978 resultados para Laboratory measurements


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Radar refractivity retrievals can capture near-surface humidity changes, but noisy phase changes of the ground clutter returns limit the accuracy for both klystron- and magnetron-based systems. Observations with a C-band (5.6 cm) magnetron weather radar indicate that the correction for phase changes introduced by local oscillator frequency changes leads to refractivity errors no larger than 0.25 N units: equivalent to a relative humidity change of only 0.25% at 20°C. Requested stable local oscillator (STALO) frequency changes were accurate to 0.002 ppm based on laboratory measurements. More serious are the random phase change errors introduced when targets are not at the range-gate center and there are changes in the transmitter frequency (ΔfTx) or the refractivity (ΔN). Observations at C band with a 2-μs pulse show an additional 66° of phase change noise for a ΔfTx of 190 kHz (34 ppm); this allows the effect due to ΔN to be predicted. Even at S band with klystron transmitters, significant phase change noise should occur when a large ΔN develops relative to the reference period [e.g., ~55° when ΔN = 60 for the Next Generation Weather Radar (NEXRAD) radars]. At shorter wavelengths (e.g., C and X band) and with magnetron transmitters in particular, refractivity retrievals relative to an earlier reference period are even more difficult, and operational retrievals may be restricted to changes over shorter (e.g., hourly) periods of time. Target location errors can be reduced by using a shorter pulse or identified by a new technique making alternate measurements at two closely spaced frequencies, which could even be achieved with a dual–pulse repetition frequency (PRF) operation of a magnetron transmitter.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CFC-113a (CF3CCl3), CFC-112 (CFCl2CFCl2) and HCFC-133a (CF3CH2Cl) are three newly detected molecules in the atmosphere that are almost certainly emitted as a result of human activity. It is important to characterise the possible contribution of these gases to radiative forcing of climate change and also to provide information on the CO2-equivalence of their emissions. We report new laboratory measurements of absorption cross-sections of these three compounds at a resolution of 0.01 cm−1 for two temperatures 250 K and 295 K in the spectral range of 600–1730 cm−1. These spectra are then used to calculate the radiative efficiencies and global warming potentials (GWP). The radiative efficiencies are found to be between 0.15 and 0.3 W∙m−2∙ppbv−1. The GWP for a 100 year time horizon, relative to carbon dioxide, ranges from 340 for the relatively short-lived HCFC-133a to 3840 for the longer-lived CFC-112. At current (2012) concentrations, these gases make a trivial contribution to total radiative forcing; however, the concentrations of CFC-113a and HCFC-133a are continuing to increase. The 2012 CO2-equivalent emissions, using the GWP (100), are estimated to be about 4% of the current global CO2-equivalent emissions of HFC-134a

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent laboratory measurements show that absorption by the water vapour continuum in near-infrared windows may be about an order of magnitude higher than assumed in many radiation codes. The radiative impact of the continuum at visible and near-infrared wavelengths is examined for the present day and for a possible future warmer climate (with a global-mean total column water increase of 33%). The calculations use a continuum model frequently used in climate models (‘CKD’) and a continuum model where absorption is enhanced at wavelengths greater than 1 µm based on recent measurements (‘CAVIAR’). The continuum predominantly changes the partitioning between solar radiation absorbed by the surface and the atmosphere; changes in top-of-atmosphere net irradiances are smaller. The global-mean clear-sky atmospheric absorption is enhanced by 1.5 W m−2 (about 2%) and 2.8 W m−2 (about 3.5%) for CKD and CAVIAR respectively, relative to a hypothetical no-continuum case, with all-sky enhancements about 80% of these values. The continuum is, in relative terms, more important for radiation budget changes between the present day and a possible future climate. Relative to the no-continuum case, the increase in global-mean clear-sky absorption is 8% higher using CKD and almost 20% higher using CAVIAR; all-sky enhancements are about half these values. The effect of the continuum is estimated for the solar component of the water vapour feedback, the reduction in downward surface irradiance and precipitation change in a warmer world. For CKD and CAVIAR respectively, and relative to the no-continuum case, the solar component of the water vapour feedback is enhanced by about 4 and 9%, the change in clear-sky downward surface irradiance is 7 and 18% more negative, and the global-mean precipitation response decreases by 1 and 4%. There is a continued need for improved continuum measurements, especially at atmospheric temperatures and at wavelengths below 2 µm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Spectroscopic catalogues, such as GEISA and HITRAN, do not yet include information on the water vapour continuum that pervades visible, infrared and microwave spectral regions. This is partly because, in some spectral regions, there are rather few laboratory measurements in conditions close to those in the Earth’s atmosphere; hence understanding of the characteristics of the continuum absorption is still emerging. This is particularly so in the near-infrared and visible, where there has been renewed interest and activity in recent years. In this paper we present a critical review focusing on recent laboratory measurements in two near-infrared window regions (centred on 4700 and 6300 cm−1) and include reference to the window centred on 2600 cm−1 where more measurements have been reported. The rather few available measurements, have used Fourier transform spectroscopy (FTS), cavity ring down spectroscopy, optical-feedback – cavity enhanced laser spectroscopy and, in very narrow regions, calorimetric interferometry. These systems have different advantages and disadvantages. Fourier Transform Spectroscopy can measure the continuum across both these and neighbouring windows; by contrast, the cavity laser techniques are limited to fewer wavenumbers, but have a much higher inherent sensitivity. The available results present a diverse view of the characteristics of continuum absorption, with differences in continuum strength exceeding a factor of 10 in the cores of these windows. In individual windows, the temperature dependence of the water vapour self-continuum differs significantly in the few sets of measurements that allow an analysis. The available data also indicate that the temperature dependence differs significantly between different near-infrared windows. These pioneering measurements provide an impetus for further measurements. Improvements and/or extensions in existing techniques would aid progress to a full characterisation of the continuum – as an example, we report pilot measurements of the water vapour self-continuum using a supercontinuum laser source coupled to an FTS. Such improvements, as well as additional measurements and analyses in other laboratories, would enable the inclusion of the water vapour continuum in future spectroscopic databases, and therefore allow for a more reliable forward modelling of the radiative properties of the atmosphere. It would also allow a more confident assessment of different theoretical descriptions of the underlying cause or causes of continuum absorption.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Direct measurements in the last decades have highlighted a new problem related to the lowering of the Coulomb barrier between the interacting nuclei due to the presence of the ""electron screening"" in the laboratory measurements. It was systematically observed that the presence of the electronic cloud around the interacting ions in measurements of nuclear reactions cross sections at astrophysical energies gives rise to an enhancement of the astrophysical S(E)-factor as lower and lower energies are explored [1]. Moreover, at present Such an effect is not well understood as the value of the potential for screening extracted from these measurements is higher than the tipper limit of theoretical predictions (adiabatic limit). On the other hand, the electron screening potential in laboratory measurement is different from that occurring in stellar plasmas thus the quantity of interest in astrophysics is the so-called ""bare nucleus cross section"". This quantity can only be extrapolated in direct measurements. These are the reasons that led to a considerable growth on interest in indirect measurement techniques and in particular the Trojan Horse Method (THM) [2,3]. Results concerning the bare nucleus cross sections measurements will be shown in several cases of astrophysical interest. In those cases the screening potential evaluated by means of the THM will be compared with the adiabatic limit and results arising from extrapolation in direct measurements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A ventilation radiator is a combined ventilation and heat emission unit currently of interest due to its potential for increasing energy efficiency in exhaust ventilated buildings with warm water heating. This paper presents results of performance tests of several ventilation radiator models conducted under controlled laboratory conditions.   The purpose of the study was to validate results achieved by Computational Fluid Dynamics (CFD) in an earlier study and indentify possible improvements in the performance of such systems. The main focus was on heat transfer from internal convection fins, but comfort and health aspects related to ventilation rates and air temperatures were also considered.   The general results from the CFD simulations were confirmed; the heat output of ventilation radiators may be improved by at least 20 % without sacrificing ventilation efficiency or thermal comfort.   Improved thermal efficiency of ventilation radiators allows a lower supply water temperature and energy savings both for heating up and distribution of warm water in heat pumps or district heating systems. A secondary benefit is that a high ventilation rate can be maintained all year around without risk for cold draught.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The identification of appropriate laboratory measures to confirm clinical hypotheses is important in routine paracoccidioidomycosis medical care. The clinical records and laboratory reports of 401 paracoccidioidomycosis patients attended at the Tropical Diseases Area, Faculdade de Medicina de Botucatu, from 1974 to 2008 were reviewed. Direct mycological (DM), cell block (CB), histopathological (HP), and double immunodiffusion (DID) tests were evaluated before treatment. Typical Paracoccidioides brasiliensis yeast forms were observed in clinical specimens of 86% of the patients, but 14% were detected only by serological test. DM of 51 different tissue specimens produced 74.5% sensitivity, and 62.5% sensitivity was observed in 112 sputum samples. CB in 483 sputum samples generated 55.3% sensitivity. HP performed in 239 samples from different tissues revealed 96.7% sensitivity. Serology carried out in 351 patients and 200 healthy controls provided 90.0% sensitivity, 100.0% specificity, 100.0% positive predictive value, 85.1% negative predictive value and 93.6% accuracy. Comparisons of laboratory measurements performed in the same patient showed that sensitivity decreases from HP to DID to CB and DM, with the last two assays providing similar sensitivities. This study demonstrated that P. brasiliensis identification by HP, CB, and/or DM associated with DID is sufficient to establish the laboratorial diagnosis of paracoccidioidomycosis in practically all cases. (C) 2011 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper analyses the static and dynamic behavior of the railroad track model in laboratory. Measurements of stresses and strains on a large-scale railroad track apparatus were studied. The model includes: compacted soil, representing the final layers of platform, ballast layer, and ties (steel, wooden, and pre-stressed concrete). The soil and soil ballast interface were instrumented with pneumatic stress gauge. Settlement measurement device were positioned at the same levels as the load cells. Loads were applied by hydraulic actuators, statically and dynamically. After the prescribed number of load cycles, in pre-determined intervals, stresses and strains were measured. Observations indicate that stress and strain distributions, transmitted by wooden or steel ties, behave similarly. A more favorable behavior was observed with pre-stressed concrete mono block ties. Non-linear response was observed after a threshold numbers of cycles were surpassed, showing that the strain modulus increases with the numbers of cycles. © 2009 IOS Press.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Calculated indexes from laboratory measurements and the determination of plasma markers are commonly used in cardiovascular risk assessment. Objective: To use triglycerides/high-density lipoprotein cholesterol (HDL-C) ratio, estimate of low-density lipoprotein (LDL) particle size and high sensitive C-reactive protein (hs-CRP) levels to the clinical and laboratorial assessment of coronary risk among patients with coronary disease. Material and methods: Sixty patients were chosen accordingly, 36 female (F) (65 ± 9 years of age) and 24 male (M) (55 ± 10 years of age) diagnosed with stable ischemic cardiopathy at Ana Neri Hospital, Salvador, Bahia, Brazil. The investigation was carried out at the Clinical Biochemistry Laboratory of the College of Pharmacy at Federal University of Bahia (UFBA). Blood samples were collected after a 12-hour fast to determine hs-CRP, lipid profile and risk indicators. All data were assessed through Syncron LX®20 Beckman Coulter. The inferential analysis results were considered significant when p ≤ 5%. Data analysis was carried out with GraphPad Prism® (4.03 version) software. Results: Data analysis showed a positive correlation between hs-CRP and triglycerides/HDL-C ratio only among women (r = 0.4; p = 0.0442), n = 36. The analysis of other parameters did not show any significance. Conclusion: The triglycerides/HDL-C ratio and hs-CRP may be used as indicators of increase in cardiovascular risk among women with coronary artery disease (CAD).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Guarani aquifer system (GAS) represents one of the biggest aquifers in the world and is the most relevant groundwater resource in South America. For the first time, by combining field and laboratory measurements, a high-resolution aquifer analog model of fluvial-aeolian sediments of the GAS in São Paulo State (Brazil) is constructed. Three parallel sections of frontal outcrops, 28 m × 5.8 m, and two parallel sections of lateral outcrops, 7 m × 5.8 m, are recorded during open-pit mining of sandy sediments and describe in detail the three-dimensional distribution of the local lithofacies and hydrofacies. Variations of hydraulic conductivity, K, and porosity, n, are resolved on the centimeter scale, and the most permeable units of the fluvial-aeolian facies association are identified. The constructed aquifer analog model shows moderate hydraulic heterogeneity and a mean K value of 1.36 × 10-4 m/s, which is greater than the reported range of K values for the entire GAS in São Paulo State. The results suggest that the examined sedimentary unit constitutes a relevant portion of the GAS in São Paulo State in the context of groundwater extraction and pollution. Moreover, the constructed aquifer analog is considered an ideal basis for future numerical model experiments, aiming at in-depth understanding of the groundwater flow and contaminant transport patterns at this GAS portion or at comparable fluvial-aeolian facies associations. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foram realizadas medidas em laboratório da condutividade elétrica complexa de 28 amostras de testemunhos de sondagem de três furos da área MM1-Alvo 1, Distrito dos Carajás, com o objetivo de auxiliar na interpretação de dados geofísicos de campo, obtidos com os métodos polarização induzida/resistividade e eletromagnético/AFMAG, aplicados na área. As medidas foram tomadas no intervalo de frequências de 10-3Hz a 104Hz, medindo-se a amplitude e a fase da condutância. O método empregado foi o de medida direta de impedância, utilizando-se um osciloscópio com memória, um gerador de sinais e dois pré-amplificadores diferenciais com alta impedância de entrada. O sistema de eletrodos escolhido para realizar as medidas foi o de 2 eletrodos de platina-platinizada em virtude de sua resposta de frequência ser plana no intervalo utilizado. Todas as medidas foram realizadas à temperatura constante de 24°C ± 1°C. Para interpretar as medidas de condutividade foi realizado estudo petrográfico das amostras, utilizando-se lâminas delgadas, seções polidas e difração de Raios-X. Foi determinado o teor de cobre, sob a forma de sulfeto, nas amostras utilizando-se o método de absorção atômica. Os resultados petrográficos permitiram classificar as amostras em cinco grupos distintos: granito, biotita-xisto, anfibolito, anfibólio-xisto e quartzito ferruginoso-formação ferrífera. O teor de cobre foi variável nos cinco grupos, havendo teores desde 50ppm até 6000ppm. Nas medidas de condutividade observou-se que, dentre os cinco grupos, as amostras da formação ferrífera apresentaram as maiores variações com a frequência. As amostras de granito tiveram espectro mais plano que as dos xistos e anfibolito. A conclusão a que se chegou é que as anomalias eletromagnéticas e de polarização induzida/resistividade observadas no campo próximo aos três furos (F1, F2, F3) são devidas principalmgnte a formação ferrífera magnetitica, a secundariamente à mineralização de baixo teor de calcopirita associada.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A análise da estabilidade mecânica de um poço pode ser feita a partir do cálculo de parâmetros elásticos da formação utilizando a densidade do meio e as velocidades de propagação das ondas compressional e cisalhante na formação rochosa, os quais podem ser obtidos de perfis geofísicos do poço. Em formações sedimentares pouco consolidadas as ferramentas de perfilagem sônica convencionais (monopolares) não conseguem registrar com acuidade a velocidade da onda cisalhante pois a primeira chegada dessa onda é camuflada pela chegada de outras ondas que podem ser mais rápidas que a onda cisalhante num poço perfurado neste tipo de formação. Medidas das velocidades sônicas são feitas em laboratório em amostras da formação, sob condições semelhantes às condições in situ, servindo como ajuste das velocidades registradas no poço pela ferramenta de perfilagem sônica. Para a análise de estabilidade da formação, perfis auxiliares são necessários como o perfil de porosidade, saturação de fluidos e perfis de composição mineralógica da formação rochosa. Exige-se ainda dados de testes de avaliação da formação e de condições do reservatório, mas que são comuns em poços de petróleo, como o teste de formação e os testes de pressurização do poço, tais como o teste de micro-fraturamento hidráulico ou o teste de absorção. A avaliação das tensões principais efetivas que atuam distante do poço, e que não são afetadas pela sua presença, é feita através da associação de um modelo de deformação elástica apropriado e o resultado do teste de pressurização disponível para o poço em estudo. Utilizando resultados clássicos da teoria da elasticidade geral pode-se calcular o campo de tensões modificado na vizinhança da parede do poço devido ao efeito da própria presença do poço ali perfurado e da diferença de pressão existente entre o interior do poço e a formação rochosa. A determinação das propriedades mecânicas da formação a partir das velocidades sônicas e a avaliação do campo de tensões assumindo um modelo elástico de deformação, supõem o meio rochoso no qual as ondas se propagam como elástico, homogêneo e isotrópico. Esta suposição representa a principal aproximação assumida pela metodologia descrita neste trabalho. De posse das propriedades mecânicas da formação e do campo de tensões que age na vizinhança do poço resta definir o critério segundo o qual a rocha sofre instabilidade mecânica quando submetida aquele campo de tensões. Isto permite determinar se, nas condições avaliadas do poço e da formação, haverá quebra da parede do poço por excesso de tensão e, se houver, qual a sua extensão. Assim o problema é como analisar o comportamento mecânico de um poço em uma formação pouco consolidada a partir de perfis geofísicos os quais podem ter problemas no registro das propriedades físicas do meio em formações deste tipo. A metodologia proposta é aplicada a dois intervalos de profundidade pertencentes a dois poços onde arenitos e folhelhos se intercalam e nos quais todos os dados necessários estão disponíveis. Os resultados obtidos mostram que, exceto quando outros mecanismos de quebra da parede do poço agem na formação, a metodologia proposta consegue com sucesso detectar zonas de ocorrência de instabilidade mecânica do poço provocadas por um campo de tensões que excede a resistência mecânica da formação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents an investigation of the ductile tearing properties for a girth weld made of an API 5L X80 pipeline steel using experimentally measured crack growth resistance curves. Use of these materials is motivated by the increasing demand in the number of applications for manufacturing high strength pipes for the oil and gas industry including marine applications and steel catenary risers. Testing of the pipeline girth welds employed side-grooved, clamped SE(T) specimens and shallow crack bend SE(B) specimens with a weld centerline notch to determine the crack growth resistance curves based upon the unloading compliance (UC) method using the single specimen technique. Recently developed compliance functions and η-factors applicable for SE(T) and SE(B) fracture specimens with homogeneous material and overmatched welds are introduced to determine crack growth resistance data from laboratory measurements of load-displacement records.