997 resultados para Immediate functional loading


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate 16 patients of both sexes with lower overdenture and upper complete dentures, by analysing the resonance frequency of the initial and late stability of implants used to retain the overdenture under immediate loading. Background: Oral rehabilitation treatment with complete dentures using implants has been increasingly more common among the specialists in the oral rehabilitation area. This is an alternative for obtaining retention and stability in treatments involving conventional complete dentures, where two implants are enough to retain the overdenture satisfactorily. Materials and methods: The Osstell (TM) Mentor device was used for the analysis in the initial period (primary stability), 3 and 15 months after the installation of the lower overdenture (secondary stability). The statistical analysis was performed with the repeated measures model (p < 0.01). Results: The implant stability quotients were observed to increase after 15 months of the rehabilitating treatment. Conclusion: The use of overdentures over two lower implants should become the treatment of choice for individuals who have a fully edentulous mandible.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate whether or not preparation of the implant site with osteotomes instead of drilling may improve peri-implant bone density and/or osseointegration, and whether or not this further improves the predictability of immediate loading of SLA implants. MATERIAL AND METHODS: The second, third, and fourth premolars were extracted in both sides of the mandible in six dogs, and after at least 3 months four SLA implants were inserted into each side of the jaw. In three animals, the implant sites were prepared by means of osteotomes, while standard stepwise drilling was used in the remaining animals. In each side of the jaw, two non-adjacent implants were restored with single crowns 4 days after installation, while the remaining two implants were left without crowns to serve as non-loaded controls. After 2, 4, or 12 weeks of loading, specimens including the implants and surrounding tissues were obtained and processed for histologic analysis of undecalcified sections. RESULTS: All implants placed with osteotomes were lost (five before delivery of the crowns and the rest during the first week after loading). None of the conventionally inserted implants, however, was lost, and histomorphometrical analysis revealed similar soft- and hard peri-implant tissue characteristics at immediately loaded and non-loaded implants at all observation times. Average bone-to-implant contact was 59-72% at immediately loaded implants vs. 60-63% at non-loaded ones. CONCLUSION: Preparation of the implant site by means of osteotomes had a deleterious effect on osseointegration, while immediate loading of single, free-standing, SLA implants following a conventional surgical protocol did not jeopardize their osseointegration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: Immediate and early loading of dental implants can simplify treatment and increase overall patient satisfaction. The purpose of this 3-year prospective randomized-controlled multicenter study was to assess the differences in survival rates and bone level changes between immediately and early-loaded implants with a new chemically modified surface (SLActive). This investigation shows interim results obtained after 5 months. MATERIAL AND METHODS: Patients > or =18 years of age missing at least one tooth in the posterior maxilla or mandible were enrolled in the study. Following implant placement, patients received a temporary restoration either on the day of surgery (immediate loading) or 28-34 days after surgery (early loading); restorations consisted of single crowns or two to four unit fixed dental prostheses. Permanent restorations were placed 20-23 weeks following surgery. The primary efficacy variable was change in bone level (assessed by standardized radiographs) from baseline to 5 months; secondary variables included implant survival and success rates. RESULTS: A total of 266 patients were enrolled (118 males and 148 females), and a total of 383 implants were placed (197 and 186 in the immediate and early loading groups, respectively). Mean patient age was 46.3+/-12.8 years. After 5 months, implant survival rates were 98% in the immediate group and 97% in the early group. Mean bone level change from baseline was 0.81+/-0.89 mm in the immediate group and 0.56+/-0.73 mm in the early group (P<0.05). Statistical analysis revealed a significant center effect (P<0.0001) and a significant treatment x center interaction (P=0.008). CONCLUSIONS: The results suggested that Straumann implants with an SLActive can be used predictably in time-critical (early or immediate) loading treatment protocols when appropriate patient selection criteria are observed. The mean bone level changes observed from baseline to 5 months (0.56 and 0.81 mm) corresponded to physiological observations from other studies, i.e., were not clinically significant. The presence of a significant center effect and treatment x center interaction indicated that the differences in bone level changes between the two groups were center dependent.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Compensatory ventilatory responses to increased inspiratory loading are essential for adequate breathing regulation in a number of pulmonary diseases; however, the human brain sites mediating such responses are unknown. Midsagittal and axial images were acquired in 11 healthy volunteers during unloaded and loaded (30 cmH2O; 1 cmH2O = 98 Pa) inspiratory breathing, by using functional magnetic resonance imaging (fMRI) strategies (1.5-tesla MR; repetition time, 72 msec; echo time, 45 msec; flip angle, 30 degrees; field of view, 26 cm; slice thickness, 5 mm; number of excitations, 1; matrix, 128 x 256). Digital image subtractions and region of interest analyses revealed significantly increased fMRI signal intensity in discrete areas of the ventral and dorsal pons, interpeduncular nucleus, basal forebrain, putamen, and cerebellar regions. Upon load withdrawal, certain regions displayed a rapid fMRI signal off-transient, while in others, a slower fMRI signal decay emerged. Sustained loading elicited slow decreases in fMRI signal across activated regions, while second application of an identical load resulted in smaller signal increases compared to initial signal responses (P < 0.001). A moderate inspiratory load is associated with consistent regional activation of discrete brain locations; certain of these regions have been implicated in mediation of loaded breathing in animal models. We speculate that temporal changes in fMRI signal may indicate respiratory after-discharge and/or habituation phenomena.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cellular mechanisms coupling mechanical loading with bone remodeling remain unclear. In the CNS, the excitatory amino acid glutamate (Glu) serves as a potent neurotransmitter exerting its effects via various membrane Glu receptors (GluR). Nerves containing Glu exist close to bone cells expressing functional GluRs. Demonstration of a mechanically sensitive glutamate/aspartate transporter protein and the ability of glutamate to stimulate bone resorption in vitro suggest a role for glutamate linking mechanical load and bone remodeling. We used immunohistochemical techniques to identify the expression of N-methyl-D-aspartate acid (NMDA) and non-NMDA (AMPA or kainate) ionotropic GluR subunits on bone cells in vivo. In bone sections from young adult rats, osteoclasts expressed numerous GluR subunits including AMPA (GluR2/3 and GluR4), kainic acid (GluR567) and NMDA (NMDAR2A, NMDAR2B and NMDAR2C) receptor subtypes. Bone lining cells demonstrated immunoexpression for NMDAR2A, NMDAR2B, NMDAR2C, GluR567, GluR23, GuR2 and GluR4 subunits. Immunoexpression was not evident on osteocytes, chondrocytes or vascular channels. To investigate the effects of mechanical loading on GluR expression, we used a Materials Testing System (MTS) to apply 10 N sinusoidal axial compressive loads percutaneously to the right limbs (radius/ulna, tibia/fibula) of rats. Each limb underwent 300-load cycles/day (cycle rate, 1 Hz) for 4 consecutive days. Contralateral, non-loaded limbs served as controls. Mechanically loaded limbs revealed a load-induced loss of immunoexpression for GluR2/3, GluR4, GluR567 and NMDAR2A on osteoclasts and NMDAR2A, NMDAR2B, GluR2/3 and GluR4 on bone lining cells. Both neonatal rabbit and rat osteoclasts were cultured on bone slices to investigate the effect of the NMDA receptor antagonist, MK801, and the AMPA/kainic acid receptor antagonist, NBQX, on osteoclast resorptive activity in vitro. The inhibition of resorptive function seen suggested that both NMDAR and kainic acid receptor function are required for normal osteoclast function. While the exact role of ionotropic GluRs in skeletal tissue remains unclear, the modulation of GluR subunit expression by mechanical loading lends further support for participation of Glu as a mechanical loading effector. These ionotropic receptors appear to be functionally relevant to normal osteoclast resorptive activity. (C) 2005 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Magnesium (Mg) use has the potential to promote bronchodilatation and to improve lung function in obstructive diseases. IV administration of Mg during exacerbations of chronic obstructive pulmonary disease (COPD) has led to improved peak flow. This study aimed to investigate the effects of acute IV Mg loading on respiratory parameters of stable COPD patients. Material/Methods: This was a randomized, double-blind, placebo-controlled crossover study. Twenty-two male COPD patients (64 +/- 6 years old, FEV1: 49 +/- 20%) received an IV infusion of 2 g of magnesium sulfate or placebo on two distinct occasions. Spirometry and mouth maximal respiratory pressures were obtained before and 45 minutes after the infusions. Results: Mg use led to significant changes in functional respiratory capacity (-0.48 1,95% CI: -0.96, -0.01), inspiratory capacity (0.21 1,95% CI: 0.04, 0.37). The treatment was also associated with a marginally significant decrease in residual volume (-0.47 1,95% CI: -0.96, 0.02, p=0.06). Conclusions: Acute IV Mg loading in stable COPD patients was associated with a reduction in lung hyperinflation and improvement of respiratory muscle strength. The clinical potential for chronic magnesium supplementation in COPD deserves further investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Mobilization with movement (MWM) has been shown to reduce pain, increase range of motion (ROM) and physical function in a range of different musculoskeletal disorders. Despite this evidence, there is a lack of studies evaluating the effects of MWM for hip osteoarthritis (OA). Objectives To determine the immediate effects of MWM on pain, ROM and functional performance in patients with hip OA. Design Randomized controlled trial with immediate follow-up. Method Forty consenting patients (mean age 78 ± 6 years; 54% female) satisfied the eligibility criteria. All participants completed the study. Two forms of MWM techniques (n = 20) or a simulated MWM (sham) (n = 20) were applied. Primary outcomes: pain recorded by numerical rating scale (NRS). Secondary outcomes: hip flexion and internal rotation ROM, and physical performance (timed up and go, sit to stand, and 40 m self placed walk test) were assessed before and after the intervention. Results For the MWM group, pain decreased by 2 points on the NRS, hip flexion increased by 12.2°, internal rotation by 4.4°, and functional tests were also improved with clinically relevant effects following the MWM. There were no significant changes in the sham group for any outcome variable. Conclusions Pain, hip flexion ROM and physical performance immediately improved after the application of MWM in elderly patients suffering hip OA. The observed immediate changes were of clinical relevance. Future studies are required to determine the long-term effects of this intervention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE - To analyze immediate and late results of percutaneous mitral valvotomy (PMV) in patients <= 18 year. METHODS - Between August '87 and July '97, 48 procedures were performed on 40 patients. The mean age was 15.6 years; 68.7% were females four of whom were pregnant. RESULTS - Success was obtained in 91.7% of the procedures. Immediate complications were severe mitral regurgitation (6.3%) and cardiac tamponade (2.0%). Late follow-up was obtained in 88.8% of the patients (mean value=43.2±33.9 months). NYHA functional class (FC) I or II was observed in 96.2% of the patients and restenosis developed in five patients, at a mean follow-up of 29.7±11.9 months. Three patients presented with severe mitral insufficiency and underwent surgery. Two patients died. CONCLUSION - PMV represents a valid therapeutic option in young patients. In these patients, maybe because of subclinical rheumatic activity, restenosis may have a higher incidence and occur at an earlier stage than in others persons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this work was the follow-up and evaluation of valve replacement in children under 12 years of age. METHODS: Forty-four children less than 12 years old were underwent valve replacement at INCOR-HCFMUSP between January 1986 and December 1992. Forty (91%) were rheumatic, 39 (88.7%) were in functional classes II or IV, 19 (43.2%) were operated upon on an emergency basis, and 6 (13.6%) had atrial fibrillation. Biological prostheses (BP) were employed in 26 patients (59.1%), and mechanical prostheses (MP) in 18 (40.9%). Mitral valves were replaced in 30 (68.7%), aortic valves in 8 (18.2%), a tricuspid valve in 1 (2.3%), and double (aortic and mitral) valves in 5 (11.4) of the patients. RESULTS: Hospital mortality was of 4.5% (2 cases). The mean follow-up period was 5.8 years. Re-operations occurred in 63.3% of the patients with BP and in 12.5% of those with MP (p=0.002). Infectious endocarditis was present in 26.3% of the BP, but in none of the cases of MP (p=0.049). Thrombosis occurred in 2 (12.5%) and hemorrhage in one (6.5%) of the patients with a MP. Delayed mortality occurred in 5 (11.9%) of the patients over a mean period of 2.6 years; four had had BP and one had a MP (NS). Actuarial survival and re-operation-free curves after 10 years were respectively, 82.5±7.7 (SD)% and 20.6±15.9%. CONCLUSION: Patients with MP required fewer re-operation, had less infectious endocarditis and lower late mortality rates compared with patients with bioprostheses. The former, therefore, appear to be the best valve replacement for pediatric patients.