871 resultados para Grid connected inverters


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In recent years, there has been a growing interest in incorporating microgrids in electrical power networks. This is due to various advantages they present, particularly the possibility of working in either autonomous mode or grid connected, which makes them highly versatile structures for incorporating intermittent generation and energy storage. However, they pose safety issues in being able to support a local island in case of utility disconnection. Thus, in the event of an unintentional island situation, they should be able to detect the loss of mains and disconnect for self-protection and safety reasons. Most of the anti-islanding schemes are implemented within control of single generation devices, such as dc-ac inverters used with solar electric systems being incompatible with the concept of microgrids due to the variety and multiplicity of sources within the microgrid. In this paper, a passive islanding detection method based on the change of the 5th harmonic voltage magnitude at the point of common coupling between grid-connected and islanded modes of operation is presented. Hardware test results from the application of this approach to a laboratory scale microgrid are shown. The experimental results demonstrate the validity of the proposed method, in meeting the requirements of IEEE 1547 standards.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The modern grid system or the smart grid is likely to be populated with multiple distributed energy sources, e.g. wind power, PV power, Plug-in Electric Vehicle (PEV). It will also include a variety of linear and nonlinear loads. The intermittent nature of renewable energies like PV, wind turbine and increased penetration of Electric Vehicle (EV) makes the stable operation of utility grid system challenging. In order to ensure a stable operation of the utility grid system and to support smart grid functionalities such as, fault ride-through, frequency response, reactive power support, and mitigation of power quality issues, an energy storage system (ESS) could play an important role. A fast acting bidirectional energy storage system which can rapidly provide and absorb power and/or VARs for a sufficient time is a potentially valuable tool to support this functionality. Battery energy storage systems (BESS) are one of a range suitable energy storage system because it can provide and absorb power for sufficient time as well as able to respond reasonably fast. Conventional BESS already exist on the grid system are made up primarily of new batteries. The cost of these batteries can be high which makes most BESS an expensive solution. In order to assist moving towards a low carbon economy and to reduce battery cost this work aims to research the opportunities for the re-use of batteries after their primary use in low and ultra-low carbon vehicles (EV/HEV) on the electricity grid system. This research aims to develop a new generation of second life battery energy storage systems (SLBESS) which could interface to the low/medium voltage network to provide necessary grid support in a reliable and in cost-effective manner. The reliability/performance of these batteries is not clear, but is almost certainly worse than a new battery. Manufacturers indicate that a mixture of gradual degradation and sudden failure are both possible and failure mechanisms are likely to be related to how hard the batteries were driven inside the vehicle. There are several figures from a number of sources including the DECC (Department of Energy and Climate Control) and Arup and Cenex reports indicate anything from 70,000 to 2.6 million electric and hybrid vehicles on the road by 2020. Once the vehicle battery has degraded to around 70-80% of its capacity it is considered to be at the end of its first life application. This leaves capacity available for a second life at a much cheaper cost than a new BESS Assuming a battery capability of around 5-18kWhr (MHEV 5kWh - BEV 18kWh battery) and approximate 10 year life span, this equates to a projection of battery storage capability available for second life of >1GWhrs by 2025. Moreover, each vehicle manufacturer has different specifications for battery chemistry, number and arrangement of battery cells, capacity, voltage, size etc. To enable research and investment in this area and to maximize the remaining life of these batteries, one of the design challenges is to combine these hybrid batteries into a grid-tie converter where their different performance characteristics, and parameter variation can be catered for and a hot swapping mechanism is available so that as a battery ends it second life, it can be replaced without affecting the overall system operation. This integration of either single types of batteries with vastly different performance capability or a hybrid battery system to a grid-tie 3 energy storage system is different to currently existing work on battery energy storage systems (BESS) which deals with a single type of battery with common characteristics. This thesis addresses and solves the power electronic design challenges in integrating second life hybrid batteries into a grid-tie energy storage unit for the first time. This study details a suitable multi-modular power electronic converter and its various switching strategies which can integrate widely different batteries to a grid-tie inverter irrespective of their characteristics, voltage levels and reliability. The proposed converter provides a high efficiency, enhanced control flexibility and has the capability to operate in different operational modes from the input to output. Designing an appropriate control system for this kind of hybrid battery storage system is also important because of the variation of battery types, differences in characteristics and different levels of degradations. This thesis proposes a generalised distributed power sharing strategy based on weighting function aims to optimally use a set of hybrid batteries according to their relative characteristics while providing the necessary grid support by distributing the power between the batteries. The strategy is adaptive in nature and varies as the individual battery characteristics change in real time as a result of degradation for example. A suitable bidirectional distributed control strategy or a module independent control technique has been developed corresponding to each mode of operation of the proposed modular converter. Stability is an important consideration in control of all power converters and as such this thesis investigates the control stability of the multi-modular converter in detailed. Many controllers use PI/PID based techniques with fixed control parameters. However, this is not found to be suitable from a stability point-of-view. Issues of control stability using this controller type under one of the operating modes has led to the development of an alternative adaptive and nonlinear Lyapunov based control for the modular power converter. Finally, a detailed simulation and experimental validation of the proposed power converter operation, power sharing strategy, proposed control structures and control stability issue have been undertaken using a grid connected laboratory based multi-modular hybrid battery energy storage system prototype. The experimental validation has demonstrated the feasibility of this new energy storage system operation for use in future grid applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Distributed generation systems must fulfill standards specifications of current harmonics injected to the grid. In order to satisfy these grid requirements, passive filters are connected between inverter and grid. This work compares the characteristic response of the traditional inductive (L) filter with the inductive-capacitive-inductive (LCL) filter. It is shown that increasing the inductance L leads to a good ripple current suppression around the inverter switching frequency. The LCL filter provides better harmonic attenuation and reduces the filter size. The main drawback is the LCL filter impedance, which is characterized by a typical resonance peak, which must be damped to avoid instability. Passive or active techniques can be used to damp the LCL resonance. To address this issue, this dissertation presents a comparison of current control for PV grid-tied inverters with L filter and LCL filter and also discuss the use of active and passive damping for different regions of resonance frequency. From the mathematical models, a design methodology of the controllers was developed and the dynamic behavior of the system operating in closed loop was investigated. To validate the studies developed during this work, experimental results are presented using a three-phase 5kW experimental platform. The main components and their functions are discussed in this work. Experimental results are given to support the theoretical analysis and to illustrate the performance of grid-connected PV inverter system. It is shown that the resonant frequency of the system, and sampling frequency can be associated in order to calculate a critical frequency, below which is essential to perform the damping of the LCL filter. Also, the experimental results show that the active buffer per virtual resistor, although with a simple development, is effective to damp the resonance of the LCL filter and allow the system to operate stable within predetermined parameters.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Power system policies are broadly on track to escalate the use of renewable energy resources in electric power generation. Integration of dispersed generation to the utility network not only intensifies the benefits of renewable generation but also introduces further advantages such as power quality enhancement and freedom of power generation for the consumers. However, issues arise from the integration of distributed generators to the existing utility grid are as significant as its benefits. The issues are aggravated as the number of grid-connected distributed generators increases. Therefore, power quality demands become stricter to ensure a safe and proper advancement towards the emerging smart grid. In this regard, system protection is the area that is highly affected as the grid-connected distributed generation share in electricity generation increases. Islanding detection, amongst all protection issues, is the most important concern for a power system with high penetration of distributed sources. Islanding occurs when a portion of the distribution network which includes one or more distributed generation units and local loads is disconnected from the remaining portion of the grid. Upon formation of a power island, it remains energized due to the presence of one or more distributed sources. This thesis introduces a new islanding detection technique based on an enhanced multi-layer scheme that shows superior performance over the existing techniques. It provides improved solutions for safety and protection of power systems and distributed sources that are capable of operating in grid-connected mode. The proposed active method offers negligible non-detection zone. It is applicable to micro-grids with a number of distributed generation sources without sacrificing the dynamic response of the system. In addition, the information obtained from the proposed scheme allows for smooth transition to stand-alone operation if required. The proposed technique paves the path towards a comprehensive protection solution for future power networks. The proposed method is converter-resident and all power conversion systems that are operating based on power electronics converters can benefit from this method. The theoretical analysis is presented, and extensive simulation results confirm the validity of the analytical work.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Distribution systems are the first volunteers experiencing the benefits of smart grids. The smart grid concept impacts the internal legislation and standards in grid-connected and isolated distribution systems. Demand side management, the main feature of smart grids, acquires clear meaning in low voltage distribution systems. In these networks, various coordination procedures are required between domestic, commercial and industrial consumers, producers and the system operator. Obviously, the technical basis for bidirectional communication is the prerequisite of developing such a coordination procedure. The main coordination is required when the operator tries to dispatch the producers according to their own preferences without neglecting its inherent responsibility. Maintenance decisions are first determined by generating companies, and then the operator has to check and probably modify them for final approval. In this paper the generation scheduling from the viewpoint of a distribution system operator (DSO) is formulated. The traditional task of the DSO is securing network reliability and quality. The effectiveness of the proposed method is assessed by applying it to a 6-bus and 9-bus distribution system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Desde o final do século XVIII, quando se iniciou a revolução industrial, o crescimento económico tem sido assente num consumo elevado de combustíveis fósseis que libertam gases com efeito de estufa. A emissão destes gases e a escassez dos combustíveis fósseis são temas que, desde as últimas duas décadas do século XX, ocupam um lugar de destaque nas agendas de política mundial. A produção de energia através de fontes renováveis surge como alternativa e poderá ser a solução para países com escassos recursos de origem fóssil, como é o caso de Portugal, minimizando também a sua dependência energética do exterior. Uma das medidas de incentivo lançada pelo Governo Português em 2007, foi a criação de um regime simplificado aplicável à microprodução descentralizada de eletricidade através de fontes de energia renováveis e de cogeração. À semelhança da maioria dos países europeus, o principal meio de promoção destes sistemas em Portugal foram as Feed-in-Tariffs, que consistem numa tarifa de venda de energia elétrica de origem renovável acima da tarifa de mercado. Estas tarifas permitiram, sobretudo, o crescimento do setor fotovoltaico em Portugal. Atualmente, o amadurecimento da tecnologia fotovoltaica, associado ao constante aumento das tarifas de energia elétrica, permite que se torne vantajosa a instalação de sistemas fotovoltaicos para autoconsumo. Neste contexto, o atual Governo Português, criou recentemente um regime jurídico aplicável à produção de eletricidade para autoconsumo. O objetivo deste trabalho é demonstrar, com base na minha experiência profissional, a metodologia de dimensionamento de uma central fotovoltaica ligada à Rede Elétrica de Serviço Público. Será utilizado como objeto de estudo um projeto constituído por 28 centrais fotovoltaicas de Miniprodução de 100 kW, dispersas por Portugal Continental, para o qual será efetuada a análise financeira do investimento. Pretende-se ainda apresentar o novo enquadramento legislativo para o Autoconsumo e Pequena Produção distribuída, detalhar as suas principais caraterísticas e efetuar um estudo económico para cada um destes regimes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The forthcoming smart grids are comprised of integrated microgrids operating in grid-connected and isolated mode with local generation, storage and demand response (DR) programs. The proposed model is based on three successive complementary steps for power transaction in the market environment. The first step is characterized as a microgrid’s internal market; the second concerns negotiations between distinct interconnected microgrids; and finally, the third refers to the actual electricity market. The proposed approach is modeled and tested using a MAS framework directed to the study of the smart grids environment, including the simulation of electricity markets. This is achieved through the integration of the proposed approach with the MASGriP (Multi-Agent Smart Grid Platform) system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a critical and quantitative analysis of the influence of the Power Quality in grid connected solar photovoltaic microgeneration installations. First are introduced the main regulations and legislation related with the solar photovoltaic microgeneration, in Portugal and Europe. Next are presented Power Quality monitoring results obtained from two residential solar photovoltaic installations located in the north of Portugal, and is explained how the Power Quality events affect the operation of these installations. Afterwards, it is described a methodology to estimate the energy production losses and the impact in the revenue caused by the abnormal operation of the electrical installation. This is done by comparing the amount of energy that was injected into the power grid with the theoretical value of energy that could be injected in normal conditions. The performed analysis shows that Power Quality severally affects the solar photovoltaic installations operation. The losses of revenue in the two monitored installations M1 and M2 are estimated in about 27% and 22%, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The performance of Grid connected Photovoltaic System working with DCBoost stage is investigated. The DC-Boost Converter topology is deduced from three phase half controlled bridge and controlled by Sliding Mode Control. Due to the fact that Grid connected Photovoltaic System includes Solar cells as a DC source and inverter for grid connection, those are under the scope of this research as well. The advantages of using MPPT are analyzed. The system is simulated in Matlab-Simulink™ environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Seit gut zehn Jahren erlebt die Windenergienutzung in Deutschland einen in der Mitte der 80er Jahre nicht für möglich gehaltenen Aufschwung. Anlagenanzahl und installierte Leistung haben in diesem Zeitraum mit durchschnittlichen jährlichen Wachstumsraten von mehr als 30 Prozent zugenommen, die mittlere installierte Leistung pro neu errichteter Anlage stieg dabei um das Zehnfache und die technische Verfügbarkeit der Anlagen liegt mittlerweile bei über 98 Prozent. Mit größer werdenden Anlagen zeigt sich weiterhin ein klarer Trend zu Blattwinkel verstellbaren Konzepten, mit zunehmend drehzahlvariabler Betriebsweise. Vor dem von Vielen für die kommenden drei bis sechs Jahre prognostizierten Einstieg in die großtechnische Offshore- Windenergienutzung mit den damit verbundenen immensen technologischen und strukturellen Herausforderungen erscheint es sinnvoll, einen kritischen Blick zurückzuwerfen auf die 90er Jahre mit den ihnen zugrunde liegenden förderpolitischen Rahmenbedingungen. Dabei soll die Frage beantwortet werden, welchen konkreten Einfluss die staatlichen Forschungs- und Förderprogramme, besonders das "250 MW Wind"-Programm, auf die Entwicklung der Windenergienutzung hatten, das heißt, unter welchen Bedingungen sich bestimmte Techniklinien durchsetzten, wie der Einfluss eines geschützten Marktes durch gesetzlich garantierte Einspeisetarife auf diese Entwicklung zu bewerten ist und schließlich, welche Fehlentwicklungen möglicher Weise eingetreten sind. Dazu wird mit Hilfe von Lernkurven gezeigt, welche Kostenreduktionen insgesamt erzielt wurden, wie hoch die dazu notwendigen staatlichen Finanzmittel waren und welche Schlussfolgerungen daraus für die Zukunft abgeleitet werden können. Die Arbeit soll insgesamt dazu beitragen, die erreichten technischen Entwicklungsschritte vor dem Hintergrund der förderpolitischen Gegebenheiten besser zu verstehen, Chancen für gezielte Änderungen in der Förderpraxis zu ergreifen und Hinweise auf die Ausgestaltung von zukünftigen Forschungsprogrammen und Entwicklungsschwerpunkten im Bereich der Windenergie zu geben, um weitere Kostensenkungspotenziale auszuschöpfen. Dabei wird sich die zukünftige Schwerpunktsetzung in der programmatischen Ausrichtung der Forschung stärker auf die drei wichtigsten Anwendungsfelder für Windenergieanlagen konzentrieren müssen, die großtechnische Offshore- Anwendung, die netzgebundene, dezentrale Energieversorgung sowie auf Windenergieanlagen zur ländlichen Elektrifizierung in autonomen Versorgungssystemen für Schwellen- und Entwicklungsländer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A test and demonstration facility for PV and PV hybrid systems and system components has been designed and installed at Dalarna University in Sweden. The facility allows studies of complete PV systems or single components in a range of 0.1-10 kW. The facility includes two grid-connected PV systems, a PV Hybrid off-grid system, three emulators and the necessary measurement and control equipment. Tests can be done manually or automatically through programmed test procedures controlled that will be implemented in Labview. The facility shall be used by researchers, professionals of the industry and engineering students.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A common problem when planning large free field PV-plants is optimizing the ground occupation ratio while maintaining low shading losses. Due to the complexity of this task, several PV-plants have been built using various configurations. In order to compare the shading losses of different PV technologies and array designs, empirical performance data of five free field PV-plants operating in Germany was analyzed. The data collected comprised 140 winter days from October 2011 until March 2012. The relative shading losses were estimated by comparing the energy output of selected arrays in the front rows (shading-free) against that of shaded arrays in the back rows of the same plant. The results showed that landscape mounting with mc-Si PV-modules yielded significantly better results than portrait one. With CIGS modules, making cross-table strings using the lower modules was not beneficial as expected and had more losses than a one-string-per-table layout. Parallel substrings with CdTe showed relatively low losses. Among the two CdTe products analyzed, none showed a significantly better performance.