992 resultados para FENTON REACTION


Relevância:

60.00% 60.00%

Publicador:

Resumo:

IgG can be denatured in vitro by reactive oxygen species (ROS). Native IgG activates the complement cascade through C1q. Using a modified ELISA, C1q binding activity of rheumatoid IgG has been compared to IgG denatured by neutrophil-derived ROS. The C1q binding activity of rheumatoid synovial fluid IgG is greater than the corresponding serum IgG (P < 0.01). Denaturation of IgG by activated polymorphs or the Fenton reaction decreased its C1q binding activity (P < 0.01). In vitro exposure of IgG to OH. and ROO. increased its interaction with C1q (P < 0.01). Hypochlorous acid had no effect. ROS-induced alteration to IgG-C1q binding activity may promote the inflammatory response in rheumatoid arthritis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Porosity development of mesostructured colloidal silica nanoparticles is related to the removal of the organic templates and co-templates which is often carried out by calcination at high temperatures, 500-600 °C. In this study a mild detemplation method based on the oxidative Fenton chemistry has been investigated. The Fenton reaction involves the generation of OH radicals following a redox Fe3+/Fe2+ cycle that is used as catalyst and H2O2 as oxidant source. Improved material properties are anticipated since the Fenton chemistry comprises milder conditions than calcination. However, the general application of this methodology is not straightforward due to limitations in the hydrothermal stability of the particular system under study. The objective of this work is three-fold: 1) reducing the residual Fe in the resulting solid as this can be detrimental for the application of the material, 2) shortening the reaction time by optimizing the reaction temperature to minimize possible particle agglomeration, and finally 3) investigating the structural and textural properties of the resulting material in comparison to the calcined counterparts. It appears that the Fenton detemplation can be optimized by shortening the reaction time significantly at low Fe concentration. The milder conditions of detemplation give rise to enhanced properties in terms of surface area, pore volume, structural preservation, low Fe residue and high degree of surface hydroxylation; the colloidal particles are stable during storage. A relative particle size increase, expressed as 0.11%·h-1, has been determined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A mild protocol that allows the template removal of soft un-aged silica nanoparticles was investigated. After oxidizing the organic template by Fenton chemistry, a good structural preservation is only achieved when the material is equilibrated and dried in a low-surface tension solvent. This avoids excessive capillary stress induced by the high surface tension of water, a major component in the Fenton reaction medium. The Fenton reaction should be carried out under mild conditions as well; otherwise the sample deteriorates by extensive hydrolysis, and capillary stress, and the structural ordering diminishes severely. We propose employing 10 ppm Fe concentration at 70 °C for 24 h for the cetyltrimethylammonium bromide template. The proposed protocol involves 2 steps resulting in an overall significantly higher pore volume attributed to the wider pores and limited particle agglomeration, while the calcined counterpart evidences aggregation and loss of the hexagonal ordering. n-BuOH exchange is unnecessary when the mesophase is stabilized by ageing, as the structure resists the water capillary stress. © The Royal Society of Chemistry 2013.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O stress oxidativo está associado ao envelhecimento e a inúmeras patologias, nomeadamente a doenças neurodegenerativas e cardiovasculares, e a diversos outros fatores. O stress oxidativo leva à oxidação de importantes biomoléculas como os lípidos e, ao contrário da maior parte dos produtos de oxidação de fosfolípidos e ácidos gordos insaturados (PUFAS), os produtos de oxidação de glicosfingolípidos (GSLs) têm sido escassamente estudados. Os glicosfingolípidos são moléculas muito diversificadas estruturalmente e com importantes funções, essencialmente no sistema nervoso central (SNC) onde estão localizados maioritariamente. Deste modo, alterações na estrutura dos GSLs conduzirão a consequente comprometimento das suas funções e ao possível desenvolvimento de patologias. Assim para identificar as modificações oxidativas que ocorrem em glicosfingolípidos e pressupor consequentes efeitos biológicos nas células sob stress oxidativo, prepararamse sistemas modelo biomiméticos com diferentes GSLs os quais foram expostos a radicais hidroxilo gerados sob condições da reação de Fenton (H2O2 e Fe2+) e as reações foram monitorizadas por diferentes metodologia utilizando a espectrometria de massa. Os resultados obtidos com este estudo permitiram-nos identificar vários produtos de oxidação produzidos durante a oxidação desta classe de lípidos. Os produtos de oxidação observados em comum, em todos os GSLs estudados (C16:0GalCer, C24:1GalCer, C24:1LacCer e GM1) foram as suas correspondentes ceramidas. Estas atuam como agentes pro-apoptóticos e podem in vivo promover a neurodegeneração nas células sob stress oxidativo. Também foi possível observar produtos com inserção de oxigénio junto às duplas ligações ou na cadeia de esfingosina (no caso do GM1) ou na cadeia de ácido gordo monoinsaturada (no caso da C24:1GalCer, C24:1LacCer), corroborando o facto de que ácidos gordos saturados não são susceptíveis à oxidação por radicais. Interessantemente em ambos os GSLs de cadeias glicosiladas compostas com mais de um açúcar (C24:1LacCer e GM1) observou-se a despolimerização oxidativa da porção glicosilada por quebra das correspondentes ligações glicosídicas. Esta degradação leva à formação de GlcCer no caso de oxidação de LacCer ou na formação de outros gangliósidos (GM2, GM3, asialoGM1 e asialoGM2) e glicolípidos (LacCer e GlcCer), no caso de oxidação de GM1. A formação por via radicalar não enzimática destes GSLs leva a distúrbios no perfil lipídico. Previamente, em certas doenças, foram observadas variações na concentração do perfil de gangliósidos e de ceramidas. Estes dados permitem sugerir que em células em condições de stress oxidativo, a acumulação de gangliósidos mais simples e ceramidas poderá ter uma contribuição de produtos da degradação oxidativa dos gangliósidos e GSLs mais complexos. Este trabalho contribui assim para uma melhor compreensão das modificações estruturais que ocorrem em alguns glicosfingolípidos em condições de stress oxidativo. Os produtos de oxidação aqui identificados suportam a sua possível futura deteção em sistemas biológicos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poluições da água e do solo são duas das cinco categorias básicas de poluição ambiental. As outras três são do ar, ruído e luz. Poluição ocorre quando um material/produto químico é adicionado ao meio ambiente afetando-o adversamente. Uma vez que a poluição existe, retornar a matriz impactada para o seu estado anteriormente não poluído torna-se muito difícil ou até mesmo impossível em alguns casos. Os compostos organoclorados (OC) representam um importante grupo de poluentes orgânicos persistentes (POP), devido à sua toxicidade e elevada persistência no ambiente. Diferentes técnicas de remediação de solo e água subterrânea têm sido desenvolvidas com o objetivo de reparar as áreas contaminadas em menor tempo e custo possíveis e, assim, a oxidação química in situ tem se mostrado uma técnica cada vez mais atraente devido sua simplicidade e baixo custo. A degradação de dois compostos organoclorados via oxidação química por reagente de Fenton em solução aquosa é o objeto do presente trabalho. Para tanto, foram selecionados dois compostos, sendo um alifático e outro aromático. Assim, foram avaliadas as condições de degradação dos compostos organoclorados em relação às concentrações do oxidante em diferentes tempos reacionais, diferentes fontes de catalisador e, de forma qualitativa, quais foram os principais subprodutos formados. Os ensaios oxidativos foram realizados em meio aquoso com temperatura controlada a 25 C e em 3 configurações de [Fe2+] e [H2O2]. A extração dos compostos de interesse para a fase orgânica também foi estudada. A análise dos extratos revelou que o acetato de etila foi o solvente que melhor extraiu os compostos de interesse da fase aquosa. Além destes ensaios, foram avaliadas outras duas fontes de Fe(II), sendo 11 óxidos de manganês dopados com ferro e a classe de solo predominante no território nacional, que é caracterizada pela sua alta concentração de ferro endógeno (latossolo). O ensaio entre as fontes de ferro revelou que tanto o óxido de Mn quanto o latossolo produziram menos subprodutos em relação à reação com a solução de sulfato Fe(II). Entretanto, em termos quantitativos, a redução na concentração de clorobenzeno foi mais efetiva na reação com a solução de Fe(II) (cerca de 63%). A identificação dos sobprodutos foi realizada a partir da análise em cromatógrafo a gás acoplado a espectrômetro de massas e em análise comparativa dos espectros com a biblioteca NIST. Os ensaios oxidativos revelaram que em baixas concentrações de oxidante, há a possibilidade de geração de subprodutos mais tóxicos que os reagentes, sendo produzido bifenilas policloradas e hexaclorociclohexano nas reações com clorobenzeno e 1,2-dicloroetano, respectivamente

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis Entitled Colour removal from dye house effluents using zero valent iron and fenton oxidation.Findings reported on kinetic profile during oxidation of dyes with Fenton’s reagent are in good agreement with observations of earlier workers on other organic substrates. This work goes a step further. Critical concentration of the dye at which the reaction mechanism undergoes transition has been identified.The oxidation of Reactive Yellow showed that the initial rates for decolorization increased linearly with an increase in hydrogen peroxide concentration over the range studied. Fenton oxidation of all dyes except Methylene Blue showed that the initial rates increased linearly with an in the ferrous sulphate concentration. This increase was observed only up to an optimum concentration beyond which further increase resulted in a decrease in the initial rates. Variation of initial rates with Ferrous sulphate concentration resulted in a linear plot passing through the origin indicating that the reaction is first order with respect to ferrous sulphate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phenolic compounds in wastewaters are difficult to treat using the conventional biological techniques such as activated sludge processes because of their bio-toxic and recalcitrant properties and the high volumes released from various chemical, pharmaceutical and other industries. In the current work, a modified heterogeneous advanced Fenton process (AFP) is presented as a novel methodology for the treatment of phenolic wastewater. The modified AFP, which is a combination of hydrodynamic cavitation generated using a liquid whistle reactor and the AFP is a promising technology for wastewaters containing high organic content. The presence of hydrodynamic cavitation in the treatment scheme intensifies the Fenton process by generation of additional free radicals. Also, the turbulence produced during the hydrodynamic cavitation process increases the mass transfer rates as well as providing better contact between the pseudo-catalyst surfaces and the reactants. A multivariate design of experiments has been used to ascertain the influence of hydrogen peroxide dosage and iron catalyst loadings on the oxidation performance of the modified AFP. High er TOC removal rates were achieved with increased concentrations of hydrogen peroxide. In contrast, the effect of catalyst loadings was less important on the TOC removal rate under conditions used in this work although there is an optimum value of this parameter. The concentration of iron species in the reaction solution was measured at 105 min and its relationship with the catalyst loadings and hydrogen peroxide level is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During production of oil and gas, there is also the production of an aqueous effluent called produced water. This byproduct has in its composition salts, organic compounds, gases and heavy metals. This research aimed to evaluate the integration of processes Induced Air Flotation (IAF) and photo-Fenton for reducing the Total Oils and Greases (TOG) present in produced water. Experiments were performed with synthetic wastewater prepared from the dispersion of crude oil in saline solution. The system was stirred for 25 min at 33,000 rpm and then allowed to stand for 50 min to allow free oil separation. The initial oil concentration in synthetic wastewater was 300 ppm and 35 ppm for the flotation and the photo-Fenton steps, respectively. These values of initial oil concentration were established based on average values of primary processing units in Potiguar Basin. The processes were studied individually and then the integration was performed considering the best experimental conditions found in each individual step. The separation by flotation showed high removal rate of oil with first-order kinetic behavior. The flotation kinetics was dependent on both the concentration and the hydrophilic-lipophilic balance (HLB) of the surfactant. The best result was obtained for the concentration of 4.06.10-3 mM (k = 0.7719 min-1) of surfactant EO 2, which represents 86% of reduction in TOG after 4 min. For series of surfactants evaluated, the separation efficiency was found to be improved by the use of surfactants with low HLB. Regarding the TOG reduction step by photo-Fenton, the largest oil removal reached was 84% after 45 min of reaction, using 0.44 mM and 10 mM of ferrous ions and hydrogen peroxide, respectively. The best experimental conditions encountered in the integrated process was 10 min of flotation followed by 45 min of photo-Fenton with overall TOG reduction of 99%, which represents 5 ppm of TOG in the treated effluent. The integration of processes flotation and photo-Fenton proved to be highly effective in reducing TOG of produced water in oilfields

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The degradation of herbicides in aqueous solution by photo-Fenton process using ferrioxalate complex (FeOx) as source of Fe2+ was evaluated under blacklight irradiation. The commercial products of the herbicides tebuthiuron, diuron and 2,4-D were used. The multivariate analysis, more precisely, the response surface methodology was applied to evaluate the role of FeOx and hydrogen peroxide concentrations as variables in the degradation process, and in particular, to define the concentration ranges that result in the most efficient degradation of the herbicides. The degradation process was evaluated by the determination of the remaining total organic carbon content (TOC), by monitoring the decrease of the concentrations of the original compounds using HPLC and by the chloride ion release in the case of diuron and 2,4-D. Under optimized conditions, 20min were sufficient to mineralize 93% of TOC from 2,4-D and 90% of diuron, including oxalate. Complete dechlorination of these compounds was achieved after 10 min reaction. It was found that the most recalcitrant herbicide is tebuthiuron, while diuron shows the highest degradability. However, under optimized conditions the initial concentration of tebuthiuron was reduced to less than 15%, while diuron and 2,4-D were reduced to around 2% after only 1 min reaction. Furthermore, it was observed that the ferrioxalate complex plays a more important role than H2O2 in the photodegradation of these herbicides in the ranges of concentrations investigated. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a spectrophotometric method for the determination of hydrogen peroxide during photodegradation reactions. The method is based on the reaction of H2O2 with amonium metavanadate in acidic medium, which results in the formation of a red-orange color peroxovanadium cation, with maximum absorbance at 450 nm. The method was optimized using the multivariate analysis providing the minimum concentration of vanadate (6.2 mmol L-1) for the maximum absorbance signal. Under these conditions, the detection limit is 143 mu mol L-1. The reaction product showed to be very stable for samples of peroxide concentrations up to 3 mmol L-1 at room temperature during 180 h. For higher concentrations however, samples must be kept refrigerated (4 degrees C) or diluted. The method showed no interference of Cl- (0.2-1.3 mmol L-1), NO3- (0.3-1.0 mmol L-1), Fe3+, (0.2-1.2 mmol L-1) and 2,4-dichlorophenol (DCP) (0.2-1.0 mmol L-1). When compared to iodometric titration, the vanadate method showed a good agreament. The method was applied for the evaluation of peroxide consumption during photo-Fenton degradation of 2,4-dichlorophenol using blacklight irradiation. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This communication proposes the use of neural networks in the prediction of residual concentrations of hydrogen peroxide from the treatment of effluents through Advanced Oxidative Processes (AOP's), in particular, the photo-Fenton process. To verify the efficiency of the oxidative process, the Chemical Oxygen Demand (COD) parameter, the values of which may be modified by the presence of oxidizing agents such as residual hydrogen peroxide, is frequently taken in account. The analysis of the H2O2 interference was performed by spectrophotometry at 450 nm wavelength, via the monitoring of the reaction of ammonia with metavanadate. The results of the hydrogen peroxide residual concentration were modeled via a feedforward neural network, with the correlation coefficients between actual and predicted values above 0.96, indicating good prediction capacity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work evaluates some collateral effects caused by the application of the Fenton process to 1,1-bis(4-chlorophenyl)-2,2,2-trichloroethane (DDT) and diesel degradation in soil. While about 80% of the diesel and 75% of the DDT present in the soil were degraded in a slurry system, the dissolved organic carbon (DOC) in the slurry filtrate increased from 80 to 880 mg l(-1) after 64 h of reaction and the DDT concentration increased from 12 to 50 mu g l(-1). Experiments of diesel degradation conducted on silica evidenced that soluble compounds were also formed during diesel oxidation. Furthermore, significant increase in metal concentrations was also observed in the slurry filtrate after the Fenton treatment when compared to the control experiment leading to excessive concentrations of Cr, Ni, Cu and Mn according to the limits imposed for water. Moreover, 80% of the organic matter naturally present in the soil was degraded and a drastic volatilization of DDT and 2,2-bis(4-chlorophenyl)-1,1-dichloroethylene was observed. Despite the high percentages of diesel and DDT degradation in soil, the potential overall benefits of its application must be evaluated beforehand taking into account the metal and target compounds dissolution and the volatilization of contaminants when the process is applied. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to compare the degradation kinetics of low (1 mg L-1) and high (25 mg L-1) concentrations of ciprofloxacin (CIP) aiming to decrease the concentration of additives and evaluate the pH limitation by the use of low iron concentrations and organic ligands. A parameterized kinetic model was satisfactorily fitted to the experimental data in order to study the performance of photo-Fenton process with specific iron sources (iron citrate, iron oxalate, iron nitrate) under different pH medium (2.5, 4.5, 6.5). The process modeling allowed selecting those process conditions (iron source, additives concentrations and pH medium) which maximize the two performance parameters related to the global equilibrium conversion and kinetic rate of the process. For the high CIP concentration, degradation was very influenced by the iron source, resulting in much lower efficiency with iron nitrate. At pH 4.5, highest TOC removal (0.87) was achieved in the presence of iron citrate, while similar CIP conversions were obtained with oxalate and citrate (0.98 after 10 min). For the low CIP concentration, much higher conversion was observed in the presence of citrate or oxalate in relation to iron nitrate up to pH 4.5. This behavior denotes the importance of complexation also at low dosages. Appropriate additives load (320 μM H 2O2; 6 μM Fe) resulted in a CIP conversion of 0.96 after10 min reaction with citrate up to pH 4.5. © 2013 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The amount of waste generated by industries has increased gradually in recent years. The proper disposal of residues has been an area of study of many researchers. Several organic compounds are considered potential contaminants of natural waters due to their high toxicity, difficult natural degradation and long persistence in the environment. Ways of recovery and reutilization as well as concepts that minimize the generation of wastes have been increasing widely. Organometallic compound of pyrazine carboxylic acid has proven to be of great interest in many areas. Herein, we studied the use of pyrazine tetracarboxylic acid ligand for complex formation with iron (Fe). The binder (C 8H4N2O8) was synthetized with the addition of Fe (complex) and tested as a catalyst in oxidation reactions of the organic model compound methylene blue (MB). Tetramethyl pyrazine was used in the synthesis, which was oxidized with potassium permanganate in order to form the ligand. The ligand (C 8H4N2O8) was then characterized to validate its formation. For the complex solution, it was used (C 8H4N2O8) and Fe (NO3)3.9H2O 0,01molL-1. After preliminary tests, it was found that the best ratio of Fe and the ligand was 2: 1. Through the oxidation tests, it could be seen that the complex has great potential for the degradation of different concentrations of MB. During only 20 minutes of reaction, approximately 60% of MB 500 mgL -1 was oxidized. The use of the complex was found to be an attractive alternative for oxidation of effluents with high organic compounds levels and contributes to the minimization of organic contaminants hazards in the environment.