134 resultados para Flicker


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A significant proportion of the processing delays within the visual system are luminance dependent. Thus placing an attenuating filter over one eye causes a temporal delay between the eyes and thus an illusion of motion in depth for objects moving in the fronto-parallel plane, known as the Pulfrich effect. We have used this effect to study adaptation to such an interocular delay in two normal subjects wearing 75% attenuating neutral density filters over one eye. In two separate experimental periods both subjects showed about 60% adaptation over 9 days. Reciprocal effects were seen on removal of the filters. To isolate the site of adaptation we also measured the subjects' flicker fusion frequencies (FFFs) and contrast sensitivity functions (CSFs). Both subjects showed significant adaptation in their FFFs. An attempt to model the Pulfrich and FFF adaptation curves with a change in a single parameter in Kelly's [(1971) Journal of the Optical Society of America, 71, 537-546] retinal model was only partially successful. Although we have demonstrated adaptation in normal subjects to induced time delays in the visual system we postulate that this may at least partly represent retinal adaptation to the change in mean luminance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wind power generation as one of the most popular renewable energy applications is absorbing more and more attention all over the world. However, output power fluctuations of wind farm due to random variations of wind speed can cause network frequency and voltage flicker in power systems. The power quality consequently declines, particularly in an isolated power system such as the power system in a remote community or a small island. This paper proposes an application of superconducting magnetic energy storage (SMES) to minimize output fluctuations of an isolated power system with wind farm. The isolated power system is fed by a diesel generator and a wind generator consisting of a wind turbine and squirrel cage induction machine. The control strategy is detailed and the proposed system is evaluated by simulation in Matlab/Simulink.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high efficiency hard switching constant current LED driver is presented with high overall efficiency, high current precision, high LED efficacy, flicker-free and wide constant current dimming ratio. The high stable lighting source provides the best solution for office light, reading light and LCD backlight. © 2013 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metal-semiconductor-metal (MSM) structures were fabricated by RF-plasma-assisted MBE using different buffer layer structures. One type of buffer structure consists of an AlN high-temperature buffer layer (HTBL) and a GaN intermediate temperature buffer layer (ITBL), another buffer structure consists of just a single A IN HTBL. Systematic measurements in the flicker noise and deep level transient Fourier spectroscopy (DLTFS) measurements were used to characterize the defect properties in the films. Both the noise and DLTFS measurements indicate improved properties for devices fabricated with the use of ITBL and is attributed to the relaxation of residue strain in the epitaxial layer during growth process. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report experiments on high de current stressing in commercial III-V nitride based heterojunction light-emitting diodes. Stressing currents ranging from 100 mA to 200 mA were used. Degradations in the device properties were investigated through detailed studies of the current-voltage (I-V) characteristics, electroluminescence, deep-level transient Fourier spectroscopy and flicker noise. Our experimental data demonstrated significant distortions in the I-V characteristics subsequent to electrical stressing. The room temperature electro-luminescence of the devices exhibited a 25% decrement in the peak emission intensity. Concentration of the deep-levels was examined by deep-level transient Fourier spectroscopy, which indicated an increase in the density of deep-traps from 2.7 x 10(13) cm(-3) to 4.2 x 10(13) cm(-3) at E-1 = E-C - 1.1 eV. The result is consistent with our study of 1/f noise, which exhibited up to three orders of magnitude increase in the voltage noise power spectra. These traps are typically located at energy levels beyond the range that can be characterized by conventional techniques including DLTS. The two experiments, therefore, provide a more complete picture of trap generation due to high dc current stressing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metal-semiconductor-metal (MSM) structures were fabricated by RF-plasma-assisted MBE using different buffer layer structures. One type of buffer structure consists of an AlN high-temperature buffer layer (HTBL) and a GaN intermediate temperature buffer layer (ITBL), another buffer structure consists of just a single A IN HTBL. Systematic measurements in the flicker noise and deep level transient Fourier spectroscopy (DLTFS) measurements were used to characterize the defect properties in the films. Both the noise and DLTFS measurements indicate improved properties for devices fabricated with the use of ITBL and is attributed to the relaxation of residue strain in the epitaxial layer during growth process. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work presented in this thesis covers four major topics of research related to the grid integration of wave energy. More specifically, the grid impact of a wave farm on the power quality of its local network is investigated. Two estimation methods were developed regarding the flicker level Pst generated by a wave farm in relation to its rated power as well as in relation to the impedance angle ψk of the node in the grid to which it is connected. The electrical design of a typical wave farm design is also studied in terms of minimum rating for three types of costly pieces of equipment, namely the VAr compensator, the submarine cables and the overhead line. The power losses dissipated within the farm's electrical network are also evaluated. The feasibility of transforming a test site into a commercial site of greater rated power is investigated from the perspective of power quality and of cables and overhead line thermal loading. Finally, the generic modelling of ocean devices, referring here to both wave and tidal current devices, is investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper gives the first experimental characterisation of the phase noise response of the recently introduced Inverse Class E topology when operated as an amplifier and then as an oscillator. The results indicate that in amplifier and oscillator modes of operation conversion efficiencies of 64%, and 42% respectively are available, and that the excess PM noise added as a consequence of saturated Class E operation results in about a 10 dB increase in PM over that expected from a small-signal Class A amplifier operating at much lower efficiency. Inverse Class E phase transfer dependence on device drain bias and flicker noise are presented in order to show, respectively, that the Inverse Class E amplifier and oscillator follow the trends predicted by conventional phase noise theory. © 2007 EuMA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE:
To elucidate the contribution of environmental versus genetic factors to the significant losses in visual function associated with normal aging.
DESIGN:
A classical twin study.
PARTICIPANTS:
Forty-two twin pairs (21 monozygotic and 21 dizygotic; age 57-75 years) with normal visual acuity recruited through the Australian Twin Registry.
METHODS:
Cone function was evaluated by establishing absolute cone contrast thresholds to flicker (4 and 14 Hz) and isoluminant red and blue colors under steady state adaptation. Adaptation dynamics were determined for both cones and rods. Bootstrap resampling was used to return robust intrapair correlations for each parameter.
MAIN OUTCOME MEASURES:
Psychophysical thresholds and adaptational time constants.
RESULTS:
The intrapair correlations for all color and flicker thresholds, as well as cone absolute threshold, were significantly higher in monozygotic compared with dizygotic twin pairs (P<0.05). Rod absolute thresholds (P = 0.28) and rod and cone recovery rate (P = 0.83; P = 0.79, respectively) did not show significant differences between monozygotic and dizygotic twins in their intrapair correlations, indicating that steady-state cone thresholds and flicker thresholds have a marked genetic contribution, in contrast with rod thresholds and adaptive processes, which are influenced more by environmental factors over a lifetime.
CONCLUSIONS:
Genes and the environment contribute differently to important neuronal processes in the retina and the role they may play in the decline in visual function as we age. Consequently, retinal structures involved in rod thresholds and adaptive processes may be responsive to appropriate environmental manipulation. Because the functions tested are commonly impaired in the early stages of age-related macular degeneration, which is known to have a multifactorial etiology, this study supports the view that pathogenic pathways early in the disease may be altered by appropriate environmental intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. It has been argued that the threshold for detecting frequency-doubling (FD) technology perimeter stimuli differs from the threshold for perceiving spatial structure (pattern) in the same targets. Thresholds for perceiving spatial structure have typically been assessed using orientation-identification experiments. The authors investigated the influence of orientation, edge profile, and psychophysical method on the origin of the reported differences in detection and orientation-identification thresholds for FD gratings.

METHODS. Detection and orientation-identification thresholds were determined in 12 observers with the use of FD stimuli (0.25 cyc/deg, 25 Hz) presented centrally and at 15° eccentricity. Edge profile (square- and Gaussian-windowed) and orientation (horizontal, vertical, and oblique) were independently modified. Detection thresholds were also measured for spatially uniform flickering targets (25 Hz). Orientation-identification thresholds using a two-alternative forced choice (2-AFC) and a two-interval forced choice (2-IFC) method were also compared in five experienced observers.

RESULTS. Orientation-identification and detection thresholds did not significantly differ under any condition tested. Orientation-identification thresholds obtained with 2-AFC were not significantly different from those obtained with 2-IFC. Thresholds for spatially uniform flicker were significantly lower than for FD stimuli.

CONCLUSIONS. The authors found that orientation-identification and detection thresholds for FD gratings did not differ and argue that recent findings to the contrary arise from the inappropriate use of spatially uniform flicker targets as alternatives in 2-IFC experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Age-related macular degeneration (AMD) is the most common cause of blindness in older people in developed countries, and risk factors for this condition may be classified as genetic and environmental. Apolipoprotein E is putatively involved in the transport of the macular pigment (MP) carotenoids lutein (L) and zeaxanthin (Z) in serum and may also influence retinal capture of these compounds. This study was designed to investigate the relationship between macular pigment optical density (MPOD) and ApoE genotype. METHODS: This was a cross-sectional study of 302 healthy adult subjects. Dietary intake of L and Z was assessed by food frequency questionnaire, and MPOD was measured by customized heterochromatic flicker photometry. Serum L and Z were measured by HPLC. ApoE genotyping was performed by direct polymerase chain reaction amplification and DNA nucleotide sequencing from peripheral blood. RESULTS: Genotype data were available on 300 of the 302 (99.3%) subjects. The mean (+/- SD) age of the subjects in this study was 47.89 +/- 11.05 (range, 21-66) years. Subjects were classed into one of three ApoE genotype groups, as follows: group 1, epsilon2epsilon2 or epsilon2epsilon3; group 2, epsilon3epsilon3; group 3, epsilon2epsilon4 or epsilon3epsilon4 or epsilon4epsilon4. All three groups were statistically comparable in terms of age, sex, body mass index, cigarette smoking, and dietary and serum levels of L and Z. There was a statistically significant association between ApoE genotype and MPOD. Subjects who had at least one epsilon4 allele had a higher MPOD across the macula than subjects without this allele (group 1 MPOD area, 0.70 +/- 0.40; group 2 MPOD area, 0.67 +/- 0.42; group 3 MPOD area, 0.85 +/- 0.46; one-way ANOVA, P = 0.014. CONCLUSIONS: These results suggest that ApoE genotype status is associated with MPOD. This association may explain, at least in part, the putative protective effect of the epsilon4 allele for AMD and is consistent with the view that apolipoprotein profile influences the transport and/or retinal capture of circulating L and/or Z.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Age-related macular degeneration (AMD) is the most common cause of blindness in older people in developed countries, and risk for this condition may be classified as genetic or environmental, with an interaction between such factors predisposing to this disease. This study investigated the relationship between AMD risk genes, macular pigment optical density (MPOD), which may protect against AMD, and serum concentrations of the macular carotenoids, lutein (L) and zeaxanthin (Z). This was a cross-sectional study of 302 healthy adult subjects. Dietary intake of L and Z was assessed by food frequency questionnaire, and MPOD was measured by customized heterochromatic flicker photometry. We also calculated MPOD Area as the area of MP under the spatial profile curve, to reflect MP across the macula. Serum L and Z were measured by HPLC. Genotyping of tag SNPs in the genes CFH, ARMS2, C3, C2 and BF was undertaken with multiplex polymerase chain reaction (PCR) and primer extension methodology (ABI Snapshot, ABI Warrington UK) on DNA extracted from peripheral blood. The mean ± SD (range) age of the subjects in this study was 48 ± 11 (21-66) years. There was a statistically significant association between CFH genotype and family history of AMD, with subjects having two non-risk CFH haplotypes (n =35), or one non-risk and one protective CFH haplotype (n = 33), being significantly more likely to have a negative family history of AMD (Pearson Chi square: p = 0.001). There was no significant association between the AMD risk genes investigated and either MPOD (One way ANOVA: p > 0.05) or serum concentrations of L or Z (One way ANOVA: p > 0.05, for both). Subjects who were homozygous for risk alleles of both CFH and ARMS2 (n = 4) had significantly lower MPOD at 0.5_ and 1_ retinal eccentricity (Independent samples t test: p

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Late age-related maculopathy (ARM) is responsible for the majority of blind registrations in the Western world among persons over 50 years of age. It has devastating effects on quality of life and independence and is becoming a major public health concern. Current treatment options are limited and most aim to slow progression rather than restore vision; therefore, early detection to identify those patients most suitable for these interventions is essential. In this work, we review the literature encompassing the investigation of visual function in ARM in order to highlight those visual function parameters which are affected very early in the disease process. We pay particular attention to measures of acuity, contrast sensitivity (CS), cone function, electrophysiology, visual adaptation, central visual field sensitivity and metamorphopsia. We also consider the impact of bilateral late ARM on visual function as well as the relationship between measures of vision function and self-reported visual functioning. Much interest has centred on the identification of functional changes which may predict progression to neovascular disease; therefore, we outline the longitudinal studies, which to date have reported dark-adaptation time, short-wavelength cone sensitivity, colour-match area effect, dark-adapted foveal sensitivity, foveal flicker sensitivity, slow recovery from glare and slower foveal electroretinogram implicit time as functional risk factors for the development of neovascular disease. Despite progress in this area, we emphasise the need for longitudinal studies designed in light of developments in disease classification and retinal imaging, which would ensure the correct classification of cases and controls, and provide increased understanding of the natural course and progression of the disease and further elucidate the structure-function relationships in this devastating disorder.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the clinical and electrophysiologic natural history of Stargardt disease and correlate with the genotype. Design: Cohort study of 59 patients. Methods: Clinical history, examination, and electrophysiologic assessment were undertaken in a longitudinal survey. Patients were classified into 3 groups based on electrophysiologic findings, as previously published: Group 1 had dysfunction confined to the macula; Group 2 had macular and generalized cone system dysfunction; and Group 3 had macular and both generalized cone and rod system dysfunction. At baseline, there were 27 patients in Group 1, 17 in Group 2, and 15 in Group 3. Amplitude reduction of >50% in the relevant electroretinogram (ERG) component or a peak time shift of >3 ms for the 30 Hz flicker ERG or bright flash a-wave was considered clinically significant ERG deterioration. Molecular screening of ABCA4 was undertaken. Results: The mean age at baseline was 31.7 years, with the mean follow-up interval being 10.5 years. A total of 22% of patients from Group 1 showed ERG group transition during follow-up, with 11% progressing to Group 2 and 11% to Group 3. Forty-seven percent of patients in Group 2 progressed to Group 3. There was clinically significant ERG deterioration in 54% of all subjects: 22% of Group 1, 65% of Group 2, and 100% of Group 3. At least 1 disease-causing ABCA4 variant was identified in 47 patients. Conclusions: All patients with initial rod ERG involvement demonstrated clinically significant electrophysiologic deterioration; only 20% of patients with normal full-field ERGs at baseline showed clinically significant progression. Such data assist counseling by providing more accurate prognostic information and are also highly relevant in the design, patient selection, and monitoring of potential therapeutic interventions. © 2013 Elsevier Inc. All rights reserved.