120 resultados para Intracardiac Electrogram
Resumo:
Caseous calcification of the mitral annulus is a rare form of mitral annular calcification, whose etiology is not completely understood and which can lead to an erroneous diagnosis of intracardiac tumor. The authors describe the cases of six patients, five of them female, mean age 74.8 +/- 6.4 years (65-81). Four patients presented with heart failure, two with atrial fibrillation and five with hypertension. Round, echogenic images, 18-26 mm in their largest diameter with a central echolucent area, were identified by transthoracic echocardiography on the lateral and posterior segments of the mitral annulus. Severe mitral regurgitation was also found in four patients. Only three patients with severe mitral regurgitation and heart failure were operated on, and one patient refused surgical treatment. A caseous mass, similar to toothpaste, was obtained from the mitral annulus zone during surgery.
Resumo:
INTRODUCTION: Peripheral embolism is frequently related to a cardiac source of embolism. Transesophageal echocardiography (TEE) is a useful tool for identifying such sources. OBJECTIVES: Our laboratory has gained wide experience in TEE, with a large number of exams performed to search for a cardiac source of embolism. We therefore thought it would be useful to present our experience in the last 12 years following the introduction of the technique. METHODS: This was a retrospective study of 1110 consecutive patients undergoing TEE to search for a cardiac source of embolism, after an embolic event and a transthoracic echocardiogram. RESULTS: The patients' mean age was 53 +/- 14 years, 52% male. There was peripheral embolism in 5% of cases and cerebral embolism in the remainder. The exam identified a potential embolic source in 35.6% of cases, the most frequent diagnoses being intracardiac shunt at the atrial level (9.5%), atrial septal aneurysm (ASA) (6.6%), intracardiac thrombi (6.4%) and atherosclerotic plaques in the thoracic aorta (9.6%). The presence of ASA was frequently associated with patent foramen ovale (27%), which was more frequent in younger patients. Overall, we identified a cardiac source of embolism more often in elderly patients, with a predominance of atherosclerotic plaques in the aorta. ETE was more frequently diagnostic in patients with peripheral embolism, but there were no differences in terms of etiology. CONCLUSIONS: TEE is very useful to search for cardiac sources of embolism, especially in younger patients, in whom causes potentially treatable surgically or percutaneously can be identified. In elderly patients, therapeutic strategy will probably not be changed by the findings (mostly thrombi and atherosclerotic plaques). The presence of ASA and embolic events makes it essential to perform a thorough search by TEE for intracardiac shunts, which are frequently associated.
Resumo:
Slowed atrial conduction may contribute to reentry circuits and vulnerability for atrial fibrillation (AF). The autonomic nervous system (ANS) has modulating effects on electrophysiological properties. However, complex interactions of the ANS with the arrhythmogenic substrate make it difficult to understand the mechanisms underlying induction and maintenance of AF. AIM: To determine the effect of acute ANS modulation in atrial activation times in patients (P) with paroxysmal AF (PAF). METHODS AND RESULTS: 16P (9 men; 59±14years) with PAF, who underwent electrophysiological study before AF ablation, and 15P (7 men; 58±11years) with atrioventricular nodal reentry tachycardia, without documentation or induction of AF (control group). Each group included 7P with arterial hypertension but without underlying structural heart disease. The study was performed while off drugs. Multipolar catheters were placed at the high right atrium (HRA), right atrial appendage (RAA), coronary sinus (CS) and His bundle area (His). At baseline and with HRA pacing (600ms, shortest propagated S2) we measured: i) intra-atrial conduction time (IACT, between RAA and atrial deflection in the distal His), ii) inter-atrial conduction time (interACT, between RAA and distal CS), iii) left atrial activation time (LAAT, between atrial deflection in the distal His and distal CS), iv) bipolar electrogram duration at four atrial sites (RAA, His, proximal and distal CS). In the PAF group, measurements were also determined during handgrip and carotid sinus massage (CSM), and after pharmacological blockade of the ANS (ANSB). AF was induced by HRA programmed stimulation in 56% (self-limited - 6; sustained - 3), 68.8% (self-limited - 6; sustained - 5), and 50% (self-limited - 5; sustained - 3) of the P, in basal, during ANS maneuvers, and after ANSB, respectively (p=NS). IACT, interACT and LAAT significantly lengthened during HRA pacing in both groups (600ms, S2). P with PAF have longer IACT (p<0.05), a higher increase in both IACT, interACT (p<0.01) and electrograms duration (p<0.05) with S2, and more fragmented activity, compared with the control group. Atrial conduction times and electrograms duration were not significantly changed during ANS stimulation. Nevertheless, ANS maneuvers increased heterogeneity of the local electrograms duration. Also, P with sustained AF showed longer interACT and LAAT during CSM. CONCLUSION: Atrial conduction times, electrograms duration and fractionated activity are increased in PAF, suggesting a role for conduction delays in the arrhythmogenic substrate. Acute vagal stimulation is associated with prolonged interACT and LAAT in P with inducible sustained AF and ANS modulation may influence the heterogeneity of atrial electrograms duration.
Resumo:
The autonomic nervous system and especially the intracardiac autonomic nervous system is involved in Chagas' disease. Ganglionitis and periganglionitis were noted in three groups ofpatients dying with Chagas'disease: 1) Those in heart failure; 2) Those dying a sudden, non violent death and; 3) Those dying as a consequence ofaccidents or homicide. Hearts in the threegroups also revealed myocarditis and scattered involvement of intramyocardial ganglion cells as well as lesions of myelinic and unmyelinic fibers ascribable to Chagas'disease. In mice with experimentally induced Chagas' disease weobserved more intensive neuronal lesions of the cardiac ganglia in the acute phase of infection. Perhaps neuronal loss has a role in the pathogenesis of Chagas cardiomyopathy. However based on our own experience and on other data from the literature we conclude that the loss of neurones is not the main factor responsible for the manifestations exhibited by chronic chagasic patients. On the other hand the neuronal lesions may have played a role in the sudden death ofone group of patients with Chagas'disease but is difficult to explain the group of patients who did not die sudderly but instead progressed to cardiac failure.
Resumo:
OBJECTIVE: To study electrophysiological characteristics that enable the identification and ablation of sites of chagasic tachycardia. METHODS: Thirty-one patients with chronic Chagas' heart disease and sustained ventricular tachycardia (SVT) underwent electrophysiological study to map and ablate that arrhythmia. Fifteen patients had hemodinamically stable SVT reproducible by programmed ventricular stimulation, 9 men and 6 women with ages ranging from 37 to 67 years and ejection fraction varying from 0.17 to 0.64. Endocardial mapping was performed during SVT in all patients. Radiofrequency (RF) current was applied to sites of presystolic activity of at least 30 ms. Entrainment was used to identify reentrant circuits. In both successful and unsuccessful sites of RF current application, electrogram and entrainment were analyzed. RESULTS: Entrainment was obtained during all mapped SVT. In 70.5% of the sites we observed concealed entrainment and ventricular tachycardia termination in the first 15 seconds of RF current application. In the unsuccessful sites, significantly earlier electrical activity was seen than in the successful ones. Concealed entrainment was significantly associated with ventricular tachycardia termination. Bystander areas were not observed. CONCLUSION: The reentrant mechanism was responsible for the genesis of all tachycardias. In 70.5% of the studied sites, the endocardial participation of the slow conducting zone of reentrant circuits was shown. Concealed entrainment was the main electrophysiological parameter associated with successful RF current application. There was no electrophysiological evidence of bystander regions in the mapped circuits of SVT.
Resumo:
Only rarely do myxomas originate from the mitral valve. This is the report of a 49-year-old woman presenting with congestive heart failure. The diagnosis of an intracardiac tumor involving the anterior cuspid of the mitral valve was made by transesophageal echocardiography. The patient underwent surgery for tumor resection and plasty of the valve was made with reconstruction and preservation of the valve. The diagnosis of myxoma was confirmed by histology. This is the 23rd case of myxoma of the mitral valve reported in the literature.
Resumo:
Background: Cardiac tumors are rare, mostly benign with high embolic potential. Objectives: To correlate the histological type of cardiac masses with their embolic potential, implantation site and long term follow up in patients undergoing surgery. Methods: Between January 1986 and December 2011, we retrospectively analyzed 185 consecutive patients who underwent excision of intracardiac mass (119 females, mean age 48±20 years). In 145 patients, the left atrium was the origin site. 72% were asymptomatic and prior embolization was often observed (19.8%). The diagnosis was established by echocardiography, magnetic resonance and histological examination. Results: Most tumors were located in the left side of the heart. Myxoma was the most common (72.6%), followed by fibromas (6.9%), thrombi (6.4%) and sarcomas (6.4%). Ranging from 0.6cm to 15cm (mean 4.6 ± 2.5cm) 37 (19.8%) patients had prior embolization, stroke 10.2%, coronary 4.8%, peripheral 4.3% 5.4% of hospital death, with a predominance of malignant tumors (40% p < 0.0001). The histological type was a predictor of mortality (rhabdomyomas and sarcomas p = 0.002) and embolic event (sarcoma, lipoma and fibroelastoma p = 0.006), but not recurrence. Tumor size, atrial fibrillation, cavity and valve impairment were not associated with the embolic event. During follow-up (mean 80±63 months), there were 2 deaths (1.1%) and two recurrences 1 and 11 years after the operation, to the same cavity. Conclusion: Most tumors were located in the left side of the heart. The histological type was predictor of death and preoperative embolic event, while the implantation site carries no relation with mortality or to embolic event.
Resumo:
Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.
Resumo:
Intracardiac organization indices such as atrial fibril- lation (AF) cycle length (AFCL) have been used to track the efficiency of stepwise catheter ablation (step-CA) of long-standing persistent AF (pers-AF), however, with lim- ited success. The timing between nearby bipolar intracar- diac electrograms (EGMs) reflects the spatial dynamics of wavelets during AF. The extent of synchronization between EGMs is an indirect measure of AF spatial organization. The synchronization between nearby EGMs during step- CA of pers-AF was evaluated using new indices based on the cross-correlation. The first one (spar(W)) quantifies the sparseness of the cross-correlation of local activation times. The second one (OI(W)) reflects the local concen- tration around the largest peak of the cross-correlation. By computing their relative evolution during step-CA until AF termination (AF-term), we found that OI(W) appeared su- perior to AFCL and spar(W) to track the effect of step-CA "en route" to AF-term.
Resumo:
We sought to provide a contemporary picture of the presentation, etiology, and outcome of infective endocarditis (IE) in a large patient cohort from multiple locations worldwide. Prospective cohort study of 2781 adults with definite IE who were admitted to 58 hospitals in 25 countries from June 1, 2000, through September 1, 2005. The median age of the cohort was 57.9 (interquartile range, 43.2-71.8) years, and 72.1% had native valve IE. Most patients (77.0%) presented early in the disease (<30 days) with few of the classic clinical hallmarks of IE. Recent health care exposure was found in one-quarter of patients. Staphylococcus aureus was the most common pathogen (31.2%). The mitral (41.1%) and aortic (37.6%) valves were infected most commonly. The following complications were common: stroke (16.9%), embolization other than stroke (22.6%), heart failure (32.3%), and intracardiac abscess (14.4%). Surgical therapy was common (48.2%), and in-hospital mortality remained high (17.7%). Prosthetic valve involvement (odds ratio, 1.47; 95% confidence interval, 1.13-1.90), increasing age (1.30; 1.17-1.46 per 10-year interval), pulmonary edema (1.79; 1.39-2.30), S aureus infection (1.54; 1.14-2.08), coagulase-negative staphylococcal infection (1.50; 1.07-2.10), mitral valve vegetation (1.34; 1.06-1.68), and paravalvular complications (2.25; 1.64-3.09) were associated with an increased risk of in-hospital death, whereas viridans streptococcal infection (0.52; 0.33-0.81) and surgery (0.61; 0.44-0.83) were associated with a decreased risk. In the early 21st century, IE is more often an acute disease, characterized by a high rate of S aureus infection. Mortality remains relatively high.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.
Resumo:
Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
Resumo:
The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.
Resumo:
To date, myxoma on a mechanical valve annulus has not been reported. The case is reported of a 74-year-old woman who was admitted to hospital following the identification of an intracardiac tumor mass. Six years previously, the patient had received a mechanical valve implanted in the mitral position. Transesophageal echocardiography revealed a mobile hypoechogenic tumorous mass attached to the anterior annulus of the prosthesis. The tumor was successfully treated by surgical excision, and a diagnosis of myxoma was confirmed both clinically and pathologically.