827 resultados para Femoral shaft Fractures


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since the 1960s the ilioinguinal approach by Letournel with the three anatomic windows has been successfully established for the treatment of acetabular fractures involving predominantly the anterior column. The previous standard approach, the iliofemoral approach by Smith-Petersen, is still used for the therapy of anterior wall or isolated femoral head fractures. The increase in acetabular fractures in the elderly with lateral compression fractures after lateral falls, characterized by medial displacement of the quadrilateral plate and superomedial dome impaction, led to the use of the intrapelvic modified Stoppa approach with or without the first window of the ilioinguinal approach in the 1990s. To combine the advantages of the second and third windows of the ilioinguinal approach and the medial view of the modified Stoppa approach the Berne research group recently introduced the pararectus approach in acetabular surgery, which can be used as a less invasive acetabular surgical (LIAS) technique especially in the elderly.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. METHODS Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). SETTING Single Level 1 University Hospital Trauma Center. MAIN OUTCOME MEASUREMENTS The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. RESULTS Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). CONCLUSIONS The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. LEVEL OF EVIDENCE Therapeutic level II.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction The risk for late periprosthetic fractures is higher in patients treated for a neck of femur fracture compared to those treated for osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated if a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite sawbone model. Method A biomechanical composite sawbone model was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented stem were implanted by an experienced surgeon, in 7 sawbones each and loaded at 40 deg/s internal rotation until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874). Data are non-parametric and tested with Mann-Whitney U-test. Results The mean torque load to fracture was 154.1 NM (SD 4.4) for the 44-1 stem and 229 NM (SD10.9) for the 44-4 stem (p = 0.01). The mean fracture energy was 9.6 J (SD1.2) for the 44-1 stem and 17.2 J (SD2.0) for the 44-4 stem (p = 0.14). Conclusion the use of a large body polished tapered cemented stem for neck of femur fractures increases the torque to failure in a biomechanical model and therefore is likely to reduce late periprosthetic fracture risk in this vulnerable cohort.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim This prospective cohort study investigated whether the use of preoperative anticoagulants is an independent risk factor for the outcomes of surgical treatment of patients with a neck of femur fracture. Methods Data was obtained from a prospectively collected database. All patients admitted for a neck of femur fracture between Nov 2010 and Oct 2011 were included. This resulted in three hundred twenty-eight patients with 330 neck of femur fractures. Four groups were defined; patients preoperatively (i) on aspirin (n = 105); (ii) on clopidogrel (n = 28); (iii) on warfarin (n = 30), and; (iv) without any anticoagulation history (n = 167, the control group). The non-warfarin group included the aspirin group, clopidogrel group and the control group. Primary outcome was the in-hospital mortality. Secondary outcomes were the postoperative complications, return to theatre and length of stay. Results Thirteen in-hospital deaths were identified, 4 deaths in the aspirin group, 1 death in the clopidogrel group, 2 deaths in the warfarin group and 6 deaths in the control group. No significant difference in the mortality rates was found between the different groups. Also in the secondary outcomes, no significant difference was found between the four groups. A trend to a higher wound complication rate for the warfarin group was detected. Conclusion The use of clopidrogel or aspirin pre operatively is not an influence on short term patient outcome for patients with a neck of femur fracture. Surgical procedures should not be delayed to reverse their influence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: The risk for late periprosthetic femoral fractures is higher in patients treated for a neck of femur fracture compared to osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated whether a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite Sawbone model. Material and methods: A biomechanical bone analogue was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented femoral stem were implanted by an experienced surgeon in 7 bone analogues each and internally rotated at 40°/s until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874, MI, USA). The data were non-parametric and therefore tested with the Mann-Whitney U-test. Results: The median torque to fracture was 156.7 Nm (IQR 19.7) for the 44-1 stem and 237.1 Nm (IQR 52.9) for the 44-4 stem (p=0.001). The median fracture energy was 8.5J (IQR 7.3) for the 44-1 stem and 19.5J (IQR 8.8) for the 44-4 stem (p=0.014). Conclusions: The use of a large body polished tapered cemented stems for neck of femur fractures increases the torque to failure in a biomechanical model and therefore is likely to reduce late periprosthetic fracture risk in this vulnerable cohort.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fatigue fracture is an overuse injury commonly encountered in military and sports medicine, and known to relate to intensive or recently intensified physical activity. Bone responds to increased stress by enhanced remodeling. If physical stress exceeds bone s capability to remodel, accumulation of microfractures can lead to bone fatigue and stress fracture. Clinical diagnosis of stress fractures is complex and based on patient s anamnesis and radiological imaging. Bone stress fractures are mostly low-risk injuries, healing well after non-operative management, yet, occurring in high-risk areas, stress fractures can progress to displacement, often necessitating surgical treatment and resulting in prolonged morbidity. In the current study, the role of vitamin D as a predisposing factor for fatigue fractures was assessed using serum 25OHD level as the index. The average serum 25OHD concentration was significantly lower in conscripts with fatigue fracture than in controls. Evaluating TRACP-5b bone resorption marker as indicator of fatigue fractures, patients with elevated serum TRACP-5b levels had eight times higher probability of sustaining a stress fracture than controls. Among the 154 patients with exercise induced anterior lower leg pain and no previous findings on plain radiography, MRI revealed a total of 143 bone stress injuries in 86 patients. In 99% of the cases, injuries were in the tibia, 57% in the distal third of the tibial shaft. In patients with injury, forty-nine (57%) patients exhibited bilateral stress injuries. In a 20-year follow-up, the incidence of femoral neck fatigue fractures prior to the Finnish Defence Forces new regimen in 1986 addressing prevention of these fractures was 20.8/100,000, but rose to 53.2/100,000 afterwards, a significant 2.6-fold increase. In nineteen subjects with displaced femoral neck fatigue fractures, ten early local complications (in first postoperative year) were evident, and after the first postoperative year, osteonecrosis of the femoral head in six and osteoarthritis of the hip in thirteen patients were found. It seems likely that low vitamin D levels are related to fatigue fractures, and that an increasing trend exists between TRACP-5b bone resorption marker elevation and fatigue fracture incidence. Though seldom detected by plain radiography, fatigue fractures often underlie unclear lower leg stress-related pain occurring in the distal parts of the tibia. Femoral neck fatigue fractures, when displaced, lead to long-term morbidity in a high percentage of patients, whereas, when non-displaced, they do not predispose patients to subsequent adverse complications. Importantly, an educational intervention can diminish the incidence of fracture displacement by enhancing awareness and providing instructions for earlier diagnosis of fatigue fractures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Traumatic posterior dislocation of the hip associated with a fracture of the posterior acetabular wall and of the neck of the femur is a rare injury. A 29-year-old man presented at a level 1 trauma centre with a locked posterior dislocation of the right hip, with fractures of the femoral neck and the posterior wall of the acetabulum after a bicycle accident. An attempted closed reduction had failed. This case report describes in detail the surgical management and the clinical and radiological outcome. Open reduction and fixation with preservation of the intact retinaculum was undertaken within five hours of injury with surgical dislocation of the hip and a trochanteric osteotomy. Two years after operation the function of the injured hip was good. Plain radiographs and MR scans showed early signs of osteoarthritis with some loss of joint space but no evidence of avascular necrosis. The patient had begun skiing and hiking again. The combination of fractures of the neck of the femur and of the posterior wall of the acetabulum hampers closed reduction of a posterior dislocation of the hip. Surgical dislocation of the hip with trochanteric flip osteotomy allows controlled open reduction of the fractures, with inspection of the hip joint and preservation of the vascular supply.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.