964 resultados para FLAME AAS
Resumo:
The blending of coals has become popular to improve the performance of coals, to meet specifications of power plants and, to reduce the cost of coals, This article reviews the results and provides new information on ignition, flame stability, and carbon burnout studies of blended coals. The reviewed studies were conducted in laboratory-, pilot-, and full-scale facilities. The new information was taken in pilot-scale studies. The results generally show that blending a high-volatile coal with a low-volatile coal or anthracite can improve the ignition, flame stability and burnout of the blends. This paper discusses two general methods to predict the performance of blended coals: (1) experiment; and (2) indices. Laboratory- and pilot-scale tests, at least, provide a relative ranking of the combustion performance of coal/blends in power station boilers. Several indices, volatile matter content, heating value and a maceral index, can be used to predict the relative ranking of ignitability and flame stability of coals and blends. The maceral index, fuel ratio, and vitrinite reflectance can also be used to predict the absolute carbon burnout of coal and blends within limits. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
O mercúrio é um elemento que ainda necessita constante monitoramento devido sua capacidade tóxica em concentrações em níveis de traço com possibilidade de contaminação e exposição por uma variedade de formas e compostos presentes no ambiente. Esse estudo possuiu como objetivo a obtenção de um procedimento simplificado e eficiente para a determinação de teores de mercúrio em tecidos de rato Wistar a partir da otimização de um método de determinação, utilizando um sistema de geração de vapor frio acoplado a espectrometria de absorção atômica com forno de grafite (CV-GF AAS). Houve a comparação entre métodos de digestão, comparação de métodos de amalgamação, otimização, verificação do método a partir da obtenção de figuras de mérito e análise de amostras de fígado e rins de ratos tratados com exposição crônica ao mercúrio. Os resultados comprovaram que o método de digestão em bloco digestor, a utilização de amalgamação por recobrimento de tubo em ouro em conjunto com rede de ouro e adição pré-análise à solução de simeticona e isopropanol apresentou os melhores resultados, com teores de recuperação médios entre 92 e 114 %, viabilizando a utilização do procedimento proposto.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The mineral content (phosphorous (P), potassium (K), sodium (Na), calcium (Ca), magnesium (Mg), iron (Fe), manganese (Mn), zinc (Zn) and copper (Cu)) of eight ready-to-eat baby leaf vegetables was determined. The samples were subjected to microwave-assisted digestion and the minerals were quantified by High-Resolution Continuum Source Atomic Absorption Spectrometry (HR-CS-AAS) with flame and electrothermal atomisation. The methods were optimised and validated producing low LOQs, good repeatability and linearity, and recoveries, ranging from 91% to 110% for the minerals analysed. Phosphorous was determined by a standard colorimetric method. The accuracy of the method was checked by analysing a certified reference material; results were in agreement with the quantified value. The samples had a high content of potassium and calcium, but the principal mineral was iron. The mineral content was stable during storage and baby leaf vegetables could represent a good source of minerals in a balanced diet. A linear discriminant analysis was performed to compare the mineral profile obtained and showed, as expected, that the mineral content was similar between samples from the same family. The Linear Discriminant Analysis was able to discriminate different samples based on their mineral profile.
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2011
Resumo:
We derive analytical expressions for the propagation speed of downward combustion fronts of thin solid fuels with a background flow initially at rest. The classical combustion model for thin solid fuels that consists of five coupled reaction-convection-diffusion equations is here reduced into a single equation with the gas temperature as the single variable. For doing so we apply a two-zone combustion model that divides the system into a preheating region and a pyrolyzing region. The speed of the combustion front is obtained after matching the temperature and its derivative at the location that separates both regions.We also derive a simplified version of this analytical expression expected to be valid for a wide range of cases. Flame front velocities predicted by our analyticalexpressions agree well with experimental data found in the literature for a large variety of cases and substantially improve the results obtained from a previous well-known analytical expression
Resumo:
A determinação de As por espectrometria de absorção atômica com geração de hidretos (HG-AAS) constitui um método simples, sensível, preciso e de baixo custo. Entretanto, essa técnica requer a pré-redução das espécies de As(V), o que se obtém através do uso de agentes redutores como o KI. Em extratos contendo agentes oxidantes, a pré-redução do As é comprometida, como acontece em extratos obtidos pela aplicação do método BCR (acrônimo francês para Community Bureau of Reference) para a extração sequencial de As em sedimentos. O objetivo deste trabalho foi avaliar as condições de redução do As(V) a As(III), de modo a permitir o uso da HG-AAS para a quantificação do arsênio em extratos obtidos a partir do método BCR. Foram avaliadas condições reacionais utilizando KI, L-cisteína e ácido ascórbico. Para cada uma das etapas de extração do método BCR, diferentes condições de pré-redução possibilitaram a detecção quantitativa do As presente. O uso do método BCR para a extração de arsênio em amostras de sedimentos contaminadas e a aplicação das condições de pré-redução do As(V) selecionadas, seguida pela detecção por HG-AAS, forneceram percentagens de recuperação entre 91 e 99 %.
Resumo:
Underbody plows and High Speed Ice Blades are an integral part of clearing Iowa roads of snow and ice during winter operations. Changing these blades requires crews to suspend plowing operations and return to the garage decreasing time spent clearing roads and increasing workplace hazards. A blade with a longer lifespan is desired. The Department is determining if using plow blades that have been flame hardened increase longevity of use over the Departments current underbody plow blades that are oven baked. This would reduce downtime and employee exposure to workplace hazards and increase productivity per dollar spent.
Resumo:
The aim of this work was to compare the performances of the L'vov and integrated platforms in order to overcome the interferences found on lead determination in zidovudine by ET AAS. Pyrolysis and atomization temperatures found with integrated platform were 700 and 1400°C, respectively. The characteristic masses were 12.7 ± 1.2 pg with integrated platform and 11.1 ± 1.3 pg with grooved platform. The ratio between the slopes of zidovudine and aqueous curves shows a decrease in the interferences when the L'vov platform is used (bAZT/b aq = 0.97 ± 0.10) and the detection limit found was 0.03 µg.g-1. That ratio was 0.85 ± 0.07 with the integrated platform.
Resumo:
Thermospray flame furnace Atomic Absorption Spectrometry (TS-FF-AAS) was used for the total determination of Cd, Pb and Zn in fresh water and seawater samples at µg L-1 levels, and in marine sediment samples at µg g-1 levels. Using a sample loop of 50 µL and a peristaltic pump the samples were transported into the metallic tube placed over an air/acetylene flame, through a ceramic capillary (o.d. = 3.2 mm) containing two parallel internal orifices (i.d = 0.5 mm). The detection limits determined for Cd, Pb and Zn using a synthetic water matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2) were 0.32 µg L-1; 2.6 µg L-1 and 0.21 µg L-1 respectively. The methodology by TS-FF-AAS was validated by determination of Cd, Pb and Zn in certified reference materials of water and marine sediment, and the t-test for differences between means was applied. No statistically significant differences were established in fresh water and seawater (p>0.05), whereas differences became apparent in marine sediment (p<0.03).
Resumo:
A simple cloud point extraction procedure is presented for the preconcentration of copper in various samples. After complexation by 4-hydroxy-2-mercapto-6-propylpyrimidine (PTU), copper ions are quantitatively extracted into the phase rich in Triton X-114 after centrifugation. Methanol acidified with 0.5 mol L-1 HNO3 was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). Analytical parameters including concentrations for PTU, Triton X-114 and HNO3, bath temperature, centrifugation rate and time were optimized. The influences of the matrix ions on the recoveries of copper ions were investigated. The detection limits (3SDb/m, n=4) of 1.6 ng mL-1 along with enrichment factors of 30 for Cu were achieved. The proposed procedure was applied to the analysis of environmental samples.
Resumo:
An evaluation of the performance of a continuous flow hydride generator-nebulizer for flame atomic absorption spectrometry was carried out. Optimization of nebulizer gas flow rate, sample acid concentration, sample and tetrahydroborate uptake rates and reductant concentration, on the As and Se absorbance signals was carried out. A hydrogen-argon flame was used. An improvement of the analytical sensitivity relative to the conventional bead nebulizer used in flame AA was obtained (2 (As) and 4.8 (Se) µg L-1). Detection limits (3σb) of 1 (As) and 1.3 (Se) µg L-1 were obtained. Accuracy of the method was checked by analyzing an oyster tissue reference material.
Resumo:
This paper present an overview of way covered for the spectrometry of atomic absorption (AAS), tracing a line of the historical events in its development and its establishment as a multielement technique. Additionally, the efforts carried by through several researchers in the search for the instrumental evolution, the advances, advantages, limitations, and trends of this approach are related. Several works focusing its analytical applications are cited employing simultaneous multielement determination by flame (FAAS) and/or graphite furnace (GF AAS), and fast sequential multielement determination using FAAS are reported in the present review.
Resumo:
A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1) and is transported to flame atomic absorption spectrometer for quantification. The effect of pH, sample and eluent flow rates and presence of various cations and anions on the retention of zinc was investigated. The sorption of zinc was quantitative in the pH range of 5.5-8.5. For a sample volume of 25 mL an enrichment factor of 144 and a detection limit (3S) of 0.2 µg L-1 was obtained. The precision (RSD, n=7) was 3.0% at the 20 µg L-1 level. The developed system was successfully applied to the determination of zinc in water samples, hair, urine and saliva.