 1% and for Se and Pb was around 2.5%. The values found for the reference serum sample IMEP-17 were in good agreement with the certified values for Cu, Zn and Se.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An analytical procedure for direct introduction of biodiesel samples into an inductively coupled plasma mass spectrometer (ICP-MS) by using microemulsion for sample preparation was developed here. Cadmium, Co, Cu, Mn, Ni, Pb, Ti, and Zn were determined in biodiesel microemulsified samples prepared from different oleaginous sources (African palm, castor beans, palm, soybeans and an unknown oleaginous). Microemulsions were prepared using 0.25 mL Triton X-100, 0.25 mL 20% v v(-1) HNO(3), 0.50 mL biodiesel sample and 4.0 mL n-propanol. Argon-oxygen mixture was added to the plasma as auxiliary gas for correcting matrix effects caused by the high carbon load due to biodiesel microemulsions. The oxygen gas flow rate was set in 37.5 mL min(-1). The accuracy of the developed procedure was evaluated by applying addition-recovery experiments for biodiesel samples from different sources. Recoveries varied from 76.5 to 116.2% for all analytes but Zn in castor beans biodiesel sample (65.0 to 76.2%). Recoveries lower than 86.6% were obtained for palm biodiesel sample, probably due to matrix effects. Detection limits calculated by using oxygen in the composition of the auxiliary gas added to the plasma were higher than those calculated without using it, probably due to the highest formation of oxides. Despite oxides formation, best analytical performance was reached by using oxygen as auxiliary gas and by proper correction of transport interferences. The developed procedure based on microemulsion formation was suitable for direct introduction of biodiesel samples in ICP-MS. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Biologia Vegetal) - IBRC