953 resultados para Hemodynamics, Intermittent Positive-Pressure Ventilation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a reflector insert, the original HM-3 lithotripter field at 20 kV was altered significantly with the peak positive pressure (p(+)) in the focal plane increased from 49 to 87 MPa while the -6 dB focal width decreased concomitantly from 11 to 4 mm. Using the original reflector, p(+) of 33 MPa with a -6 dB focal width of 18 mm were measured in a pre-focal plane 15-mm proximal to the lithotripter focus. However, the acoustic pulse energy delivered to a 28-mm diameter area around the lithotripter axis was comparable ( approximately 120 mJ). For all three exposure conditions, similar stone comminution ( approximately 70%) was produced in a mesh holder of 15 mm after 250 shocks. In contrast, stone comminution produced by the modified reflector either in a 15-mm finger cot (45%) or in a 30-mm membrane holder (14%) was significantly reduced from the corresponding values (56% and 26%) produced by the original reflector (no statistically significant differences were observed between the focal and pre-focal planes). These observations suggest that a low-pressure/broad focal width lithotripter field will produce better stone comminution than its counterpart with high-pressure/narrow focal width under clinically relevant in vitro comminution conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cette thèse présente une série d'études qui visent la compréhension de la structure électronique de complexes de métaux de transition en employant diverses méthodes de spectroscopie. L'information sur la structure électronique aide à comprendre et développer des nouveaux matériaux, des nouvelles voies de synthèses, ainsi que des nouveaux modèles théoriques. Habituellement, afin d'explorer la structure électronique d'un système qui comporte en son centre un métal de transition, l'information fournie par les spectres d'un seul composé n'est pas suffisante. On étudie une série de composés similaires, qui ont le même métal de transition à un degré d'oxydation donné, ainsi que des ligands qui forment des liaisons de différentes forces et caractéristiques avec le métal. Cependant, ces changements, bien qu'on les désire de faible impact, créent une grande perturbation de la structure électronique visée par les études. Afin d'étudier en profondeur une seule structure électronique, nous employons une stratégie d'analyse moins perturbante. Nous appliquons une pression hydrostatique sur les complexes de métaux de transition. Cette pression perturbe le système suffisamment pour nous livrer davantage d'informations sur la structure électronique, sans la « dénaturer ». Afin d'étudier précisément ces systèmes perturbés, la technique d'application de pression est conjuguée, dans la littérature, aux diverses techniques de spectroscopie d'absorption UV-visible, de luminescence, ainsi que de diffusion Raman. Pour extraire un maximum d'informations de ces expériences, on emploie des techniques de calculs de structure électronique ainsi que de dynamique des noyaux. Dans cette thèse, on tente de mettre en lumière la structure électronique de composés de molybdène(IV), de platine(II) et palladium(II) à l'aide de la technique de pression couplée aux spectroscopies de luminescence et de diffusion Raman. Dans le chapitre 3, on observe un déplacement de la bande de luminescence de +12 cm-1/kbar entre la pression ambiante et 25 kbar pour le complexe trans-[MoOCl(CN-t-Bu)4]BPh4, dont le centre métallique molybdène(IV)est de configuration électronique 4d2. Il s'agit de la première variation positive observée pour un complexe de type métal-oxo. À des pressions plus élevées, la tendance s'inverse. Le maximum d'énergie de la bande de luminescence se déplace de -8 cm-1/kbar. Ce changement de variation présage d'une compétition interne entre les ligands situés sur les différents axes de l'octaèdre. À l'aide de calculs basés sur la théorie de la fonctionnelle de la densité, on propose un mécanisme pour expliquer ce phénomène. Au cours du chapitre 4, on étudie des complexes de palladium(II) et de platine(II) qui ont les mêmes ligands. Un de ces ligands est le 1,4,7-trithiacyclononane (ttcn). On constate qu'à basse pression le ligand est bidentate. Par contre, lorsque la pression augmente, on constate, par exemple à l'aide du complexe [Pt(ttcn)Cl2], qu'une interaction anti-liante supplémentaire se produit entre le ligand ttcn et le métal, ce qui change la nature de l'orbitale HOMO. On observe un déplacement de la bande de luminescence de -19 cm-1/kbar. Tel que pour le complexe de molybdène(IV), le déplacement de la bande de luminescence dépend de la compétition entre les ligands situés sur les différents axes de l'octaèdre. L'interaction liante entre l'ion platine(II) et l'atome de soufre axial est l'effet le plus plausible qui peut induire un déplacement de la bande de luminescence vers les basses énergies. Ceci nous indique que cette interaction domine. Par contre, pour ce qui est du complexe palladium(II), la compétition est remportée par d'autres effets, car le déplacement de la bande de luminescence est de +6 cm-1/kbar. Encore une fois, des calculs, basés sur la théorie de la fonctionnelle de la densité, aident à explorer les causes de ces observations en suggérant des explications corroborées simultanément par les diverses expériences de spectroscopie. Lors du chapitre 5, une étude plus exacte de la structure électronique ainsi que de la dynamique des noyaux de complexes de métaux de transition est présentée. En effet, les complexes de palladium(II) et de platine(II), de type [M(X)4]2-, ont une structure simple, très symétrique. Le premier état excité de ces molécules subit la distorsion Jahn-Teller. On veut établir un protocole de travail pour les expérimentateurs afin d'analyser des spectres de molécules pour lesquelles l'approximation de Born-Oppenheimer n'est pas valide. On utilise la théorie de la fonctionnelle de la densité dépendante du temps ainsi que le modèle de Heidelberg afin de décrire des effets non adiabatique. On tente d'établir l'influence des effets non adiabatiques sur les spectres de ce type de complexe.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Si les principes d’utilisabilité guident la conception de solutions de design interactif pour s’assurer que celles-ci soient « utilisables », quels principes guident la conception d’objets interactifs pour s’assurer que l’expérience subjective de l’usager (UX) soit adéquate et mémorable? Que manque-t-il au cadre de l‘UX pour expliquer, comprendre, et anticiper en tant que designer une expérience mémorable (‘an experience’; Dewey, 1934)? La question centrale est issue d’une double problématique : (1) le cadre théorique de l’UX est incomplet, et (2) les processus et capacités des designers ne sont pas considérés et utilisés à leur pleine capacité en conception UX. Pour répondre à cette question, nous proposons de compléter les modèles de l’UX avec la notion d’expérience autotélique qui appartient principalement à deux cadres théoriques ayant bien cerné l’expérience subjective, soit l’expérience optimale (ou Flow) de Csikszentmihalyi (1988) et l’expérience esthétique selon Schaeffer (2001). L’autotélie est une dimension interne du Flow alors qu’elle couvre toute l’expérience esthétique. L’autotélie est une expérience d’éveil au moment même de l’interaction. Cette prise de conscience est accompagnée d’une imperceptible tension de vouloir faire durer ce moment pour faire durer le plaisir qu’il génère. Trois études exploratoires ont été faites, s’appuyant sur une analyse faite à partir d’un cadre théorique en trois parties : le Flow, les signes d’activité non verbale (les gestes physiques) et verbale (le discours) ont été évalués pour voir comment ceux-ci s’associent. Nos résultats tendent à prouver que les processus spatiaux jouent un rôle de premier plan dans l’expérience autotélique et par conséquent dans une UX optimale. De plus, ils suggèrent que les expériences pragmatique et autotélique sont ancrées dans un seul et même contenu, et que leur différence tient au type d’attention que le participant porte sur l’interaction, l’attention ordinaire ou de type autotélique. Ces résultats nous ont menés à proposer un modèle pour la conception UX. L’élément nouveau, resté jusqu’alors inaperçu, consiste à s’assurer que l’interface (au sens large) appelle une attitude réceptive à l’inattendu, pour qu’une information puisse déclencher les processus spatiaux, offrant une opportunité de passer de l’attention ordinaire à l’attention autotélique. Le nouveau modèle ouvre la porte à une meilleure valorisation des habiletés et processus du designer au sein de l’équipe multidisciplinaire en conception UX.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several studies have highlighted the importance of the cooling period in oil absorption in deep-fat fried products. Specifically, it has been established that the largest proportion of oil which ends up into the food, is sucked into the porous crust region after the fried product is removed from the oil bath, stressing the importance of this time interval. The main objective of this paper was to develop a predictive mechanistic model that can be used to understand the principles behind post-frying cooling oil absorption kinetics, which can also help identifying the key parameters that affect the final oil intake by the fried product. The model was developed for two different geometries, an infinite slab and an infinite cylinder, and was divided into two main sub-models, one describing the immersion frying period itself and the other describing the post-frying cooling period. The immersion frying period was described by a transient moving-front model that considered the movement of the crust/core interface, whereas post-frying cooling oil absorption was considered to be a pressure driven flow mediated by capillary forces. A key element in the model was the hypothesis that oil suction would only begin once a positive pressure driving force had developed. The mechanistic model was based on measurable physical and thermal properties, and process parameters with no need of empirical data fitting, and can be used to study oil absorption in any deep-fat fried product that satisfies the assumptions made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mathematical models that describe the immersion-frying period and the post-frying cooling period of an infinite slab or an infinite cylinder were solved and tested. Results were successfully compared with those found in the literature or obtained experimentally, and were discussed in terms of the hypotheses and simplifications made. The models were used as the basis of a sensitivity analysis. Simulations showed that a decrease in slab thickness and core heat capacity resulted in faster crust development. On the other hand, an increase in oil temperature and boiling heat transfer coefficient between the oil and the surface of the food accelerated crust formation. The model for oil absorption during cooling was analysed using the tested post-frying cooling equation to determine the moment in which a positive pressure driving force, allowing oil suction within the pore, originated. It was found that as crust layer thickness, pore radius and ambient temperature decreased so did the time needed to start the absorption. On the other hand, as the effective convective heat transfer coefficient between the air and the surface of the slab increased the required cooling time decreased. In addition, it was found that the time needed to allow oil absorption during cooling was extremely sensitive to pore radius, indicating the importance of an accurate pore size determination in future studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Determinar os efeitos agudos de diferentes intensidades de pressão expiratória positiva sobre o padrão respiratório e volumes operacionais de pacientes com doença de Parkinson. Métodos: Foram eleitos para o estudo 23 pacientes em estágios II ou III da doença, estando na condição ON , sendo 8 excluídos, e 15 controles saudáveis. Os indivíduos foram submetidos a uma avaliação inicial, constando de dados gerais, avaliação antropométrica, função pulmonar e força muscular respiratória. Após esta etapa inicial, realizou-se a avaliação dos volumes pulmonares com pletismografia optoeletrônica associado a utilização de pressão expiratória positiva (PEP) em três intensidades de pressão positiva, 10 cmH2O, 15 cmH2O e 20 cmH2O em ordem aleatória. Resultados: O grupo Parkinson apresentou valores espirométricos e de força muscular respiratória significativamente menores que o grupo controle (p<0.01). Houve diferença nos valores de volume corrente (Vt) do grupo Parkinson em relação ao grupo controle na respiração tranqüila (p<0.001) e aumento no Vt do grupo Parkinson com uso das três intensidades de PEP (p<0.001), sem diferenças estatisticamente significativas entre as intensidades e com diferença na distribuição compartimental do Vt entre os grupos (p<0.001). O fluxo inspiratório médio e o volume minuto do grupo Parkinson foram menores em relação ao grupo controle na respiração tranqüila (p<0.001) e aumentaram com o uso das três intensidades de PEP (p<0.001), sem diferenças estatisticamente significativas entre as intensidades. Houve diferença na variação dos volumes operacionais entre os grupos em todas as intensidades de PEP (p < 0.001). O volume pulmonar expiratório final não aumentou no grupo Parkinson com uso de PEP. O volume pulmonar inspiratório final aumentou no grupo Parkinson em todas intensidades de PEP (p < 0.001), não havendo diferenças entre as intensidades. Conclusão: Os pacientes com doença de Parkinson apresentam alterações em diferentes componentes do padrão respiratório e a terapia com PEP determina modificações clinicamente importantes nos volumes pulmonares, considerando a intensidade de 10 cmH2O suficientes para este objetivo terapêutico

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BAKGROUND AND OBJECTIVES: Negative pressure pulmonary edema has been defined as non-cardiogenic edema, with transudation of fluid to the interstitial space of the lungs due to an increase in negative intrathoracic pressure secondary to obstruction of the upper airways. This is the case of a healthy patient who underwent general anesthesia and developed acute pulmonary edema after extubation. CASE REPORT: A 23-year old female patient, physical status ASA II, underwent gynecologic videolaparoscopy under general anesthesia. The procedure lasted 3 hours without intercurrence. After extubation the patient developed laryngeal spasm and reduction in oxygen saturation. The patient improved after placement of an oral cannula and administration of oxygen under positive pressure with a face mask. Once the patient was stable she was transferred to the recovery room where, shortly after her arrival, she developed acute pulmonary edema with elimination of bloody serous secretion. Treatment consisted of elevation of the head, administration of oxygen via a face mask, furosemide and fluid restriction. Chest X-ray was compatible with acute pulmonary edema and normal cardiac area. Electrocardiogram (ECG), echocardiogram and cardiac enzymes were normal. The condition of the patient improved and she was discharged from the hospital the following day, asymptomatic. CONCLUSIONS: Acute pulmonary edema associated with obstruction of the upper airways can aggravate surgical procedures with low morbidity, affecting mainly young patients. Early treatment should be instituted because it has a fast evolution and, in most cases, resolves without lasting damages. © Sociedade Brasileira de Anestesiologia, 2008.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Fisiopatologia em Clínica Médica - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP), followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH2O (ZEEP), associated to a manual bilateral thoracic compression. Aim To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients. Methods 15 patients submitted to a coronary artery bypass graft surgery (CABG) were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH2O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH2O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished. Results The inspiratory peak and plateau pressures increased during the procedure (p < 0.001) compared with other pressures during the assessment periods; however, they were within lung safe limits. The expiratory flow before the procedure were 33 ± 7.87 L/min, increasing significantly during the procedure to 60 ± 6.54 L/min (p < 0.001), diminishing to 35 ± 8.17 L/min at 10 minutes and to 36 ± 8.48 L/min at 30 minutes. Hemodynamic and oxygenation variables were not altered. Conclusion The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this preliminary study was to verify the antibacterial potential of cetylpyridinium chloride (CPC) in root canals infected by Enterococcus faecalis. Forty human maxillary anterior teeth were prepared and inoculated with E. faecalis for 60 days. The teeth were randomly assigned to the following groups: 1: Root canal preparation (RCP) + 0.1% CPC with positive-pressure irrigation (PPI, Conventional, NaviTip®); 2: RCP + 0.2% CPC PPI; 3: RCP + 2.5% NaOCl PPI; 4: RCP + 2.5% NaOCl with negative-pressure irrigation system (NPI, EndoVac®); 5: Positive control; and 6: Negative control. Four teeth of each experimental group were evaluated by culture and 4 by scanning electron microscopy (SEM). In all teeth, the root canals were dried and filled with 17% EDTA (pH 7.2) for 3 min for smear layer removal. Samples from the infected root canals were collected and immersed in 7 mL of Letheen Broth (LB), followed by incubation at 37°C for 48 h. Bacterial growth was analyzed by turbidity of culture medium and then observed with a UV spectrophotometer. The irrigating solutions were further evaluated for antimicrobial effect by an agar diffusion test.The statistical data were treated by means, standard deviation, Kruskal-Wallis test and analysis of variance. Significance level was set at 5%. The results showed the presence of E. faecalis after root canal sanitization. The number of bacteria decreased after the use of CPC. In the agar diffusion test, CPC induced large microbial inhibition zones, similar to 2% chlorhexidine and large than 2.5% NaOCl. In conclusion, cetylpyridinium chloride showed antibacterial potential in endodontic infection with E. faecalis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spontaneous contractions of the fetal airways are a well recognized but poorly characterized phenomenon. In the present study spontaneous narrowing of the airways was analyzed in freshly isolated lungs from early to late gestation in fetal pigs and rabbits and in cultured fetal mouse lungs. Propagating waves of contraction traveling proximal to distal were observed in fresh lungs throughout gestation which displaced the lung liquid along the lumen. In the pseudoglandular and canalicular stages (fetal pigs) the frequency ranged from 2.3 to 3.3 contractions/min with a 39 to 46% maximum reduction of lumen diameter. In the saccular stage (rabbit) the frequency was 10 to 12/min with a narrowing of approximately 30%. In the organ cultures the waves of narrowing started at the trachea in whole lungs, or at the main bronchus in lobes (5.2 +/- 1.5 contractions/min, 22 +/- 8% reduction of lumen diameter), and as they proceeded distally along the epithelial tubes the luminal liquid was shifted toward the terminal tubules, which expanded the endbuds. As the tubules relaxed the flow of liquid was reversed. Thus the behavior of airway smooth muscle in the fetal lung is phasic in type (like gastrointestinal muscle) in contrast to that in postnatal lung, where it is tonic. An intraluminal positive pressure of 2.33 +/- 0.77 cm H(2)O was recorded in rabbit fetal trachea. It is proposed that the active tone of the smooth muscle maintains the positive intraluminal pressure and acts as a stimulus to lung growth via the force exerted across the airway wall and adjacent parenchyma. The expansion of the compliant endbuds by the fluid shifts at the airway tip may promote their growth into the surrounding mesenchyme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The patch-clamp technique allows currents to be recorded through single ion channels in patches of cell membrane in the tips of glass pipettes. When recording, voltage is typically applied across the membrane patch to drive ions through open channels and to probe the voltage-sensitivity of channel activity. In this study, we used video microscopy and single-channel recording to show that prolonged depolarization of a membrane patch in borosilicate pipettes results in delayed slow displacement of the membrane into the pipette and that this displacement is associated with the activation of mechanosensitive (MS) channels in the same patch. The membrane displacement, ≈1 μm with each prolonged depolarization, occurs after variable delays ranging from tens of milliseconds to many seconds and is correlated in time with activation of MS channels. Increasing the voltage step shortens both the delay to membrane displacement and the delay to activation. Preventing depolarization-induced membrane displacement by applying positive pressure to the shank of the pipette or by coating the tips of the borosilicate pipettes with soft glass prevents the depolarization-induced activation of MS channels. The correlation between depolarization-induced membrane displacement and activation of MS channels indicates that the membrane displacement is associated with sufficient membrane tension to activate MS channels. Because membrane tension can modulate the activity of various ligand and voltage-activated ion channels as well as some transporters, an apparent voltage dependence of a channel or transporter in a membrane patch in a borosilicate pipette may result from voltage-induced tension rather than from direct modulation by voltage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: El Síndrome de Apnea Hipopnea Obstructiva del Sueño es un trastorno respiratorio del sueño mayor ampliamente conocido, con importantes implicaciones para los pacientes y cuya incidencia ha venido en aumento durante los últimos años; comprende diversas manifestaciones clínicas que varían desde el ronquido hasta consecuencias cardiovasculares importantes. Objetivo: Describir la experiencia de los procedimientos quirúrgicos más utilizados para el tratamiento de pacientes con Trastornos Respiratorios del Sueño en la Clínica Rivas. Diseño: Estudio observacional descriptivo. Métodos: Revisión de 366 historias clínicas de pacientes con diagnóstico clínico y Polisomnográfico de SAHOS intervenidos quirúrgicamente debido al Trastorno Respiratorio del Sueño por rechazo de terapia de presión positiva en 3 años de observación. Resultados: Se evaluaron diferencias en medianas de los cambios del IAH, índice de Saturación de oxigeno basal y mínima, y el índice de microdespertares nocturnos tanto prequirúrgica como postquirúrgicamente. Como medida de evaluación secundaria se evaluaron las complicaciones quirúrgicas. Conclusión: En nuestra institución, como centro de referencia en apnea del sueño, la cirugía ha demostrado que disminuye de forma significativa gravedad del SAHOS y disminuye el riesgo de los pacientes con trastornos respiratorios del sueño que han rechazado el dispositivo de presión positiva.