960 resultados para IIR filter
Resumo:
This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.
Resumo:
Several suction–water-content (s-w) calibrations for the filter paper method (FPM) used for soil-suction measurement have been published. Most of the calibrations involve a bilinear function (i.e., two different equations) with an inflection point occurring at 60 kPafilter paper Whatman No. 42 (W42) is presented and discussed. The approach is applied herein to data obtained from three establish bilinear calibrations (six equations) for W42 filter paper to determine the two fitting parameters of the continuous function. An experimental evaluation of the new calibration show that the suctions estimated by the contact FPM test using the proposed function compare well with suctions measured by other laboratory
techniques for two different soils for the suction range of 50 kPa
Resumo:
The freshwater sponges Trochospongilla variabilis Bonetto & Ezcurra de Drago (1973), Radiospongilla crateriformis (Potts, 1882), Spongilla cenota Penney & Racek (1968) and Corvoheteromeyenia heterosclera (Ezcurra de Drago, 1974) compose with the sphaerid bivalve Eupera cubensis (Prime, 1865) and several Phylactolaemata bryozoans a benthic filter feeding community living in seasonal lentic and lotic habitats with high Particulate Organic Carbon (POC), low conductivity and acid pH within the Costa Rica Dry Forest biome. The sponge specimens gathered led to the re-description of the four species.
Resumo:
Various methodologies in economic literature have been used to analyse the international hydrocarbon retail sector. Nevertheless at a Spanish level these studies are much more recent and most conclude that generally there is no effective competition present in this market, regardless of the approach used. In this paper, in order to analyse the price levels in the Spanish petrol market, our starting hypothesis is that in uncompetitive markets the prices are higher and the standard deviation is lower. We use weekly retail petrol price data from the ten biggest Spanish cities, and apply Markov chains to fill the missing values for petrol 95 and diesel, and we also employ a variance filter. We conclude that this market demonstrates reduced price dispersion, regardless of brand or city.
Resumo:
This study evaluates whether blood collected on filter paper kept at 4 degrees C and tested at different intervals of time (1, 7, 15, 30 and 60 days after collection) would present similar results when compared to the serum samples and whether the type of filter paper influences the results. Eluates from filter paper samples were tested for Trypanosoma cruzi antibodies using indirect immunofluorescence antibody test (IFAT), indirect haemagglutination (IHA) and enzyme-linked immunosorbent assay (ELISA) as reference, the antibody titer in sera. Analysis of data showed that results obtained with IFAT, IHA (cut off point = 1:40) and ELISA in sera had similar sensitivity and good concordance among reactions. The use of a multiple linear regression model indicated that titer fall in eluates occurs up to the 7th day after the collection, and it is more marked for samples with lower antibodies titers. However, no significant differences were observed by IFAT, IHA (cut off point = 1:20) and ELISA in the proportion of positive reactions between sera and eluates. The results also showed that Melitta, Klabin or Whatman (reference) filter papers could be indicated for surveys, since they have shown similar capacity of maintenance of anti-T. cruzi immunoglobulins.
Resumo:
The collection of dried blood spots (DBS) on filter paper provides a powerful approach for the development of large-scale, population-based screening programs. DBS methods are particularly valuable in developing countries and isolated rural regions where resources are limited. Large numbers of field specimens can be economically collected and shipped to centralized reference laboratories for genetic and (or) serological analysis. Alternatively, the dried blood can be stored and used as an archival resource to rapidly establish the frequency and distribution of newly recognized mutations, confirm patient identity or track the origins and emergence of newly identified pathogens. In this report, we describe how PCR-based technologies are beginning to interface with international screening programmes for the diagnosis and genetic characterization of human immunodeficiency virus type 1 (HIV-1). In particular, we review recent progress using DBS specimens to resolve the HIV-1 infection status of neonates, monitor the genetic evolution of HIV-1 during early infancy and establish a sentinel surveillance system for the systematic monitoring of HIV-1 genetic variation in Asia.
Resumo:
Als darrers anys la necessitat de connectar-se a internet des de qualsevol lloc s’ha incrementat exponencialment sobretot de manera inalàmbrica. Degut al finit espectre radioelèctric es tendeix a aprofitar totes les franges freqüencials d’aquest convivint diferents sistemes en franges properes podent induir-se interferències mútuament. Per evitar aquestes interferències es requereix de filtres a tots els dispositius els quals aïllin un sistema del adjacent. En aquest projecte es dóna una solució al cas concret de la convivència entre els sistemes Wi-Fi y WiMAX eliminant la banda Wi-Fi interferent en sistemes WiMAX. Aquesta solució consisteix en el disseny d’un filtre banda eliminada d’ordre 3 implementat mitjançant tecnologia BAW a partir de l’estructura y especificacions d’un filtre comercial. A més també es fa un petit estudi per veure si seria interessant una millora en els processos de fabricació del filtre per part del fabricant.
Resumo:
Zeta plus filter membranes (ZP60S) have been shown to be efficient for rotavirus concentration from wastewater and for the reduction of cytotoxicity for cell cultures. Recently a variability in both properties was observed. In view of the low costs and the high virus recovery rates obtained in the past, we re-evaluated the application of ZP60S filter membranes for virus concentration from environmental samples. Some factors that could interfere with the concentration strategy using ZP60S were also considered and assessed including the type of water to be filtered and the possible release of toxic substances from the membrane matrix during filtration.
Resumo:
PCR detection of Trypanosoma cruzi in Rhodnius prolixus using fresh tissue or fecal drops on filter paper showed comparable results: 38.7% infection rate using the fresh tissue sample and 37.9% by dried fecal drop.
Resumo:
Tant el medi transmissor com els equips d'enregistrament o reproducció de so introdueixen components de soroll d'alta freqüència als senyals. En aquest treball de final de carrera (TFC), s'ha dissenyat i implementat un sistema de filtrat d'àudio encaminat a filtrar aquestes components d'alta freqüència. Donat que l'oïda humana no pot percebre sons de més de 20 kHz, s'ha considerat aquest límit com a freqüència màxima a mantenir en la senyal.S'ha començat estudiant el senyal problema a través del seu espectre de freqüències simulat mitjançant la transformada discreta de Fourier (DFT, en anglès). Una vegada identificades les components d'alta freqüència a atenuar, s'han estudiat les diferents opcions de filtre passabaix.Inicialment, s'ha valorat la possibilitat del disseny de filtres analògics de Butterworth o Chebyshev, o de filtres digitals de tipus IIR (Infinite Impulse Response) basats en els primers. Tanmateix, malgrat assolir les especificacions en magnitud, mitjançant aquest filtres no s'obté una fase lineal en la banda de pas. Per això, s'ha realitzat un disseny de filtre digital tipus FIR (Finite Infinite Response) que compleix estrictament amb les especificacions i presenta una fase lineal en la banda de pas. S'ha simulat el comportament d'aquest filtre amb el senyal problema per tal d'assegurar el seu correcte funcionament.A continuació, s'ha implementat aquest últim disseny en llenguatge C i compilat per un microcontrolador de l'empresa Microchip. S'han realitzat proves de simulació mitjançant Stimulus del programa MPLAB. En definitiva, s'ha dissenyat un filtre passabaix de tipus FIR per acondicionar una senyal d'àudio que posteriorment s'ha implementat en un microcontrolador de Microchip.
Resumo:
The epithelial Na(+) channel (ENaC), located in the apical membrane of tight epithelia, allows vectorial Na(+) absorption. The amiloride-sensitive ENaC is highly selective for Na(+) and Li(+) ions. There is growing evidence that the short stretch of amino acid residues (preM2) preceding the putative second transmembrane domain M2 forms the outer channel pore with the amiloride binding site and the narrow ion-selective region of the pore. We have shown previously that mutations of the alphaS589 residue in the preM2 segment change the ion selectivity, making the channel permeant to K(+) ions. To understand the molecular basis of this important change in ionic selectivity, we have substituted alphaS589 with amino acids of different sizes and physicochemical properties. Here, we show that the molecular cutoff of the channel pore for inorganic and organic cations increases with the size of the amino acid residue at position alpha589, indicating that alphaS589 mutations enlarge the pore at the selectivity filter. Mutants with an increased permeability to large cations show a decrease in the ENaC unitary conductance of small cations such as Na(+) and Li(+). These findings demonstrate the critical role of the pore size at the alphaS589 residue for the selectivity properties of ENaC. Our data are consistent with the main chain carbonyl oxygens of the alphaS589 residues lining the channel pore at the selectivity filter with their side chain pointing away from the pore lumen. We propose that the alphaS589 side chain is oriented toward the subunit-subunit interface and that substitution of alphaS589 by larger residues increases the pore diameter by adding extra volume at the subunit-subunit interface.
Resumo:
Because of the various matrices available for forensic investigations, the development of versatile analytical approaches allowing the simultaneous determination of drugs is challenging. The aim of this work was to assess a liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform allowing the rapid quantification of colchicine in body fluids and tissues collected in the context of a fatal overdose. For this purpose, filter paper was used as a sampling support and was associated with an automated 96-well plate extraction performed by the LC autosampler itself. The developed method features a 7-min total run time including automated filter paper extraction (2 min) and chromatographic separation (5 min). The sample preparation was reduced to a minimum regardless of the matrix analyzed. This platform was fully validated for dried blood spots (DBS) in the toxic concentration range of colchicine. The DBS calibration curve was applied successfully to quantification in all other matrices (body fluids and tissues) except for bile, where an excessive matrix effect was found. The distribution of colchicine for a fatal overdose case was reported as follows: peripheral blood, 29 ng/ml; urine, 94 ng/ml; vitreous humour and cerebrospinal fluid, < 5 ng/ml; pericardial fluid, 14 ng/ml; brain, < 5 pg/mg; heart, 121 pg/mg; kidney, 245 pg/mg; and liver, 143 pg/mg. Although filter paper is usually employed for DBS, we report here the extension of this alternative sampling support to the analysis of other body fluids and tissues. The developed platform represents a rapid and versatile approach for drug determination in multiple forensic media.
Resumo:
Many empirical studies of business cycles have followed the practise ofapplying the Hodrick-Prescott filter for cross-country comparisons. Thestandard procedure is to set the weight \lambda, which determines the'smoothness' of the trend equal to 1600. We show that if this value isused for against common wisdom about business cycles. As an example, weshow that the long recession occurred inSpain between 1975 and 1985 goesunnotoced by the HP filter. We propose a method for adjusting \lambda byreinterpreting the HP-filter as the solution to a constrained minimizationproblem. We argue that the common practice of fixing \lambda across countriesamounts to chankging the constraints on trend variability across countries.Our proposed method is easy to apply, retains all the virtues of thestandard HP-filter and when applied to Spanish data the results are inthe line with economic historian's view. Applying the method to a numberof OECD countries we find that, with the exception of Spain, Italy andJapan, the standard choice of \lambda=1600 is sensible.
Resumo:
This note describes how the Kalman filter can be modified to allow for thevector of observables to be a function of lagged variables without increasing the dimensionof the state vector in the filter. This is useful in applications where it is desirable to keepthe dimension of the state vector low. The modified filter and accompanying code (whichnests the standard filter) can be used to compute (i) the steady state Kalman filter (ii) thelog likelihood of a parameterized state space model conditional on a history of observables(iii) a smoothed estimate of latent state variables and (iv) a draw from the distribution oflatent states conditional on a history of observables.