485 resultados para Flaps (Airplanes)
Resumo:
Peer reviewed
Resumo:
This project aims to develop a methodology for designing and conducting a systems engineering analysis to build and fly continuously, day and night, propelled uniquely by solar energy for one week with a 0.25Kg payload consuming 0.5 watt without fuel or pollution. An airplane able to fly autonomously for many days could find many applications. Including coastal or border surveillance, atmospherical and weather research and prediction, environmental, forestry, agricultural, and oceanic monitoring, imaging for the media and real-estate industries, etc. Additional advantages of solar airplanes are their low cost and the simplicity with which they can be launched. For example, in the case of potential forest fire risks during a warm and dry period, swarms of solar airplanes, easily launched with the hand, could efficiently monitor a large surface, reporting rapidly any fire starts. This would allow a fast intervention and thus reduce the cost of such disaster, in terms of human and material losses. At higher dimension, solar HALE platforms are expected to play a major role as communication relays and could replace advantageously satellites in a near future.
Resumo:
The reconstruction of extended maxillary and mandibular defects with prefabricated free flaps is a two stage procedure, that allows immediate function with implant supported dentures. The appropriate delay between prefabrication and reconstruction depends on the interfacial strength of the bone–implant surface. The purpose of this animal study was to evaluate the removal torque of unloaded titanium implants in the fibula, the scapula and the iliac crest. Ninety implants with a sandblasted and acid-etched (SLA) surface were tested after healing periods of 3, 6, and 12 weeks, respectively. Removal torque values (RTV) were collected using a computerized counterclockwise torque driver. The bicortical anchored 8 mm implants in the fibula revealed values of 63.73 Ncm, 91.50 Ncm, and 101.83 Ncm at 3, 6, and 12 weeks, respectively. The monocortical anchorage in the iliac crest showed values of 71.40 Ncm, 63.14 Ncm, and 61.59 Ncm with 12 mm implants at the corresponding times. The monocortical anchorage in the scapula demonstrated mean RTV of 62.28 Ncm, 97.63 Ncm, and 99.7 Ncm with 12 mm implants at 3, 6, and 12 weeks, respectively. The study showed an increase of removal torque with increasing healing time. The interfacial strength for bicortical anchored 8 mm implants in the fibula was comparable to monocortical anchored 12 mm implants in the iliac crest and the scapula at the corresponding times. The resistance to shear seemed to be determined by the type of anchorage (monocortical vs. bicortical) and the length of the implant with greater amount of bone–implant interface.
Resumo:
Purpose: The purpose of this study was to identify retrospectively the predictors of implant survival when the flapless protocol was used in two private dental practices. Materials and Methods: The collected data were initially computer searched to identify the patients; later, a hand search of patient records was carried out to identify all flapless implants consecutively inserted over the last 10 years. The demographic information gathered on statistical predictors included age, sex, periodontal and peri-implantitis status, smoking, details of implants inserted, implant locations, placement time after extraction, use of simultaneous guided hard and soft tissue regeneration procedures, loading protocols, type of prosthesis, and treatment outcomes (implant survival and complications). Excluded were any implants that required flaps or simultaneous guided hard and soft tissue regeneration procedures, and implants narrower than 3.25 mm. Results: A total of 1,241 implants had been placed in 472 patients. Life table analysis indicated cumulative 5-year and 10-year implant survival rates of 97.9% and 96.5%, respectively. Most of the failed implants occurred in the posterior maxilla (54%) in type 4 bone (74.0%), and 55.0% of failed implants had been placed in smokers. Conclusion: Flapless dental implant surgery can yield an implant survival rate comparable to that reported in other studies using traditional flap techniques.
Resumo:
Background Numerous studies demonstrate the generation and short-term survival of adipose tissue; however, long-term persistence remains elusive. This study evaluates long-term survival and transferability of de novo adipose constructs based on a ligated vascular pedicle and tissue engineering chamber combination. Methods Defined adipose tissue flaps were implanted into rats in either intact or perforated domed chambers. In half of the groups, the chambers were removed after 10 weeks and the constructs transferred on their vascular pedicle to a new site, where they were observed for a further 10 weeks. In the remaining groups, the tissue construct was observed for 20 weeks inside the chamber. Tissue volume was assessed using magnetic resonance imaging and histologic measures, and constructs were assessed for stability and necrosis. Sections were assessed histologically and for proliferation using Ki-67. Results At 20 weeks, volume analysis revealed an increase in adipose volume from 0.04 ± 0.001 ml at the time of insertion into the chambers to 0.27 ± 0.004 ml in the closed and 0.44 ± 0.014 ml in the perforated chambers. There was an additional increase of approximately 10 to 15 percent in tissue volume in flaps that remained in chambers for 20 weeks, whereas the volume of the transferred tissue not in chambers remained unaltered. Histomorphometric assessment of the tissues documented no signs of hypertrophy, fat necrosis, or atypical changes of the newly generated tissue. Conclusion This study presents a promising new method of generating significant amounts of mature, vascularized, stable, and transferable adipose tissue for permanent autologous soft-tissue replacement.
Resumo:
A novel method of spontaneous generation of new adipose tissue from an existing fat flap is described. A defined volume of fat flap based on the superficial inferior epigastric vascular pedicle in the rat was elevated and inset into a hollow plastic chamber implanted subcutaneously in the groin of the rat. The chamber walls were either perforated or solid and the chambers either contained poly(D,L-lactic-co-glycolic acid) (PLGA) sponge matrix or not. The contents were analyzed after being in situ for 6 weeks. The total volume of the flap tissue in all groups except the control groups, where the flap was not inserted into the chambers, increased significantly, especially in the perforated chambers (0.08 ± 0.007 mL baseline compared to 1.2 ± 0.08 mL in the intact ones). Volume analysis of individual component tissues within the flaps revealed that the adipocyte volume increased and was at a maximum in the chambers without PLGA, where it expanded from 0.04 ± 0.003 mL at insertion to 0.5 ± 0.08 mL (1250% increase) in the perforated chambers and to 0.16 ± 0.03 mL (400% increase) in the intact chambers. Addition of PLGA scaffolds resulted in less fat growth. Histomorphometric analysis rather than simple hypertrophy documented an increased number of adipocytes. The new tissue was highly vascularized and no fat necrosis or atypical changes were observed.
Resumo:
Mrs. Monasch is shown as a young woman wearing a gray translucent shawl and a lace bonnet with ornate flaps coming down over the ears. Some of her black hair is showing. She is shown in a 3/4 view; the eyes are lustrous, the corners of the mouth are raised in a half smile. On backing of original frame: "Zum Andencken von Ihren Schwiegersohn, J. Wollstein d. 20th February 1839" (In memory of your son-in-law J. Wollstein Feb 20th, 1839).
Resumo:
Microneurovascular free muscle transfer with cross-over nerve grafts in facial reanimation Loss of facial symmetry and mimetic function as seen in facial paralysis has an enormous impact on the psychosocial conditions of the patients. Patients with severe long-term facial paralysis are often reanimated with a two-stage procedure combining cross-facial nerve grafting, and 6 to 8 months later with microneurovascular (MNV) muscle transfer. In this thesis, we recorded the long-term results of MNV surgery in facial paralysis and observed the possible contributing factors to final functional and aesthetic outcome after this procedure. Twenty-seven out of forty patients operated on were interviewed, and the functional outcome was graded. Magnetic resonance imaging (MRI) of MNV muscle flaps was done, and nerve graft samples (n=37) were obtained in second stage of the operation and muscle biopsies (n=18) were taken during secondary operations.. The structure of MNV muscles and nerve grafts was evaluated using histological and immunohistochemical methods ( Ki-67, anti-myosin fast, S-100, NF-200, CD-31, p75NGFR, VEGF, Flt-1, Flk-1). Statistical analysis was performed. In our studies, we found that almost two-thirds of the patients achieved good result in facial reanimation. The longer the follow-up time after muscle transfer the weaker was the muscle function. A majority of the patients (78%) defined their quality of life improved after surgery. In MRI study, the free MNV flaps were significantly smaller than originally. A correlation was found between good functional outcome and normal muscle structure in MRI. In muscle biopsies, the mean muscle fiber diameter was diminished to 40% compared to control values. Proliferative activity of satellite cells was seen in 60% of the samples and it tended to decline with an increase of follow-up time. All samples showed intramuscular innervation. Severe muscle atrophy correlated with prolonged intraoperative ischaemia. The good long-term functional outcome correlated with dominance of fast fibers in muscle grafts. In nerve grafts, the mean number of viable axons amounted to 38% of that in control samples. The grafted nerves characterized by fibrosis and regenerated axons were thinner than in control samples although they were well vascularized. A longer time between cross facial nerve grafting and biopsy sampling correlated with a higher number of viable axons. P75Nerve Growth Factor Receptor (p75NGFR) was expressed in every nerve graft sample. The expression of p75NGFR was lower in older than in younger patients. A high expression of p75NGFR was often seen with better function of the transplanted muscle. In grafted nerve Vascular Endothelial Growth Factor (VEGF) and its receptors were expressed in nervous tissue. In conclusion, most of the patients achieved good result in facial reanimation and were satisfied with the functional outcome. The mimic function was poorer in patients with longer follow-up time. MRI can be used to evaluate the structure of the microneurovascular muscle flaps. Regeneration of the muscle flaps was still going on many years after the transplantation and reinnervation was seen in all muscle samples. Grafted nerves were characterized by fibrosis and fewer, thinner axons compared to control nerves although they were well vascularized. P75NGFR and VEGF were expressed in human nerve grafts with higher intensity than in control nerves which is described for the first time.
Resumo:
The risk is obvious for soft tissue complications after operative treatment of the Achilles tendon, calcaneal bone or after ankle arthroplasty. Such complications after malleolar fractures are, however, seldom seen. The reason behind these complications is that the soft tissue in this region is tight and does not allow much tension to the wound area after surgery. Furthermore the area of operation may be damaged by swelling after the injury, or can be affected by peripheral vascular disease. While complications in this area are unavoidable, they can be diminished. This study attempts to highlight the possible predisposing factors leading to complications in these operations and on the other hand, to determine the solutions to solve soft tissue problems in this region. The study consists of five papers. The first article is a reprint on the soft tissue reconstruction of 25 patients after their complicated Achilles tendon surgeries were analysed. The second study reviews a series of 126 patients after having undergone an operative treatment of calcaneal bone fractures and analyses the complications and possible reasons behind them. The third part analyses a series of corrections of 35 soft tissue complications after calcaneal fracture operations. The fourth part reviews a series of 7 patients who had undergone complicated ankle arthroplasties. The last article presents a series of post operative lateral defects of the ankle treated with a less frequently used distally based peroneus brevis muscle flap and analyses the results. What can be conducted from these studies is that in general, the results after the correction of even severe soft tissue complications in the ankle region are good. For the small defects around the Achilles tendon, the local flaps are useful, but the larger defects are best treated with a free flap. We found that a long delay from trauma to surgery and a long operating time were predisposing factors that lead to soft tissue complications after operatively treated calcaneal bone fractures. The more severe the injury, the greater the risk for wound complication. Surprisingly, the long-term results after infected calcaneal osteosyntheses were acceptable and the calcaneal bone seems to tolerate chronic infections very well if the soft tissue is reconstructed successfully. Behind the complicated ankle arthroplasties, unexpectedly high number of cases experiencing arteriosclerosis of the lower extremity was found. These complications lead to ankle fusion but can be solved with a free flap if the vascularity is intact or can be reconstructed. For this reason a vascular examination of the lower extremity arteries of the patients going to ankle arthroplasty is strongly recommended. Moreover postoperative lateral malleolar wound infections which typically create lateral ankle defects can successfully be treated with a peroneus brevis muscle flap covered with a free skin graft.
Resumo:
Breast reconstruction is performed for 10-15 % of women operated on for breast cancer. A popular method is the TRAM (transverse rectus abdominis musculocutaneous) flap formed of the patient’s own abdominal tissue, a part of one of the rectus abdominis muscles and a transverse skin-subcutis area over it. The flap can be raised as a pedicled or a free flap. The pedicled TRAM flap, based on its nondominant pedicle superior epigastric artery (SEA), is rotated to the chest so that blood flow through SEA continues. The free TRAM flap, based on its dominant pedicle deep inferior epigastric artery (DIEA), is detached from the abdomen, transferred to the chest, and DIEA and vein are anastomosed to vessels on the chest. Cutaneous necrosis is seen in 5–60 % of pedicled TRAM flaps and in 0–15 % of free TRAM flaps. This study was the first one to show with blood flow measurements that the cutaneous blood flow is more generous in free than in pedicled TRAM flaps. After this study the free TRAM flap has exceeded the pedicled flap in popularity as a breast reconstruction method, although the free flap it is technically a more demanding procedure than the pedicled TRAM flap. In pedicled flaps, a decrease in cutaneous blood flow was observed when DIEA was ligated. It seems that SEA cannot provide sufficient blood flow on the first postoperative days. The postoperative cutaneous blood flow in free TRAM flaps was more stable than in pedicled flaps. Development of cutaneous necrosis of pedicled TRAM flaps could be predicted based on intraoperative laser Doppler flowmetry (LDF) measurements. The LDF value on the contralateral skin of the flap decreased to 43 ± 7 % of the initial value after ligation of the DIEA in flaps developing cutaneous necrosis during the next week. Endothelin-1 (ET-1) is a powerful vasoconstrictory peptide secreted by vascular endothelial cells. A correlation was found between plasma ET-1 concentrations and peripheral vasoconstriction developing during and after breast reconstructions with a pedicled TRAM flap. ET-1 was not associated with the development of cutaneous necrosis. Felodipine, a vasodilating calcium channel antagonist, had no effect on plasma ET-1 concentrations, peripheral vasoconstriction or development of cutaneous necrosis in free TRAM flaps. Body mass index and thickness of abdominal were not associated with cutaneous necrosis in pedicled TRAM flaps.
Resumo:
Soft tissue sarcomas (STS) are rare tumors of soft tissue occurring most frequently in the extremities. Modern treatment of extremity STS is based on limb-sparing surgery combined with radiotherapy. To prevent local recurrence, a healthy tissue margin of 2.5 cm around the resected tumor is required. This results in large defects of soft tissue and bone, necessitating the use of reconstructive surgery to achieve wound closure. When local or pedicled soft tissue flaps are unavailable, reconstruction with free flaps is used. Free flaps are elevated at a distant site, and have their blood flow restored at the recipient site through microvascular anastomosis. When limb-sparing surgery is made impossible, amputation is the only option. Proximal amputation such as forequarter amputation (FQA) causes considerable morbidity, but is nevertheless warranted for carefully selected patients for cure or palliation. 116 patients treated in 1985 - 2006 were included in the study. Of these, 93 patients treated with limb-sparing surgery and microvascular reconstructive surgery after resection of extremity STS. 25 patients who underwent FQA were also included. Patients were identified and their medical records retrospectively reviewed. In all, 105 free flap procedures were performed for 103 patients. A total of 95 curatively treated STS patients were included in survival analysis. The latissimus dorsi, used in 56% of cases, was the most frequently used free flap. Free flap success rate was 96%. There were 9% microvascular anastomosis complications and 15% wound complications. For curatively treated STS patients, local recurrence-free survival at 5 years was 73.1%, metastasis-free survival 58.3%, and overall disease-specific survival 68.9%. Functional results were good, with 75% of patients regaining normal or near-normal function after lower extremity, and 55% after upper extremity STS resection. Among curatively treated forequarter amputees, 5-year disease-free survival was 44%. In the palliatively treated group median time until disease death was 14 months. Microvascular reconstruction after extremity soft tissue sarcoma resection is safe and reliable, and produces well-healing wounds allowing early oncological treatment. Oncological outcome after these procedures is comparable to that of other extremity sarcoma patients. Functional results are generally good. Forequarter amputation is a useful treatment option for soft tissue tumors of the shoulder girdle and proximal upper extremity. When free flap coverage of extended forequarter amputation is required, the preferable flap is a fillet flap from the amputated extremity. Acceptable oncological outcome is achieved for curatively treated FQA patients. In the palliatively treated patient considerable periods of increased quality of life can be achieved.
Resumo:
This paper describes the use of simulation in the planning and operation of a small fleet of aircraft typical of the air force of a developing country. We consider a single flying base, where the opera tionally ready aircraft are stationed, and a repair depot, where the planes are overhauled. The measure of effectiveness used is "system availability, the percentage of airplanes that are usable. The system is modeled in GPSS as a cyclic queue process. The simulation model is used to perform sensitivity analyses and to validate the principal assumptions of the analytical model on which the simulation model is based.
Resumo:
This study aims to determine optimal locations of dual trailing-edge flaps and blade stiffness to achieve minimum hub vibration levels in a helicopter, with low penalty in terms of required trailing-edge flap control power. An aeroelastic analysis based on finite elements in space and time is used in conjunction with an optimal control algorithm to determine the flap time history for vibration minimization. Using the aeroelastic analysis, it is found that the objective functions are highly nonlinear and polynomial response surface approximations cannot describe the objectives adequately. A neural network is then used for approximating the objective functions for optimization. Pareto-optimal points minimizing both helicopter vibration and flap power ale obtained using the response surface and neural network metamodels. The two metamodels give useful improved designs resulting in about 27% reduction in hub vibration and about 45% reduction in flap power. However, the design obtained using response surface is less sensitive to small perturbations in the design variables.
Resumo:
To investigate the use of centre of gravity location on reducing cyclic pitch control for helicopter UAV's (unmanned air vehicles) and MAV's (micro air vehicles). Low cyclic pitch is a necessity to implement the swashplateless rotor concept using trailing edge flaps or active twist using current generation low authority piezoceramic actuators. Design/methodology/approach – An aeroelastic analysis of the helicopter rotor with elastic blades is used to perform parametric and sensitivity studies of the effects of longitudinal and lateral center of gravity (cg) movements on the main rotor cyclic pitch. An optimization approach is then used to find cg locations which reduce the cyclic pitch at a given forward speed. Findings – It is found that the longitudinal cyclic pitch and lateral cyclic pitch can be driven to zero at a given forward speed by shifting the cg forward and to the port side, respectively. There also exist pairs of numbers for the longitudinal and lateral cg locations which drive both the cyclic pitch components to zero at a given forward speed. Based on these results, a compromise optimal cg location is obtained such that the cyclic pitch is bounded within ±5° for a BO105 helicopter rotor. Originality/value – The reduction in the cyclic pitch due to helicopter cg location is found to significantly reduce the maximum magnitudes of the control angles in flight, facilitating the swashplateless rotor concept. In addition, the existence of cg locations which drive the cyclic pitches to zero allows for the use of active cg movement as a way to replace the cyclic pitch control for helicopter MAV's.