944 resultados para MULTIAXIAL LOADS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design evolution process of a composite leaf spring for freight rail applications. Three designs of eye-end attachment for composite leaf springs are described. The material used is glass fibre reinforced polyester. Static testing and finite element analysis have been carried out to obtain the characteristics of the spring. Load-deflection curves and strain measurement as a function of load for the three designs tested have been plotted for comparison with FEA predicted values. The main concern associated with the first design is the delamination failure at the interface of the fibres that have passed around the eye and the spring body, even though the design can withstand 150 kN static proof load and one million cycles fatigue load. FEA results confirmed that there is a high interlaminar shear stress concentration in that region. The second design feature is an additional transverse bandage around the region prone to delamination. Delamination was contained but not completely prevented. The third design overcomes the problem by ending the fibres at the end of the eye section.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The River Lugg has particular problems with high sediment loads that have resulted in detrimental impacts on ecology and fisheries. A new dynamic, process-based model of hydrology and sediments (INCA- SED) has been developed and applied to the River Lugg system using an extensive data set from 1995–2008. The model simulates sediment sources and sinks throughout the catchment and gives a good representation of the sediment response at 22 reaches along the River Lugg. A key question considered in using the model is the management of sediment sources so that concentrations and bed loads can be reduced in the river system. Altogether, five sediment management scenarios were selected for testing on the River Lugg, including land use change, contour tillage, hedging and buffer strips. Running the model with parameters altered to simulate these five scenarios produced some interesting results. All scenarios achieved some reduction in sediment levels, with the 40% land use change achieving the best result with a 19% reduction. The other scenarios also achieved significant reductions of between 7% and 9%. Buffer strips produce the best result at close to 9%. The results suggest that if hedge introduction, contour tillage and buffer strips were all applied, sediment reductions would total 24%, considerably improving the current sediment situation. We present a novel cost-effectiveness analysis of our results where we use percentage of land removed from production as our cost function. Given the minimal loss of land associated with contour tillage, hedges and buffer strips, we suggest that these management practices are the most cost-effective combination to reduce sediment loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of quasi-static and dynamic testing of glass fiber-reinforced polyester leaf suspension for rail freight vehicles named Euroleaf. The principal elements of the suspension's design and manufacturing process are initially summarized. Comparison between quasi-static tests and finite element predictions are then presented. The Euroleaf suspension have been mounted on a tipper wagon and tested dynamically at tare and full load on a purpose-built shaker rig. A shaker rig dynamic testing methodology has been pioneered for rail vehicles, which follows closely road vehicle suspension dynamic testing methodology. The use and evaluation of this methodology have demonstrated that the Euroleaf suspension is dynamically much softer than steel suspensions even though it is statically much stiffer. As a consequence, the suspension dynamic loading at laden loading conditions is reduced compared to the most advanced steel leaf suspension over shaker rig track tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Mar Menor is a coastal lagoon increasingly threatened by urban and agricultural pressures. The main watercourse draining into the lagoon is the Rambla del Albujón. A fortnightly campaign carried out over one annual cycle enabled us to characterize the treated urban sewage effluents and agricultural sources which contribute to the nutrient fluxes in the watercourse. Multivariate analysis provided information for establishing chemical signatures and for assessing the relative influence of the various sources on the water quality at the outlet. Mass balances were used to examine net gains and losses, and cross-correlations with rainfall to analyze climatic influence and control factors in the trends of the nutrient flux. The rainfall pattern was significantly cross-correlated with nitrate and phosphorus fluxes from agricultural sources, while fluctuations in the resident population explained the phosphorus flux trend in urban sources. 50% of dissolved inorganic nitrogen was from agricultural sources, while 70% of total phosphate and 91% of total organic carbon were from urban point sources. The net amounts of all the nutrients fell as a result of plant uptake and/or denitrification in the channel. The control of urban point sources (phosphorus-enriched) is suggested as a promptly action for improving the health of the coastal lagoon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a power management strategy (PMS) has been developed for the control of energy storage in a system subjected to loads of random duration. The PMS minimises the costs associated with the energy consumption of specific systems powered by a primary energy source and equipped with energy storage, under the assumption that the statistical distribution of load durations is known. By including the variability of the load in the cost function, it was possible to define the optimality criteria for the power flow of the storage. Numerical calculations have been performed obtaining the control strategies associated with the global minimum in energy costs, for a wide range of initial conditions of the system. The results of the calculations have been tested on a MATLAB/Simulink model of a rubber tyre gantry (RTG) crane equipped with a flywheel energy storage system (FESS) and subjected to a test cycle, which corresponds to the real operation of a crane in the Port of Felixstowe. The results of the model show increased energy savings and reduced peak power demand with respect to existing control strategies, indicating considerable potential savings for port operators in terms of energy and maintenance costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate plantar pressure distribution in individuals with and without Patellofemoral Pain Syndrome during the Support phase of stair descent. Design: Observational case-control study. Participants: 30 Young adults With Patellofemoral Pain Syndrome and 44 matched controls. Main outcome measures: Contact area, peak pressure and pressure-time integral (Novel Pedar-X system) were evaluated in six plantar areas (medial, central and lateral rearfoot: midfoot; medial and lateral forefoot) during stair descent. Results: Contact area was greater in the Patellofemoral Pain Syndrome Group at medial rearfoot (p = 0.019) and midfoot (p < 0.001). Subjects with Patellofemoral pain Syndrome presented smaller peak pressures (p < 0.001). Conclusion: The pattern of plantar pressure distribution during stair descent in Patellofemoral Pain Syndrome Subjects was different from controls. This seems to be related to greater medial rearfoot and midfoot Support. Smaller plantar loads found in Patellofemoral Pain Syndrome subjects during stair descent reveal a more Cautious motor pattern in a challenging task. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of the SenseWear (TM) armband (SWA), an objective monitor of physical activity, is a relatively new device used by researchers to measure energy expenditure. These monitors are practical, relatively inexpensive and easy-to-use. The aim of the present study was to assess the validity of SWAs for the measurement of energy expenditure (EE) in circuit resistance training (CRT) at three different intensities in moderately active, healthy subjects. The study subjects (17 females, 12 males) undertook CRT at 30, 50 and 70% of the 15 repetition maximum for each exercise component wearing an SWA as well as an Oxycon Mobile (OM) portable metabolic system (a gold standard method for measuring EE). The EE rose as exercise intensity increased, but was underestimated by the SWAs. For women, Bland-Altman plots showed a bias of 1.13 +/- A 1.48 METs and 32.1 +/- A 34.0 kcal in favour of the OM system, while for men values of 2.33 +/- A 1.82 METs and 75.8 +/- A 50.8 kcal were recorded.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Millon describes the normal personality by means of adaptation styles that are effective in normal environments and personality disorders such as unadapted operating styles. To operacionalize his theoretical model, Millon has built several instruments, including the Millon Clinical Multiaxial Inventory III (MCMI-III), wich consists of a self report inventory composed by 175 true or false response items, containing four verification scales, and others scales wich evaluates 14 personality patterns and 10 clinical syndromes. The Substance Dependence scale (T) is placed along with Clinical Syndromes scales. This research is justified by the lack of a Brazilian instrument to assess personality psychopathological aspects, and aims to translate and semantically adapt the MCMI-III to the Brazilian context, checking validity elements of the Substance Dependence scale, and developing a computer application for assisting the evaluation of assessment results. To this intent, 2.588 individuals data was collected, male and female, aged between 18 and 85 years, characterized as belonging to a clinical or non-clinical group, who took part in the survey via the internet or in person. Respondents completed the MCMI-III, a socio-demographic questionnaire and a subgroup also answered to the Goldberg General Health Questionnaire (GHQ). Besides descriptive statistics, we performed the analysis using the Student t test, principal components analysis and internal consistency. Despite difficulties related to translating very specific English terms, the assessment by judges, experts on Millon´s theory, and the back translation, attested the adequacy of the Brazilian version. Factorial analysis indicated the grouping of translated T scale items into three factors (social activities prejudice, lack of impulse control, and oppositional behavior), by presenting a single item on a fourth factor (apparently related to seeking pleasurable stimuli). The Cronbach alpha for this set of items was 0,82, indicating an acceptable scale reliability. The data analysis resulted in distinction of scores between clinical and non-clinical groups and between men and women; the relationship between high scores on the scale T and the other scales; scores of drug users according to the declared used substance; and the relationship between high scores on T and the verification of disorder or risk on GHQ mental health factor, indicating the instrument´s adequate sensistivity in identifying psychopathologies and the relationship between the different disorders or psychopathological personality patterns. Although further studies are necessary to develop the scores transformation factors, the computerized correction tool was adequate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study has as main objectives to translate and to adapt the MCMI-III to brazilian Portuguese, as well as investigate and analyze the involved modifications in the Alcohol Dependence Scale concerning to the results obtained on the validity and on the process of adaptation to Brazil. The inventory was translated and, posteriorly, applied on people with different reading levels to certify that the items are understandable to public in general, from diverse places of the country, divided into clinical and non-clinical groups. Were evaluated 2855 subjects between the ages of 18 and 85 years old, male and female, resident and dwellers of Brazilian cities. The application methods were face-to-face and computerized. Results showed that the clinical group presented significant differences between the means in comparison to the non-clinical group. Through the application of the General Health Questionnaire were developed studies related to the achievement of convergent validity and its results pointed to the relation between the instrument scores and the MCMI-III. The Alcohol Dependence Scale analysis indicated that people who reported abusive use of alcohol had highest scores, indicating adequacy of the instrument on identifying manifestation of disorders and syndromes. Nevertheless, further studies are necessary to the establishment of normative patterns to the Brazilian sample

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 mu epsilon) and point D the highest (442.77 mu epsilon). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine the influence of cement thickness and ceramic/cement bonding on stresses and failure of CAD/CAM crowns, using both multi-physics finite element analysis and monotonic testing.Methods. Axially symmetric FEA models were created for stress analysis of a stylized monolithic crown having resin cement thicknesses from 50 to 500 mu m under occlusal loading. Ceramic-cement interface was modeled as bonded or not-bonded (cement-dentin as bonded). Cement polymerization shrinkage was simulated as a thermal contraction. Loads necessary to reach stresses for radial cracking from the intaglio surface were calculated by FEA. Experimentally, feldspathic CAD/CAM crowns based on the FEA model were machined having different occlusal cementation spaces, etched and cemented to dentin analogs. Non-bonding of etched ceramic was achieved using a thin layer of poly(dimethylsiloxane). Crowns were loaded to failure at 5 N/s, with radial cracks detected acoustically.Results. Failure loads depended on the bonding condition and the cement thickness for both FEA and physical testing. Average fracture loads for bonded crowns were: 673.5 N at 50 mu m cement and 300.6 N at 500 mu m. FEA stresses due to polymerization shrinkage increased with the cement thickness overwhelming the protective effect of bonding, as was also seen experimentally. At 50 mu m cement thickness, bonded crowns withstood at least twice the load before failure than non-bonded crowns.Significance. Occlusal "fit" can have structural implications for CAD/CAM crowns; pre-cementation spaces around 50-100 mu m being recommended from this study. Bonding benefits were lost at thickness approaching 450-500 mu m due to polymerization shrinkage stresses. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inverted flying exercise with external loads of 25, 50, 75 and 100% of each individual maximum load in the pectoralis major and deltoideus anterior muscles was electromyographically analyzed in eleven male volunteers, using surface electrodes MEDI-TRACE-200 connected to a biological signals acquisition module coupled to a PC/AT computer. Electromyographic signals were processed and the effective values obtained were standardized through maximum voluntary isometric contraction. When the concentric phase of each muscle with the same load was statistically compared with the eccentric phase, it was observed that for all loads all the muscles presented significant electromyographic difference, and that the concentric phase was always higher. By analyzing the different loads for each muscle, it was noticed that in the concentric phase all the muscles presented significant electromyographic activity, being it higher with maximum load. When the effect of each load on different muscle in the concentric and eccentric phases was analyzed, the muscles presented a distinct activity profile.